Evaluation of the uncertainty of the spectral UV irradiance measured by double- and single-monochromator Brewer spectrophotometers
Open Access
- 30 October 2025
- journal article
- research article
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 25 (21) , 14131-14152
Abstract
Brewer instruments are robust, widely used instruments that have been monitoring global solar ultraviolet (UV) irradiance since the 1990s, playing a key role in UV research. Unfortunately, the uncertainties of these measurements are rarely evaluated due to the difficulties involved in characterising the instruments. This evaluation is essential to determine the quality of the measurements as well as their comparability to other datasets. In this study, eight double- and two single-monochromator Brewers are characterised, and the uncertainty of their global UV measurements is estimated using the Monte Carlo method. This methodology is selected because it provides reliable uncertainty estimations and considers the nonlinearity of certain steps in the UV processing algorithm. The combined standard uncertainty depends on the Brewer instrument, varying between 2.5 % and 4 % between 310 and 350 nm. These uncertainties arise primarily from radiometric stability, cosine correction, and the uncertainty of the lamp used during calibration. At shorter wavelengths, the differences between single- and double-monochromator Brewers increase. For example, at 296 nm and a solar zenith angle (SZA) of 40°, the relative uncertainties of single Brewers range between 11 % and 23 %, whereas double Brewers have uncertainties of 3 %–5 %. As the measured wavelength decreases, the correction of stray light (for single Brewers), dark counts, and noise become the dominant sources of uncertainty. These results indicate that the accuracy of fully characterised double Brewers is sufficient for biological studies and trend detection, whereas single Brewers might be limited to wavelengths and SZAs below 305 nm and 70°, respectively.Keywords
All Related Versions
Funding Information
- Ministerio de Ciencia, Innovación y Universidades (PID2023-149390OB-C22, PID2023-149390OB-C21)
This publication has 80 references indexed in Scilit:
- A parameter determination method of unscented transformation and its approximate ability analysis in the precision estimation of nonlinear measurement adjustmentMeasurement, 2020
- Twenty-five years of spectral UV-B measurements over Canada, Europe and Japan: Trends and effects from changes in ozone, aerosols, clouds, and surface reflectivityComptes Rendus. Géoscience, 2018
- Ultraviolet radiation and the skin: Photobiology and sunscreen photoprotectionJournal of the American Academy of Dermatology, 2017
- OMI/Aura UV product validation using NILU-UV ground-based measurements in Thessaloniki, GreeceAtmospheric Environment, 2016
- Trends in spectral UV radiation from long-term measurements at Hoher Sonnblick, AustriaTheoretical and Applied Climatology, 2012
- Total ozone and surface UV trends in the United Kingdom: 1979–2008International Journal of Climatology, 2011
- The Brewer Spectrophotometer2010
- Possibilities to detect trends in spectral UV irradianceTheoretical and Applied Climatology, 2004
- Spectrometers: Operational Errors and Uncertainties1997
- A replacement for the Dobson spectrophotometer?Pure and Applied Geophysics, 1973