Mauricio Martins Donatti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mauricio Martins Donatti has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
Fernando Cardoso
4 shared publicationsLeandro Tiago Manera
Universidade Estadual de Campinas - Faculdade de Engenharia Elétrica e de Computação
4 shared publications- Fernando Henrique Cardoso
Brazilian Synchrotron Light Laboratory (LNLS), Brazilian Center of Research in Energy and Materials (CNPEM), Polo II de Alta Tecnologia—R. Giuseppe Máximo Scolfaro, 10000—Bosque das Palmeiras, Campinas, São Paulo 13085-903, Brazil
3 shared publications - Raul Back Campanelli
Data Acquisition and Processing Division, Brazilian Synchrotron Light Laboratory (LNLS), 10000 Giuseppe Máximo Scolfaro St, Campinas, Brazil
3 shared publications Alan Douglas Pereira
2 shared publicationsFernando Henrique Cardoso
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
Exploring the response of LGADs for time resolved synchrotron applications
- 1 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
Open AccessExploring the response of LGADs for time resolved synchrotron applications
- Open Access
- 9 June 2026
- Published by MDPI AG in Instruments
- Vol. 10 (2) , 32
High-Resolution Quad-Channel Picoammeter: Characterization and Commissioning
To address the high demand for precise low-current measurements at the Sirius’ beamlines, a quad-channel high-resolution Ethernet picoammeter has been designed. The instrument can measure currents ranging from femtoampere to milliampere across eight selectable ranges, featuring integrated analog-to-digital converters (ADCs), enabling sampling rates of up to 2 ksps and synchronization capabilities. This work describes the hardware design, the hardware handling procedures to achieve sub-picoampere resolution, and the characterization results of the instrument, considering the experimental results from Sirius beamlines. The designed device provides noise performance and gain accuracy that is comparable to high-end commercial solutions, proving its suitability for critical applications like on-the-fly scanning experiments. Special attention will be given to evaluating trigger latency, synchronization outcomes, as well as the device’s installation and commissioning at beamlines. Furthermore, we will deeply explore the interplay between the trigger period, digital filter bandwidth, and front-end analog bandwidth to optimize the signal-to-noise ratio in specific applications. The hardware project is publicly available in CERN’s open hardware repository.
- 9 June 2026
- Published by MDPI AG in Instruments
- Vol. 10 (2) , 32
Open AccessHigh-Resolution Quad-Channel Picoammeter: Characterization and Commissioning
To address the high demand for precise low-current measurements at the Sirius’ beamlines, a quad-channel high-resolution Ethernet picoammeter has been designed. The instrument can measure currents ranging from femtoampere to milliampere across eight selectable ranges, featuring integrated analog-to-digital converters (ADCs), enabling sampling rates of up to 2 ksps and synchronization capabilities. This work describes the hardware design, the hardware handling procedures to achieve sub-picoampere resolution, and the characterization results of the instrument, considering the experimental results from Sirius beamlines. The designed device provides noise performance and gain accuracy that is comparable to high-end commercial solutions, proving its suitability for critical applications like on-the-fly scanning experiments. Special attention will be given to evaluating trigger latency, synchronization outcomes, as well as the device’s installation and commissioning at beamlines. Furthermore, we will deeply explore the interplay between the trigger period, digital filter bandwidth, and front-end analog bandwidth to optimize the signal-to-noise ratio in specific applications. The hardware project is publicly available in CERN’s open hardware repository.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01032
Thickness dependence of MTF and count rate on the performance of silicon PIMEGA detectors at Sirius beamlines
Hybrid pixel detectors are photon-counting devices for X-ray imaging and diffraction techniques at the fourth-generation Sirius synchrotron light source (LNLS/CNPEM). This work presents a comprehensive characterization regarding Modulation Transfer Function and pixel count rate linearity under high-flux conditions of the large-area PIMEGA detectors of 300 and 675 μm thick silicon sensors. They consist of photon-counting devices with a 55 microns pixel size based on Medipix3RX ASIC. The results validate the successful construction and performance of the Medipix3RX-based PIMEGA detectors. The silicon sensor platform offers a viable compromise between absorption efficiency and spatial resolution, making it a highly attractive technological solution for imaging and diffraction applications across the tender to initial hard X-ray energy ranges.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , C01032
Thickness dependence of MTF and count rate on the performance of silicon PIMEGA detectors at Sirius beamlines
Hybrid pixel detectors are photon-counting devices for X-ray imaging and diffraction techniques at the fourth-generation Sirius synchrotron light source (LNLS/CNPEM). This work presents a comprehensive characterization regarding Modulation Transfer Function and pixel count rate linearity under high-flux conditions of the large-area PIMEGA detectors of 300 and 675 μm thick silicon sensors. They consist of photon-counting devices with a 55 microns pixel size based on Medipix3RX ASIC. The results validate the successful construction and performance of the Medipix3RX-based PIMEGA detectors. The silicon sensor platform offers a viable compromise between absorption efficiency and spatial resolution, making it a highly attractive technological solution for imaging and diffraction applications across the tender to initial hard X-ray energy ranges.
- 1 December 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (12) , C12003
Conceptual design of TUPI (Timepix4-based Ultra-fast Photon Imaging) detector's hardware
TUPI (Timepix4-based Ultra-fast Photon Imaging) is the new family of direct conversion and vacuum-compatible hybrid detectors under design at Sirius, the Brazilian 4th generation light source. Based on the Timepix4 Application Specific Integrated Circuit (ASIC), it targets different kinds of experiments, such as tomography and spectrometry, and will be used in multiple bioimaging beamlines of Orion, Brazil's Biosafety Level 4 (BSL4) Laboratory project. Also, it will cover a wide energy range (5 to 45 keV) by using different sensors materials (Si, GaAs, CdTe, etc.). Designed in a modular approach to ensure scalability for constructing larger active areas in a compact form, each TUPI module will be composed by a set of 3x side-by-side Timepix4 ASICs to provide a sensitive area of approximately 74×28 mm2 (1344×512 pixels of 55 μm pitch), streaming up to 44 kfps through up to 48×10.24 Gbps optical links directly connected to a Data Acquisition (DAQ) system.
- 1 December 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (12) , C12003
Conceptual design of TUPI (Timepix4-based Ultra-fast Photon Imaging) detector's hardware
TUPI (Timepix4-based Ultra-fast Photon Imaging) is the new family of direct conversion and vacuum-compatible hybrid detectors under design at Sirius, the Brazilian 4th generation light source. Based on the Timepix4 Application Specific Integrated Circuit (ASIC), it targets different kinds of experiments, such as tomography and spectrometry, and will be used in multiple bioimaging beamlines of Orion, Brazil's Biosafety Level 4 (BSL4) Laboratory project. Also, it will cover a wide energy range (5 to 45 keV) by using different sensors materials (Si, GaAs, CdTe, etc.). Designed in a modular approach to ensure scalability for constructing larger active areas in a compact form, each TUPI module will be composed by a set of 3x side-by-side Timepix4 ASICs to provide a sensitive area of approximately 74×28 mm2 (1344×512 pixels of 55 μm pitch), streaming up to 44 kfps through up to 48×10.24 Gbps optical links directly connected to a Data Acquisition (DAQ) system.
- Open Access
- 9 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Evaluation and synthesis of perovskite crystals as high-Z sensors for hybrid pixel detectors
High-energy photon imaging experiments are crucial techniques in synchrotron facilities, often employing hybrid pixel detectors for these operations. These detectors combine a photo-sensitive semiconductor component with a pixelated microelectronic Application Specific Integrated Circuit (ASIC) for signal processing and image formation. However, detecting photons above 90 keV poses significant challenges, even for heavy semiconductors, due to lower photoelectric absorption cross-section at this energy range. Nevertheless, lead-based perovskites, such as \({\text{CsPbBr}}_3\), are remarkable alternatives as they present excellent cross-section values and noteworthy transport properties, contributing to increased high-energy detection efficiencies. Here, we employ a chemical synthesis route for \({\text{CsPbBr}}_3\) single-crystals, enabling experimental measurements of carrier mobility of 100.7 \({\text{cm}}^{2}\)/Vs. We also developed a simulation algorithm to calculate the current pulses generated on pixelated electrodes. Our simulations evaluate \({\text{CsPbBr}}_3\)’s performance coupled with the latest photon-counter ASIC developed by CERN, the Timepix4. Our findings indicate that \({\text{CsPbBr}}_3\) crystals require intense applied electric fields, around 1 kV/mm, for accurate signal integration. Furthermore, we observed no correlation between incident energy and induced pulse width. Through microelectronics simulations, we demonstrate that the signal formation behavior of \({\text{CsPbBr}}_3\) is compatible with Timepix4 ASICs, consequently establishing operational guidelines for employing this promising material as sensors in hybrid pixel detectors.- 9 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Open AccessEvaluation and synthesis of perovskite crystals as high-Z sensors for hybrid pixel detectors
High-energy photon imaging experiments are crucial techniques in synchrotron facilities, often employing hybrid pixel detectors for these operations. These detectors combine a photo-sensitive semiconductor component with a pixelated microelectronic Application Specific Integrated Circuit (ASIC) for signal processing and image formation. However, detecting photons above 90 keV poses significant challenges, even for heavy semiconductors, due to lower photoelectric absorption cross-section at this energy range. Nevertheless, lead-based perovskites, such as \({\text{CsPbBr}}_3\), are remarkable alternatives as they present excellent cross-section values and noteworthy transport properties, contributing to increased high-energy detection efficiencies. Here, we employ a chemical synthesis route for \({\text{CsPbBr}}_3\) single-crystals, enabling experimental measurements of carrier mobility of 100.7 \({\text{cm}}^{2}\)/Vs. We also developed a simulation algorithm to calculate the current pulses generated on pixelated electrodes. Our simulations evaluate \({\text{CsPbBr}}_3\)’s performance coupled with the latest photon-counter ASIC developed by CERN, the Timepix4. Our findings indicate that \({\text{CsPbBr}}_3\) crystals require intense applied electric fields, around 1 kV/mm, for accurate signal integration. Furthermore, we observed no correlation between incident energy and induced pulse width. Through microelectronics simulations, we demonstrate that the signal formation behavior of \({\text{CsPbBr}}_3\) is compatible with Timepix4 ASICs, consequently establishing operational guidelines for employing this promising material as sensors in hybrid pixel detectors. - 9 September 2024
SIRIUS fast beam orbit interlock system
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03028
Development of a quad-channel high-resolution digital picoammeter for beam diagnostics
In synchrotron light source applications, the photon beam interaction with various materials can produce electric charge which can be measured as current and be used to diagnose particle trajectories, beam intensity, beam profile, position, and stability. Sirius, a 4th-generation Brazilian synchrotron light source, will make use of hundreds of low-intensity measurement instruments. This work aims to show and discuss the design details, challenges, and test results of an Ethernet four-channel high-performance digital ammeter, applied for general-purpose beam diagnostics. The device is based on low-noise and extremely low input bias bipolar transimpedance amplifiers with eight selectable ranges (full scales from pA to mA). Characterization results show that the achieved gain, accuracy, and noise performance are on the same order of magnitude as those of expensive commercial benchtop equipment. In low bandwidth applications, the device was able to measure amplitudes of hundreds of picoampere with intrinsic noise of units of femtoampere (RMS). The designed device is a cost-effective solution.
- 1 March 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (03) , C03028
Development of a quad-channel high-resolution digital picoammeter for beam diagnostics
In synchrotron light source applications, the photon beam interaction with various materials can produce electric charge which can be measured as current and be used to diagnose particle trajectories, beam intensity, beam profile, position, and stability. Sirius, a 4th-generation Brazilian synchrotron light source, will make use of hundreds of low-intensity measurement instruments. This work aims to show and discuss the design details, challenges, and test results of an Ethernet four-channel high-performance digital ammeter, applied for general-purpose beam diagnostics. The device is based on low-noise and extremely low input bias bipolar transimpedance amplifiers with eight selectable ranges (full scales from pA to mA). Characterization results show that the achieved gain, accuracy, and noise performance are on the same order of magnitude as those of expensive commercial benchtop equipment. In low bandwidth applications, the device was able to measure amplitudes of hundreds of picoampere with intrinsic noise of units of femtoampere (RMS). The designed device is a cost-effective solution.
- Open Access
- 1 December 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2380 (1)
Commissioning of the cryogenic sample environment for the TARUMÃ station at the CARNAÚBA beamline at Sirius/LNLS
TARUMÃ is a multi-technique station at CARNAÚBA (Coherent X-Ray Nanoprobe Beamline) at the 4th-generation light source Sirius at the Brazilian Synchrotron Light Laboratory (LNLS). With a tender-to-hard energy range from 2.05 to 15 keV and a fully coherent nanoprobe focused via an all-achromatic KB (Kirkpatrick-Baez) optics, it can be used for simultaneous multiple nanoscale X-ray techniques in 2D and 3D. This includes ptychography coherent diffraction imaging (ptycho-CDI), absorption spectroscopy (XAS), diffraction (XRD), fluorescence (XRF) and luminescence (XEOL). In particular, the tender energies can be used to study light elements that are commonly present in soft biological samples, ensuring the unique position of the station in the Life and Environmental Sciences program at LNLS. Still, enabling this range of experiments is sometimes only possible with cryogenically cooled samples as the high beam dose can result in both chemical and structural damage at ambient temperature conditions. At TARUMÃ, to comply with the heavily occupied volume around the sample and the sample positioning architecture, this is enabled by an open-atmosphere cryogenic system based on a commercial cryojet and a custom-designed sample holder. Following a predictive engineering approach, the system is capable of conditioning the sample down to 155K, whilst avoiding icing and condensation in nearby instrumentation and preserving the nanometer-level positioning requirements of the scanning station. Here we present the commissioning results of the referred system along with the first beamline measurements.
- 1 December 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2380 (1)
Open AccessCommissioning of the cryogenic sample environment for the TARUMÃ station at the CARNAÚBA beamline at Sirius/LNLS
TARUMÃ is a multi-technique station at CARNAÚBA (Coherent X-Ray Nanoprobe Beamline) at the 4th-generation light source Sirius at the Brazilian Synchrotron Light Laboratory (LNLS). With a tender-to-hard energy range from 2.05 to 15 keV and a fully coherent nanoprobe focused via an all-achromatic KB (Kirkpatrick-Baez) optics, it can be used for simultaneous multiple nanoscale X-ray techniques in 2D and 3D. This includes ptychography coherent diffraction imaging (ptycho-CDI), absorption spectroscopy (XAS), diffraction (XRD), fluorescence (XRF) and luminescence (XEOL). In particular, the tender energies can be used to study light elements that are commonly present in soft biological samples, ensuring the unique position of the station in the Life and Environmental Sciences program at LNLS. Still, enabling this range of experiments is sometimes only possible with cryogenically cooled samples as the high beam dose can result in both chemical and structural damage at ambient temperature conditions. At TARUMÃ, to comply with the heavily occupied volume around the sample and the sample positioning architecture, this is enabled by an open-atmosphere cryogenic system based on a commercial cryojet and a custom-designed sample holder. Following a predictive engineering approach, the system is capable of conditioning the sample down to 155K, whilst avoiding icing and condensation in nearby instrumentation and preserving the nanometer-level positioning requirements of the scanning station. Here we present the commissioning results of the referred system along with the first beamline measurements.