Martin H. L. Chow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martin H. L. Chow has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
C.K. Tse
16 shared publicationsYim-Shu Lee
7 shared publicationsChi K. Tse
Department of Electronic and Information Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong
6 shared publicationsMartin K. H. Cheung
Department of Electronic and Information Engineering, The Hong Kong Polytechnic University , Kowloon, Hong Kong
5 shared publicationsY.S. Lee
Department of Electronic Engineering, Hong Kong Polytechnic University, Hong Kong, China
4 shared publications- Yuk Ming Lai
Department of Electronic and Information Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong
4 shared publications
Latest Publications
- 18 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 31 (3) , 2465-2475
An Alternative Approach to LED Driver Design Based on High-Voltage Driving
This paper discusses an alternative approach to designing LED drivers based on high-voltage operation. Compared with the conventional approach of driving LEDs with low voltage and high current, the alternative approach aims to deliver the same power to LED load with high voltage and low current so that small and nonelectrolytic capacitor can be used. High-voltage operation also facilitates the use of simple PFC preregulators such as boost or SEPIC converters as single-stage LED drivers. This paper begins with the derivation of the relationship between the nominal output voltage and output capacitor's size of a PFC preregulator for achieving a given output voltage ripple's size, followed by a review of the recently emerged high-voltage LED packages suitable for the proposed application. This paper also discusses the flicker and colorimetric performances of LED light sources under the influence of large current ripple when nonelectrolytic capacitor is used. The method of third-harmonic current injection to the input current of LED drivers is also incorporated as an option for further reducing the output capacitor's size while meeting a specified flicker limit. Finally, a design example of high-voltage LED driver based on a boost PFC preregulator with third-harmonic current injection is presented and verified experimentally.
- 18 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 31 (3) , 2465-2475
An Alternative Approach to LED Driver Design Based on High-Voltage Driving
This paper discusses an alternative approach to designing LED drivers based on high-voltage operation. Compared with the conventional approach of driving LEDs with low voltage and high current, the alternative approach aims to deliver the same power to LED load with high voltage and low current so that small and nonelectrolytic capacitor can be used. High-voltage operation also facilitates the use of simple PFC preregulators such as boost or SEPIC converters as single-stage LED drivers. This paper begins with the derivation of the relationship between the nominal output voltage and output capacitor's size of a PFC preregulator for achieving a given output voltage ripple's size, followed by a review of the recently emerged high-voltage LED packages suitable for the proposed application. This paper also discusses the flicker and colorimetric performances of LED light sources under the influence of large current ripple when nonelectrolytic capacitor is used. The method of third-harmonic current injection to the input current of LED drivers is also incorporated as an option for further reducing the output capacitor's size while meeting a specified flicker limit. Finally, a design example of high-voltage LED driver based on a boost PFC preregulator with third-harmonic current injection is presented and verified experimentally.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 6058-6062
Elimination of electrolytic capacitor through high-voltage driving of LED aided by third-order harmonic current injection
In this paper, the concept of high-voltage driving of LED is proposed to reduce the output voltage ripple of LED driver circuits by decreasing the AC current flowing through the output capacitor, leading to the potential replacement of electrolytic capacitor with other capacitor types having significantly longer lifetime. It also enables a direct driving of the LED load without the need for a second stage for voltage step-down. To further reduce the output voltage ripple's amplitude or output capacitor's size, the well-known third-order harmonic current injection technique can be incorporated. A general design procedure including the effect of harmonic current injection is proposed and verified experimentally.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 6058-6062
Elimination of electrolytic capacitor through high-voltage driving of LED aided by third-order harmonic current injection
In this paper, the concept of high-voltage driving of LED is proposed to reduce the output voltage ripple of LED driver circuits by decreasing the AC current flowing through the output capacitor, leading to the potential replacement of electrolytic capacitor with other capacitor types having significantly longer lifetime. It also enables a direct driving of the LED load without the need for a second stage for voltage step-down. To further reduce the output voltage ripple's amplitude or output capacitor's size, the well-known third-order harmonic current injection technique can be incorporated. A general design procedure including the effect of harmonic current injection is proposed and verified experimentally.
- 20 September 2012
- Published by The Korean Institute of Power Electronics in Journal of Power Electronics
- Vol. 12 (5) , 689-698
Effects of Imperfect Sinusoidal Input Currents on the Performance of a Boost PFC Pre-Regulator
- 20 September 2012
- Published by The Korean Institute of Power Electronics in Journal of Power Electronics
- Vol. 12 (5) , 689-698
Effects of Imperfect Sinusoidal Input Currents on the Performance of a Boost PFC Pre-Regulator
- 2 May 2012
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 5 (5) , 591-599
Design of a 1-kVA parallel-type AC voltage sag compensator
In this study, some issues of voltage sags in the AC mains are discussed. The characteristics of voltage sags and the SEMI F47 requirements are outlined. Existing solutions to solve the voltage sag problems are compared. The design methodologies of AC voltage sag compensators are introduced. The detailed design and the flow chart of the control programme of a new parallel-type AC voltage sag compensator are described. The main advantage of the parallel-type compensator is that it can disconnect the load from the AC mains to eliminate the effects of interruptions or faults that occur in the AC mains during the compensation period. A practical 1-kVA parallel-type voltage sag compensator has been designed and constructed for evaluation. Measurements have been carried out to verify the performance of the compensator under different voltage sag conditions.
- 2 May 2012
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 5 (5) , 591-599
Design of a 1-kVA parallel-type AC voltage sag compensator
In this study, some issues of voltage sags in the AC mains are discussed. The characteristics of voltage sags and the SEMI F47 requirements are outlined. Existing solutions to solve the voltage sag problems are compared. The design methodologies of AC voltage sag compensators are introduced. The detailed design and the flow chart of the control programme of a new parallel-type AC voltage sag compensator are described. The main advantage of the parallel-type compensator is that it can disconnect the load from the AC mains to eliminate the effects of interruptions or faults that occur in the AC mains during the compensation period. A practical 1-kVA parallel-type voltage sag compensator has been designed and constructed for evaluation. Measurements have been carried out to verify the performance of the compensator under different voltage sag conditions.
- 8 February 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 57 (11) , 3730-3745
Design and Performance Considerations of PFC Switching Regulators Based on Noncascading Structures
This paper systematically explores the performances of power-factor-correction (PFC) switching regulators based on noncascading structures in terms of efficiency, input-current harmonic distortion, and load voltage regulation. The investigation begins with simplified power-flow diagrams, which represent the noncascading PFC switching regulators and describe the essential features of the noncascading PFC switching regulators to achieve PFC and voltage regulation. Based on these diagrams, the noncascading PFC switching regulators can be classified into three categories, each offering a different set of performances. The first category permits a tradeoff between the efficiency and the input-current harmonic distortion, the second permits a tradeoff between the efficiency and the size of the storage element for the load voltage regulation, and the third allows a tradeoff among all the performances. With detailed analyses through analytical approaches, simulation results illustrate the performances of these three categories of noncascading PFC switching regulators. An experimental prototype of the third category has been built to validate the analyses.
- 8 February 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 57 (11) , 3730-3745
Design and Performance Considerations of PFC Switching Regulators Based on Noncascading Structures
This paper systematically explores the performances of power-factor-correction (PFC) switching regulators based on noncascading structures in terms of efficiency, input-current harmonic distortion, and load voltage regulation. The investigation begins with simplified power-flow diagrams, which represent the noncascading PFC switching regulators and describe the essential features of the noncascading PFC switching regulators to achieve PFC and voltage regulation. Based on these diagrams, the noncascading PFC switching regulators can be classified into three categories, each offering a different set of performances. The first category permits a tradeoff between the efficiency and the input-current harmonic distortion, the second permits a tradeoff between the efficiency and the size of the storage element for the load voltage regulation, and the third allows a tradeoff among all the performances. With detailed analyses through analytical approaches, simulation results illustrate the performances of these three categories of noncascading PFC switching regulators. An experimental prototype of the third category has been built to validate the analyses.
- 1 May 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2587-2590
Design of AC voltage sag compensators
AC operated electronic equipment are vulnerable to momentary losses of AC voltage, which are known as voltage sags. Voltage sags are commonly caused by lightning, accidental short circuit, loose connection, starting of large motors (or air-conditioners) or abnormal use of the AC mains. In sensitive and critical applications, such as semiconductor material processing and medical operation, voltage sags may result in serious problems. In order to tackle this problem, the Semiconductor Equipment and Materials International (SEMI) defined, in 1996, a voltage sag immunity standard, known as SEMI F47-0200, for semiconductor processing equipment manufacturers to conform to. Equipment compliant to this standard must have the specified immunity characteristics against voltage sags without the use of batteries. Based on the experience learned, the standard was redefined, in 2006, as SEMI F47-0706. It is expected that new semiconductor processing equipment will be designed to be compliant to the new standard. It is also likely that the SEMI F47-0706 requirement will be extended to other application areas. This paper describes the design of voltage sag compensators which can be operated in conjunction with a piece of equipment for SEMI F47 compliance. The voltage sag compensators described can provide sine-wave AC backup power to enable electronic equipment to meet the SEMI F47-0706 standard and to tolerate 100% momentary loss of AC mains voltage.
- 1 May 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2587-2590
Design of AC voltage sag compensators
AC operated electronic equipment are vulnerable to momentary losses of AC voltage, which are known as voltage sags. Voltage sags are commonly caused by lightning, accidental short circuit, loose connection, starting of large motors (or air-conditioners) or abnormal use of the AC mains. In sensitive and critical applications, such as semiconductor material processing and medical operation, voltage sags may result in serious problems. In order to tackle this problem, the Semiconductor Equipment and Materials International (SEMI) defined, in 1996, a voltage sag immunity standard, known as SEMI F47-0200, for semiconductor processing equipment manufacturers to conform to. Equipment compliant to this standard must have the specified immunity characteristics against voltage sags without the use of batteries. Based on the experience learned, the standard was redefined, in 2006, as SEMI F47-0706. It is expected that new semiconductor processing equipment will be designed to be compliant to the new standard. It is also likely that the SEMI F47-0706 requirement will be extended to other application areas. This paper describes the design of voltage sag compensators which can be operated in conjunction with a piece of equipment for SEMI F47 compliance. The voltage sag compensators described can provide sine-wave AC backup power to enable electronic equipment to meet the SEMI F47-0706 standard and to tolerate 100% momentary loss of AC mains voltage.
- 31 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 55 (2) , 665-673
Practical Design and Evaluation of a 1 kW PFC Power Supply Based on Reduced Redundant Power Processing Principle
Using the reduced redundant power processing (R2P2) principle, a single-phase power-factor correction (PFC) power supply can achieve a higher overall efficiency as a result of the use of a noncascading structure that involves less repeated processing of the input power. This paper investigates a single-phase noncascading PFC power supply based on the R2P2 principle. The circuit employs a current-fed full-bridge converter as the PFC preregulator, and a buck-boost converter as the voltage regulator. This paper addresses the design of this noncascading PFC power supply and in particular the relationships between the gained efficiency, the transient response and the size of the energy storage. Experimental results obtained from a 1 kW laboratory prototype are presented.
- 31 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 55 (2) , 665-673
Practical Design and Evaluation of a 1 kW PFC Power Supply Based on Reduced Redundant Power Processing Principle
Using the reduced redundant power processing (R2P2) principle, a single-phase power-factor correction (PFC) power supply can achieve a higher overall efficiency as a result of the use of a noncascading structure that involves less repeated processing of the input power. This paper investigates a single-phase noncascading PFC power supply based on the R2P2 principle. The circuit employs a current-fed full-bridge converter as the PFC preregulator, and a buck-boost converter as the voltage regulator. This paper addresses the design of this noncascading PFC power supply and in particular the relationships between the gained efficiency, the transient response and the size of the energy storage. Experimental results obtained from a 1 kW laboratory prototype are presented.
- 31 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 55 (2) , 817-831
A Four-Phase Forward Converter Using an Integrated Transformer
The interleaved converter topology has attractive features that include high output current, small output-current ripple, and fast transient response. In this paper, an interleaved four-phase forward converter using an integrated transformer is proposed for telecommunication and computer applications. The proposed converter requires only one integrated transformer instead of four step-down transformers. The z-parameter (gyrator) model and the equivalent-circuit model of the integrated transformer are derived. The circuit operation and design criteria are described. Theoretical analyses are verified by simulated and experimental results.
- 31 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 55 (2) , 817-831
A Four-Phase Forward Converter Using an Integrated Transformer
The interleaved converter topology has attractive features that include high output current, small output-current ripple, and fast transient response. In this paper, an interleaved four-phase forward converter using an integrated transformer is proposed for telecommunication and computer applications. The proposed converter requires only one integrated transformer instead of four step-down transformers. The z-parameter (gyrator) model and the equivalent-circuit model of the integrated transformer are derived. The circuit operation and design criteria are described. Theoretical analyses are verified by simulated and experimental results.
- 1 January 2008
- Published by Institution of Engineering and Technology (IET)
- p. 33-38
Feasibility of using building reinforced steel bars to transmit signals
Intelligent control, building automation, networking is a basic provisions for modern building as well as railway station building. All these systems rely on a physical layer to transmit signal. Wire, wireless and powerline physical layer are commonly used. However, all these layers have their limitations and associated problems especially in existing building. Existing building without sufficient spare cable containment for future wiring, concrete chasing to install new cable containment is unavoidable for wiring new network cables. In view of higher cost and great nuisance to the occupant during concrete chasing, a feasibility study of using building reinforced steel bars to transmit signals is discussed in this paper for future application. The principle of signal transmission in reinforced steel bars is similar as signal coupling in a transformer by means of magnetic flux coupling. Signals are transmitted as magnetic flux by means of a transmission coil, which is installed through reinforced steel bar and cast-in the concrete. The magnetic flux shall flow all around the reinforced steel bars framework of the entire building. Another coil acting as receiver is installed in a remote area to couple the magnetic flux and transform the signals from the transmission coil. From the experiments in laboratory and two construction buildings, it proved that the building reinforced steel bars framework is feasible as a physical data transmission media. Signals injected into reinforced steel bars can be received in remote area of the entire building in acceptance performance.
- 1 January 2008
- Published by Institution of Engineering and Technology (IET)
- p. 33-38
Feasibility of using building reinforced steel bars to transmit signals
Intelligent control, building automation, networking is a basic provisions for modern building as well as railway station building. All these systems rely on a physical layer to transmit signal. Wire, wireless and powerline physical layer are commonly used. However, all these layers have their limitations and associated problems especially in existing building. Existing building without sufficient spare cable containment for future wiring, concrete chasing to install new cable containment is unavoidable for wiring new network cables. In view of higher cost and great nuisance to the occupant during concrete chasing, a feasibility study of using building reinforced steel bars to transmit signals is discussed in this paper for future application. The principle of signal transmission in reinforced steel bars is similar as signal coupling in a transformer by means of magnetic flux coupling. Signals are transmitted as magnetic flux by means of a transmission coil, which is installed through reinforced steel bar and cast-in the concrete. The magnetic flux shall flow all around the reinforced steel bars framework of the entire building. Another coil acting as receiver is installed in a remote area to couple the magnetic flux and transform the signals from the transmission coil. From the experiments in laboratory and two construction buildings, it proved that the building reinforced steel bars framework is feasible as a physical data transmission media. Signals injected into reinforced steel bars can be received in remote area of the entire building in acceptance performance.