High-fidelity analysis of the electro-optical non-equivalence of planar electrical substitution radiometers*
Open Access
- 3 December 2024
- journal article
- research article
- Published by IOP Publishing in Metrologia
- Vol. 62 (1) , 015002
Abstract
We present the results of a finite element analysis of the electro-optical non-equivalence of planar electrical substitution radiometers with vertically aligned carbon nanotube absorbers, operating at either room or cryogenic temperature. These detectors are the basis of the new room temperature standards of the Laboratory for Atmospheric and Space Physics’ (LASP) Total solar irradiance Radiometer Facility and the Spectral solar irradiance Radiometer Facility, and the NIST Boulder open beam cryogenic radiometer facility. We show that the detector of our cryogenic electrical substitution radiometer has no significant electro-optical non-equivalence. Further, we also show that with careful detector design, the non-equivalence can be minimized at room temperature. It was found that in general the non-equivalence cannot be deduced from the temperature mismatch between the electrical and the optical states without considering the conductance mismatch and optical power input. The results are regarded as being precise rather than absolute to account for potentially unknown modeling errors. The numerical accuracy is typically less than 5 ppm.Keywords
Funding Information
- NASA Earth Science Technology Office (80NSSC18K1502)
This publication has 22 references indexed in Scilit:
- Decadal validation of the LASP TRF cryogenic radiometer by NIST, and establishment of a replacement room temperature standard*Metrologia, 2022
- Dual-mode room temperature self-calibrating photodiodes approaching cryogenic radiometer uncertaintyMetrologia, 2022
- High-accuracy room temperature planar absolute radiometer based on vertically aligned carbon nanotubesOptics Express, 2021
- Overview of microfabricated bolometers with vertically aligned carbon nanotube absorbersAIP Advances, 2020
- Compact total irradiance monitor flight demonstration2019
- Thermal conductivity of silicon nitride membranes is not sensitive to stressPhysical Review B, 2015
- Emissivity Measurement Under Vacuum from $4\,\upmu \hbox {m}$ 4 μ m to $100\,\upmu \hbox {m}$ 100 μ m and from $-40\,^{\circ }\hbox {C}$ - 40 ∘ C to $450\,^{\circ }\hbox {C}$ 450 ∘ C at PTBInternational Journal of Thermophysics, 2014
- Thermal performance of vertically-aligned multi-walled carbon nanotube array grown on platinum filmCarbon, 2014
- Predictable quantum efficient detector: II. Characterization and confirmed responsivityMetrologia, 2013
- Predictable quantum efficient detector: I. Photodiodes and predicted responsivityMetrologia, 2013