A monochromatic confocal micro-x-ray fluorescence (μXRF) spectrometer for the lab
- 1 December 2020
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (12) , 123107
Abstract
Confocal micro-x-ray fluorescence (μXRF) is a powerful tool to analyze the spatial distribution of major, minor, and trace elements in three dimensions. Typical (confocal) μXRF measurements in the lab use polychromatic excitation, complicating quantification and fundamental parameter-based corrections and furthermore deteriorating peak-to-background ratios due to scattered bremsstrahlung. The goal for the new setup was to remedy these problems, without sacrificing spatial resolution, and keep it flexible for different excitation energies and transportation to other sources. The source assembly consists of a water-cooled fine-focus x-ray diffraction tube and a parallel beam-mirror, which produces a quasi-parallel, monochromatic beam. The presented results were obtained using a 2 kW molybdenum tube and a mirror for Mo-Kα. The confocal setup itself consists of two polycapillary half-lenses, one for the source side and the other for the detector side, where a 50 mm2 silicon drift detector is mounted. Both polycapillaries have a focus size of ∼15 μm for Mo-Kα. The second polycapillary can also be exchanged for a custom-designed collimator in order to perform non-confocal μXRF. Details of the technical setup and results from technical and biological samples are presented. Detection limits for selected elements from Ca to Pb in the confocal and non-confocal mode were established (e.g., 1 μg/g non-confocal and 20 μg/g confocal for As) using the NIST standard reference materials (SRMs) 621 and 1412. Furthermore, the results of the measurements of SRM 621 were evaluated using the fundamental parameter based quantification software ATI-QUANT. The results are compared with the certified values and generally are in good agreement.Keywords
Funding Information
- TU Wien “Innovative Projekte” Funds (GIP141CMXR)
This publication has 13 references indexed in Scilit:
- Development and Applications of a Laboratory Micro X-ray Fluorescence (μXRF) Spectrometer Using Monochromatic Excitation for Quantitative Elemental AnalysisAnalytical Chemistry, 2015
- Differential accumulation of lead and zinc in double-tidemarks of articular cartilageOsteoarthritis and Cartilage, 2013
- Development of a high‐resolution confocal micro‐XRF instrument equipped with a vacuum chamberX-Ray Spectrometry, 2013
- Depth‐selective elemental imaging of microSD card by confocal micro XRF analysisX-Ray Spectrometry, 2013
- Confocal micro-x-ray fluorescence spectrometer for light element analysisReview of Scientific Instruments, 2012
- Improved micro x-ray fluorescence spectrometer for light element analysisReview of Scientific Instruments, 2010
- Performance of a polycapillary halflens as focussing and collecting optic—a comparisonJournal of Analytical Atomic Spectrometry, 2009
- Three-Dimensional Trace Element Analysis by Confocal X-ray Microfluorescence ImagingAnalytical Chemistry, 2004
- Confocal μ-XRF depth analysis of paint layersNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2004
- A new 3D micro X-ray fluorescence analysis set-up – First archaeometric applicationsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2003