    Evaluation of the uncertainty of the spectral UV irradiance measured by double- and single-monochromator Brewer spectrophotometers

    by Carmen González, José M. Vilaplana, Alberto Redondas, Javier López-Solano, José M. San Atanasio, Richard Kift, Andrew R. D. Smedley, Pavel Babal, Ana Díaz, Nis Jepsen, et al.

    Brewer instruments are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in characterising the instruments. This evaluation is essential to determine the quality of the measurements as well as their comparability to other datasets. In this study, eight double- and two single-monochromator Brewers are characterised, and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected because it provides reliable uncertainty estimations and considers the nonlinearity of certain steps in the UV processing algorithm. The combined standard uncertainty depends on the Brewer instrument, varying between 2.5 % and 4 % between 310 and 350 nm. These uncertainties arise primarily from radiometric stability, cosine correction, and the uncertainty of the lamp used during calibration. At shorter wavelengths, the differences between single- and double-monochromator Brewers increase. For example, at 296 nm and a solar zenith angle (SZA) of 40°, the relative uncertainties of single Brewers range between 11 % and 23 %, whereas double Brewers have uncertainties of 3 %–5 %. As the measured wavelength decreases, the correction of stray light (for single Brewers), dark counts, and noise become the dominant sources of uncertainty. These results indicate that the accuracy of fully characterised double Brewers is sufficient for biological studies and trend detection, whereas single Brewers might be limited to wavelengths and SZAs below 305 nm and 70°, respectively.

  • Open Access

    Reply on AC1

    by Carmen González, José Manuel Vilaplana, Alberto Redondas, Javier López-Solano, José María San Atanasio, Richard Kift, Andrew R. D. Smedley, Pavel Babal, Ana Díaz, Nis Jepsen, et al.

    Brewer spectroradiometers are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in solar UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in the uncertainty propagation. This evaluation is essential to determine the quality of the measurements as well as their comparability to other measurements. In this study, eight double- and two single-monochromator Brewers are characterised and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected as it provides reliable uncertainty estimations and considers the nonlinearity of the UV processing algorithm. The combined standard uncertainty depends on the Brewer, varying between 2.5 % and 4 % for the 300–350 nm region. For wavelengths below 300 nm, the differences between single- and double-monochromator Brewers increase, due to stray light and dark counts. For example, at 295 nm, the relative uncertainties of single Brewers range between 11–14 % while double Brewers have uncertainties of 4–7 %. These uncertainties arise primarily from radiometric stability, the application of cosine correction, and the irradiance of the lamp used during the instrument calibration. As the intensity of the UV irradiance measured decreases, dark counts, stray light (for single Brewers), and noise become the dominant sources of uncertainty. These results indicate that the overall uncertainty of a Brewer spectroradiometer could be greatly reduced by increasing the frequency of radiometric calibration and improving the traditional entrance optics.

  • Open Access

    Comment on egusphere-2025-490

    by Carmen González, José Manuel Vilaplana, Alberto Redondas, Javier López-Solano, José María San Atanasio, Richard Kift, Andrew R. D. Smedley, Pavel Babal, Ana Díaz, Nis Jepsen, et al.

    Brewer spectroradiometers are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in solar UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in the uncertainty propagation. This evaluation is essential to determine the quality of the measurements as well as their comparability to other measurements. In this study, eight double- and two single-monochromator Brewers are characterised and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected as it provides reliable uncertainty estimations and considers the nonlinearity of the UV processing algorithm. The combined standard uncertainty depends on the Brewer, varying between 2.5 % and 4 % for the 300–350 nm region. For wavelengths below 300 nm, the differences between single- and double-monochromator Brewers increase, due to stray light and dark counts. For example, at 295 nm, the relative uncertainties of single Brewers range between 11–14 % while double Brewers have uncertainties of 4–7 %. These uncertainties arise primarily from radiometric stability, the application of cosine correction, and the irradiance of the lamp used during the instrument calibration. As the intensity of the UV irradiance measured decreases, dark counts, stray light (for single Brewers), and noise become the dominant sources of uncertainty. These results indicate that the overall uncertainty of a Brewer spectroradiometer could be greatly reduced by increasing the frequency of radiometric calibration and improving the traditional entrance optics.

  • Open Access

    Comment on egusphere-2025-490

    by Carmen González, José Manuel Vilaplana, Alberto Redondas, Javier López-Solano, José María San Atanasio, Richard Kift, Andrew R. D. Smedley, Pavel Babal, Ana Díaz, Nis Jepsen, et al.

    Brewer spectroradiometers are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in solar UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in the uncertainty propagation. This evaluation is essential to determine the quality of the measurements as well as their comparability to other measurements. In this study, eight double- and two single-monochromator Brewers are characterised and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected as it provides reliable uncertainty estimations and considers the nonlinearity of the UV processing algorithm. The combined standard uncertainty depends on the Brewer, varying between 2.5 % and 4 % for the 300–350 nm region. For wavelengths below 300 nm, the differences between single- and double-monochromator Brewers increase, due to stray light and dark counts. For example, at 295 nm, the relative uncertainties of single Brewers range between 11–14 % while double Brewers have uncertainties of 4–7 %. These uncertainties arise primarily from radiometric stability, the application of cosine correction, and the irradiance of the lamp used during the instrument calibration. As the intensity of the UV irradiance measured decreases, dark counts, stray light (for single Brewers), and noise become the dominant sources of uncertainty. These results indicate that the overall uncertainty of a Brewer spectroradiometer could be greatly reduced by increasing the frequency of radiometric calibration and improving the traditional entrance optics.

  • Open Access

    Comment on egusphere-2025-490

    by Carmen González, José Manuel Vilaplana, Alberto Redondas, Javier López-Solano, José María San Atanasio, Richard Kift, Andrew R. D. Smedley, Pavel Babal, Ana Díaz, Nis Jepsen, et al.

    Brewer spectroradiometers are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in solar UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in the uncertainty propagation. This evaluation is essential to determine the quality of the measurements as well as their comparability to other measurements. In this study, eight double- and two single-monochromator Brewers are characterised and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected as it provides reliable uncertainty estimations and considers the nonlinearity of the UV processing algorithm. The combined standard uncertainty depends on the Brewer, varying between 2.5 % and 4 % for the 300–350 nm region. For wavelengths below 300 nm, the differences between single- and double-monochromator Brewers increase, due to stray light and dark counts. For example, at 295 nm, the relative uncertainties of single Brewers range between 11–14 % while double Brewers have uncertainties of 4–7 %. These uncertainties arise primarily from radiometric stability, the application of cosine correction, and the irradiance of the lamp used during the instrument calibration. As the intensity of the UV irradiance measured decreases, dark counts, stray light (for single Brewers), and noise become the dominant sources of uncertainty. These results indicate that the overall uncertainty of a Brewer spectroradiometer could be greatly reduced by increasing the frequency of radiometric calibration and improving the traditional entrance optics.

  • Open Access

    Evaluation of the uncertainty of the spectral UV irradiance measured by double- and single-monochromator Brewer spectroradiometers

    by Carmen González, José Manuel Vilaplana, Alberto Redondas, Javier López-Solano, José María San Atanasio, Richard Kift, Andrew R. D. Smedley, Pavel Babal, Ana Díaz, Nis Jepsen, et al.

    Brewer spectroradiometers are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in solar UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in the uncertainty propagation. This evaluation is essential to determine the quality of the measurements as well as their comparability to other measurements. In this study, eight double- and two single-monochromator Brewers are characterised and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected as it provides reliable uncertainty estimations and considers the nonlinearity of the UV processing algorithm. The combined standard uncertainty depends on the Brewer, varying between 2.5 % and 4 % for the 300–350 nm region. For wavelengths below 300 nm, the differences between single- and double-monochromator Brewers increase, due to stray light and dark counts. For example, at 295 nm, the relative uncertainties of single Brewers range between 11–14 % while double Brewers have uncertainties of 4–7 %. These uncertainties arise primarily from radiometric stability, the application of cosine correction, and the irradiance of the lamp used during the instrument calibration. As the intensity of the UV irradiance measured decreases, dark counts, stray light (for single Brewers), and noise become the dominant sources of uncertainty. These results indicate that the overall uncertainty of a Brewer spectroradiometer could be greatly reduced by increasing the frequency of radiometric calibration and improving the traditional entrance optics.

  • Open Access

    Dark Signal Modeling for UV CCD-Array Spectrometer Using Ghost Pixels

    by Alba Flores, Antonio Serrano, M. Ángeles Obregón, J. Manuel Vilaplana

    Ultraviolet (UV) solar radiation causes multiple health detriments and materials degradation, these effects being strongly wavelength dependent. Although CCD-array spectrometers are an alternative to expensive and more labor-intensive scanning ones, they suffer from different sources of error, such as the dark signal and its Poisson noise associated, that must be previously characterized in depth to guarantee the quality of the measurements. This study proposes using the signal registered by the ghost pixels available in the instruments under study to estimate the dark signal. These ghost pixels are different from the known blind pixels since these ones register the dark signal, and the first ones were found to correspond to the output preamplifier offset. More than 7000 dark signal frames were measured at different temperatures and integration times for this study. The ghost-pixels signal was found to depend linearly on the temperature and be independent on the integration time, so it can be a proxy for temperature in dark signal correction models. To estimate the dark signal, several multivariate models dependent on the integration time and the ghost-pixels signal were tested. Finally, the best two, according to the Akaike Information Criterion, were selected. The chosen models perform notably well, with R2 values over 0.95 and low rRMSE values, below 25%. One of the ghost-pixels models chosen compares well with temperature-based models, although the latter show lower rRMSE values. This study presents the ghost-pixels signal as a reliable and efficient alternative to temperature measurements for models aimed at estimating the dark signal.


  • Open Access

    Monte Carlo Evaluation of Uncertainties of UV Spectra Measured With Brewer Spectroradiometers

    by C. González, J. M. Vilaplana, A. Serrano

    Precise spectral ultraviolet (UV) measurements are needed to ensure human protection as well as to support scientific research. Quantifying the uncertainty of the UV spectra recorded is crucial to evaluate the quality of the measurements which is needed, in turn, for the assessment of their reliability. However, for double‐monochromator spectroradiometers, the analytical derivation of this uncertainty is a challenging task due to the difficulties involved in propagating individual uncertainties. Under these circumstances, a Monte Carlo simulation is a reliable alternative as it does not require the calculation of partial derivatives and considers both nonlinear effects and correlations in the data. In the present study, the uncertainty of the spectral UV irradiance measured by a Brewer MKIII spectrophotometer is evaluated using a Monte Carlo approach. This instrument belongs to the National Institute of Aerospace Technology and has successfully participated in several international campaigns, which ensures its precise calibration. The average expanded uncertainty (k = 2) of the global UV irradiance measured by this instrument varies between 10% at 300 nm and 7% at 363 nm. At shorter wavelengths, it increases sharply due to thermal and electronic noise as well as wavelength misalignment. The results indicate that a Brewer spectrophotometer is suitable for climatological studies and model validation. Nevertheless, a substantial reduction of these uncertainties might be required for accurately detecting long‐term UV trends. Although the study focused on a Brewer spectrometer, the methodology used for the uncertainty analysis is general and can be adapted to most UV spectroradiometers.


  • Open Access

    Comparison of global UV spectral irradiance measurements between a BTS CCD-array and a Brewer spectroradiometer

    by Carmen González, José M. Vilaplana, José A. Bogeat, Antonio Serrano

    Spectral measurements of UV irradiance are of great importance for protecting human health as well as for supporting scientific research. To perform these measurements, double monochromator scanning spectroradiometers are the preferred devices thanks to their linearity and stray-light reduction. However, because of their high cost and demanding maintenance, CCD-array-based spectroradiometers are increasingly used for monitoring UV irradiance. Nevertheless, CCD-array spectroradiometers have specific limitations, such as a high detection threshold or stray-light contamination. To overcome these challenges, several manufacturers are striving to develop improved instrumentation. In particular, Gigahertz-Optik GmbH has developed the stray-light-reduced BTS2048-UV-S spectroradiometer series (hereafter “BTS”). In this study, the long-term performance of the BTS and its seasonal behavior, regarding global UV irradiance, was assessed. To carry out the analysis, BTS irradiance measurements were compared against measurements from the Brewer MK-III #150 scanning spectrophotometer during three campaigns. A total of 711 simultaneous spectra, measured under cloud-free conditions and covering a wide range of solar zenith angles (SZAs; from 14 to 70∘) and UV indexes (from 2.4 to 10.6), were used for the comparison. During the three measurement campaigns, the global UV spectral ratio BTS / Brewer was almost constant (at around 0.93) in the 305–360 nm region for SZAs below 70∘. Thus, the BTS calibration was stable during the whole period of study (∼ 1.5 years). Likewise, it showed no significant seasonal or SZA dependence in this wavelength region. Regarding the UV index, a good correlation between the BTS and the Brewer #150 was found, i.e., the dynamic range of the BTS is comparable to that of the Brewer #150. These results confirm the quality of the long-term performance of the BTS array spectroradiometer in measuring global UV irradiance.


  • Open Access

    Comparison of global UV irradiance measurements between a BTS CCD-array and a Brewer spectroradiometers

    by Carmen González, José M. Vilaplana, José A. Bogeat, Antonio Serrano

    Spectral measurements of UV irradiance are of great importance to ensure human health protection as well as to support scientific research. To perform these measurements, double monochromator scanning spectroradiometers are the preferred devices, thanks to their linearity and stray-light reduction. However, because of their high cost and demanding maintenance, CCD-array-based spectroradiometers are increasingly used for monitoring UV irradiance. Nevertheless, CCD-array spectroradiometers have specific limitations, such as a high detection threshold or stray-light contamination. To overcome these challenges, several manufacturers are striving to develop improved instrumentation. In particular, Gigahertz-Optik GmbH has developed the stray-light-reduced BTS2048-UV-S spectroradiometer series (from now on called BTS). In this study, the long-term performance of the BTS and its seasonal behavior, regarding global UV irradiance, has been assessed. To carry out the analysis, BTS’ irradiance measurements have been compared against measurements of the Brewer MK-III #150 scanning spectrophotometer during three campaigns. A total of 711 simultaneous spectra, measured under cloud-free conditions and covering a wide range of solar zenith angle (from 14° to 70°) and UV index (from 2.4 to 10.6), are used for the comparison. During the three measurement campaigns, the global UV spectral ratio BTS/Brewer was almost constant (at around 0.93) in the 300–360 nm region for solar zenith angles (SZAs) below 70°. Thus, the BTS calibration was stable during the whole period of study (∼1.5 years). Likewise, it showed no seasonal nor SZA significant dependence in this wavelength region. Regarding the UV index, a good correlation between the BTS and the Brewer #150 was found, i.e. the dynamic range of the BTS is comparable to that of the Brewer #150. These results confirm the quality of the long-term performance of the BTS array spectroradiometer to measure global UV irradiance.