Bin Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bin Yu has a total of 184 co-authors. Here are the top co-authors by number of shared publications:
- Junle Qu
Shenzhen University
24 shared publications - Danying Lin
Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering
17 shared publications Junle Qu
Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education College of Physics and Optoelectronic Engineering Shenzhen University Shenzhen 518060 Guangdong Province China
7 shared publicationsSiwei Li
Shenzhen Univ, Ctr Biomed Photon, Shenzhen 518060, Peoples R China
7 shared publicationsDan-Ying Lin
Shenzhen Univ, Coll Phys & Optoelect Engn, Key Lab Optoelect Devices & Syst, Minist Educ & Guangdong Prov, Shenzhen 518060, Peoples R China
6 shared publicationsDanying Lin
Shenzhen Univ, Coll Phys & Optoelect Engn, Shenzhen Key Lab Photon & Biophoton, Key Lab Optoelect Devices & Syst,Minist Educ & Gu, Shenzhen 518060, Peoples R China
6 shared publications
Latest Publications
- 14 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Multifocal Pixel/Photon-Reassignment FLIM (MPPR-FLIM): A Super-Resolution Analytical Tool for Characterizing Subcellular Fluorescence Lifetime Heterogeneity via TCSPC
With the rapid progress of biomedical research, fluorescence lifetime imaging microscopy (FLIM) has been increasingly applied as a powerful tool to probe the microenvironmental properties of cells and tissues. However, conventional FLIM suffers from intrinsically limited spatial resolution, making it difficult to resolve the microenvironmental heterogeneity at the subcellular level. Although several approaches have been proposed to enhance the spatial resolution of FLIM, they often require custom-made optical components that hinder their practical implementation and widespread adoption. In this study, we present an alternative super-resolution FLIM technique termed multifocal pixel/photon-reassignment FLIM (MPPR-FLIM). This method employs a wide-field detector commonly used in super-resolution fluorescence intensity imaging, combined with a single-point detector and a time-correlated single-photon counting (TCSPC) module, both of which are standard components in conventional FLIM systems (no custom fabrication required). By simultaneously acquiring structural and lifetime information from the sample using a specially designed synchronization strategy, coupled with a postacquisition data remapping algorithm integrating both pixel reassignment and photon reassignment, MPPR-FLIM achieves a ∼2.1-fold improvement in spatial resolution compared with conventional TCSPC-FLIM systems. Furthermore, through the imaging of lysosomes in live cells, we demonstrate the potential of MPPR-FLIM for characterizing subcellular compartment-specific fluorescence lifetime variations. This capability may facilitate investigations into the potential relationship between subcellular lifetime heterogeneity and cellular functions, offering a practical and accessible super-resolution analytical tool for biomedical and life science research.
- 14 June 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Multifocal Pixel/Photon-Reassignment FLIM (MPPR-FLIM): A Super-Resolution Analytical Tool for Characterizing Subcellular Fluorescence Lifetime Heterogeneity via TCSPC
With the rapid progress of biomedical research, fluorescence lifetime imaging microscopy (FLIM) has been increasingly applied as a powerful tool to probe the microenvironmental properties of cells and tissues. However, conventional FLIM suffers from intrinsically limited spatial resolution, making it difficult to resolve the microenvironmental heterogeneity at the subcellular level. Although several approaches have been proposed to enhance the spatial resolution of FLIM, they often require custom-made optical components that hinder their practical implementation and widespread adoption. In this study, we present an alternative super-resolution FLIM technique termed multifocal pixel/photon-reassignment FLIM (MPPR-FLIM). This method employs a wide-field detector commonly used in super-resolution fluorescence intensity imaging, combined with a single-point detector and a time-correlated single-photon counting (TCSPC) module, both of which are standard components in conventional FLIM systems (no custom fabrication required). By simultaneously acquiring structural and lifetime information from the sample using a specially designed synchronization strategy, coupled with a postacquisition data remapping algorithm integrating both pixel reassignment and photon reassignment, MPPR-FLIM achieves a ∼2.1-fold improvement in spatial resolution compared with conventional TCSPC-FLIM systems. Furthermore, through the imaging of lysosomes in live cells, we demonstrate the potential of MPPR-FLIM for characterizing subcellular compartment-specific fluorescence lifetime variations. This capability may facilitate investigations into the potential relationship between subcellular lifetime heterogeneity and cellular functions, offering a practical and accessible super-resolution analytical tool for biomedical and life science research.
- 2 January 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (1) , 54-65
Paralleled needle-like-beam image scanning microscopy for fast volumetric super-resolution imaging
Super-resolution (SR) fluorescence microscopy has proven to be an essential tool for investigating intricate biological systems. However, it frequently encounters challenges related to speed and complexity when conducting volumetric imaging of thick samples. Herein, we present an enhanced variant of parallelized image scanning microscopy (ISM) to address these challenges. By incorporating a pinhole in the illumination path to generate a needle-like beam that extends the depth of focus (DOF) of the focused beam array, the system enables synchronized capture of multifocal signals from eight distinct sample planes in combination with a multiplane prism. Notably, through improvements in the reconstruction algorithm, this method significantly reduces the required number of raw frames, shortening the SR imaging time for a volume of approximately 42 × 37 × 1.9 μm 3 to sub-second-scale while maintaining axial imaging synchronization. This breakthrough enables the real-time SR volumetric imaging of thin biological samples, which we successfully demonstrated on live cell samples. Furthermore, we validated the rapid SR imaging capabilities of the system through experiments on various fluorescent samples, demonstrating its potential for transformative applications in biomedical imaging.
- 2 January 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (1) , 54-65
Paralleled needle-like-beam image scanning microscopy for fast volumetric super-resolution imaging
Super-resolution (SR) fluorescence microscopy has proven to be an essential tool for investigating intricate biological systems. However, it frequently encounters challenges related to speed and complexity when conducting volumetric imaging of thick samples. Herein, we present an enhanced variant of parallelized image scanning microscopy (ISM) to address these challenges. By incorporating a pinhole in the illumination path to generate a needle-like beam that extends the depth of focus (DOF) of the focused beam array, the system enables synchronized capture of multifocal signals from eight distinct sample planes in combination with a multiplane prism. Notably, through improvements in the reconstruction algorithm, this method significantly reduces the required number of raw frames, shortening the SR imaging time for a volume of approximately 42 × 37 × 1.9 μm 3 to sub-second-scale while maintaining axial imaging synchronization. This breakthrough enables the real-time SR volumetric imaging of thin biological samples, which we successfully demonstrated on live cell samples. Furthermore, we validated the rapid SR imaging capabilities of the system through experiments on various fluorescent samples, demonstrating its potential for transformative applications in biomedical imaging.
- 10 March 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (6) , 2005-2008
Resolution-enhanced multifocal structured illumination microscopy using fluorescence fluctuations and Fourier ptychography scheme
Multifocal structured illumination microscopy (MSIM) provides a twofold resolution enhancement over the optical diffraction limit at depths of up to 50 μm in samples. This is achieved through sparse multifocal excitation patterns and digital image post-processing, making MSIM a highly advantageous technique for the three-dimensional super-resolution (SR) imaging of thick specimens. However, the spatial resolution of MSIM is inherently constrained by its underlying imaging principles. This paper presents what we believe to be a novel method that integrates SR optical fluctuation imaging based on Fourier ptychography and deconvolution (SFPD) with MSIM, termed SFPD–MSIM. Using photoblinking InP/ZnSe/ZnS core-shell quantum dot fluorescent probes for sample labeling, we demonstrate that, compared to wide-field imaging microscopy, SFPD–MSIM achieves fourfold resolution improvement. Additionally, it substantially reduces the image-acquisition time while preserving the structural integrity of the original samples. This advancement marks a major step forward in MSIM technology, providing a powerful tool for detailed structural analysis of complex and thick biological specimens.
- 10 March 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (6) , 2005-2008
Resolution-enhanced multifocal structured illumination microscopy using fluorescence fluctuations and Fourier ptychography scheme
Multifocal structured illumination microscopy (MSIM) provides a twofold resolution enhancement over the optical diffraction limit at depths of up to 50 μm in samples. This is achieved through sparse multifocal excitation patterns and digital image post-processing, making MSIM a highly advantageous technique for the three-dimensional super-resolution (SR) imaging of thick specimens. However, the spatial resolution of MSIM is inherently constrained by its underlying imaging principles. This paper presents what we believe to be a novel method that integrates SR optical fluctuation imaging based on Fourier ptychography and deconvolution (SFPD) with MSIM, termed SFPD–MSIM. Using photoblinking InP/ZnSe/ZnS core-shell quantum dot fluorescent probes for sample labeling, we demonstrate that, compared to wide-field imaging microscopy, SFPD–MSIM achieves fourfold resolution improvement. Additionally, it substantially reduces the image-acquisition time while preserving the structural integrity of the original samples. This advancement marks a major step forward in MSIM technology, providing a powerful tool for detailed structural analysis of complex and thick biological specimens.
- Open Access
- 13 February 2025
- Published by Wiley in Nanophotonics
- Vol. 14 (4) , 535-543
Localizing axial dense emitters based on single‐helix point spread function and compressed sensing
Among the approaches in three‐dimensional (3D) single molecule localization microscopy, there are several point spread function (PSF) engineering approaches, in which depth information of molecules is encoded in 2D images. Usually, the molecules are excited sparsely in each raw image. The consequence is that the temporal resolution has to be sacrificed. In order to improve temporal resolution and ensure localization accuracy, we propose a method, SH‐CS, based on light needle excitation, detection system with single helix‐point spread function (SH‐PSF), and compressed sensing (CS). Although the SH‐CS method still has a limitation about the molecule density, it is suited for relatively dense molecules. For each light needle scanning position, an SH image of excited molecules is processed with CS algorithm to decode their axial information. Simulations demonstrated, for random distributed 1–15 molecules in depth range of 4 μm, the axial localization accuracy is 12.1–73.5 nm. The feasibility of this method is validated with a designed 3D sample composed of fluorescent beads.
- 13 February 2025
- Published by Wiley in Nanophotonics
- Vol. 14 (4) , 535-543
Open AccessLocalizing axial dense emitters based on single‐helix point spread function and compressed sensing
Among the approaches in three‐dimensional (3D) single molecule localization microscopy, there are several point spread function (PSF) engineering approaches, in which depth information of molecules is encoded in 2D images. Usually, the molecules are excited sparsely in each raw image. The consequence is that the temporal resolution has to be sacrificed. In order to improve temporal resolution and ensure localization accuracy, we propose a method, SH‐CS, based on light needle excitation, detection system with single helix‐point spread function (SH‐PSF), and compressed sensing (CS). Although the SH‐CS method still has a limitation about the molecule density, it is suited for relatively dense molecules. For each light needle scanning position, an SH image of excited molecules is processed with CS algorithm to decode their axial information. Simulations demonstrated, for random distributed 1–15 molecules in depth range of 4 μm, the axial localization accuracy is 12.1–73.5 nm. The feasibility of this method is validated with a designed 3D sample composed of fluorescent beads.
- 4 February 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (6) , 3337-3343
UNET-FLIM: A Deep Learning-Based Lifetime Determination Method Facilitating Real-Time Monitoring of Rapid Lysosomal pH Variations in Living Cells
Lifetime determination plays a crucial role in fluorescence lifetime imaging microscopy (FLIM). We introduce UNET-FLIM, a deep learning architecture based on a one-dimensional U-net, specifically designed for lifetime determination. UNET-FLIM focuses on handling low photon count data with high background noise levels, which are commonly encountered in fast FLIM applications. The proposed network can be effectively trained using simulated decay curves, making it adaptable to various time-domain FLIM systems. Our evaluations of simulated data demonstrate that UNET-FLIM robustly estimates lifetimes and proportions, even when the signal photon count is extremely low and background noise levels are high. Remarkably, UNET-FLIM's insensitivity to noise and minimal photon count requirements facilitate fast FLIM imaging and real-time lifetime analysis. We demonstrate its potential by applying it to monitor rapid lysosomal pH variations in living cells during in situ acetic acid treatment, all without necessitating any modifications to existing FLIM systems.
- 4 February 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (6) , 3337-3343
UNET-FLIM: A Deep Learning-Based Lifetime Determination Method Facilitating Real-Time Monitoring of Rapid Lysosomal pH Variations in Living Cells
Lifetime determination plays a crucial role in fluorescence lifetime imaging microscopy (FLIM). We introduce UNET-FLIM, a deep learning architecture based on a one-dimensional U-net, specifically designed for lifetime determination. UNET-FLIM focuses on handling low photon count data with high background noise levels, which are commonly encountered in fast FLIM applications. The proposed network can be effectively trained using simulated decay curves, making it adaptable to various time-domain FLIM systems. Our evaluations of simulated data demonstrate that UNET-FLIM robustly estimates lifetimes and proportions, even when the signal photon count is extremely low and background noise levels are high. Remarkably, UNET-FLIM's insensitivity to noise and minimal photon count requirements facilitate fast FLIM imaging and real-time lifetime analysis. We demonstrate its potential by applying it to monitor rapid lysosomal pH variations in living cells during in situ acetic acid treatment, all without necessitating any modifications to existing FLIM systems.
- 11 December 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (51) , 35039-35051
Tm3+-Based Downshifting Nanoprobes with Enhanced Luminescence at 1680 nm for In Vivo Vascular Growth Monitoring
Optical imaging in the 1500-1700 nm region, known as near-infrared IIb (NIR-IIb), shows potential for noninvasive in vivo detection owing to its ultrahigh tissue penetration depth and spatiotemporal resolution. Rare earth-doped nanoparticles have emerged as widely used NIR-IIb probes because of their excellent optical properties. However, their downshifting emissions rarely exhibit sufficient brightness beyond 1600 nm. This study presents tetragonal-phase thulium-doped nanoparticles (Tm3+-NPs) with core-shell-shell structures (CSS, LiYbF4:3%Tm@LiYbF4@LiYF4) that exhibit bright downshifting luminescence at 1680 nm. Enhanced luminescence is attributed to (1) the promoted nonradiative relaxation between the doping ions and (2) the maximized sensitization process. Additionally, this strategy was validated for NIR-IIb luminescence enhancement of erbium (Er3+)-doped NPs. After surface modification with PEGylated liposomes, tetragonal-phase Tm3+-NPs exhibited a prolonged blood cycle time, high colloidal stability, and good biocompatibility. Owing to the advantages of Tm3+-based probes in NIR-IIb imaging, in vivo thrombus detection and monitoring of angiogenesis and arteriogenesis were successfully performed in a mouse model of ischemic hind limbs.
- 11 December 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (51) , 35039-35051
Tm3+-Based Downshifting Nanoprobes with Enhanced Luminescence at 1680 nm for In Vivo Vascular Growth Monitoring
Optical imaging in the 1500-1700 nm region, known as near-infrared IIb (NIR-IIb), shows potential for noninvasive in vivo detection owing to its ultrahigh tissue penetration depth and spatiotemporal resolution. Rare earth-doped nanoparticles have emerged as widely used NIR-IIb probes because of their excellent optical properties. However, their downshifting emissions rarely exhibit sufficient brightness beyond 1600 nm. This study presents tetragonal-phase thulium-doped nanoparticles (Tm3+-NPs) with core-shell-shell structures (CSS, LiYbF4:3%Tm@LiYbF4@LiYF4) that exhibit bright downshifting luminescence at 1680 nm. Enhanced luminescence is attributed to (1) the promoted nonradiative relaxation between the doping ions and (2) the maximized sensitization process. Additionally, this strategy was validated for NIR-IIb luminescence enhancement of erbium (Er3+)-doped NPs. After surface modification with PEGylated liposomes, tetragonal-phase Tm3+-NPs exhibited a prolonged blood cycle time, high colloidal stability, and good biocompatibility. Owing to the advantages of Tm3+-based probes in NIR-IIb imaging, in vivo thrombus detection and monitoring of angiogenesis and arteriogenesis were successfully performed in a mouse model of ischemic hind limbs.
- 25 October 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (21) , 6193-6196
Addressable scanning multifocal structured illumination microscopy using acousto-optic deflectors
Multifocal structured illumination microscopy (MSIM) is a popular super-resolution imaging technique known for its good probe compatibility, low laser power requirements, and improved imaging depth, making it widely applicable in biomedical research. However, the speed of MSIM imaging is typically constrained by the approaches employed to generate and scan the laser foci across the sample. In this study, we propose a flexible two-photon excitation MSIM method using a pair of acousto-optic deflectors. By adopting addressable scanning (AS) and synchronized capturing, MSIM super-resolution imaging can be performed in multiple discrete regions of interest (ROIs) within the field of view. Notably, this AS-MSIM scheme not only enhances the speed of MSIM imaging but also alleviates photobleaching and phototoxicity to biological samples. We demonstrate its potential by achieving super-resolution imaging of selected mitochondria within cells at a frame rate of 4 Hz. Furthermore, we deliberate the possibility of even faster imaging.
- 25 October 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (21) , 6193-6196
Addressable scanning multifocal structured illumination microscopy using acousto-optic deflectors
Multifocal structured illumination microscopy (MSIM) is a popular super-resolution imaging technique known for its good probe compatibility, low laser power requirements, and improved imaging depth, making it widely applicable in biomedical research. However, the speed of MSIM imaging is typically constrained by the approaches employed to generate and scan the laser foci across the sample. In this study, we propose a flexible two-photon excitation MSIM method using a pair of acousto-optic deflectors. By adopting addressable scanning (AS) and synchronized capturing, MSIM super-resolution imaging can be performed in multiple discrete regions of interest (ROIs) within the field of view. Notably, this AS-MSIM scheme not only enhances the speed of MSIM imaging but also alleviates photobleaching and phototoxicity to biological samples. We demonstrate its potential by achieving super-resolution imaging of selected mitochondria within cells at a frame rate of 4 Hz. Furthermore, we deliberate the possibility of even faster imaging.
- 23 October 2024
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 14 (21) , 16479-16487
Unified Enantioselective Allylations and Vinylogous Reactions Enabled by Visible Light-Driven Chiral Lewis Acid Catalysis
- 23 October 2024
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 14 (21) , 16479-16487
Unified Enantioselective Allylations and Vinylogous Reactions Enabled by Visible Light-Driven Chiral Lewis Acid Catalysis
- Open Access
- 8 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (6) , 1-6
Localizing Axial Dense Emitters Based on Single-Helix Point Spread Function and Deep Learning
The point-by point 3D scanning strategy adopted in Stimulated Emission Depletion Microscopy (STED) is time-consuming. The 3D scanning can be replaced with a 2D scanning in the non-diffracting Bessel-Bessel STED (BB-STED). In order to extract the excited emitters' axial information in BB-STED, we propose to encode axial information by using a detection optical path with single-helix PSF, and then predict the depths of the emitters with deep learning. Simulation demonstrated that, for dense emitters in a depth range of 4 μm, an axial precision of ∼35 nm can be achieved. Our method also works for experimental data, and an axial precision of ∼63 nm can be achieved.
- 8 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (6) , 1-6
Open AccessLocalizing Axial Dense Emitters Based on Single-Helix Point Spread Function and Deep Learning
The point-by point 3D scanning strategy adopted in Stimulated Emission Depletion Microscopy (STED) is time-consuming. The 3D scanning can be replaced with a 2D scanning in the non-diffracting Bessel-Bessel STED (BB-STED). In order to extract the excited emitters' axial information in BB-STED, we propose to encode axial information by using a detection optical path with single-helix PSF, and then predict the depths of the emitters with deep learning. Simulation demonstrated that, for dense emitters in a depth range of 4 μm, an axial precision of ∼35 nm can be achieved. Our method also works for experimental data, and an axial precision of ∼63 nm can be achieved.
- 11 March 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (6) , 1540-1543
Polarization-resolved super-resolution second-harmonic generation imaging based on multifocal structured illumination microscopy
Polarization-resolved second-harmonic generation (PSHG) microscopy is widely used in investigating the structural and morphological alterations of collagen. However, the resolution of second-harmonic generation (SHG) imaging remains constrained by optical diffraction, resulting in the polarization extraction of collagen characteristics from the average properties of collagen fibers. In this study, multifocal structured illumination microscopy (MSIM) was combined with PSHG to achieve polarization-resolved super-resolution imaging of second-harmonic generation signals. For the first time to our knowledge, periodic structures with an average pitch of 277 nm were observed in mouse tail tendons using optical microscopy, and the orientation angle of fibrils within each period was found to exhibit an alternating arrangement along the axis in a regular pattern.
- 11 March 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (6) , 1540-1543
Polarization-resolved super-resolution second-harmonic generation imaging based on multifocal structured illumination microscopy
Polarization-resolved second-harmonic generation (PSHG) microscopy is widely used in investigating the structural and morphological alterations of collagen. However, the resolution of second-harmonic generation (SHG) imaging remains constrained by optical diffraction, resulting in the polarization extraction of collagen characteristics from the average properties of collagen fibers. In this study, multifocal structured illumination microscopy (MSIM) was combined with PSHG to achieve polarization-resolved super-resolution imaging of second-harmonic generation signals. For the first time to our knowledge, periodic structures with an average pitch of 277 nm were observed in mouse tail tendons using optical microscopy, and the orientation angle of fibrils within each period was found to exhibit an alternating arrangement along the axis in a regular pattern.