Sheng-Chao Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sheng-Chao Su has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Fu-Kang Wang
Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
2 shared publications - Mu-Cyun Tang
Department of Electrical Engineering, National Sun Yat-sen University, Kaohsiung 80424, Taiwan
2 shared publications - Tzyy-Sheng Horng
Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
2 shared publications - Pin-Hsun Juan
Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
1 shared publication
Latest Publications
- 4 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (5) , 1905-1916
Monitoring Displacement by a Quadrature Self-Injection-Locked Radar With Measurement- and Differential-Based Offset Calibration Methods
This paper presents a system for remotely monitoring the displacement of a moving target. The quadrature selfinjection-locked (QSIL) radar uses an additional phase shifter to the traditional SIL radar to repeatedly switch the phase delay of injection signals between 0° and 90°. Hence, it can be utilized to determine the displacement of the moving target without the distortion due to large injection angles. Moreover, this paper proposes the measurement- and differential-based methods to calibrate dc and phase offsets before arctangent demodulation is performed to extract the displacement information. In the experiments, a 2.4-GHz prototype was implemented to detect the moving metal plate with various peak-to-peak displacements from 0.25 to 5 cm, which are 0.02× to 0.4× the operating wavelength, with a root-mean-square error of less than 1.5%. Also, the prototype was verified to detect the cardiopulmonary activities of a seated subject.
- 4 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (5) , 1905-1916
Monitoring Displacement by a Quadrature Self-Injection-Locked Radar With Measurement- and Differential-Based Offset Calibration Methods
This paper presents a system for remotely monitoring the displacement of a moving target. The quadrature selfinjection-locked (QSIL) radar uses an additional phase shifter to the traditional SIL radar to repeatedly switch the phase delay of injection signals between 0° and 90°. Hence, it can be utilized to determine the displacement of the moving target without the distortion due to large injection angles. Moreover, this paper proposes the measurement- and differential-based methods to calibrate dc and phase offsets before arctangent demodulation is performed to extract the displacement information. In the experiments, a 2.4-GHz prototype was implemented to detect the moving metal plate with various peak-to-peak displacements from 0.25 to 5 cm, which are 0.02× to 0.4× the operating wavelength, with a root-mean-square error of less than 1.5%. Also, the prototype was verified to detect the cardiopulmonary activities of a seated subject.
- Open Access
- 26 October 2016
- Published by MDPI AG in Biosensors
- Vol. 6 (4) , 54
Wrist Pulse Rate Monitor Using Self-Injection-Locked Radar Technology
To achieve sensitivity, comfort, and durability in vital sign monitoring, this study explores the use of radar technologies in wearable devices. The study first detected the respiratory rates and heart rates of a subject at a one-meter distance using a self-injection-locked (SIL) radar and a conventional continuous-wave (CW) radar to compare the sensitivity versus power consumption between the two radars. Then, a pulse rate monitor was constructed based on a bistatic SIL radar architecture. This monitor uses an active antenna that is composed of a SIL oscillator (SILO) and a patch antenna. When attached to a band worn on the subject’s wrist, the active antenna can monitor the pulse on the subject’s wrist by modulating the SILO with the associated Doppler signal. Subsequently, the SILO’s output signal is received and demodulated by a remote frequency discriminator to obtain the pulse rate information.
- 26 October 2016
- Published by MDPI AG in Biosensors
- Vol. 6 (4) , 54
Open AccessWrist Pulse Rate Monitor Using Self-Injection-Locked Radar Technology
To achieve sensitivity, comfort, and durability in vital sign monitoring, this study explores the use of radar technologies in wearable devices. The study first detected the respiratory rates and heart rates of a subject at a one-meter distance using a self-injection-locked (SIL) radar and a conventional continuous-wave (CW) radar to compare the sensitivity versus power consumption between the two radars. Then, a pulse rate monitor was constructed based on a bistatic SIL radar architecture. This monitor uses an active antenna that is composed of a SIL oscillator (SILO) and a patch antenna. When attached to a band worn on the subject’s wrist, the active antenna can monitor the pulse on the subject’s wrist by modulating the SILO with the associated Doppler signal. Subsequently, the SILO’s output signal is received and demodulated by a remote frequency discriminator to obtain the pulse rate information.