Nathan A. Tomlin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nathan A. Tomlin has a total of 168 co-authors. Here are the top co-authors by number of shared publications:
- Christopher S. Yung
Applied Physics Division, National Institute of Standards and Technology, Boulder, USA
6 shared publications - Michelle Stephens
National Institute of Standards and Technology, NIST
6 shared publications - Richard P. Mirin
National Institute of Standards and Technology 1 , Boulder, Colorado 80305
6 shared publications Brice Calkins
National Institute of Standards and Technology 1 , 325 Broadway St., Boulder, Colorado 80305, USA
5 shared publicationsJohn H. Lehman
National Institute of Standards and Technology (United States)
5 shared publicationsJohn Lehman
5 shared publications
Latest Publications
- Open Access
- 19 January 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (1)
Applying Heat Transport Modelling to Reduce Measurement Uncertainty of the LASP Reference Standard NACR8
Heat transport modelling of a planar absolute detector with vertically aligned carbon nanotube absorbers has been applied to the newly developed ambient-temperature electrical substitution radiometer (ESR), NACR8. Integrated into the Laboratory for Atmospheric and Space Physics (LASP) Total-solar-irradiance Radiometer Facility (TRF) NACR8 operates as an absolute optical power reference standard supporting validation of satellite based solar irradiance measurements, including those from the TSIS 2 TIM instrument. The modelling enables estimation and correction for electro-optical non-equivalence and its associated uncertainty, providing a generalised method applicable to planar thermal detectors. This approach represents an advancement in the understanding and correction of radiometric non-equivalence in optical radiation metrology. Traceability and performance of NACR8, incorporating a correction factor of 0.999562 with a standard uncertainty (u) = 0.000183 were confirmed through comparison with the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at 532.12 nm using a silicon photodiode light trapping transfer standard. Further comparison with NACR5, an established LASP optical power standard, showed agreement within stated uncertainties demonstrating the effectiveness of the heat transport modelling approach for addressing electro-optical non-equivalence in planar thermal detectors.
- 19 January 2026
- Published by IOP Publishing in Metrologia
- Vol. 63 (1)
Open AccessApplying Heat Transport Modelling to Reduce Measurement Uncertainty of the LASP Reference Standard NACR8
Heat transport modelling of a planar absolute detector with vertically aligned carbon nanotube absorbers has been applied to the newly developed ambient-temperature electrical substitution radiometer (ESR), NACR8. Integrated into the Laboratory for Atmospheric and Space Physics (LASP) Total-solar-irradiance Radiometer Facility (TRF) NACR8 operates as an absolute optical power reference standard supporting validation of satellite based solar irradiance measurements, including those from the TSIS 2 TIM instrument. The modelling enables estimation and correction for electro-optical non-equivalence and its associated uncertainty, providing a generalised method applicable to planar thermal detectors. This approach represents an advancement in the understanding and correction of radiometric non-equivalence in optical radiation metrology. Traceability and performance of NACR8, incorporating a correction factor of 0.999562 with a standard uncertainty (u) = 0.000183 were confirmed through comparison with the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at 532.12 nm using a silicon photodiode light trapping transfer standard. Further comparison with NACR5, an established LASP optical power standard, showed agreement within stated uncertainties demonstrating the effectiveness of the heat transport modelling approach for addressing electro-optical non-equivalence in planar thermal detectors.
- Open Access
- 3 December 2024
- Published by IOP Publishing in Metrologia
- Vol. 62 (1) , 015002
High-fidelity analysis of the electro-optical non-equivalence of planar electrical substitution radiometers*
We present the results of a finite element analysis of the electro-optical non-equivalence of planar electrical substitution radiometers with vertically aligned carbon nanotube absorbers, operating at either room or cryogenic temperature. These detectors are the basis of the new room temperature standards of the Laboratory for Atmospheric and Space Physics’ (LASP) Total solar irradiance Radiometer Facility and the Spectral solar irradiance Radiometer Facility, and the NIST Boulder open beam cryogenic radiometer facility. We show that the detector of our cryogenic electrical substitution radiometer has no significant electro-optical non-equivalence. Further, we also show that with careful detector design, the non-equivalence can be minimized at room temperature. It was found that in general the non-equivalence cannot be deduced from the temperature mismatch between the electrical and the optical states without considering the conductance mismatch and optical power input. The results are regarded as being precise rather than absolute to account for potentially unknown modeling errors. The numerical accuracy is typically less than 5 ppm.
- 3 December 2024
- Published by IOP Publishing in Metrologia
- Vol. 62 (1) , 015002
Open AccessHigh-fidelity analysis of the electro-optical non-equivalence of planar electrical substitution radiometers*
We present the results of a finite element analysis of the electro-optical non-equivalence of planar electrical substitution radiometers with vertically aligned carbon nanotube absorbers, operating at either room or cryogenic temperature. These detectors are the basis of the new room temperature standards of the Laboratory for Atmospheric and Space Physics’ (LASP) Total solar irradiance Radiometer Facility and the Spectral solar irradiance Radiometer Facility, and the NIST Boulder open beam cryogenic radiometer facility. We show that the detector of our cryogenic electrical substitution radiometer has no significant electro-optical non-equivalence. Further, we also show that with careful detector design, the non-equivalence can be minimized at room temperature. It was found that in general the non-equivalence cannot be deduced from the temperature mismatch between the electrical and the optical states without considering the conductance mismatch and optical power input. The results are regarded as being precise rather than absolute to account for potentially unknown modeling errors. The numerical accuracy is typically less than 5 ppm.
- 1 July 2024
- Published by Elsevier in Applied Materials Today
- Vol. 39
From nano to giant grains: Optimizing Pt thermistors for microbolometers
- 1 July 2024
- Published by Elsevier in Applied Materials Today
- Vol. 39
From nano to giant grains: Optimizing Pt thermistors for microbolometers
- Open Access
- 24 June 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045002
Direct implementation of a frequency-programmable Josephson voltage standard to provide an SI traceable optical power scale
We have developed a technique to determine the electrical substitution power of a cryogenic optical radiant power detector, that directly implements a frequency-programmable Josephson voltage standard (FPJVS), thus reducing the traceability chain. The optical power detector and the Josephson voltage reference are combined inside a common cryogenic environment. We demonstrate the practicality of the technique by using a FPJVS to apply a known voltage across the resistive heater of a standard NIST cryogenic planar radiometric detector. The power applied to the detector heater is calculated from a measurement of the heater resistance and the known applied voltage. The FPJVS dc bias current source supplies dc current to the resistive heater. In this demonstration, the standard uncertainty of the substituted electrical power is limited by the uncertainty of the electrical heater four-wire resistance measurement at 4 K. The uncertainty due to the resistance measurement is 1 part in 105out of a total uncertainty of 1 part in 104(k= 2) on the 1 mW optical power measurement. We aim to develop the technique, to provide traceability to the International System of Units for the picowatt power measurement of single-photon emitters such as quantum dot sources.
- 24 June 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (4) , 045002
Open AccessDirect implementation of a frequency-programmable Josephson voltage standard to provide an SI traceable optical power scale
We have developed a technique to determine the electrical substitution power of a cryogenic optical radiant power detector, that directly implements a frequency-programmable Josephson voltage standard (FPJVS), thus reducing the traceability chain. The optical power detector and the Josephson voltage reference are combined inside a common cryogenic environment. We demonstrate the practicality of the technique by using a FPJVS to apply a known voltage across the resistive heater of a standard NIST cryogenic planar radiometric detector. The power applied to the detector heater is calculated from a measurement of the heater resistance and the known applied voltage. The FPJVS dc bias current source supplies dc current to the resistive heater. In this demonstration, the standard uncertainty of the substituted electrical power is limited by the uncertainty of the electrical heater four-wire resistance measurement at 4 K. The uncertainty due to the resistance measurement is 1 part in 105out of a total uncertainty of 1 part in 104(k= 2) on the 1 mW optical power measurement. We aim to develop the technique, to provide traceability to the International System of Units for the picowatt power measurement of single-photon emitters such as quantum dot sources.
- Open Access
- 16 August 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (6) , 065006
Decadal validation of the LASP TRF cryogenic radiometer by NIST, and establishment of a replacement room temperature standard*
We present the results of a recent, extensive measurement campaign validating the traceability of the solar irradiance record and Earth radiation budget data. The campaign also established future traceability, thus ensuring confidence in the continuing climate-data record. The total solar irradiance radiometer facility (TRF) at the Laboratory for Atmospheric and Space Physics (LASP) Boulder, uses a liquid helium cooled cryogenic radiometer as the reference standard for the validation of spaceflight total solar irradiance (TSI) instrumentation. In 2008 the radiometer was directly compared to the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at a wavelength of 532.12 nm. At TSI power levels, a correction factor of 1.000 306 with an associated standard uncertainty (u) of 0.000 098, was reported for the TRF radiometer scale when using external voltage measurement electronics, and not correcting for cavity heating non-equivalence or cavity absorptance. The TRF radiometer has recently been revalidated at LASP using a POWR calibrated silicon photodiode trap transfer standard named TT4. We report a correction factor of 0.999 787, u = 0.000 285 to align the TRF radiometer scale with the current NIST POWR scale. A new room temperature reference standard radiometer was established. It measured 133 parts per million (ppm) higher than POWR using the same silicon transfer standard as above, and in a separate direct measurement, 168 ppm lower than the TRF radiometer shuttered at 400 s full shutter cycle. The difference agrees within stated uncertainties. A correction of 0.999 867, u = 0.000 247 will align the new radiometer scale with the NIST radiant power scale of POWR.
- 16 August 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (6) , 065006
Open AccessDecadal validation of the LASP TRF cryogenic radiometer by NIST, and establishment of a replacement room temperature standard*
We present the results of a recent, extensive measurement campaign validating the traceability of the solar irradiance record and Earth radiation budget data. The campaign also established future traceability, thus ensuring confidence in the continuing climate-data record. The total solar irradiance radiometer facility (TRF) at the Laboratory for Atmospheric and Space Physics (LASP) Boulder, uses a liquid helium cooled cryogenic radiometer as the reference standard for the validation of spaceflight total solar irradiance (TSI) instrumentation. In 2008 the radiometer was directly compared to the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at a wavelength of 532.12 nm. At TSI power levels, a correction factor of 1.000 306 with an associated standard uncertainty (u) of 0.000 098, was reported for the TRF radiometer scale when using external voltage measurement electronics, and not correcting for cavity heating non-equivalence or cavity absorptance. The TRF radiometer has recently been revalidated at LASP using a POWR calibrated silicon photodiode trap transfer standard named TT4. We report a correction factor of 0.999 787, u = 0.000 285 to align the TRF radiometer scale with the current NIST POWR scale. A new room temperature reference standard radiometer was established. It measured 133 parts per million (ppm) higher than POWR using the same silicon transfer standard as above, and in a separate direct measurement, 168 ppm lower than the TRF radiometer shuttered at 400 s full shutter cycle. The difference agrees within stated uncertainties. A correction of 0.999 867, u = 0.000 247 will align the new radiometer scale with the NIST radiant power scale of POWR.
- Open Access
- 1 February 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (2) , 025107
Room temperature laser power standard using a microfabricated, electrical substitution bolometer
The design and performance of a room temperature electrical substitution radiometer for use as an absolute standard for measuring continuous-wave laser power over a wide range of wavelengths, beam diameters, and powers are described. The standard achieves an accuracy of 0.46% (k = 2) for powers from 10 mW to 100 mW and 0.83% (k = 2) for powers from 1 mW to 10 mW and can accommodate laser beam diameters (1/e2) up to 11 mm and wavelengths from 300 nm to 2 μm. At low power levels, the uncertainty is dominated by sensitivity to fluctuations in the thermal environment. The core of the instrument is a planar, silicon microfabricated bolometer with vertically aligned carbon nanotube absorbers, commercial surface mount thermistors, and an integrated heater. Where possible, commercial electronics and components were used. The performance was validated by comparing it to a National Institute of Standards and Technology primary standard through a transfer standard silicon trap detector and by comparing it to the legacy “C-series” standards in operation at the U.S. Air Force Metrology and Calibration Division (AFMETCAL).
- 1 February 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (2) , 025107
Open AccessRoom temperature laser power standard using a microfabricated, electrical substitution bolometer
The design and performance of a room temperature electrical substitution radiometer for use as an absolute standard for measuring continuous-wave laser power over a wide range of wavelengths, beam diameters, and powers are described. The standard achieves an accuracy of 0.46% (k = 2) for powers from 10 mW to 100 mW and 0.83% (k = 2) for powers from 1 mW to 10 mW and can accommodate laser beam diameters (1/e2) up to 11 mm and wavelengths from 300 nm to 2 μm. At low power levels, the uncertainty is dominated by sensitivity to fluctuations in the thermal environment. The core of the instrument is a planar, silicon microfabricated bolometer with vertically aligned carbon nanotube absorbers, commercial surface mount thermistors, and an integrated heater. Where possible, commercial electronics and components were used. The performance was validated by comparing it to a National Institute of Standards and Technology primary standard through a transfer standard silicon trap detector and by comparing it to the legacy “C-series” standards in operation at the U.S. Air Force Metrology and Calibration Division (AFMETCAL).
- Open Access
- 1 May 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (5) , 055010
Overview of microfabricated bolometers with vertically aligned carbon nanotube absorbers
Multi-wall vertically aligned carbon nanotubes (VACNTs) are nearly ideal absorbers due to their exceptionally low reflectance over a broad wavelength range. Integrating VACNTs as bolometer absorbers, however, can be difficult due to their high growth temperature and fragile nature. Despite these challenges, we have microfabricated many different types of VACNT bolometers, ranging from cryogenic optical power primary standards to room temperature satellite-based solar irradiance monitors and broadband infrared microbolometers. Advantages our VACNT bolometers provide over the bolometers they replace vary by application, but can be reduced size and time constant, increased absorption, and/or microfabrication instead of hand assembly. Depending on the application and operating conditions, our VACNT bolometers are designed with a variety of thermistors and weak thermal links. The thermistors used include commercial surface mount chips, superconducting transition-edge sensors, and vanadium oxide (VOx). Weak thermal links include silicon nitride (SiNx) membranes, Si bridges, and laser-cut polyimide. We summarize a wide variety of microfabricated bolometers with VACNT absorbers that measure optical power levels spanning over seven orders of magnitude.
- 1 May 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (5) , 055010
Open AccessOverview of microfabricated bolometers with vertically aligned carbon nanotube absorbers
Multi-wall vertically aligned carbon nanotubes (VACNTs) are nearly ideal absorbers due to their exceptionally low reflectance over a broad wavelength range. Integrating VACNTs as bolometer absorbers, however, can be difficult due to their high growth temperature and fragile nature. Despite these challenges, we have microfabricated many different types of VACNT bolometers, ranging from cryogenic optical power primary standards to room temperature satellite-based solar irradiance monitors and broadband infrared microbolometers. Advantages our VACNT bolometers provide over the bolometers they replace vary by application, but can be reduced size and time constant, increased absorption, and/or microfabrication instead of hand assembly. Depending on the application and operating conditions, our VACNT bolometers are designed with a variety of thermistors and weak thermal links. The thermistors used include commercial surface mount chips, superconducting transition-edge sensors, and vanadium oxide (VOx). Weak thermal links include silicon nitride (SiNx) membranes, Si bridges, and laser-cut polyimide. We summarize a wide variety of microfabricated bolometers with VACNT absorbers that measure optical power levels spanning over seven orders of magnitude.
- 2 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11269, 112690L
Microfabricated bolometer based on a vertically aligned carbon nanotube absorber
We have designed a microfabricated planar absolute radiometer based on a vertically aligned carbon nanotube (VACNT) absorber and an electrical power substitution method. The radiometer is designed to operate at room temperature and to be capable of measuring laser powers up to 300 mW from 300 nm to 2300 nm with an expected expanded uncertainty of 0.06% (k = 2). The electrical power substitution capability makes the radiometer absolute and traceable to the international system (SI) of units. The new bolometer is currently under construction and will replace NIST's 50 year old detector standard for free-space CW laser power measurements. We also study the possibility of reducing background temperature sensitivity by optimizing the spectral selectivity of the VACNT forest with a photonic crystal structure.
- 2 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11269, 112690L
Microfabricated bolometer based on a vertically aligned carbon nanotube absorber
We have designed a microfabricated planar absolute radiometer based on a vertically aligned carbon nanotube (VACNT) absorber and an electrical power substitution method. The radiometer is designed to operate at room temperature and to be capable of measuring laser powers up to 300 mW from 300 nm to 2300 nm with an expected expanded uncertainty of 0.06% (k = 2). The electrical power substitution capability makes the radiometer absolute and traceable to the international system (SI) of units. The new bolometer is currently under construction and will replace NIST's 50 year old detector standard for free-space CW laser power measurements. We also study the possibility of reducing background temperature sensitivity by optimizing the spectral selectivity of the VACNT forest with a photonic crystal structure.
- 20 December 2019
- Published by IOP Publishing in Metrologia
- Vol. 57 (1) , 015001
Meta-study of laser power calibrations ranging 20 orders of magnitude with traceability to the kilogram
- 20 December 2019
- Published by IOP Publishing in Metrologia
- Vol. 57 (1) , 015001
Meta-study of laser power calibrations ranging 20 orders of magnitude with traceability to the kilogram
- 30 August 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11131, 4
The compact spectral irradiance monitor flight demonstration mission
Accurate, long-term solar spectral irradiance (SSI) measurements are vital for interpreting how solar variability impacts Earth’s climate and for validating climate model sensitivities to spectrally varying solar forcing. The Compact Spectral Irradiance Monitor (CSIM) 6U CubeSat successfully launched on Dec. 3rd, 2018 as part of the SpaceX SSO-A: SmallSat Express Mission ultimately achieving a sun-synchronous 575 km orbit. CSIM brings new, emerging technology advancements to maturation by demonstrating the unique capabilities of a complete SSI mission with inherent low mass and compact design. The instrument is a compact, two-channel prism spectral radiometer incorporating Si, InGaAs, and extended InGaAs focal plane photodiodes to record the solar spectrum daily across a continuous wavelength region spanning 200 – 2800 nm (>97% of the total solar irradiance). A new, novel electrical substitution radiometer (ESR) using vertically aligned carbon-nanotube (VACNT) bolometers serves as an absolute detector for periodic on-orbit spectral calibration corrections. Pre-launch component level performance characterizations and final instrument end-to-end absolute calibration achieved low combined standard uncertainty (uc<0.5%) in irradiance. These calibrations were performed in the LASP Spectral Radiometer Facility (SRF), a comprehensive spectral irradiance calibration facility utilizing a tunable laser system tied to an SI-traceable cryogenic radiometer. On-orbit, optical degradation corrections to better than 0.05% / year uncertainty are achieved by comparing periodic, simultaneous solar measurements of the two CSIM channels operating with significantly different solar exposure duty cycles. Operational overlap of CSIM with existing SSI measurements validate concepts for maintaining critical long-term solar data records.
- 30 August 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11131, 4
The compact spectral irradiance monitor flight demonstration mission
Accurate, long-term solar spectral irradiance (SSI) measurements are vital for interpreting how solar variability impacts Earth’s climate and for validating climate model sensitivities to spectrally varying solar forcing. The Compact Spectral Irradiance Monitor (CSIM) 6U CubeSat successfully launched on Dec. 3rd, 2018 as part of the SpaceX SSO-A: SmallSat Express Mission ultimately achieving a sun-synchronous 575 km orbit. CSIM brings new, emerging technology advancements to maturation by demonstrating the unique capabilities of a complete SSI mission with inherent low mass and compact design. The instrument is a compact, two-channel prism spectral radiometer incorporating Si, InGaAs, and extended InGaAs focal plane photodiodes to record the solar spectrum daily across a continuous wavelength region spanning 200 – 2800 nm (>97% of the total solar irradiance). A new, novel electrical substitution radiometer (ESR) using vertically aligned carbon-nanotube (VACNT) bolometers serves as an absolute detector for periodic on-orbit spectral calibration corrections. Pre-launch component level performance characterizations and final instrument end-to-end absolute calibration achieved low combined standard uncertainty (uc<0.5%) in irradiance. These calibrations were performed in the LASP Spectral Radiometer Facility (SRF), a comprehensive spectral irradiance calibration facility utilizing a tunable laser system tied to an SI-traceable cryogenic radiometer. On-orbit, optical degradation corrections to better than 0.05% / year uncertainty are achieved by comparing periodic, simultaneous solar measurements of the two CSIM channels operating with significantly different solar exposure duty cycles. Operational overlap of CSIM with existing SSI measurements validate concepts for maintaining critical long-term solar data records.