Dylan O'COnnell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dylan O'COnnell has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jack Neylon
Department of Radiation Oncology University of California Los Angeles California USA
2 shared publications - John A. Charters
Department of Radiation Oncology, University of California, Los Angeles, Los Angeles, California
2 shared publications Jonathan Pham
Department of Radiation Oncology University of California, Los Angeles Los Angeles California USA
2 shared publications- Klea Hoxha
Department of Radiation Oncology University of California, Los Angeles Los Angeles California USA
2 shared publications Yasin Abdulkadir
Department of Radiation Oncology University of California Los Angeles California USA
2 shared publications- Andrew Krupien
Department of Radiation Oncology, David Geffen School of Medicine at UCLA University of California, Los Angeles Los Angeles California USA
1 shared publication
Latest Publications
- Open Access
- 31 March 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (4) , e70558
Automated identification of radiotherapy treatment sites from unstructured physician notes
Purpose: Ambiguous or incomplete documentation is a recurrent bottleneck in radiation oncology workflows, leading to inefficiencies in communication and potential treatment delays. Large language models (LLMs) pose a solution to addressing these ambiguities without added burden to clinical staff. We aim to assess the effectiveness of Meta's open‐source Llama 3.3 model in using physician consultation notes to isolate and classify anatomical treatment sites and create helpful extractive summaries for each patient. Methods: Semi‐structured interviews with five radiation therapists revealed that CT simulation orders lack the necessary details to acquire the appropriate image. A retrospective cohort of 100 patient notes was used for iterative prompt engineering. The final model was evaluated on an independent test cohort of 52 patient notes. The LLM's accuracy in identifying the treatment site was benchmarked against two human observers (a medical physicist and a physician) as well as the final delivered treatment plan (ground truth). The helpfulness and accuracy of the AI‐generated summaries were also rated by both observers on a 5‐point Likert scale. Results: Llama 3.3 achieved a weighted accuracy of 94.2% [95%CI: 89.4%–98.1%] when compared to sites isolated by either observer. When compared to the sites isolated from the retrospectively delivered plans, the model reached a weighted accuracy of 92.3% [95% CI: 87.5%–97.1%]. The model classified the anatomical sites with a weighted accuracy of 96.2% [95%CI: 87.0% –98.9%]. The AI‐generated summaries were highly rated by both observers (Observer 1: 4.96 [95%CI: 4.87–5.00] and Observer 2: 4.58 [95% CI: 4.38–4.73]). Conclusion: This pilot study provides foundational evidence that LLMs can classify data with high accuracy, achieve benchmarks comparable to human experts when isolating anatomical treatment sites, and produce clinically helpful summaries. Our results suggest that LLMs can be effectively integrated to streamline complex radiotherapy workflows in the clinic.
- 31 March 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (4) , e70558
Open AccessAutomated identification of radiotherapy treatment sites from unstructured physician notes
Purpose: Ambiguous or incomplete documentation is a recurrent bottleneck in radiation oncology workflows, leading to inefficiencies in communication and potential treatment delays. Large language models (LLMs) pose a solution to addressing these ambiguities without added burden to clinical staff. We aim to assess the effectiveness of Meta's open‐source Llama 3.3 model in using physician consultation notes to isolate and classify anatomical treatment sites and create helpful extractive summaries for each patient. Methods: Semi‐structured interviews with five radiation therapists revealed that CT simulation orders lack the necessary details to acquire the appropriate image. A retrospective cohort of 100 patient notes was used for iterative prompt engineering. The final model was evaluated on an independent test cohort of 52 patient notes. The LLM's accuracy in identifying the treatment site was benchmarked against two human observers (a medical physicist and a physician) as well as the final delivered treatment plan (ground truth). The helpfulness and accuracy of the AI‐generated summaries were also rated by both observers on a 5‐point Likert scale. Results: Llama 3.3 achieved a weighted accuracy of 94.2% [95%CI: 89.4%–98.1%] when compared to sites isolated by either observer. When compared to the sites isolated from the retrospectively delivered plans, the model reached a weighted accuracy of 92.3% [95% CI: 87.5%–97.1%]. The model classified the anatomical sites with a weighted accuracy of 96.2% [95%CI: 87.0% –98.9%]. The AI‐generated summaries were highly rated by both observers (Observer 1: 4.96 [95%CI: 4.87–5.00] and Observer 2: 4.58 [95% CI: 4.38–4.73]). Conclusion: This pilot study provides foundational evidence that LLMs can classify data with high accuracy, achieve benchmarks comparable to human experts when isolating anatomical treatment sites, and produce clinically helpful summaries. Our results suggest that LLMs can be effectively integrated to streamline complex radiotherapy workflows in the clinic.
- Open Access
- 5 April 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (6) , e70089
Open‐source deep‐learning models for segmentation of normal structures for prostatic and gynecological high‐dose‐rate brachytherapy: Comparison of architectures
Background: The use of deep learning‐based auto‐contouring algorithms in various treatment planning services is increasingly common. There is a notable deficit of commercially or publicly available models trained on large or diverse datasets containing high‐dose‐rate (HDR) brachytherapy treatment scans, leading to poor performance on images that include HDR implants.Purpose: To implement and evaluate automatic organs‐at‐risk (OARs) segmentation models for use in prostatic‐and‐gynecological computed tomography (CT)‐guided high‐dose‐rate brachytherapy treatment planning.Methods and materials: 1316 computed tomography (CT) scans and corresponding segmentation files from 1105 prostatic‐or‐gynecological HDR patients treated at our institution from 2017 to 2024 were used for model training. Data sources comprised six CT scanners including a mobile CT unit with previously reported susceptibility to image streaking artifacts. Two UNet‐derived model architectures, UNet++ and nnU‐Net, were investigated for bladder and rectum model training. The models were tested on 100 CT scans and clinically‐used segmentation files from 62 prostatic‐or‐gynecological HDR brachytherapy patients, disjoint from the training set, collected in 2024. Performance was evaluated using the Dice‐Similarity‐Coefficient (DSC) between model predicted contours and clinically‐used contours on slices in common with the Clinical‐Target‐Volume (CTV). Additionally, a blinded evaluation of ten random test cases was conducted by three experienced planners.Results: Median (interquartile range) 3D DSC on CTV‐containing slices were 0.95 (0.04) and 0.87 (0.09) for the UNet++ bladder and rectum models, respectively, and 0.96 (0.03) and 0.88 (0.10) for the nnU‐Net. The rank‐sum test did not reveal statistically significant differences in these DSC (p = 0.15 and 0.27, respectively). The blinded evaluation scored trained models higher than clinically‐used contours.Conclusion: Both UNet‐derived architectures perform similarly on the bladder and rectum and are adequately accurate to reduce contouring time in a review‐and‐edit context during HDR brachytherapy planning. The UNet++ models were chosen for implementation at our institution due to lower computing hardware requirements and are in routine clinical use.
- 5 April 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (6) , e70089
Open AccessOpen‐source deep‐learning models for segmentation of normal structures for prostatic and gynecological high‐dose‐rate brachytherapy: Comparison of architectures
Background: The use of deep learning‐based auto‐contouring algorithms in various treatment planning services is increasingly common. There is a notable deficit of commercially or publicly available models trained on large or diverse datasets containing high‐dose‐rate (HDR) brachytherapy treatment scans, leading to poor performance on images that include HDR implants.Purpose: To implement and evaluate automatic organs‐at‐risk (OARs) segmentation models for use in prostatic‐and‐gynecological computed tomography (CT)‐guided high‐dose‐rate brachytherapy treatment planning.Methods and materials: 1316 computed tomography (CT) scans and corresponding segmentation files from 1105 prostatic‐or‐gynecological HDR patients treated at our institution from 2017 to 2024 were used for model training. Data sources comprised six CT scanners including a mobile CT unit with previously reported susceptibility to image streaking artifacts. Two UNet‐derived model architectures, UNet++ and nnU‐Net, were investigated for bladder and rectum model training. The models were tested on 100 CT scans and clinically‐used segmentation files from 62 prostatic‐or‐gynecological HDR brachytherapy patients, disjoint from the training set, collected in 2024. Performance was evaluated using the Dice‐Similarity‐Coefficient (DSC) between model predicted contours and clinically‐used contours on slices in common with the Clinical‐Target‐Volume (CTV). Additionally, a blinded evaluation of ten random test cases was conducted by three experienced planners.Results: Median (interquartile range) 3D DSC on CTV‐containing slices were 0.95 (0.04) and 0.87 (0.09) for the UNet++ bladder and rectum models, respectively, and 0.96 (0.03) and 0.88 (0.10) for the nnU‐Net. The rank‐sum test did not reveal statistically significant differences in these DSC (p = 0.15 and 0.27, respectively). The blinded evaluation scored trained models higher than clinically‐used contours.Conclusion: Both UNet‐derived architectures perform similarly on the bladder and rectum and are adequately accurate to reduce contouring time in a review‐and‐edit context during HDR brachytherapy planning. The UNet++ models were chosen for implementation at our institution due to lower computing hardware requirements and are in routine clinical use.
- Open Access
- 9 February 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (5) , e14295
An IMRT planning technique for treating whole breast or chest wall with regional lymph nodes on Halcyon and Ethos
Purpose/Objective: Field size limitations on Halcyon and Ethos treatment machines largely preclude use of the conventional monoisocentric three‐field technique for breast/chest wall and regional lymph nodes. We present an alternative, IMRT‐based planning approach that facilitates treatment on Halcyon and Ethos while preserving plan quality.Materials/Methods: Eight breast and regional node cases (four left‐sided, four right‐sided) were planned for an Ethos machine using a 15–17 field IMRT technique. Institutional plan quality metrics for CTV and PTV coverage and OAR sparing were assessed. Five plans (four right‐sided, one left‐sided) were also planned using a hybrid 3D multisocenter technique. CTV coverage and OAR sparing were compared to the IMRT plans. Eclipse scripting tools were developed to aid in beam placement and plan evaluation through a set of dosimetric scorecards, and both are shared publicly.Results: On average, the IMRT plans achieved breast CTV and PTV coverage at 50 Gy of 97.9% and 95.7%, respectively. Supraclavicular CTV and PTV coverages at 45 Gy were 100% and 95.5%. Axillary lymph node CTV and PTV coverages at 45 Gy were 100% and 97.1%, and IMN CTV coverage at 45 Gy was 99.2%. Mean ipsilateral lung V20 Gy was 19.3%, and average mean heart dose was 1.6 Gy for right‐sided cases and 3.0 Gy for left‐sided. In comparison to the hybrid 3D plans, IMRT plans achieved higher breast and supraclavicular CTV coverage (99.9% vs. 98.6% and 99.9% vs. 93.4%), higher IMN coverage (99.6% vs. 78.2%), and lower ipsilateral lung V20 Gy (19.6% vs. 28.2%).Conclusion: Institutional plan quality benchmarks were achieved for all eight cases using the IMRT‐based planning approach. The IMRT‐based planning approach offered superior conformity and OAR sparing than a competing hybrid 3D approach.
- 9 February 2024
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (5) , e14295
Open AccessAn IMRT planning technique for treating whole breast or chest wall with regional lymph nodes on Halcyon and Ethos
Purpose/Objective: Field size limitations on Halcyon and Ethos treatment machines largely preclude use of the conventional monoisocentric three‐field technique for breast/chest wall and regional lymph nodes. We present an alternative, IMRT‐based planning approach that facilitates treatment on Halcyon and Ethos while preserving plan quality.Materials/Methods: Eight breast and regional node cases (four left‐sided, four right‐sided) were planned for an Ethos machine using a 15–17 field IMRT technique. Institutional plan quality metrics for CTV and PTV coverage and OAR sparing were assessed. Five plans (four right‐sided, one left‐sided) were also planned using a hybrid 3D multisocenter technique. CTV coverage and OAR sparing were compared to the IMRT plans. Eclipse scripting tools were developed to aid in beam placement and plan evaluation through a set of dosimetric scorecards, and both are shared publicly.Results: On average, the IMRT plans achieved breast CTV and PTV coverage at 50 Gy of 97.9% and 95.7%, respectively. Supraclavicular CTV and PTV coverages at 45 Gy were 100% and 95.5%. Axillary lymph node CTV and PTV coverages at 45 Gy were 100% and 97.1%, and IMN CTV coverage at 45 Gy was 99.2%. Mean ipsilateral lung V20 Gy was 19.3%, and average mean heart dose was 1.6 Gy for right‐sided cases and 3.0 Gy for left‐sided. In comparison to the hybrid 3D plans, IMRT plans achieved higher breast and supraclavicular CTV coverage (99.9% vs. 98.6% and 99.9% vs. 93.4%), higher IMN coverage (99.6% vs. 78.2%), and lower ipsilateral lung V20 Gy (19.6% vs. 28.2%).Conclusion: Institutional plan quality benchmarks were achieved for all eight cases using the IMRT‐based planning approach. The IMRT‐based planning approach offered superior conformity and OAR sparing than a competing hybrid 3D approach.
- Open Access
- 10 August 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (9)
Dosimetric evaluation of respiratory gating on a 0.35‐T magnetic resonance–guided radiotherapy linac
Purpose: The commercial 0.35‐T magnetic resonance imaging (MRI)‐guided radiotherapy vendor ViewRay recently introduced upgraded real‐time imaging frame rates based on compressed sensing techniques. Furthermore, additional motion tracking algorithms were made available. Compressed sensing allows for increased image frame rates but may compromise image quality. To assess the impact of this upgrade on respiratory gating accuracy, we evaluated gated dose distributions pre‐ and post‐upgrade using a motion phantom and radiochromic film.Methods: Seven motion waveforms (four artificial, two patient‐derived free‐breathing, and one breath‐holding) were used to drive an MRI‐compatible motion phantom. A treatment plan was developed to deliver a 3‐cm diameter spherical dose distribution typical of a stereotactic body radiotherapy plan. Gating was performed using 4‐frames per second (fps) imaging pre‐upgrade on the “default” tracking algorithm and 8‐fps post‐upgrade using the “small mobile targets” (SMT) and “large deforming targets” (LDT) tracking algorithms. Radiochromic film was placed in a moving insert within the phantom to measure dose. The planned and delivered dose distributions were compared using the gamma index with 3%/3‐mm criteria. Dose–area histograms were produced to calculate the dose to 95% (D95) of the sphere planning target volume (PTV) and two simulated gross tumor volumes formed by contracting the PTV by 3 and 5 mm, respectively.Results: Gamma pass rates ranged from 18% to 93% over the 21 combinations of breathing trace and gating conditions examined. D95 ranged from 206 to 514 cGy. On average, the LDT algorithm yielded lower gamma and D95 values than the default and SMT algorithms.Conclusion: Respiratory gating at 8 fps with the new tracking algorithms provides similar gating performance to the original algorithm with 4 fps, although the LDT algorithm had lower accuracy for our non‐deformable target. This indicates that the choice of deformable image registration algorithm should be chosen deliberately based on whether the target is rigid or deforming.
- 10 August 2022
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 23 (9)
Open AccessDosimetric evaluation of respiratory gating on a 0.35‐T magnetic resonance–guided radiotherapy linac
Purpose: The commercial 0.35‐T magnetic resonance imaging (MRI)‐guided radiotherapy vendor ViewRay recently introduced upgraded real‐time imaging frame rates based on compressed sensing techniques. Furthermore, additional motion tracking algorithms were made available. Compressed sensing allows for increased image frame rates but may compromise image quality. To assess the impact of this upgrade on respiratory gating accuracy, we evaluated gated dose distributions pre‐ and post‐upgrade using a motion phantom and radiochromic film.Methods: Seven motion waveforms (four artificial, two patient‐derived free‐breathing, and one breath‐holding) were used to drive an MRI‐compatible motion phantom. A treatment plan was developed to deliver a 3‐cm diameter spherical dose distribution typical of a stereotactic body radiotherapy plan. Gating was performed using 4‐frames per second (fps) imaging pre‐upgrade on the “default” tracking algorithm and 8‐fps post‐upgrade using the “small mobile targets” (SMT) and “large deforming targets” (LDT) tracking algorithms. Radiochromic film was placed in a moving insert within the phantom to measure dose. The planned and delivered dose distributions were compared using the gamma index with 3%/3‐mm criteria. Dose–area histograms were produced to calculate the dose to 95% (D95) of the sphere planning target volume (PTV) and two simulated gross tumor volumes formed by contracting the PTV by 3 and 5 mm, respectively.Results: Gamma pass rates ranged from 18% to 93% over the 21 combinations of breathing trace and gating conditions examined. D95 ranged from 206 to 514 cGy. On average, the LDT algorithm yielded lower gamma and D95 values than the default and SMT algorithms.Conclusion: Respiratory gating at 8 fps with the new tracking algorithms provides similar gating performance to the original algorithm with 4 fps, although the LDT algorithm had lower accuracy for our non‐deformable target. This indicates that the choice of deformable image registration algorithm should be chosen deliberately based on whether the target is rigid or deforming.
- 26 April 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095013
McSART: an iterative model-based, motion-compensated SART algorithm for CBCT reconstruction
4D cone beam computed tomography (CBCT) images of the thorax and abdomen can have reduced quality due to the limited number of projections per respiratory bin used in gated image reconstruction. In this work, we present a new algorithm to reconstruct high quality CBCT images by simultaneously reconstructing images and generating an associated respiratory motion model. This is done by updating model parameters to compensate for motion during the iterative image reconstruction process. CBCT image acquisition was simulated using the digital eXternal CArdiac Torso (XCAT) phantom, simulating breathing motion using four patient breathing traces. 4DCBCT images were reconstructed using the simultaneous algebraic reconstruction technique (SART), and compared to the proposed motion-compensated SART (McSART) algorithm. McSART used a motion model that describes tissue position as a function of diaphragm amplitude and velocity. The McSART algorithm alternately updated the motion model and image reconstruction, increasing the number of projections used for image reconstruction with every iteration. The model was able to interpolate and extrapolate deformations according to the magnitude of the surrogate signal. Without noise, the final iteration McSART images had HU errors at 31%, 34%, and 44% of their SART-reconstructed counterparts compared to ground truth XCAT images, with corresponding root-mean-square (RMS) motion model errors of 0.75 mm, 1.08 mm, and 1.17 mm respectively. With added image noise, McSART’s HU error was 31% of the SART-reconstructed 4DCBCT error, with a 1.43 mm RMS motion model error. Qualitatively, blurring and streaking artifacts were reduced in all the reconstructed images compared to 3D or SART-reconstructed 4DCBCT. The output of the algorithm was a high quality reference image and a corresponding motion model, that could be used to deform the reference image to any other point in a breathing cycle.
- 26 April 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (9) , 095013
McSART: an iterative model-based, motion-compensated SART algorithm for CBCT reconstruction
4D cone beam computed tomography (CBCT) images of the thorax and abdomen can have reduced quality due to the limited number of projections per respiratory bin used in gated image reconstruction. In this work, we present a new algorithm to reconstruct high quality CBCT images by simultaneously reconstructing images and generating an associated respiratory motion model. This is done by updating model parameters to compensate for motion during the iterative image reconstruction process. CBCT image acquisition was simulated using the digital eXternal CArdiac Torso (XCAT) phantom, simulating breathing motion using four patient breathing traces. 4DCBCT images were reconstructed using the simultaneous algebraic reconstruction technique (SART), and compared to the proposed motion-compensated SART (McSART) algorithm. McSART used a motion model that describes tissue position as a function of diaphragm amplitude and velocity. The McSART algorithm alternately updated the motion model and image reconstruction, increasing the number of projections used for image reconstruction with every iteration. The model was able to interpolate and extrapolate deformations according to the magnitude of the surrogate signal. Without noise, the final iteration McSART images had HU errors at 31%, 34%, and 44% of their SART-reconstructed counterparts compared to ground truth XCAT images, with corresponding root-mean-square (RMS) motion model errors of 0.75 mm, 1.08 mm, and 1.17 mm respectively. With added image noise, McSART’s HU error was 31% of the SART-reconstructed 4DCBCT error, with a 1.43 mm RMS motion model error. Qualitatively, blurring and streaking artifacts were reduced in all the reconstructed images compared to 3D or SART-reconstructed 4DCBCT. The output of the algorithm was a high quality reference image and a corresponding motion model, that could be used to deform the reference image to any other point in a breathing cycle.