SKSoodabeh Kimyai

Soodabeh Kimyai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Soodabeh Kimyai has a total of 160 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of the Cytotoxicity and Anti-inflammatory Properties of Glass Ionomer Cement Containing Titanium Dioxide Nanoparticles

    by Zahra Gholami, Zoleikha Asadi, Soodabeh Kimyai, Simin Sharifi, Solmaz Maleki Dizaj, Elmira Jafari Navimipour, Mohammad Esmaeel Ebrahimi Chaharom, Fathemeh Dabaghi Tabriz

    Introduction: Glass Ionomer Cements (GICs) modified with bioactive Nanoparticles (NPs) have emerged as promising materials for enhanced performance in restorative dentistry. This study aimed to evaluate the cytotoxicity and anti-inflammatory properties of a novel GIC formulation incorporating titanium dioxide (TiO 2 ) nanoparticles. Methods: In this in vitro investigation, TiO 2 NPs were incorporated into conventional GIC powder (Fuji II) at a concentration of 1 wt%. Human Gingival Fibroblasts (HGFs) were cultured in Dulbecco’s Modified Eagle Medium (DMEM) supplemented with Fetal Bovine Serum (FBS) and antibiotics. Cytotoxicity was assessed using the MTT assay at 24, 48, and 72 hours following exposure to the modified and unmodified GIC. To evaluate anti-inflammatory effects, HGFs were treated with either conventional GIC or TiO 2 -modified GIC for 24 hours. Untreated cells served as the control group. Following treatment, all groups were stimulated with 45 µg/mL lipopolysaccharide (LPS) to induce an inflammatory response. The concentrations of IL-6 and TNF-α were quantified using sandwich ELISA kits. Statistical analysis was performed using one-way and two-way ANOVA followed by Tukey’s post hoc test, with significance set at p < 0.05. Results: The incorporation of TiO 2 NPs did not significantly alter the cytotoxicity of GIC ( p > 0.05). Both modified and unmodified GICs exhibited cytotoxic effects within the first 24 hours, with cell viability ranging from 55% to 60%. No significant differences in cytotoxicity were observed across the 24, 48, and 72-hour time points ( p > 0.05). LPS stimulation significantly elevated IL-6 and TNF-α levels in all groups ( p < 0.001), confirming robust immune activation. Notably, conventional GIC further enhanced IL-6 production in the presence of LPS ( p < 0.01). In contrast, TiO 2 -modified GIC significantly attenuated the expression of both cytokines under inflammatory conditions ( p < 0.01). Under non-stimulated conditions, cytokine levels remained low and did not differ significantly from the control group. Discussion: The findings suggest that the addition of low-dose TiO 2 NPs does not exacerbate the cytotoxic effects of GIC and may confer anti-inflammatory benefits, thereby enhancing the biological performance of GICs in restorative applications. Conclusion: The presence of TiO 2 NPs significantly decreased the expression of proinflammatory cytokines, suggesting a potential immunomodulatory benefit.

  • Open Access

    Effect of blood decontamination methods on dentin bond strength across adhesive systems: a systematic review

    by Katayoun Katebi, Soodabeh Kimyai, Fatemeh Salehnia, Hosein Azizi

    This systematic review aimed to investigate the effect of different blood decontamination methods on dentin bond strength across various adhesive systems. This systematic review was conducted in accordance with PRISMA 2020 guidelines and registered in PROSPERO (CRD42022381287). A comprehensive electronic search of Medline/PubMed, Web of Science, Scopus, and Embase was performed up to February 26, 2026. In vitro studies evaluating the effect of blood decontamination methods on dentin bond strength were included. Risk of bias was assessed using the QUIN tool. A qualitative synthesis was conducted. by stratifying the results based on decontamination method and adhesive systems. Fifteen in vitro studies comprising 1,015 teeth met the inclusion criteria. Eleven studies had low risk of bias, while four demonstrated a moderate risk of bias. Blood contamination consistently reduces dentin bond strength across adhesive systems with the most severe effects occurring when contamination happens after polymerization. Some approaches, such as adhesive reapplication and phosphoric acid re-etching in etch-and-rinse systems, as well as sodium hypochlorite combined with antioxidants, show the most promising results. Blood contamination reduces bond strength to dentin. Although various decontamination methods can partially improve bonding, full recovery to uncontaminated levels is not reliably achieved. The effectiveness of decontamination strategies varied according to adhesive type, contamination timing (before or after adhesive curing), and decontamination protocol.

  • Open Access

    Effect of Brushing with Activated Charcoal Toothpaste on the Color, Surface Roughness, and Microhardness of Enamel: An in Vitro Study

    by Mohammad Esmaeel Ebrahimi Chaharom, Mahsa Vejdani, Mahmoud Bahari, Soodabeh Kimyai, Shokofe Tabatabaei, Mehdi Abed Kahnamouei

    Objective: To evaluate in vitro the effect of brushing with toothpaste containing activated charcoal on the color, surface roughness, and microhardness of enamel. Material and Methods: In this experimental study, 40 human premolars were randomly assigned to four groups based on the type of toothpaste used (distilled water, conventional toothpaste, bleaching toothpaste, or activated charcoal toothpaste). Two enamel slabs were prepared from each tooth (80 slabs). Then 20 g of each toothpaste was dissolved in 40 mL of water for 5 minutes, and the toothpaste was brushed for 14 minutes (equivalent to three months) using an Oral-B electric toothbrush at 200 g of force. After performing the tests, One-way ANOVA and Tukey post hoc tests were used to analyze discoloration and surface roughness, and the Kruskal-Wallis test was used to compare microhardness (p0.05). Conclusion: The change in surface roughness and microhardness of enamel by charcoal toothpaste was negligible. The bleaching properties of charcoal toothpaste were greater than those of bleaching toothpaste.

  • Open Access

    Effect of polyacrylic acid pretreatment before CPP-ACP application in remineralization of demineralized root dentin: An in vitro study

    by Arezoo Ghasemi, Elmira Jafari Navimipour, Soodabeh Kimyai, Parnian Alizadeh Oskuee, Mehdi Daneshpooy, Ziba Islambulchilar, Sevda Riyahifar

    Background. This study evaluated the efficacy of polyacrylic acid (PAA) pretreatment before application of casein phosphopeptide–amorphous calcium phosphate (CPP-ACP) in remineralizing demineralized root dentin. Methods. Thirty-nine dentin specimens from extracted human third molars were prepared. All the specimens were standardized for Vickers microhardness at baseline (VHNba). Then the specimens were randomly divided into three groups (n=13): (1) untreated demineralized dentin, (2) CPP-ACP treatment, and (3) PAA pretreatment before CPP-ACP application. All the specimens were subjected to 72 hours of demineralization. Subsequently, treatments were administered according to group protocols and a 28-day pH-cycling regimen. Then, Vickers microhardness (VHN) was assessed after demineralization (VHNde) and after treatment (VHNre). The difference between VHNre and VHNde was calculated as ΔVHN and compared between the groups. Data were analyzed using one-way ANOVA, repeated-measures ANOVA, and post hoc Bonferroni tests (P<0.05). Results. Demineralization significantly decreased dentin microhardness in all the groups (P<0.001). In contrast, microhardness values increased significantly after applying the treatment protocol (P<0.001). Specimens that received PAA pretreatment before CPP-ACP application showed a considerably higher ΔVHN than those treated with CPP-ACP alone (P<0.0001). However, neither group returned to the initial values. Conclusion. Applying CPP-ACP, either alone or after pretreatment with PAA, increased the microhardness of demineralized root dentin and promoted remineralization. Pretreatment with PAA enhanced this remineralization effect, suggesting its potential use in conservative dentin treatment strategies.

  • Open Access

    Evaluation of the color-matching potentials of different universal composite resins with natural tooth structure in class III through-and-through cavities using a visual guide and spectrophotometer

    by Mahmoud Bahari, Mahdi Abed Kahnamouei, Fatemeh Pournaghi Azar, Soodabeh Kimyai, Kiana Tadayon

    Background. This study assessed the color-matching potentials of Omnichroma single-shade composite resin and Omnichroma Blocker with natural tooth structure in Class III through-and-through restorations and compared them with a universal multi-shade composite resin using both visual and spectrophotometric evaluations. Methods. Class III through-and-through cavities were prepared on the mesial and distal aspects of 32 extracted anterior teeth. Each preparation was restored with either Omnichroma composite resin or Tetric Evoceram composite resin, with or without an 0.5-mm depth of Omnichroma Blocker on the lingual aspect. Color measurements were performed initially and after restoration using visual evaluation with the VITA Classical Shade Guide and the SpectroShade microspectrophotometer. Color differences were calculated using the CIEDE2000 formula. Results. Tetric Evoceram with and without blocker exhibited a statistically significant difference in color match with natural tooth structure (P=0.02). The color-matching difference with natural teeth was statistically significant in the visual evaluation (P=0.005). Conclusion. Failing to use a blocker with Tetric Evoceram composite resin in large Class III cavities reduced color matching. In contrast, using a blocker with Omnichroma composite resin did not affect the final color-matching ability. Furthermore, the Omnichroma composite resin demonstrated better visual color matching, regardless of the presence of a blocker, than the Tetric Evoceram composite resin.

  • Open Access

    Effect of bleaching and re-polishing on saffron, turmeric, and black pepper stain removal from anterior composite veneering material

    by Fathemeh Dabaghi Tabriz, Katayoun Katebi, Seyedeh Neda Bahiji, Soodabeh Kimyai

    Background. This in vitro experimental study evaluated the color stability and effect of bleaching and re-polishing Gaenial, nanohybrid veneering composite resin material, following immersion in saffron, turmeric, and black pepper solutions. Methods. Sixty disk-shaped composite resin samples were prepared and randomly assigned to four groups (n=15). The samples were immersed in saffron, turmeric, and black pepper solutions for seven days. Color parameters were assessed using a spectrophotometer before immersion and after seven days. Following immersion, one side of each sample underwent a bleaching treatment, while the opposite side was re-polished. Two-way ANOVA and independent t-test were used to evaluate the effectiveness of the bleaching and re-polishing procedures to remove stains from the composite resin samples. Data analysis was conducted using SPSS 17. Results. The groups exhibited statistically significant differences (P<0.001). Turmeric solution showed the highest discoloration compared to the other two solutions, followed by saffron, with black pepper demonstrating the least stainability. In the saffron group, no statistically significant difference was observed between the bleaching and re-polishing treatments (P=0.06). Conversely, in the turmeric and black pepper groups, there were statistically significant differences between bleaching and re-polishing (P<0.001). In the control group, no statistically significant difference was found between the bleaching and re-polishing treatments (P=0.378). Conclusion. The effectiveness of bleaching and re-polishing varied across the groups. In both the turmeric and black pepper groups, bleaching was more effective in reducing discoloration than re-polishing. Conversely, no statistically significant difference was found between bleaching and re-polishing treatments in the saffron group.

  • Open Access

    Effect of different bleaching protocols on the color and translucency parameters of a new monochromatic universal composite resin

    by Mohammad Esmaeel Ebrahimi Chaharom, Mahmoud Bahari, Soodabeh Kimyai, Helia Bagban Nikzad

    Background. Considering the few studies on the effect of bleaching protocols on the color properties of a newly developed monochromatic universal composite resin, the present study evaluated the effect of different bleaching protocols on the color change and translucency of Omnichroma (OMN) composite resin. Methods. In this laboratory study, 45 cylindrical OMN composite resin disks with a diameter of 10 mm and a thickness of 2 mm were used. The samples were randomly divided into three groups (n=15) based on the bleaching protocols: group 1: 40% hydrogen peroxide (HP) for 20 minutes, twice a day for three sessions one week apart; group 2: 20% carbamide peroxide (CP) for 8 hours a day, for 14 consecutive days; group 3: 40% HP with Nd:YAG laser (HP+Nd:YAG laser) applied on the gel for 30 seconds twice. Baseline and post-bleaching measurements of color parameters were done using a Vita Easyshade spectrophotometer. Data was analyzed using paired-samples t-test, one-way ANOVA, and post hoc Tukey tests (P<0.05). Results. All the bleaching protocols significantly changed the color (P<0.001) and translucency (P<0.001) parameters. CP caused the most color changes (P<0.05) and translucency (P0.05). Conclusion. Bleaching caused a noticeable change in the color and translucency of the OMN composite resin. The effect of the at-home bleaching protocol was greater than the in-office ones.

  • Open Access

    Effect of repeated preheating on color stability of three types of composite resins and a giomer: An in vitro study

    by Mehdi Daneshpooy, Soodabeh Kimyai, Romina Allahyari Sani

    Background. This study assessed the effect of repeated preheating of three types of composite resins and a giomer on their color stability. Methods. In this in vitro study, 128 composite resin and giomer specimens with a 10-mm diameter and a 2-mm height were evaluated in eight groups (n=16) of Heliomolar microfilled, Brilliant Enamel microhybrid, and Tetric N-Ceram nanohybrid composite resins, and Beautifil II giomer used at room temperature and also after preheating of the tube in a water bath at 55‒60 °C for 40 times. After preparing the specimens, their color parameters were measured by a spectrophotometer. The specimens were immersed in a tea solution for 3 hours/day for 40 days and underwent spectrophotometric color assessment again. The color change (∆E) was calculated and analyzed by two-way ANOVA (α=0.05). Results. The effects of composite resin type (P<0.001) and preheating (P<0.001) and their interaction effect (P<0.001) were significant on ∆E. Immersion in a tea solution caused a significantly greater color change in giomer (P<0.05). The ∆E of the microfilled composite resin was significantly higher than that of nanohybrid (P=0.003) and microhybrid composite resin (P=0.004). Conclusion. Repeated preheating of giomer, microhybrid, and nanohybrid composite resin specimens to 55‒60 °C for 40 times adversely affected their color stability in the tea solution. The color change was significantly greater for giomer.


  • Open Access

    Effect of at-home and in-office bleaching on microleakage of class V composite resin restorations using different types of universal adhesives: An in vitro study

    by Mehdi Abed Kahnamouei, Soodabeh Kimyai, Katayoun Katebi, Mohammad Esmaeel Ebrahimi Chaharom, Mehdi Daneshpooy, Mahmoud Bahari, Mahshid Moradi

    Background. When bleaching agents contact dental structures, they act on restorative materials and adhesive interfaces. This study investigated the effect of "at-home" and "in-office" bleaching on the microleakage of composite resin restorations performed with different universal adhesives in self-etch and etch-and-rinse modes. Methods. Class V cavities were prepared in 132 premolars. The samples were divided into four groups (n=33). All Bond Universal adhesive was used in the first and second groups, and G-Premio Bond adhesive was used in the third and fourth groups. The total-etch mode was used in the first and third groups, and the self-etch mode was used in the second and fourth groups. The samples were divided into three subgroups (n=11). In the first subgroup, home bleaching was used, and in the second subgroup, office bleaching was used. In the third subgroup, bleaching was not performed. The specimens were examined under a stereomicroscope for microleakage. Ordinal regression analysis was applied (P<0.05). Results. The adhesive type, application method, and margin type significantly affected microleakage (P0.05). Conclusion. Based on the results of the microleakage test, bleaching after composite resin restorations did not significantly affect the microleakage of Class V restorations.

  • Open Access

    Comparison of the effect of preheating on the flexural strength of giomer and nanohybrid composite resin

    by Soodabeh Kimyai, Zahra Mashayekhi, Narmin Mohammadi, Mahmoud Bahari, Mahdi Abed Kahnamouei, Mohammad Esmaeel Ebrahimi Chaharom

    Background. Considering the increased use of preheating and novel resin-based materials to restore teeth, the present study investigated the impact of preheating on the flexural strength of a giomer and compared it with a nanohybrid composite resin. Methods. Two restorative materials (Beautifil II giomer and Alpha III nanohybrid composite resin) were used. Thirty rod-shaped samples (adding up to 60 samples) were prepared from the materials above and divided into two subgroups: with and without preheating (n=15). Before sample preparation, the giomer and nanohybrid composite resin tubes were preheated at 68ºC for 15 minutes in the preheating subgroups. In the subgroups without preheating, the tubes were kept in a room at 25ºC. Then the flexural strength was compared between the two groups with two-way ANOVA at a significance level of P<0.05. Results. The results showed significantly higher flexural strength in the preheated subgroups than in the non-preheated subgroups (P<0.001). In addition, the mean flexural strength values were significantly higher in the giomer groups than in the nanohybrid composite resin groups (P<0.001). Conclusion. Preheating increased the studied materials’ flexural strengths significantly. The flexural strength of the giomer restorative material was higher than that of the nanohybrid composite resin, irrespective of preheating.