Narmin Mohammadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Narmin Mohammadi has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Soodabeh Kimyai
Department of Operative Dentistry, School of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
11 shared publications - Mahmoud Bahari
Dental and Periodontal Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
7 shared publications - Elmira Jafari Navimipour
Department of Operative Dentistry, School of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
6 shared publications - Mohammad Esmaeel Ebrahimi Chaharom
Department of Operative Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
5 shared publications - Mahdi Abed Kahnamouei
Department of Esthetic and Restorative Dentistry, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
4 shared publications Sahand Rikhtegaran
3 shared publications
Latest Publications
- Open Access
- 29 August 2023
- Published by Hindawi Limited in International Journal of Dentistry
- Vol. 2023, 1-6
The Effect of Remaining Coronal Tissue Height on the Fracture Strength of Over-Flared Endodontically Treated Central Incisors Restored Using a Multipost Approach
Objectives. This study aimed to examine the effect of remaining coronal tissue height on the fracture strength of over-flared endodontically treated central incisors restored with multiple prefabricated fiberglass posts using the multipost approach. Materials and Methods. A total of 40 human central maxillary incisors were examined in this study. The samples were assigned to five groups (n = 8) based on the height of the remaining coronal tissue: with no remaining coronal tissue, 1-mm coronal tissue height (CTH1), 2-mm coronal tissue height, 3-mm coronal tissue height (CTH3), and one intact tooth (IT) group. Following endodontic treatment of an over-flared canal, the postspace depth was 10 mm, and the residual dentin thickness was 1 mm. Two prefabricated fiberglass posts were cemented into the root canal, adopting a multipost approach. The static load was applied at 0.5 mm/min and 135° concerning the tooth’s longitudinal axis until a fracture occurred. One-way analysis of variance and the post hoc Tukey’s test were performed to analyze the data at a significance level of . Results. The maximum fracture strength was recorded for IT (control group), while the minimum fracture strength was found for teeth with a coronal tissue height of 1 mm. The differences between IT group and other groups ( ), as well as the differences between the group with CTH3 and groups without coronal tissue and CTH1, were significant. Conclusion. In sum, an increase in the height of the remaining coronal tissue (≥3 mm) significantly increased the fracture strength of over-flared endodontically treated central incisors after restoration with prefabricated fiberglass posts by adopting a multipost approach.
- 29 August 2023
- Published by Hindawi Limited in International Journal of Dentistry
- Vol. 2023, 1-6
Open AccessThe Effect of Remaining Coronal Tissue Height on the Fracture Strength of Over-Flared Endodontically Treated Central Incisors Restored Using a Multipost Approach
Objectives. This study aimed to examine the effect of remaining coronal tissue height on the fracture strength of over-flared endodontically treated central incisors restored with multiple prefabricated fiberglass posts using the multipost approach. Materials and Methods. A total of 40 human central maxillary incisors were examined in this study. The samples were assigned to five groups (n = 8) based on the height of the remaining coronal tissue: with no remaining coronal tissue, 1-mm coronal tissue height (CTH1), 2-mm coronal tissue height, 3-mm coronal tissue height (CTH3), and one intact tooth (IT) group. Following endodontic treatment of an over-flared canal, the postspace depth was 10 mm, and the residual dentin thickness was 1 mm. Two prefabricated fiberglass posts were cemented into the root canal, adopting a multipost approach. The static load was applied at 0.5 mm/min and 135° concerning the tooth’s longitudinal axis until a fracture occurred. One-way analysis of variance and the post hoc Tukey’s test were performed to analyze the data at a significance level of . Results. The maximum fracture strength was recorded for IT (control group), while the minimum fracture strength was found for teeth with a coronal tissue height of 1 mm. The differences between IT group and other groups ( ), as well as the differences between the group with CTH3 and groups without coronal tissue and CTH1, were significant. Conclusion. In sum, an increase in the height of the remaining coronal tissue (≥3 mm) significantly increased the fracture strength of over-flared endodontically treated central incisors after restoration with prefabricated fiberglass posts by adopting a multipost approach.
- Open Access
- 15 November 2022
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 16  (3) , 159-163
Comparison of the effect of preheating on the flexural strength of giomer and nanohybrid composite resin
Background. Considering the increased use of preheating and novel resin-based materials to restore teeth, the present study investigated the impact of preheating on the flexural strength of a giomer and compared it with a nanohybrid composite resin. Methods. Two restorative materials (Beautifil II giomer and Alpha III nanohybrid composite resin) were used. Thirty rod-shaped samples (adding up to 60 samples) were prepared from the materials above and divided into two subgroups: with and without preheating (n=15). Before sample preparation, the giomer and nanohybrid composite resin tubes were preheated at 68ºC for 15 minutes in the preheating subgroups. In the subgroups without preheating, the tubes were kept in a room at 25ºC. Then the flexural strength was compared between the two groups with two-way ANOVA at a significance level of P<0.05. Results. The results showed significantly higher flexural strength in the preheated subgroups than in the non-preheated subgroups (P<0.001). In addition, the mean flexural strength values were significantly higher in the giomer groups than in the nanohybrid composite resin groups (P<0.001). Conclusion. Preheating increased the studied materials’ flexural strengths significantly. The flexural strength of the giomer restorative material was higher than that of the nanohybrid composite resin, irrespective of preheating.
- 15 November 2022
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 16  (3) , 159-163
Open AccessComparison of the effect of preheating on the flexural strength of giomer and nanohybrid composite resin
Background. Considering the increased use of preheating and novel resin-based materials to restore teeth, the present study investigated the impact of preheating on the flexural strength of a giomer and compared it with a nanohybrid composite resin. Methods. Two restorative materials (Beautifil II giomer and Alpha III nanohybrid composite resin) were used. Thirty rod-shaped samples (adding up to 60 samples) were prepared from the materials above and divided into two subgroups: with and without preheating (n=15). Before sample preparation, the giomer and nanohybrid composite resin tubes were preheated at 68ºC for 15 minutes in the preheating subgroups. In the subgroups without preheating, the tubes were kept in a room at 25ºC. Then the flexural strength was compared between the two groups with two-way ANOVA at a significance level of P<0.05. Results. The results showed significantly higher flexural strength in the preheated subgroups than in the non-preheated subgroups (P<0.001). In addition, the mean flexural strength values were significantly higher in the giomer groups than in the nanohybrid composite resin groups (P<0.001). Conclusion. Preheating increased the studied materials’ flexural strengths significantly. The flexural strength of the giomer restorative material was higher than that of the nanohybrid composite resin, irrespective of preheating.
- Open Access
- 2 December 2020
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 14  (4) , 262
Correction to: Comparison of the effect of bleaching with 15% carbamide peroxide and 35% hydrogen peroxide on flexural strength of Cention N in self-cured and dual-cured polymerization modes
Correction to: Comparison of the effect of bleaching with 15% carbamide peroxide and 35% hydrogen peroxide on flexural strength of Cention N in self-cured and dual-cured polymerization modes
- 2 December 2020
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 14  (4) , 262
Open AccessCorrection to: Comparison of the effect of bleaching with 15% carbamide peroxide and 35% hydrogen peroxide on flexural strength of Cention N in self-cured and dual-cured polymerization modes
Correction to: Comparison of the effect of bleaching with 15% carbamide peroxide and 35% hydrogen peroxide on flexural strength of Cention N in self-cured and dual-cured polymerization modes
- Open Access
- 17 June 2020
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 14  (2) , 105-109
Comparison of the effect of bleaching with 15% carbamide peroxideand 35% hydrogen peroxide on flexural strength of Cention N in selfcuredand dual-cured polymerization modes
Background. The use of bleaching agents might result in microstructural changes in tooth structure andin restorative materials. This study compared the effects of bleaching with %15 carbamide peroxide and%35 hydrogen peroxide on the flexural strength of Cention N restorative material using the self-curedand dual-cured polymerization modes. Methods. Sixty bar-shaped samples of Cention N restorative material were included in this in vitrostudy and assigned to three groups (n=20) randomly: control, bleaching with %15 carbamide peroxideand bleaching with %35 hydrogen peroxide. Each group was divided into two subgroups: samplespolymerized in the self-cured mode and samples polymerized in the dual-cured mode. Then the flexuralstrengths of the samples were determined. Two-way ANOVA was used to compare flexural strengthsbetween the three groups in two polymerization modes, followed by post hoc Tukey test. Statisticalsignificance was defined at PResults. The difference in the mean flexural strength was significant in terms of the bleaching regimen(PConclusion. The application of %15 carbamide peroxide and %35 hydrogen peroxide bleaching agentsdecreased the flexural strength of Cention N restorative material. Irrespective of the bleaching regimen,there was no significant difference in the flexural strength of Cention N between the self-curing anddual-curing polymerization modes.
- 17 June 2020
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 14  (2) , 105-109
Open AccessComparison of the effect of bleaching with 15% carbamide peroxideand 35% hydrogen peroxide on flexural strength of Cention N in selfcuredand dual-cured polymerization modes
Background. The use of bleaching agents might result in microstructural changes in tooth structure andin restorative materials. This study compared the effects of bleaching with %15 carbamide peroxide and%35 hydrogen peroxide on the flexural strength of Cention N restorative material using the self-curedand dual-cured polymerization modes. Methods. Sixty bar-shaped samples of Cention N restorative material were included in this in vitrostudy and assigned to three groups (n=20) randomly: control, bleaching with %15 carbamide peroxideand bleaching with %35 hydrogen peroxide. Each group was divided into two subgroups: samplespolymerized in the self-cured mode and samples polymerized in the dual-cured mode. Then the flexuralstrengths of the samples were determined. Two-way ANOVA was used to compare flexural strengthsbetween the three groups in two polymerization modes, followed by post hoc Tukey test. Statisticalsignificance was defined at PResults. The difference in the mean flexural strength was significant in terms of the bleaching regimen(PConclusion. The application of %15 carbamide peroxide and %35 hydrogen peroxide bleaching agentsdecreased the flexural strength of Cention N restorative material. Irrespective of the bleaching regimen,there was no significant difference in the flexural strength of Cention N between the self-curing anddual-curing polymerization modes.
- 1 August 2017
- Published by Jaypee Brothers Medical Publishing in World Journal of Dentistry
- Vol. 8  (4) , 288-295
Effect of 15% Carbamide Peroxide on the Surface Roughness and Adhesion of Streptococcus mutans to Microhybrid Composite Resin and Giomer
Introduction Adhesion of bacteria, especially Streptococcus mutans (S. mutans), to the surface of tooth restorations is a factor in the etiology of secondary caries. Given the ever-increasing popularity of bleaching procedures, the aim of the present study was to evaluate adhesion of S. mutans and surface roughness (SR) of microhybrid composite resin and giomer subsequent to the application of 15% carbamide peroxide. Materials and methods Twenty disk-shaped samples were prepared from each material, measuring 8 mm in diameter and 2 mm in thickness. Then, the samples of each material were divided into two groups (n = 10): (a) microhybrid without bleaching; (b) microhybrid with bleaching; and (c) giomer without bleaching; and (d) giomer with bleaching. The samples in groups I and III were immersed in artificial saliva for 14 days without any bleaching procedure; the samples in groups II and IV underwent a bleaching procedure on their polished surfaces with 15% carbamide peroxide for 14 days (4 hours of bleaching and 20 hours of immersion in artificial saliva). The SR of all the samples was determined with the use of a profilometer. The samples were added to the culture medium after 4 hours of placement in a microbial suspension at 37°C; after 24 hours of incubation at 37°C, the bacterial counts, indicating the number of bacteria adhering to the surface, were determined by counting them in the plates containing the solid culture medium. Results The type of the restorative material had a significant effect on SR, with greater SR in giomer (p = 0.03). However, bleaching had no significant effect on SR (p = 0.099). In relation to the rate of bacterial adhesion (BA), both the types of the restorative materials and bleaching procedures were significantly effective; in this context, there was more BA in microhybrid composite resin samples that did not undergo bleaching (p < 0.001). Bleaching resulted in the adhesion of S. mutans to the surface of both materials decrease. Pearson's correlation coefficient did not reveal any correlation between BA and SR (p = 0.42). Conclusion The BA was higher in microhybrid composite resin, and SR was higher in giomer. The BA was higher in samples that did not undergo a bleaching procedure. Clinical significance There is no change in the SR of microhybrid composite resin and giomer after application of 15% carbamide peroxide; therefore, it is not necessary to polish or replace these restorative materials after bleaching. In addition, use of 15% carbamide peroxide does not increase caries risk. How to cite this article Mohammadi N, Mowlaie S, Savadi- Oskoee S, Ebrahimi ME, Rikhtegaran S, Rahbar M, Pirzadeh T. Effect of 15% Carbamide Peroxide on the Surface Roughness and Adhesion of Streptococcus mutans to Microhybrid Composite Resin and Giomer. World J Dent 2017;8(4):288-295.
- 1 August 2017
- Published by Jaypee Brothers Medical Publishing in World Journal of Dentistry
- Vol. 8  (4) , 288-295
Effect of 15% Carbamide Peroxide on the Surface Roughness and Adhesion of Streptococcus mutans to Microhybrid Composite Resin and Giomer
Introduction Adhesion of bacteria, especially Streptococcus mutans (S. mutans), to the surface of tooth restorations is a factor in the etiology of secondary caries. Given the ever-increasing popularity of bleaching procedures, the aim of the present study was to evaluate adhesion of S. mutans and surface roughness (SR) of microhybrid composite resin and giomer subsequent to the application of 15% carbamide peroxide. Materials and methods Twenty disk-shaped samples were prepared from each material, measuring 8 mm in diameter and 2 mm in thickness. Then, the samples of each material were divided into two groups (n = 10): (a) microhybrid without bleaching; (b) microhybrid with bleaching; and (c) giomer without bleaching; and (d) giomer with bleaching. The samples in groups I and III were immersed in artificial saliva for 14 days without any bleaching procedure; the samples in groups II and IV underwent a bleaching procedure on their polished surfaces with 15% carbamide peroxide for 14 days (4 hours of bleaching and 20 hours of immersion in artificial saliva). The SR of all the samples was determined with the use of a profilometer. The samples were added to the culture medium after 4 hours of placement in a microbial suspension at 37°C; after 24 hours of incubation at 37°C, the bacterial counts, indicating the number of bacteria adhering to the surface, were determined by counting them in the plates containing the solid culture medium. Results The type of the restorative material had a significant effect on SR, with greater SR in giomer (p = 0.03). However, bleaching had no significant effect on SR (p = 0.099). In relation to the rate of bacterial adhesion (BA), both the types of the restorative materials and bleaching procedures were significantly effective; in this context, there was more BA in microhybrid composite resin samples that did not undergo bleaching (p < 0.001). Bleaching resulted in the adhesion of S. mutans to the surface of both materials decrease. Pearson's correlation coefficient did not reveal any correlation between BA and SR (p = 0.42). Conclusion The BA was higher in microhybrid composite resin, and SR was higher in giomer. The BA was higher in samples that did not undergo a bleaching procedure. Clinical significance There is no change in the SR of microhybrid composite resin and giomer after application of 15% carbamide peroxide; therefore, it is not necessary to polish or replace these restorative materials after bleaching. In addition, use of 15% carbamide peroxide does not increase caries risk. How to cite this article Mohammadi N, Mowlaie S, Savadi- Oskoee S, Ebrahimi ME, Rikhtegaran S, Rahbar M, Pirzadeh T. Effect of 15% Carbamide Peroxide on the Surface Roughness and Adhesion of Streptococcus mutans to Microhybrid Composite Resin and Giomer. World J Dent 2017;8(4):288-295.
- Open Access
- 1 January 2016
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 8  (4) , e373-e378
Effect of pre-heating on the mechanical properties of silorane-based and methacrylate-based composites
The use of composites in dental restoration has been commonly criticized, due to their underwhelming mechanical properties. This problem may be solved partially by preheating. The present research aims to determine the effect of preheating on the mechanical properties of two different classes of composites. A Silorane-based (Silorane) and a Methacrylate-based (Z250) composite were preheated to different temperatures (25, 37, and 68 °C) and afterwards were tested with the appropriate devices for each testing protocol. The material’s flexural strength, elastic modulus, and Vickers microhardness were evaluated. Two-way ANOVA, and Tukey’s post hoc were used to analyze the data. Microhardness and elastic modulus increased with preheating, while flexural strength values did not increase significantly with preheating. Furthermore the methacrylate-based composite (Z250) showed higher values compared to the Silorane-based composite (Silorane) in all the tested properties. Preheating Silorane enhances the composite’s microhardness and elastic modulus but does not affect its flexural strength. On the other hand, preheating Z250 increases its microhardness but does not change its flexural strength or elastic modulus. In addition, the Z250 composite shows higher microhardness and flexural strength than Silorane, but the elastic modulus values with preheating are similar. Therefore Z250 seems to have better mechanical properties making it the better choice in a clinical situation. Key words:Composite, elastic modulus, flexural strength, microhardness, preheating.
- 1 January 2016
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 8  (4) , e373-e378
Open AccessEffect of pre-heating on the mechanical properties of silorane-based and methacrylate-based composites
The use of composites in dental restoration has been commonly criticized, due to their underwhelming mechanical properties. This problem may be solved partially by preheating. The present research aims to determine the effect of preheating on the mechanical properties of two different classes of composites. A Silorane-based (Silorane) and a Methacrylate-based (Z250) composite were preheated to different temperatures (25, 37, and 68 °C) and afterwards were tested with the appropriate devices for each testing protocol. The material’s flexural strength, elastic modulus, and Vickers microhardness were evaluated. Two-way ANOVA, and Tukey’s post hoc were used to analyze the data. Microhardness and elastic modulus increased with preheating, while flexural strength values did not increase significantly with preheating. Furthermore the methacrylate-based composite (Z250) showed higher values compared to the Silorane-based composite (Silorane) in all the tested properties. Preheating Silorane enhances the composite’s microhardness and elastic modulus but does not affect its flexural strength. On the other hand, preheating Z250 increases its microhardness but does not change its flexural strength or elastic modulus. In addition, the Z250 composite shows higher microhardness and flexural strength than Silorane, but the elastic modulus values with preheating are similar. Therefore Z250 seems to have better mechanical properties making it the better choice in a clinical situation. Key words:Composite, elastic modulus, flexural strength, microhardness, preheating.
- Open Access
- 1 January 2015
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 7  (5) , e595-e599
Effect of sodium ascorbate on the bond strength of all-in-one adhesive systems to NaOCl-treated dentin
Ascorbic acid and its salts are low-toxicity products, which are routinely used in food industries as antioxidants. The aim of the present study was to evaluate the effect of 10% sodium ascorbate on the bond strength of two all-in-one adhesive systems to NaOCl-treated dentin.After exposing the dentin on the facial surface of 90 sound human premolars and mounting in an acrylic resin mold, the exposed dentin surfaces were polished with 600-grit SiC paper under running water. Then the samples were randomly divided into 6 groups of 15. Groups 1 and 4 were the controls, in which no surface preparation was carried out. In groups 2 and 5 the dentin surfaces were treated with 5.25% NaOCl alone for 10 minutes and in groups 3 and 6 with 5.25% NaOCl for 10 minutes followed by 10% sodium ascorbate for 10 minutes. Then composite resin cylinders, measuring 2 mm in diameter and 2 mm in height, were bonded on the dentin surfaces in groups 1, 2 and 3 with Clearfil S3 Bond and in groups 4, 5 and 6 with Adper Easy One adhesive systems according to manufacturers' instructions. The samples were stored in distilled water for 24 hours at 37°C and then thermocycled. Finally, the samples underwent shear bond strength test in a universal testing machine at a strain rate of 1 mm/min. Data were analyzed with two-way ANOVA and post hoc Tukey tests at α=0.05.The differences between groups 1 and 2 (P=0.01), 1 and 5 (P=0.003). 1 and 6 (P=0.03) and 4 and 5 (P=0.03) were statistically significant. Two-by-two comparisons did not reveal any significant difference between other groups (P>0.05).Use of 10% sodium ascorbate for 10 minutes restored the decreased bond strength of the adhesive systems to that of the control groups. Key words:Sodium ascorbate, adhesive systems, all-in-one, bond strength, sodium hypochlorite.
- 1 January 2015
- Published by Medicina Oral, S.L. in Journal of Clinical and Experimental Dentistry
- Vol. 7  (5) , e595-e599
Open AccessEffect of sodium ascorbate on the bond strength of all-in-one adhesive systems to NaOCl-treated dentin
Ascorbic acid and its salts are low-toxicity products, which are routinely used in food industries as antioxidants. The aim of the present study was to evaluate the effect of 10% sodium ascorbate on the bond strength of two all-in-one adhesive systems to NaOCl-treated dentin.After exposing the dentin on the facial surface of 90 sound human premolars and mounting in an acrylic resin mold, the exposed dentin surfaces were polished with 600-grit SiC paper under running water. Then the samples were randomly divided into 6 groups of 15. Groups 1 and 4 were the controls, in which no surface preparation was carried out. In groups 2 and 5 the dentin surfaces were treated with 5.25% NaOCl alone for 10 minutes and in groups 3 and 6 with 5.25% NaOCl for 10 minutes followed by 10% sodium ascorbate for 10 minutes. Then composite resin cylinders, measuring 2 mm in diameter and 2 mm in height, were bonded on the dentin surfaces in groups 1, 2 and 3 with Clearfil S3 Bond and in groups 4, 5 and 6 with Adper Easy One adhesive systems according to manufacturers' instructions. The samples were stored in distilled water for 24 hours at 37°C and then thermocycled. Finally, the samples underwent shear bond strength test in a universal testing machine at a strain rate of 1 mm/min. Data were analyzed with two-way ANOVA and post hoc Tukey tests at α=0.05.The differences between groups 1 and 2 (P=0.01), 1 and 5 (P=0.003). 1 and 6 (P=0.03) and 4 and 5 (P=0.03) were statistically significant. Two-by-two comparisons did not reveal any significant difference between other groups (P>0.05).Use of 10% sodium ascorbate for 10 minutes restored the decreased bond strength of the adhesive systems to that of the control groups. Key words:Sodium ascorbate, adhesive systems, all-in-one, bond strength, sodium hypochlorite.
- 20 July 2013
- Published by Springer Nature in Lasers in Medical Science
- Vol. 30  (2) , 653-659
Effect of different mechanical and chemical surface treatments on the repaired bond strength of an indirect composite resin
This study compared the effects of two mechanical surface preparation techniques, air abrasion and Nd:YAG laser, with the use of two adhesive systems, self-etch and etch and rinse, on the repair bond strengths of an indirect composite resin. One hundred fifty cylindrical samples of an indirect composite resin were prepared and randomly divided into six groups (n = 25). In groups 1–3, the composite resin surfaces were respectively prepared as follows: no roughening, roughening by air abrasion, and roughening by Nd:YAG laser, followed by application of an etch-and-rinse adhesive. In groups 4–6, the preparation techniques were respectively the same as those in groups 1–3, followed by application of a self-etch adhesive. Subsequently, a direct composite resin was added and repair bond strengths were measured. Data were analyzed with two-way ANOVA and post hoc Tukey's test. Mean bond strength value was significant based on the preparation technique (P < 0.001), i.e., in air abrasion and Nd:YAG laser groups, bond strengths were significantly higher compared to no-preparation groups (P < 0.0005). There were significant differences in bond strength values between air abrasion and Nd:YAG laser groups, with significantly higher values in air abrasion groups (P < 0.0005). However, there were no significant differences in bond strength values between the adhesive systems. Furthermore, the cumulative effects of the adhesive system and the surface preparation technique were not significant. Surface preparation of the indirect composite resin with air abrasion and Nd:YAG laser resulted in a significant increase in the repair bond strength, with air abrasion being more effective. There were no significant differences in bond strength between the two adhesives.
- 20 July 2013
- Published by Springer Nature in Lasers in Medical Science
- Vol. 30  (2) , 653-659
Effect of different mechanical and chemical surface treatments on the repaired bond strength of an indirect composite resin
This study compared the effects of two mechanical surface preparation techniques, air abrasion and Nd:YAG laser, with the use of two adhesive systems, self-etch and etch and rinse, on the repair bond strengths of an indirect composite resin. One hundred fifty cylindrical samples of an indirect composite resin were prepared and randomly divided into six groups (n = 25). In groups 1–3, the composite resin surfaces were respectively prepared as follows: no roughening, roughening by air abrasion, and roughening by Nd:YAG laser, followed by application of an etch-and-rinse adhesive. In groups 4–6, the preparation techniques were respectively the same as those in groups 1–3, followed by application of a self-etch adhesive. Subsequently, a direct composite resin was added and repair bond strengths were measured. Data were analyzed with two-way ANOVA and post hoc Tukey's test. Mean bond strength value was significant based on the preparation technique (P < 0.001), i.e., in air abrasion and Nd:YAG laser groups, bond strengths were significantly higher compared to no-preparation groups (P < 0.0005). There were significant differences in bond strength values between air abrasion and Nd:YAG laser groups, with significantly higher values in air abrasion groups (P < 0.0005). However, there were no significant differences in bond strength values between the adhesive systems. Furthermore, the cumulative effects of the adhesive system and the surface preparation technique were not significant. Surface preparation of the indirect composite resin with air abrasion and Nd:YAG laser resulted in a significant increase in the repair bond strength, with air abrasion being more effective. There were no significant differences in bond strength between the two adhesives.
- 1 March 2013
- Published by Operative Dentistry in Operative Dentistry
- Vol. 38  (2) , 218-225
Effect of Delaying Toothbrushing During Bleaching on Enamel Surface Roughness: An In Vitro Study
SUMMARY: This study aimed to evaluate the effect of toothbrushing on enamel surface roughness at three different intervals after daily bleaching treatment. Eighty enamel slabs were initially evaluated for surface roughness and then randomly divided into four groups. The bleaching procedure was carried out for 21 days, six hours daily. In the control group (group 1), the specimens were not brushed after bleaching, but in groups 2–4, they were brushed with toothpaste immediately, one hour, or two hours after bleaching, respectively. Then the specimens were stored in artificial saliva. Enamel surface roughness was reevaluated at the end of the period. Kruskal-Wallis and Mann-Whitney U tests showed statistically significant differences in the means of surface roughness values between the immediately brushed group and the three other groups (p<0.001). Daily toothbrushing immediately after bleaching increased enamel surface roughness; however, postponing the procedure for one or two hours after daily bleaching and exposing the specimens to artificial saliva during the study period resulted in enamel surface roughness comparable to that of the control group.
- 1 March 2013
- Published by Operative Dentistry in Operative Dentistry
- Vol. 38  (2) , 218-225
Effect of Delaying Toothbrushing During Bleaching on Enamel Surface Roughness: An In Vitro Study
SUMMARY: This study aimed to evaluate the effect of toothbrushing on enamel surface roughness at three different intervals after daily bleaching treatment. Eighty enamel slabs were initially evaluated for surface roughness and then randomly divided into four groups. The bleaching procedure was carried out for 21 days, six hours daily. In the control group (group 1), the specimens were not brushed after bleaching, but in groups 2–4, they were brushed with toothpaste immediately, one hour, or two hours after bleaching, respectively. Then the specimens were stored in artificial saliva. Enamel surface roughness was reevaluated at the end of the period. Kruskal-Wallis and Mann-Whitney U tests showed statistically significant differences in the means of surface roughness values between the immediately brushed group and the three other groups (p<0.001). Daily toothbrushing immediately after bleaching increased enamel surface roughness; however, postponing the procedure for one or two hours after daily bleaching and exposing the specimens to artificial saliva during the study period resulted in enamel surface roughness comparable to that of the control group.
- 28 February 2012
- Published by Springer Nature in Lasers in Medical Science
- Vol. 28  (1) , 65-69
Effect of Er,Cr:YSGG pretreatment on bond strength of fiber posts to root canal dentin using a self-adhesive resin cement
The weak link in the adhesive luting of fiber posts to root canal dentin is at the cement–dentin interface. The aim of the present study was to evaluate the effect of Er,Cr:YSGG laser irradiation on push-out bond strength of fiber posts cemented to root canal dentin using a self-adhesive cement. A total of 30 sound human maxillary central incisors were equally divided into two groups after root canal treatment, decoronation and preparation of the post space. Teeth of group 1 were treated with the Er,Cr:YSGG laser, and teeth of group 2 (control) received no laser treatment. After cementation of fiber posts with Maxcem self-adhesive cement, 3-mm cervical, middle and apical sections were prepared from the roots. Then a push-out test was performed using a universal testing machine at a strain rate of 0.5 mm/min. Data were analyzed using two-way ANOVA and the Bonferroni test. Statistical significance was defined as P < 0.05. There was a significant difference in the mean bond strength values between groups 1 and 2 (P = 0.001), but there were no significant differences between the various root parts (P = 0.14). In addition, the cumulative effects of dentin treatment type and various root parts were not statistically significant (P = 0.41). The mean bond strength in the laser group was significantly higher than in the control group (P = 0.001, post hoc Bonferroni test).The failure mode was evaluated under a stereomicroscope at ×20 magnification.
- 28 February 2012
- Published by Springer Nature in Lasers in Medical Science
- Vol. 28  (1) , 65-69
Effect of Er,Cr:YSGG pretreatment on bond strength of fiber posts to root canal dentin using a self-adhesive resin cement
The weak link in the adhesive luting of fiber posts to root canal dentin is at the cement–dentin interface. The aim of the present study was to evaluate the effect of Er,Cr:YSGG laser irradiation on push-out bond strength of fiber posts cemented to root canal dentin using a self-adhesive cement. A total of 30 sound human maxillary central incisors were equally divided into two groups after root canal treatment, decoronation and preparation of the post space. Teeth of group 1 were treated with the Er,Cr:YSGG laser, and teeth of group 2 (control) received no laser treatment. After cementation of fiber posts with Maxcem self-adhesive cement, 3-mm cervical, middle and apical sections were prepared from the roots. Then a push-out test was performed using a universal testing machine at a strain rate of 0.5 mm/min. Data were analyzed using two-way ANOVA and the Bonferroni test. Statistical significance was defined as P < 0.05. There was a significant difference in the mean bond strength values between groups 1 and 2 (P = 0.001), but there were no significant differences between the various root parts (P = 0.14). In addition, the cumulative effects of dentin treatment type and various root parts were not statistically significant (P = 0.41). The mean bond strength in the laser group was significantly higher than in the control group (P = 0.001, post hoc Bonferroni test).The failure mode was evaluated under a stereomicroscope at ×20 magnification.