Mu-Cyun Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mu-Cyun Tang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Tzyy-Sheng Horng
Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
6 shared publications - Fu-Kang Wang
Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
5 shared publications - Sheng-Chao Su
Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
2 shared publications - Wei-Chih Su
Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
2 shared publications - Pin-Hsun Juan
Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
1 shared publication Rezki El Arif
Department of Electrical Engineering, National Sun Yat-sen University, Kaohsiung 80424, Taiwan
1 shared publication
Latest Publications
- 26 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (3) , 1686-1695
Hybrid Continuous-Wave and Self-Injection-Locking Monopulse Radar for Posture and Fall Detection
This article presents a novel monopulse radar that combines high-sensitivity continuous-wave (CW) and self-injection-locking (SIL) receivers to detect and localize the movements in a human body. The proposed radar utilizes a CW sum pattern and an SIL difference pattern to process the echo signal from the target, so it can produce a monopulse ratio to estimate the angle of arrival (AoA) of the echo signal. With this capability, the radar can localize the movements on the target’s chest that are caused by vital signs such as respiration and heartbeat for posture classification. In addition, the radar can be used in a fall alarm as it can detect a change of posture during a fall. As a proof of concept, a 2.4-GHz prototype radar was experimentally implemented to validate the robustness of detecting falls regardless of their direction.
- 26 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (3) , 1686-1695
Hybrid Continuous-Wave and Self-Injection-Locking Monopulse Radar for Posture and Fall Detection
This article presents a novel monopulse radar that combines high-sensitivity continuous-wave (CW) and self-injection-locking (SIL) receivers to detect and localize the movements in a human body. The proposed radar utilizes a CW sum pattern and an SIL difference pattern to process the echo signal from the target, so it can produce a monopulse ratio to estimate the angle of arrival (AoA) of the echo signal. With this capability, the radar can localize the movements on the target’s chest that are caused by vital signs such as respiration and heartbeat for posture classification. In addition, the radar can be used in a fall alarm as it can detect a change of posture during a fall. As a proof of concept, a 2.4-GHz prototype radar was experimentally implemented to validate the robustness of detecting falls regardless of their direction.
- 21 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 67 (12) , 5396-5405
Stepped-Frequency Continuous-Wave Radar With Self-Injection-Locking Technology for Monitoring Multiple Human Vital Signs
This article proposes a single-conversion stepped-frequency continuous-wave (SCSFCW) radar that combines a stepped-frequency continuous-wave (SFCW) radar and a self-injection-locked (SIL) radar to benefit from the range resolution and the Doppler sensitivity of the two radars. An 8.5-9.5-GHz prototype SCSFCW radar system that comprises a subharmonic up/down converter with a 3-3.5-GHz stepped chirp local-oscillator (LO) signal and a 2.5-GHz SIL IF signal was developed to monitor the vital signs, i.e., respiration rate (RR) and heart rate (HR), of multiple humans. The coherence and range of the developed system were significantly enhanced by using a low pulse repetition frequency (PRF). In the experiment, the minimum distinguishable radial spacing between the vibrating frequencies of the metal plates that are not azimuthally overlapped with one another corresponds to a theoretical range resolution of 15 cm. However, owing to scattering by the human body, the minimum radial spacing for distinguishing between the vital signs of the individuals is three times than that for distinguishing between the metal plates in a similar experimental setup. Accordingly, the monitoring of up to three human vital signs using the developed system was demonstrated with a range-vital-Doppler map.
- 21 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 67 (12) , 5396-5405
Stepped-Frequency Continuous-Wave Radar With Self-Injection-Locking Technology for Monitoring Multiple Human Vital Signs
This article proposes a single-conversion stepped-frequency continuous-wave (SCSFCW) radar that combines a stepped-frequency continuous-wave (SFCW) radar and a self-injection-locked (SIL) radar to benefit from the range resolution and the Doppler sensitivity of the two radars. An 8.5-9.5-GHz prototype SCSFCW radar system that comprises a subharmonic up/down converter with a 3-3.5-GHz stepped chirp local-oscillator (LO) signal and a 2.5-GHz SIL IF signal was developed to monitor the vital signs, i.e., respiration rate (RR) and heart rate (HR), of multiple humans. The coherence and range of the developed system were significantly enhanced by using a low pulse repetition frequency (PRF). In the experiment, the minimum distinguishable radial spacing between the vibrating frequencies of the metal plates that are not azimuthally overlapped with one another corresponds to a theoretical range resolution of 15 cm. However, owing to scattering by the human body, the minimum radial spacing for distinguishing between the vital signs of the individuals is three times than that for distinguishing between the metal plates in a similar experimental setup. Accordingly, the monitoring of up to three human vital signs using the developed system was demonstrated with a range-vital-Doppler map.
- 4 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (5) , 1905-1916
Monitoring Displacement by a Quadrature Self-Injection-Locked Radar With Measurement- and Differential-Based Offset Calibration Methods
This paper presents a system for remotely monitoring the displacement of a moving target. The quadrature selfinjection-locked (QSIL) radar uses an additional phase shifter to the traditional SIL radar to repeatedly switch the phase delay of injection signals between 0° and 90°. Hence, it can be utilized to determine the displacement of the moving target without the distortion due to large injection angles. Moreover, this paper proposes the measurement- and differential-based methods to calibrate dc and phase offsets before arctangent demodulation is performed to extract the displacement information. In the experiments, a 2.4-GHz prototype was implemented to detect the moving metal plate with various peak-to-peak displacements from 0.25 to 5 cm, which are 0.02× to 0.4× the operating wavelength, with a root-mean-square error of less than 1.5%. Also, the prototype was verified to detect the cardiopulmonary activities of a seated subject.
- 4 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (5) , 1905-1916
Monitoring Displacement by a Quadrature Self-Injection-Locked Radar With Measurement- and Differential-Based Offset Calibration Methods
This paper presents a system for remotely monitoring the displacement of a moving target. The quadrature selfinjection-locked (QSIL) radar uses an additional phase shifter to the traditional SIL radar to repeatedly switch the phase delay of injection signals between 0° and 90°. Hence, it can be utilized to determine the displacement of the moving target without the distortion due to large injection angles. Moreover, this paper proposes the measurement- and differential-based methods to calibrate dc and phase offsets before arctangent demodulation is performed to extract the displacement information. In the experiments, a 2.4-GHz prototype was implemented to detect the moving metal plate with various peak-to-peak displacements from 0.25 to 5 cm, which are 0.02× to 0.4× the operating wavelength, with a root-mean-square error of less than 1.5%. Also, the prototype was verified to detect the cardiopulmonary activities of a seated subject.
- 16 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 65 (12) , 5324-5333
Single Self-Injection-Locked Radar With Two Antennas for Monitoring Vital Signs With Large Body Movement Cancellation
This paper presents a novel self-injection-locked radar with two antennas to transmit and retransmit a continuous wave to opposite sides of a human body for monitoring vital signs in real time with large body movements. The system can prevent the nonlinear effects of large Doppler phase shifts on the cancellation of body motion artifacts, to extract accurate vital signs from the received Doppler-shifted signal. However, the effectiveness of the cancellation is limited by the received clutter echoes in this system. Therefore, the system also has a clutter effect elimination circuit to improve substantially the detection of vital signs in an examinee at various positions between the two antennas even when the examinee moves often by more than one wavelength.
- 16 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 65 (12) , 5324-5333
Single Self-Injection-Locked Radar With Two Antennas for Monitoring Vital Signs With Large Body Movement Cancellation
This paper presents a novel self-injection-locked radar with two antennas to transmit and retransmit a continuous wave to opposite sides of a human body for monitoring vital signs in real time with large body movements. The system can prevent the nonlinear effects of large Doppler phase shifts on the cancellation of body motion artifacts, to extract accurate vital signs from the received Doppler-shifted signal. However, the effectiveness of the cancellation is limited by the received clutter echoes in this system. Therefore, the system also has a clutter effect elimination circuit to improve substantially the detection of vital signs in an examinee at various positions between the two antennas even when the examinee moves often by more than one wavelength.
- Open Access
- 26 October 2016
- Published by MDPI AG in Biosensors
- Vol. 6 (4) , 54
Wrist Pulse Rate Monitor Using Self-Injection-Locked Radar Technology
To achieve sensitivity, comfort, and durability in vital sign monitoring, this study explores the use of radar technologies in wearable devices. The study first detected the respiratory rates and heart rates of a subject at a one-meter distance using a self-injection-locked (SIL) radar and a conventional continuous-wave (CW) radar to compare the sensitivity versus power consumption between the two radars. Then, a pulse rate monitor was constructed based on a bistatic SIL radar architecture. This monitor uses an active antenna that is composed of a SIL oscillator (SILO) and a patch antenna. When attached to a band worn on the subject’s wrist, the active antenna can monitor the pulse on the subject’s wrist by modulating the SILO with the associated Doppler signal. Subsequently, the SILO’s output signal is received and demodulated by a remote frequency discriminator to obtain the pulse rate information.
- 26 October 2016
- Published by MDPI AG in Biosensors
- Vol. 6 (4) , 54
Open AccessWrist Pulse Rate Monitor Using Self-Injection-Locked Radar Technology
To achieve sensitivity, comfort, and durability in vital sign monitoring, this study explores the use of radar technologies in wearable devices. The study first detected the respiratory rates and heart rates of a subject at a one-meter distance using a self-injection-locked (SIL) radar and a conventional continuous-wave (CW) radar to compare the sensitivity versus power consumption between the two radars. Then, a pulse rate monitor was constructed based on a bistatic SIL radar architecture. This monitor uses an active antenna that is composed of a SIL oscillator (SILO) and a patch antenna. When attached to a band worn on the subject’s wrist, the active antenna can monitor the pulse on the subject’s wrist by modulating the SILO with the associated Doppler signal. Subsequently, the SILO’s output signal is received and demodulated by a remote frequency discriminator to obtain the pulse rate information.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-75
Vital-sign detection based on a passive WiFi radar
This paper presents a passive radar to detect human vital signs with ambient WiFi signals. The proposed radar does not contain a transmitting source. Instead, it captures WiFi signals produced by a far IEEE 802.11b/g/n access point and utilizes those signals to perform vital-sign detection according to Doppler effects. The reliability of detection depends on the conditions of WiFi connection, such as downloading or non-downloading states and signal strength, which is the focus of this study.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-75
Vital-sign detection based on a passive WiFi radar
This paper presents a passive radar to detect human vital signs with ambient WiFi signals. The proposed radar does not contain a transmitting source. Instead, it captures WiFi signals produced by a far IEEE 802.11b/g/n access point and utilizes those signals to perform vital-sign detection according to Doppler effects. The reliability of detection depends on the conditions of WiFi connection, such as downloading or non-downloading states and signal strength, which is the focus of this study.