TTTamaki Takano

Tamaki Takano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tamaki Takano has a total of 120 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pilot study of Wilms tumor 1-targeted human platelet lysate-induced antigen-presenting cells in advanced solid cancer patients

    by Misa Togi, Terutsugu Koya, Kenichi Yoshida, Haruhiko Kawaguchi, Tamaki Takano, Sohsuke Yamada, Tsung-Jang Yeh, Yi-Chang Liu, Haruo Sugiyama, Shigeo Koido, et al.

  • Open Access

    Impact of Compound Disasters on Surgical Interventions for Infective Endocarditis: Insights from COVID-19 and the 2024 Noto Earthquake

    by Ko Miyazawa, Takuya Sakamoto, Daisuke Sakamoto, Tsugiyasu Kanda, Tamaki Takano

    The concurrent occurrence of COVID-19 and the 2024 Noto Peninsula earthquake resulted in a “compound disaster” in Japan. This retrospective study, spanning 11 years (2015–2025), examines the impact of these crises on trends in cardiovascular surgery, focusing on infective endocarditis (IE). A total of 2444 surgical cases were analyzed across three distinct periods: pre-pandemic (2015–2019), pandemic (2020–2023), and compound disasters (2024). While overall surgical volumes exhibited fluctuations, there was a notable increase in the number of interventions for IE and renal failure in 2024. Additionally, the 2024 IE cohort revealed a significant epidemiological shift, characterized by a younger median age (56 years compared to 70 years pre-pandemic), absence of pre-existing valvular disease, and a marked rise in blood culture-negative endocarditis (BCNE), which accounted for 83.3% of IE cases. In 2025, the number of surgical IE cases decreased to zero, highlighting the acute nature of the peak in 2024. These findings illustrate that compound disasters can disrupt cardiovascular surgical trends and underscore the susceptibility of IE to compromised healthcare access and environmental stress. The development of resilient diagnostic pathways is essential for managing complex public health emergencies.

  • Open Access

    A Case of Decreased Swallowing Function Due to Cardiac Myxoma

    by Sumiyo Akazawa, Seiko Miura, Yasuhiro Nagayoshi, Junya Fukushima, Takahiro Nishino, Hiroji Nagata, Taigo Nagayama, Kazuaki Nishiki, Taishi Fujii, Daisuke Sakamoto, et al.

    症例は77歳,男性.2年前からめまい・嚥下機能低下があり,むせ,血痰も伴い内科で精査が行われ,原因不明の嚥下機能低下による誤嚥性肺炎の入院歴がある.今回動悸・息切れを伴い近医受診した.心臓超音波検査では,左房内腫瘍が心拍動に伴って僧帽弁に嵌頓していた.当院心臓血管外科で緊急左房粘液腫摘出術,Patch Closureが施行された.摘出術後,嚥下機能が回復したことから術後Ortner症候群と診断された.嚥下機能低下,めまいの原因精査として心臓超音波検査が重要と考えられた一例を経験したので報告する.

  • Open Access

    Racemose hemangioma revealed by massive intraoperative hemorrhage

    by Shun Iwai, Masahito Ishikawa, Yoshihito Iijima, Nozomu Motono, Hiroji Nagata, Tamaki Takano, Hidetaka Uramoto

    Introduction and importance: Bronchial arterial racemose hemangioma is considered to be a type of pulmonary arteriovenous malformation (PAVM). We encountered an extremely rare case of racemose hemangioma, which was identified because of massive bleeding during lung cancer surgery. Case presentation: A 71-year-old man was suspected of having lung cancer and underwent a right upper lobectomy. During the dissection of the peribronchial connective tissue around the upper lobe bronchus, a sudden massive hemorrhage occurred after separation of the pulmonary artery and vein. Hemostasis was difficult to achieve with compression hemostasis and the point of bleeding was unknown; thus, we were called in to search for the source of the bleeding, which was identified as the bronchial artery. Postoperatively, a racemose hemangioma was diagnosed via preoperative chest computed tomography and imaging analysis with the Ziostation2® (Ziosoft Inc. Tokyo, Japan). Clinical discussion: Racemose hemangioma has weaker blood vessel walls than normal blood vessels. Once bleeding occurs, it is very difficult to stop. However, once the bleeding point was identified, hemostasis via suturing and cutting was possible. Conclusion: As hemorrhaging from a racemose hemangioma is very difficult to stop, preoperative imaging retrieval is very important. Highlights:


  • Open Access

    Mini open stent grafting with half sternotomy for aortic arch aneurysm

    by Tamaki Takano, Masayuki Sakaguchi, Takamitsu Terasaki, Taishi Fujii, Yusuke Date, Mugumi Fuke, Kai Machida

    Open stent grafting is an alternative of graft replacement and thoracic endovascular aortic repair for aortic arch aneurysm. We have performed open stent grafting with half sternotomy (mini-OSG) to reduce in-hospital stay and recovery time of patients and herein report seven cases of mini-OSG for aortic aneurysm and dissection. The patients’ mean age was 66 years. Cardiopulmonary bypass was performed conventionally, and an open stent graft was inserted via an aortotomy on the aortic arch during circulatory arrest. No mortality occurred. The mean operation time was 387 min, and the mean blood loss was 587 ml. The patients were weaned from the ventilator 7.1 h postoperatively. No pseudoaneurysm or endoleakage was observed during the 2- to 20-month follow-up. Mini-OSG might be less invasive, although further studies and intensive follow-up are needed.

  • Open Access

    Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system

    by Yuki Michinaga, Tamaki Takano, Takamitsu Terasaki, Souma Miyazaki, Noritoshi Kikuchi, Kenji Okada

    Introduction: We have been developing a closed-circuit cardiopulmonary bypass (CPB) system (“Dihead CPB”) for application during coronary artery bypass grafting (CABG) and valve surgery. To strive for minimal hemolysis during Dihead CPB, we compared the hemolysis caused by three different suction systems and performed a clinical study with the newly applied suction system. Materials & Methods: We evaluated the hemolysis caused by roller-pump suction, the SmartSuction® Harmony® and wall suction systems with respect to suction speed and compared the systems by means of in vitro studies. A clinical study was also performed on 15 volunteers to assess hemolysis and the adequacy of the newly applied suction system with Dihead CPB. Results: Pressure inside the suction cannula was −22.5 ± 0.1 mmHg at a maximum flow of 1.5 L/min for roller-pump suction and −43.4 ± 0.1 mmHg at −150 mmHg of the set vacuum pressure of wall suction. With the SmartSuction, the pressure inside the cannula varied from −76.3 ± 1.0 to −130.3 ± 1.5 mmHg, depending on suctioning conditions. Suction speed (to suction 50 ml of blood) was fastest with the SmartSuction (69.7 ± 3.58 s) whereas, with roller suction, it was 117.3 ± 8.47 s and with wall suction 96.9 ± 7.10 s. The SmartSuction had the highest hemolysis rate (2.00 ± 0.33%) vs. 0.61 ± 0.10% for roller suction and 0.41 ± 0.11% for wall suction (p<0.001). The clinical study with wall suction showed no significant increase in plasma free hemoglobin during or after CPB compared with before surgery. Conclusions: Wall suction had less hemolysis than roller suction or the SmartSuction in the in vitro study and the clinical study with wall suction showed efficient suction speed and acceptable hemolysis, suggesting that Dihead CPB with wall suction is feasible for CABG.


  • Open Access

    Open stent graft repair with upper-half Sternotomy for blunt thoracic aortic injury: a case report

    by Toshinori Komatsu, Tamaki Takano, Hiromu Kehara, Megumi Fuke, Takamitsu Terasaki, Masayuki Sakaguchi

    Thoracic endovascular aortic repair is now widely applied to the treatment of blunt aortic injury. However, its long-term outcomes remain unclear. Endoleakage and migration might occur in the long term, especially when younger patients undergo endovascular aortic repair. In open stent grafting, the proximal end of the open stent graft is directly sutured to the native aorta, which may reduce the risk of endoleakage and migration. We applied open stent grafting to the treatment of blunt aortic injury in the subacute phase and herein report the patient’s clinical course. A 20-year-old man with a developmental disorder collided with a steel tower while skiing. He was transferred to our hospital by helicopter. X-ray examination and computed tomography revealed fractures of left humeral head and femoral neck and aortic isthmus dissection. We did not perform an acute-phase operation because of the presence of multiple trauma and instead performed open stent grafting with an upper-half sternotomy 42 days after the injury. He recovered uneventfully without psychological problems other than his preexisting developmental disorder. No endoleakage or aneurysm was observed during an 18-month follow-up period. Open stent grafting might be an alternative to open surgery and thoracic endovascular aortic repair for blunt chest trauma, although intensive follow-up is needed.


  • Biventricular support using a centrifugal pump in a 6 year old with fulminant myocarditis

    by Hiromu Kehara, Tamaki Takano, Takamitsu Terasaki, Kenji Okada

    We experienced a case of ventricular assist with both a pulsatile-flow and a continuous-flow pump in a pediatric patient, and herein report the clinical course and characteristics of the pumps. A 6-year-old female was diagnosed with fulminant myocarditis and transferred to our hospital for mechanical support. After 12 days of extracorporeal membrane oxygenation, we implanted a left ventricular assist device (LVAD) and a right ventricular assist device (RVAD) using centrifugal Gyro pumps with a membrane oxygenator in a paracorporeal fashion. The membrane oxygenator was removed on postoperative day (POD) 4, and the patient was weaned from the respirator on POD 6. The LVAD was exchanged on POD 13 and 17, and the RVAD was exchanged on POD 14 because of thrombus formation inside the pumps. The RVAD was removed on POD 25. On POD 32, the patient experienced cerebral infarction and the centrifugal Gyro pump was switched to an extracorporeal pulsatile pump. No thromboembolic event occurred after pump conversion, although continuous administration of vasodilators was required to avoid hypertension. She underwent successfully heart transplantation in the USA after 8 months of ventricular support. A centrifugal pump is considered useful for pediatric patients, as pump flow and blood pressure can be relatively easily controlled in the postoperative acute phase compared with the pulsatile pump. However, special care should be taken to monitor for thrombus formation when support length becomes longer than 13 days, and a switch to a pulsatile pump should be considered once the hemodynamic status stabilizes.


  • Open Access

    Hemolytic anemia caused by aortic flap and inversion of felt strip after ascending aorta replacement

    by Masayuki Sakaguchi, Tamaki Takano

    Hemolysis related to a kinked prosthetic graft or inner felt strip is a very rare complication after aortic surgery. We describe herein a case of hemolytic anemia that developed due to aortic flap of the dissection and inversion of an inner felt strip that was applied at the proximal anastomosis of a replaced ascending aorta 10 years previously. A 74-year-old woman presented with consistent hemolytic anemia 10 years after replacement of the ascending aorta to treat Stanford type A acute aortic dissection. The cause of hemolysis was attributed to mechanical injury of red blood cells at a site of stenosis caused by aortic flap of the dissection and inversion of the felt strip used for the proximal anastomosis. Repeated resection of the strip and graft replacement of the ascending aorta resolved this problem. We considered that blood flow disrupted by a jet of blood at the site of the proximal inner felt strip was the cause of severe hemolysis, we describe rare hemolytic anemia at the site of aortic flap and inverted felt strip after replacement of the ascending aorta.


  • Open Access

    Pseudoaneurysm of graft–graft anastomosis of a hand-sewn branched graft: a case report

    by Toshihito Gomibuchi, Tamaki Takano, Yuko Wada, Takamitsu Terasaki, Tatsuichiro Seto, Daisuke Fukui

    Pseudoaneurysm of graft–graft anastomosis is an extremely rare but potentially fatal complication after thoracic aorta replacement with a prosthetic graft. We report a case of pseudoaneurysm at the graft–graft anastomosis of a hand-sewn branched graft. A 65-year-old man underwent total arch replacement with a hand-sewn branched graft for Stanford type A acute aortic dissection 22 years ago. During follow-up, serial CT scans showed a pseudoaneurysm on the branched graft which warranted reintervention. Surgical repair involved direct suture of multiple bleeding points which were found at the sites of the hand-sewn branches anastomosis. The postoperative course was uneventful, and no signs of bleeding were observed by CT after the reoperation. Long-term follow-up is essential to detect late complications at the site of hand-sewn anastomosis.