Augusto D. Oliveira
Research Subjects
Augusto D. Oliveira has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- J.Garcia Alves
Universidade de Lisboa (UL), Instituto Superior Técnico (IST), Laboratório de Proteção e Segurança Radiológica (LPSR), Laboratório de Metrologia das Radiações Ionizantes (LMRI), Bobadela LRS, Portugal
5 shared publications - Joao A. M. Santos
Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Institute of Oncology of Porto (IPO Porto), 4200-072 Porto, Portugal
4 shared publications - Anabela Gregório Dias
Instituto Português de Oncologia do Porto Francisco Gentil (IPOPFG) - Medical Physics Service, R. Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal; Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Centre (CI-IPO), Portuguese Oncology Institute of Porto (IPO-Porto), Porto Comprehensive Cancer Center (Porto.CCC) &Rise@CI-IPOP (Health Research Network), Porto, Portugal
3 shared publications - Sandra Sarmento
Medical Physics, Radiobiology and Radiation Protection Group, IPO Porto Research Center (CI-IPOP), Portuguese Oncology Institute of Porto (IPO Porto), Porto, Portugal
3 shared publications - Carlos Oliveira
Instituto Tecnológico e Nuclear, Sacavém, Portugal
2 shared publications J. V. Cardoso
Instituto Superior Técnico (IST), Laboratório de Proteção e Segurança Radiológica (LPSR), Universidade de Lisboa (UL), Estrada Nacional 10 (ao km 139,7), 2695-066, Bobadela LRS, Portugal
2 shared publications
Latest Publications
- 16 April 2019
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 58 (3) , 373-384
Dose to the interventional radiologist in CTF-guided procedures
The aim of this work was to assess the occupational dose received by an interventional radiologist (IR) during computed tomography fluoroscopy (CTF)-guided procedures; to identify the most exposed areas of the body including the hands and fingers; to suggest recommendations for individual monitoring; and to improve radiation safety of the practice. A total of 53 CTF-guided procedures were studied. Twelve whole-body dosimeters were worn by the IR in each procedure for the assessment of the personal dose equivalent, Hp(10), on the chest, waist, and back, both over and under the lead apron, as well as the personal dose equivalent, Hp(0.07), on both arms, knees, and feet. Special gloves with casings to fit extremity dosimeters were prepared to assess Hp(0.07) to the fingers. The measured chest dose values were higher than those on the waist and back; the dominant hand or the left side was the most exposed. In general, the ring, middle, and index fingers of the dominant hand were the most exposed (maximum in the 36–39 mSv range), while wrist dose was negligible compared to finger doses. Based on the results obtained the following recommendations are suggested: protective devices (lead aprons, thyroid shield, and goggles) should be worn; Hp(10) should be assessed at the chest level both above and below the lead apron; finger doses can be measured on the basis of each middle finger; the arm closer to the beam should be monitored; and finally, a wrist dosimeter will not provide useful information.
- 16 April 2019
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 58 (3) , 373-384
Dose to the interventional radiologist in CTF-guided procedures
The aim of this work was to assess the occupational dose received by an interventional radiologist (IR) during computed tomography fluoroscopy (CTF)-guided procedures; to identify the most exposed areas of the body including the hands and fingers; to suggest recommendations for individual monitoring; and to improve radiation safety of the practice. A total of 53 CTF-guided procedures were studied. Twelve whole-body dosimeters were worn by the IR in each procedure for the assessment of the personal dose equivalent, Hp(10), on the chest, waist, and back, both over and under the lead apron, as well as the personal dose equivalent, Hp(0.07), on both arms, knees, and feet. Special gloves with casings to fit extremity dosimeters were prepared to assess Hp(0.07) to the fingers. The measured chest dose values were higher than those on the waist and back; the dominant hand or the left side was the most exposed. In general, the ring, middle, and index fingers of the dominant hand were the most exposed (maximum in the 36–39 mSv range), while wrist dose was negligible compared to finger doses. Based on the results obtained the following recommendations are suggested: protective devices (lead aprons, thyroid shield, and goggles) should be worn; Hp(10) should be assessed at the chest level both above and below the lead apron; finger doses can be measured on the basis of each middle finger; the arm closer to the beam should be monitored; and finally, a wrist dosimeter will not provide useful information.
- Open Access
- 29 November 2017
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (1) , 250-258
The use of needle holders in CTF guided biopsies as a dose reduction tool
Purpose: The purpose of this study was to evaluate the efficacy of needle holders in reducing staff hand exposure during biopsies guided by computed tomography fluoroscopy (CTF), through the analysis of data acquired during a detailed monitoring study, undertaken in parallel with an ongoing optimization process to reduce hand irradiation.Methods: Hand monitoring was performed with 11 extremity detectors, two per finger (base and tip) and one on the back of the wrist, for the left (dominant) hand, during two series of biopsies with comparable characteristics. The first series (47 biopsies) were performed with only quick‐check method (QC) and occasional side‐handle (SH) manipulation of the needle. The second series (63 biopsies) were performed after introducing needle holders (NH) in the course of an optimization process.Results: Choice of technique (QC, QC + NH, QC + SH) by the interventional radiologist (IR) was related to biopsy difficulty. Measured hand exposure was low (< 1 mSv) for all QC‐only procedures, and for most of the QC + NH procedures. Occasional side‐handle manipulation still occurred during challenging biopsies, so that 8% of biopsies in the second series accounted for ~70% of total fingertip dose (~90 mSv). The methodology used allowed a detailed insight into the dose reduction achievable with needle holders during real procedures, without the limitations of phantom measurements.Conclusions: Needle holders proved effective in reducing mean hand exposure during clinical procedures where real‐time manipulation was necessary. Occasional side‐handle manipulation was found to contribute disproportionately to hand exposure. This highlights the importance of individual hand monitoring during CTF guided procedures.
- 29 November 2017
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (1) , 250-258
Open AccessThe use of needle holders in CTF guided biopsies as a dose reduction tool
Purpose: The purpose of this study was to evaluate the efficacy of needle holders in reducing staff hand exposure during biopsies guided by computed tomography fluoroscopy (CTF), through the analysis of data acquired during a detailed monitoring study, undertaken in parallel with an ongoing optimization process to reduce hand irradiation.Methods: Hand monitoring was performed with 11 extremity detectors, two per finger (base and tip) and one on the back of the wrist, for the left (dominant) hand, during two series of biopsies with comparable characteristics. The first series (47 biopsies) were performed with only quick‐check method (QC) and occasional side‐handle (SH) manipulation of the needle. The second series (63 biopsies) were performed after introducing needle holders (NH) in the course of an optimization process.Results: Choice of technique (QC, QC + NH, QC + SH) by the interventional radiologist (IR) was related to biopsy difficulty. Measured hand exposure was low (< 1 mSv) for all QC‐only procedures, and for most of the QC + NH procedures. Occasional side‐handle manipulation still occurred during challenging biopsies, so that 8% of biopsies in the second series accounted for ~70% of total fingertip dose (~90 mSv). The methodology used allowed a detailed insight into the dose reduction achievable with needle holders during real procedures, without the limitations of phantom measurements.Conclusions: Needle holders proved effective in reducing mean hand exposure during clinical procedures where real‐time manipulation was necessary. Occasional side‐handle manipulation was found to contribute disproportionately to hand exposure. This highlights the importance of individual hand monitoring during CTF guided procedures.
- Open Access
- 8 January 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (1) , 316-327
Gafchromic XR‐QA2 film as a complementary dosimeter for hand‐monitoring in CTF‐guided biopsies
Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the base of one finger, while the fingertips may be exposed to the highly collimated CT beam. In this work we have explored the possibility of using Gafchromic XR-QA2 self-developing film as a complementary dosimeter to quantify hand exposure during CTF-guided biopsies. A glove used in a previous study and designed to contain 11 TLDs was adapted to include Gafchromic strips 7 mm wide, covering the fingers. A total of 22 biopsies were successfully performed wearing this GafTLD glove under sterile gloves, and the IR reported no difficulty or reduction of dexterity while wearing it. Comparison of dose distributions obtained from digitization of the Gafchromic film strips and absolute (0.07) readings from TLDs showed good agreement, despite some positional uncertainty due to relative movement. Per procedure, doses at the base of the ring finger can be as low as 3%–8% of hand dose maximum. Accumulated dose at the base of the ring finger was four times lower than the dose maximum. PACS numbers: 07.57.Kp, 29.40.-n, 85.25.Pb, 87.57.qp- 8 January 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (1) , 316-327
Open AccessGafchromic XR‐QA2 film as a complementary dosimeter for hand‐monitoring in CTF‐guided biopsies
Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the base of one finger, while the fingertips may be exposed to the highly collimated CT beam. In this work we have explored the possibility of using Gafchromic XR-QA2 self-developing film as a complementary dosimeter to quantify hand exposure during CTF-guided biopsies. A glove used in a previous study and designed to contain 11 TLDs was adapted to include Gafchromic strips 7 mm wide, covering the fingers. A total of 22 biopsies were successfully performed wearing this GafTLD glove under sterile gloves, and the IR reported no difficulty or reduction of dexterity while wearing it. Comparison of dose distributions obtained from digitization of the Gafchromic film strips and absolute (0.07) readings from TLDs showed good agreement, despite some positional uncertainty due to relative movement. Per procedure, doses at the base of the ring finger can be as low as 3%–8% of hand dose maximum. Accumulated dose at the base of the ring finger was four times lower than the dose maximum. PACS numbers: 07.57.Kp, 29.40.-n, 85.25.Pb, 87.57.qp - 1 November 2015
- Published by Elsevier in Radiation Measurements
- Vol. 82, 138-145
The determination of the focal spot size of an X-ray tube from the radiation beam profile
- 1 November 2015
- Published by Elsevier in Radiation Measurements
- Vol. 82, 138-145
The determination of the focal spot size of an X-ray tube from the radiation beam profile
- 25 November 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 448-452
Preliminary assessment of the dose to the interventional radiologist in fluoro-CT-guided procedures
A preliminary assessment of the occupational dose to the intervention radiologist received in fluoroscopy computerised tomography (CT) used to guide the collection of lung and bone biopsies is presented. The main aim of this work was to evaluate the capability of the reading system as well as of the available whole-body (WB) and extremity dosemeters used in routine monthly monitoring periods to measure per procedure dose values. The intervention radiologist was allocated 10 WB detectors (LiF: Mg, Ti, TLD-100) placed at chest and abdomen levels above and below the lead apron, and at both right and left arms, knees and feet. A special glove was developed with casings for the insertion of 11 extremity detectors (LiF:Mg, Cu, P, TLD-100H) for the identification of the most highly exposed fingers. The Hp(10) dose values received above the lead apron (ranged 0.20–0.02 mSv) depend mainly on the duration of the examination and on the placement of physician relative to the beam, while values below the apron are relatively low. The left arm seems to receive a higher dose value. Hp(0.07) values to the hand (ranged 36.30–0.06 mSv) show that the index, middle and ring fingers are the most highly exposed. In this study, the wrist dose was negligible compared with the finger dose. These results are preliminary and further studies are needed to better characterise the dose assessment in CT fluoroscopy.
- 25 November 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 448-452
Preliminary assessment of the dose to the interventional radiologist in fluoro-CT-guided procedures
A preliminary assessment of the occupational dose to the intervention radiologist received in fluoroscopy computerised tomography (CT) used to guide the collection of lung and bone biopsies is presented. The main aim of this work was to evaluate the capability of the reading system as well as of the available whole-body (WB) and extremity dosemeters used in routine monthly monitoring periods to measure per procedure dose values. The intervention radiologist was allocated 10 WB detectors (LiF: Mg, Ti, TLD-100) placed at chest and abdomen levels above and below the lead apron, and at both right and left arms, knees and feet. A special glove was developed with casings for the insertion of 11 extremity detectors (LiF:Mg, Cu, P, TLD-100H) for the identification of the most highly exposed fingers. The Hp(10) dose values received above the lead apron (ranged 0.20–0.02 mSv) depend mainly on the duration of the examination and on the placement of physician relative to the beam, while values below the apron are relatively low. The left arm seems to receive a higher dose value. Hp(0.07) values to the hand (ranged 36.30–0.06 mSv) show that the index, middle and ring fingers are the most highly exposed. In this study, the wrist dose was negligible compared with the finger dose. These results are preliminary and further studies are needed to better characterise the dose assessment in CT fluoroscopy.
- 1 January 2009
- Published by Inderscience Publishers in International Journal of Low Radiation
- Vol. 6 (4) , 312
A Monte Carlo simulation of a whole body counter
The preparedness of response to the accidental incorporation of radionuclides into the human body by inhalation or ingestion is a subject of major concern due to the generalised use of ionising radiations in medical and industrial applications. Following a radiological or nuclear accident or in case of occupational exposure due to an accidental dispersion of radionuclides, a rapid methodology is necessary to evaluate the consequences of such events to professionals and members of the public. Efforts are currently under way at the Nuclear and Technological Institute (ITN, in Sacavem, near Lisbon) to set up and operate a Whole Body Counter (WBC) for the survey of the activity and the dose assessment in the case of radionuclide incorporation in the aforementioned accidental scenarios. The WBC of ITN includes a Hyperpure Germanium (HPGe) detector and a phantom, as well as a calibration source. To study and better understand the behaviour of the WBC detection system, Monte Carlo (MC) simulations have been performed using the state-of-the-art MC computer code MCNPX to create a computational set-up of the WBC. The simulation results were compared against experimental data and the corresponding results are reported in this work.
- 1 January 2009
- Published by Inderscience Publishers in International Journal of Low Radiation
- Vol. 6 (4) , 312
A Monte Carlo simulation of a whole body counter
The preparedness of response to the accidental incorporation of radionuclides into the human body by inhalation or ingestion is a subject of major concern due to the generalised use of ionising radiations in medical and industrial applications. Following a radiological or nuclear accident or in case of occupational exposure due to an accidental dispersion of radionuclides, a rapid methodology is necessary to evaluate the consequences of such events to professionals and members of the public. Efforts are currently under way at the Nuclear and Technological Institute (ITN, in Sacavem, near Lisbon) to set up and operate a Whole Body Counter (WBC) for the survey of the activity and the dose assessment in the case of radionuclide incorporation in the aforementioned accidental scenarios. The WBC of ITN includes a Hyperpure Germanium (HPGe) detector and a phantom, as well as a calibration source. To study and better understand the behaviour of the WBC detection system, Monte Carlo (MC) simulations have been performed using the state-of-the-art MC computer code MCNPX to create a computational set-up of the WBC. The simulation results were compared against experimental data and the corresponding results are reported in this work.
- 1 January 2009
- Published by Inderscience Publishers in International Journal of Low Radiation
- Vol. 6 (3) , 219
The definition of low doses and their importance in radiobiology
The aim of this work is to introduce a new dosimetric approach that is expected to contribute to characterising and distinguishing low, intermediate and high dose ranges. The emphasis will be on the low dose range, owing to the importance of the biological effects at low doses. A Monte Carlo code was used to simulate the energy degradation of photons in water, where the coherent and incoherent scattering were sampled from the Thompson and Klein-Nishina cross-sections corrected by the form factor and the incoherent scattering function, respectively. For the photoelectric effect, the kerma approximation was used, meaning that the simulation of the interactions of photons provides the initial spectra of the secondary electrons that cause damages at the cellular and intracellular levels. A new scoring method was proposed that allowed multiscale analysis of the energy deposited by radiation, inspired by the basic definition of an absorbed dose. Data for analysis were obtained from the simulation of a photon beam with extremely low dose values in a water phantom. Implications of the results in radiobiological studies are discussed.
- 1 January 2009
- Published by Inderscience Publishers in International Journal of Low Radiation
- Vol. 6 (3) , 219
The definition of low doses and their importance in radiobiology
The aim of this work is to introduce a new dosimetric approach that is expected to contribute to characterising and distinguishing low, intermediate and high dose ranges. The emphasis will be on the low dose range, owing to the importance of the biological effects at low doses. A Monte Carlo code was used to simulate the energy degradation of photons in water, where the coherent and incoherent scattering were sampled from the Thompson and Klein-Nishina cross-sections corrected by the form factor and the incoherent scattering function, respectively. For the photoelectric effect, the kerma approximation was used, meaning that the simulation of the interactions of photons provides the initial spectra of the secondary electrons that cause damages at the cellular and intracellular levels. A new scoring method was proposed that allowed multiscale analysis of the energy deposited by radiation, inspired by the basic definition of an absorbed dose. Data for analysis were obtained from the simulation of a photon beam with extremely low dose values in a water phantom. Implications of the results in radiobiological studies are discussed.
- 20 December 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 115 (1-4) , 600-605
Photon track evolution
Given the time scale of biological, biochemical, biophysical and physical effects in a radiation exposure of living tissue, the first physical stage can be considered to be independent of time. All the physical interactions caused by the incident photons happen at the same starting time. From this point of view it would seem that the evolution of photon tracks is not a relevant topic for analysis; however, if the photon track is considered as a sequence of several interactions, there are several steps until the total degradation of the energy of the primary photon. We can characterise the photon track structure by the probability p(E,j), that is, the probability that a photon with energy E suffers j secondary interactions. The aim of this work is to analyse the photon track structure by considering j as a step of the photon track evolution towards the total degradation of the photon energy. Low energy photons (<150 keV) are considered, with water phantoms and half-extended geometry. The photon track evolution concept is presented and compared with the energy deposition along the track and also with the spatial distribution of the several steps in the photon track.
- 20 December 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 115 (1-4) , 600-605
Photon track evolution
Given the time scale of biological, biochemical, biophysical and physical effects in a radiation exposure of living tissue, the first physical stage can be considered to be independent of time. All the physical interactions caused by the incident photons happen at the same starting time. From this point of view it would seem that the evolution of photon tracks is not a relevant topic for analysis; however, if the photon track is considered as a sequence of several interactions, there are several steps until the total degradation of the energy of the primary photon. We can characterise the photon track structure by the probability p(E,j), that is, the probability that a photon with energy E suffers j secondary interactions. The aim of this work is to analyse the photon track structure by considering j as a step of the photon track evolution towards the total degradation of the photon energy. Low energy photons (<150 keV) are considered, with water phantoms and half-extended geometry. The photon track evolution concept is presented and compared with the energy deposition along the track and also with the spatial distribution of the several steps in the photon track.
- 20 December 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 115 (1-4) , 254-257
Comparison of deterministic and Monte Carlo methods in shielding design
In shielding calculation, deterministic methods have some advantages and also some disadvantages relative to other kind of codes, such as Monte Carlo. The main advantage is the short computer time needed to find solutions while the disadvantages are related to the often-used build-up factor that is extrapolated from high to low energies or with unknown geometrical conditions, which can lead to significant errors in shielding results. The aim of this work is to investigate how good are some deterministic methods to calculating low-energy shielding, using attenuation coefficients and build-up factor corrections. Commercial software MicroShield 5.05 has been used as the deterministic code while MCNP has been used as the Monte Carlo code. Point and cylindrical sources with slab shield have been defined allowing comparison between the capability of both Monte Carlo and deterministic methods in a day-by-day shielding calculation using sensitivity analysis of significant parameters, such as energy and geometrical conditions.
- 20 December 2005
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 115 (1-4) , 254-257
Comparison of deterministic and Monte Carlo methods in shielding design
In shielding calculation, deterministic methods have some advantages and also some disadvantages relative to other kind of codes, such as Monte Carlo. The main advantage is the short computer time needed to find solutions while the disadvantages are related to the often-used build-up factor that is extrapolated from high to low energies or with unknown geometrical conditions, which can lead to significant errors in shielding results. The aim of this work is to investigate how good are some deterministic methods to calculating low-energy shielding, using attenuation coefficients and build-up factor corrections. Commercial software MicroShield 5.05 has been used as the deterministic code while MCNP has been used as the Monte Carlo code. Point and cylindrical sources with slab shield have been defined allowing comparison between the capability of both Monte Carlo and deterministic methods in a day-by-day shielding calculation using sensitivity analysis of significant parameters, such as energy and geometrical conditions.
- 1 November 2005
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 266 (3) , 377-384
Radionuclides used for therapy and suggestion for new candidates
- 1 November 2005
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 266 (3) , 377-384
Radionuclides used for therapy and suggestion for new candidates