JNJack Neylon

Jack Neylon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jack Neylon has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    RTHistory: An automated tool for the extraction and presentation of radiotherapy course history for continuity of care applications

    by Justin B. Hink, Yasin Abdulkadir, Andrew Krupien, Peter Boyle, Daniel A. Low, Jack Neylon, James Lamb

    Background: Transfer of radiation treatment records is a common task for radiotherapy clinics, as treatment history impacts future treatment planning, including prescription dose, fractionation, and normal tissue constraint selections. Currently, gathering radiation records relies on manual searches within treatment planning databases and Record and Verify (R&V) systems, a process that is time‐consuming and subject to human error. Particularly challenging is discerning which plans were treated, and for how many fractions, in cases of treatment adaptation or early termination. Purpose: In this technical note, we present RTHistory , an open‐source software tool that automates the extraction process for R&V systems that implement DICOM Query/Retrieve and summarizes the treatment history in a format optimized for efficient clinical readability and visual triage. Methods: RTHistory was configured to query multiple clinical systems through the DICOM protocol. The query process begins with downloading and analyzing the RTRecords, which document beam delivery. From these, internal DICOM object references are followed to gather the relevant planning files, including dose, simulation scan, and structure set. RTHistory then parses these DICOM files to create a treatment summary PDF report that describes the plan labels, prescription doses, treatment start and end dates, number of fractions treated, and a graphical representation of the dose washes of the treated plans. Rigorous software unit testing and error handling procedures were implemented to ensure reliability and accuracy of the extracted data. Results: RTHistory was evaluated on a clinical cohort of 61 patients comprising 177 distinct treatment plans across six anatomical sites from our institutional database, which included the ARIA/Eclipse R&V system and treatment planning system. Manual verification against clinical ARIA and Eclipse records confirmed 100% agreement in reconstructing delivered DICOM‐RT objects (177/177 plans), with none of 439 undelivered plans included (specificity: 100%; 95% CI: 99.2%–100%). Performance testing for patients with at least one treatment planned in Eclipse ( n = 51 patients) yielded a median overall patient run time of 115.4 s (aggregate per‐plan: 59.5 s, 95% bootstrap confidence interval: 45.6–72.1 s), which scaled directly with the number of CT series (93.4 20.0 s per series). In a direct comparison across 42 patients, manual abstraction required a mean active hands‐on time of 342.0 378.0 s (median: 192.0 s, range: 90.0–2214.0 s), whereas the software ran unattended with a mean execution time of 228.0 282.0 s (median: 114.0 s, range: 48.0–1318.6 s). Conclusion: RTHistory offers a solution to improve continuity of care by facilitating accurate information sharing through the automated extraction and presentation of treatment history. Looking ahead, integration into institutional workflows holds promise for enhancing patient care and decision‐making in oncological treatment, while reducing the manual burden on clinical staff and mitigating transcription risks in re‐irradiation workflows.

  • Open Access

    Automated identification of radiotherapy treatment sites from unstructured physician notes

    by Klea Hoxha, Ricky R. Savjani, Jack Neylon, Jonathan Pham, Rojine Ariani, Dylan P. O'COnnell

    Purpose: Ambiguous or incomplete documentation is a recurrent bottleneck in radiation oncology workflows, leading to inefficiencies in communication and potential treatment delays. Large language models (LLMs) pose a solution to addressing these ambiguities without added burden to clinical staff. We aim to assess the effectiveness of Meta's open‐source Llama 3.3 model in using physician consultation notes to isolate and classify anatomical treatment sites and create helpful extractive summaries for each patient. Methods: Semi‐structured interviews with five radiation therapists revealed that CT simulation orders lack the necessary details to acquire the appropriate image. A retrospective cohort of 100 patient notes was used for iterative prompt engineering. The final model was evaluated on an independent test cohort of 52 patient notes. The LLM's accuracy in identifying the treatment site was benchmarked against two human observers (a medical physicist and a physician) as well as the final delivered treatment plan (ground truth). The helpfulness and accuracy of the AI‐generated summaries were also rated by both observers on a 5‐point Likert scale. Results: Llama 3.3 achieved a weighted accuracy of 94.2% [95%CI: 89.4%–98.1%] when compared to sites isolated by either observer. When compared to the sites isolated from the retrospectively delivered plans, the model reached a weighted accuracy of 92.3% [95% CI: 87.5%–97.1%]. The model classified the anatomical sites with a weighted accuracy of 96.2% [95%CI: 87.0% –98.9%]. The AI‐generated summaries were highly rated by both observers (Observer 1: 4.96 [95%CI: 4.87–5.00] and Observer 2: 4.58 [95% CI: 4.38–4.73]). Conclusion: This pilot study provides foundational evidence that LLMs can classify data with high accuracy, achieve benchmarks comparable to human experts when isolating anatomical treatment sites, and produce clinically helpful summaries. Our results suggest that LLMs can be effectively integrated to streamline complex radiotherapy workflows in the clinic.

  • Open Access

    Open‐source deep‐learning models for segmentation of normal structures for prostatic and gynecological high‐dose‐rate brachytherapy: Comparison of architectures

    by Andrew J. Krupien, Yasin Abdulkadir, Dishane C. Luximon, John Charters, Huiming Dong, Jonathan Pham, Dylan O'COnnell, Jack Neylon, James M. Lamb

    Background: The use of deep learning‐based auto‐contouring algorithms in various treatment planning services is increasingly common. There is a notable deficit of commercially or publicly available models trained on large or diverse datasets containing high‐dose‐rate (HDR) brachytherapy treatment scans, leading to poor performance on images that include HDR implants.Purpose: To implement and evaluate automatic organs‐at‐risk (OARs) segmentation models for use in prostatic‐and‐gynecological computed tomography (CT)‐guided high‐dose‐rate brachytherapy treatment planning.Methods and materials: 1316 computed tomography (CT) scans and corresponding segmentation files from 1105 prostatic‐or‐gynecological HDR patients treated at our institution from 2017 to 2024 were used for model training. Data sources comprised six CT scanners including a mobile CT unit with previously reported susceptibility to image streaking artifacts. Two UNet‐derived model architectures, UNet++ and nnU‐Net, were investigated for bladder and rectum model training. The models were tested on 100 CT scans and clinically‐used segmentation files from 62 prostatic‐or‐gynecological HDR brachytherapy patients, disjoint from the training set, collected in 2024. Performance was evaluated using the Dice‐Similarity‐Coefficient (DSC) between model predicted contours and clinically‐used contours on slices in common with the Clinical‐Target‐Volume (CTV). Additionally, a blinded evaluation of ten random test cases was conducted by three experienced planners.Results: Median (interquartile range) 3D DSC on CTV‐containing slices were 0.95 (0.04) and 0.87 (0.09) for the UNet++ bladder and rectum models, respectively, and 0.96 (0.03) and 0.88 (0.10) for the nnU‐Net. The rank‐sum test did not reveal statistically significant differences in these DSC (p = 0.15 and 0.27, respectively). The blinded evaluation scored trained models higher than clinically‐used contours.Conclusion: Both UNet‐derived architectures perform similarly on the bladder and rectum and are adequately accurate to reduce contouring time in a review‐and‐edit context during HDR brachytherapy planning. The UNet++ models were chosen for implementation at our institution due to lower computing hardware requirements and are in routine clinical use.


  • Open Access

    Clinical physicists’ perceptions of weekly chart checks and the potential role for automated image review assessed by structured interviews

    by Rachel Petragallo, Dishane C. Luximon, Jack Neylon, Naomi S. Bardach, Timothy Ritter, James M. Lamb

    Background: This study utilizes interviews of clinical medical physicists to investigate self‐reported shortcomings of the current weekly chart check workflow and opportunities for improvement.Methods: Nineteen medical physicists were recruited for a 30‐minute semi‐structured interview, with a particular focus placed on image review and the use of automated tools for image review in weekly checks. Survey‐type questions were used to gather quantitative information about chart check practices and importance placed on reducing chart check workloads versus increasing chart check effectiveness. Open‐ended questions were used to probe respondents about their current weekly chart check workflow, opinions of the value of weekly chart checks and perceived shortcomings, and barriers and facilitators to the implementation of automated chart check tools. Thematic analysis was used to develop common themes across the interviews.Results: Physicists ranked highly the value of reducing the time spent on weekly chart checks (average 6.3 on a scale from 1 to 10), but placed more value on increasing the effectiveness of checks with an average of 9.2 on a 1–10 scale. Four major themes were identified: (1) weekly chart checks need to adapt to an electronic record‐and‐verify chart environment, (2) physicists could add value to patient care by analyzing images without duplicating the work done by physicians, (3) greater support for trending analysis is needed in weekly checks, and (4) automation has the potential to increase the value of physics checks.Conclusion: This study identified several key shortcomings of the current weekly chart check process from the perspective of the clinical medical physicist. Our results show strong support for automating components of the weekly check workflow in order to allow for more effective checks that emphasize follow‐up, trending, failure modes and effects analysis, and allow time to be spent on other higher value tasks that improve patient safety.


  • Open Access

    Automated detection of vertebral body misalignments in orthogonal kV and MV guided radiotherapy: application to a comprehensive retrospective dataset

    by John A Charters, Dishane Luximon, Rachel Petragallo, Jack Neylon, Daniel A Low, James M Lamb

    Objective. In image-guided radiotherapy (IGRT), off-by-one vertebral body misalignments are rare but potentially catastrophic. In this study, a novel detection method for such misalignments in IGRT was investigated using densely-connected convolutional networks (DenseNets) for applications towards real-time error prevention and retrospective error auditing. Approach. A total of 4213 images acquired from 527 radiotherapy patients aligned with planar kV or MV radiographs were used to develop and test error-detection software modules. Digitally reconstructed radiographs (DRRs) and setup images were retrieved and co-registered according to the clinically applied alignment contained in the DICOM REG files. A semi-automated algorithm was developed to simulate patient positioning errors on the anterior-posterior (AP) and lateral (LAT) images shifted by one vertebral body. A DenseNet architecture was designed to classify either AP images individually or AP and LAT image pairs. Receiver-operator characteristic curves (ROC) and areas under the curves (AUC) were computed to evaluate the classifiers on test subsets. Subsequently, the algorithm was applied to the entire dataset in order to retrospectively determine the absolute off-by-one vertebral body error rate for planar radiograph guided RT at our institution from 2011–2021. Main results. The AUCs for the kV models were 0.98 for unpaired AP and 0.99 for paired AP-LAT. The AUC for the MV AP model was 0.92. For a specificity of 95%, the paired kV model achieved a sensitivity of 99%. Application of the model to the entire dataset yielded a per-fraction off-by-one vertebral body error rate of 0.044% [0.0022%, 0.21%] for paired kV IGRT including one previously unreported error. Significance. Our error detection algorithm was successful in classifying vertebral body positioning errors with sufficient accuracy for retrospective quality control and real-time error prevention. The reported positioning error rate for planar radiograph IGRT is unique in being determined independently of an error reporting system.