Mehmet Dalkiz
Research Subjects
Mehmet Dalkiz has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Halil Aykul
4 shared publicationsEmre Özyilmaz
3 shared publicationsH. Ali Çetinkara
3 shared publications- Bedri Beydemir
University of Health Sciences
2 shared publications Hatice Zehra Akbas
Mustafa Kemal University
2 shared publicationsA. U. Ural
Hematology
1 shared publication
Latest Publications
- Open Access
- 21 June 2018
- Published by MDPI AG in Dentistry Journal
- Vol. 6 (3) , 22
The Effect of Immediate Obturator Reconstruction after Radical Maxillary Resections on Speech and other Functions
Objective: Maxillectomy often results in a high level of morbidity with significant psychological and functional implications for patients. The aims of the present study were to assess the effectiveness of the maxillary obturator as a speech rehabilitation aid, to examine the influence of dentition on speech intelligibility, to restore patients’ regular daily activity as soon as possible, and to maintain patients’ psychological well-being throughout the treatment. Patients and Methods: Forty-one palatomaxillary immediate obturator and definitive reconstruction patient treatments were reviewed at a clinic (Ankara, Turkey). Patients aged between 20 and 73 years with surgically acquired partial maxillary defects were included in this study. All patients were rehabilitated with immediate and definitive obturators. The patients were given immediate surgical obturators which were adjusted to the defect area with a tissue conditioner. By employing this procedure and relining with the tissue conditioner weekly, immediate obturators were used in the interim stage of the treatment. As interim obturators, prostheses were used for two to three months until healing and resorption were found satisfactory, after which the definitive obturators were fabricated. Results: The speech intelligibility test (SIT) was employed for the evaluation of the speech ability. Significant improvements were found in the mean speech intelligibility test score (SITS), from 0.02% in patients without prosthetic obturation to 94.10% in patients with immediate obturation on the second day, 95.60% in patients with immediate obturation on the 20th day, and 95.97% in patients with definitive obturation.
- 21 June 2018
- Published by MDPI AG in Dentistry Journal
- Vol. 6 (3) , 22
Open AccessThe Effect of Immediate Obturator Reconstruction after Radical Maxillary Resections on Speech and other Functions
Objective: Maxillectomy often results in a high level of morbidity with significant psychological and functional implications for patients. The aims of the present study were to assess the effectiveness of the maxillary obturator as a speech rehabilitation aid, to examine the influence of dentition on speech intelligibility, to restore patients’ regular daily activity as soon as possible, and to maintain patients’ psychological well-being throughout the treatment. Patients and Methods: Forty-one palatomaxillary immediate obturator and definitive reconstruction patient treatments were reviewed at a clinic (Ankara, Turkey). Patients aged between 20 and 73 years with surgically acquired partial maxillary defects were included in this study. All patients were rehabilitated with immediate and definitive obturators. The patients were given immediate surgical obturators which were adjusted to the defect area with a tissue conditioner. By employing this procedure and relining with the tissue conditioner weekly, immediate obturators were used in the interim stage of the treatment. As interim obturators, prostheses were used for two to three months until healing and resorption were found satisfactory, after which the definitive obturators were fabricated. Results: The speech intelligibility test (SIT) was employed for the evaluation of the speech ability. Significant improvements were found in the mean speech intelligibility test score (SITS), from 0.02% in patients without prosthetic obturation to 94.10% in patients with immediate obturation on the second day, 95.60% in patients with immediate obturation on the 20th day, and 95.97% in patients with definitive obturation.
- 31 May 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44, 12
The evaluation of implant supported bridge application at fully edentulous mandible with the use of 3D FEA
- 31 May 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44, 12
The evaluation of implant supported bridge application at fully edentulous mandible with the use of 3D FEA
- 31 May 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44, 12
An investigation on static behavior of dental implants with different loading locations and numbers of implants
- 31 May 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44, 12
An investigation on static behavior of dental implants with different loading locations and numbers of implants
- 1 May 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44, 10
An investigation on static behavior of dental implants with different loading locations and numbers of implants
- 1 May 2011
- Published by Elsevier in Journal of Biomechanics
- Vol. 44, 10
An investigation on static behavior of dental implants with different loading locations and numbers of implants
- 6 April 2009
- Published by Wiley in Journal of Prosthodontics
- Vol. 18 (3) , 217-222
Effects of Six Surface Treatment Methods on the Surface Roughness of a Low‐Fusing and an Ultra Low‐Fusing Feldspathic Ceramic Material
Purpose: The purpose of this in vitro study was to determine the effects of six surface treatment methods on the surface roughness of two feldspathic ceramic materials. Materials and Methods: One hundred twenty metal discs were cast (Remanium CS). A low‐fusing feldspathic ceramic (Vita Omega 900) was fired onto 60 metal discs, and an ultra low‐fusing feldspathic ceramic (Finesse) was fired onto the other 60 metal discs. Six surface treatment methods were selected: (1) autoglazing (AUG), (2) overglazing (OVG), (3) polishing (POL), (4) fine diamond disc grinding + polishing + autoglazing (FDPA), (5) coarse diamond disc grinding + polishing + autoglazing (CDPA), (6) polishing + autoglazing (PA). Omega specimens were assigned to six experimental groups representing six surface treatment methods (Om‐AUG, Om‐OVG, Om‐POL, Om‐FDPA, Om‐CDPA, Om‐PA) (n = 10). Finesse specimens were also assigned to six experimental groups (Fn‐AUG, Fn‐OVG, Fn‐POL, Fn‐FDPA, Fn‐CDPA, Fn‐PA) (n = 10). Treated ceramic surfaces were examined by means of profilometry and transmission electron microscopy. Results: In Omega groups mean roughness values ranged as follows: group Om‐AUG = Om‐POL > Om‐OVG > Om‐CDPA = Om‐FDPA > Om‐PA (p < 0.001). No significant difference was found between groups Om‐AUG/Om‐POL and Om‐CDPA/Om‐FDPA (p > 0.05). In Finesse groups mean roughness values ranged as follows: Fn‐CDPA > Fn‐FDPA = Fn‐AUG = Fn‐POL = Fn‐OVG > Fn‐PA (p < 0.001). No significant difference was found between Fn‐FDPA, Fn‐AUG, Fn‐ POL and Fn‐OVG (p > 0.05). Conclusions: For both ceramic types, the smoothest surfaces were obtained with polishing prior to autoglazing. Diamond disc grinding prior to polishing and autoglazing (Fn‐FDPA, Fn‐CDPA) displayed the roughest surfaces in ultra low‐fusing ceramic (Finesse). Autoglazing alone and polishing displayed the roughest surfaces in low‐fusing ceramic material (Om‐AUG, Om‐POL).
- 6 April 2009
- Published by Wiley in Journal of Prosthodontics
- Vol. 18 (3) , 217-222
Effects of Six Surface Treatment Methods on the Surface Roughness of a Low‐Fusing and an Ultra Low‐Fusing Feldspathic Ceramic Material
Purpose: The purpose of this in vitro study was to determine the effects of six surface treatment methods on the surface roughness of two feldspathic ceramic materials. Materials and Methods: One hundred twenty metal discs were cast (Remanium CS). A low‐fusing feldspathic ceramic (Vita Omega 900) was fired onto 60 metal discs, and an ultra low‐fusing feldspathic ceramic (Finesse) was fired onto the other 60 metal discs. Six surface treatment methods were selected: (1) autoglazing (AUG), (2) overglazing (OVG), (3) polishing (POL), (4) fine diamond disc grinding + polishing + autoglazing (FDPA), (5) coarse diamond disc grinding + polishing + autoglazing (CDPA), (6) polishing + autoglazing (PA). Omega specimens were assigned to six experimental groups representing six surface treatment methods (Om‐AUG, Om‐OVG, Om‐POL, Om‐FDPA, Om‐CDPA, Om‐PA) (n = 10). Finesse specimens were also assigned to six experimental groups (Fn‐AUG, Fn‐OVG, Fn‐POL, Fn‐FDPA, Fn‐CDPA, Fn‐PA) (n = 10). Treated ceramic surfaces were examined by means of profilometry and transmission electron microscopy. Results: In Omega groups mean roughness values ranged as follows: group Om‐AUG = Om‐POL > Om‐OVG > Om‐CDPA = Om‐FDPA > Om‐PA (p < 0.001). No significant difference was found between groups Om‐AUG/Om‐POL and Om‐CDPA/Om‐FDPA (p > 0.05). In Finesse groups mean roughness values ranged as follows: Fn‐CDPA > Fn‐FDPA = Fn‐AUG = Fn‐POL = Fn‐OVG > Fn‐PA (p < 0.001). No significant difference was found between Fn‐FDPA, Fn‐AUG, Fn‐ POL and Fn‐OVG (p > 0.05). Conclusions: For both ceramic types, the smoothest surfaces were obtained with polishing prior to autoglazing. Diamond disc grinding prior to polishing and autoglazing (Fn‐FDPA, Fn‐CDPA) displayed the roughest surfaces in ultra low‐fusing ceramic (Finesse). Autoglazing alone and polishing displayed the roughest surfaces in low‐fusing ceramic material (Om‐AUG, Om‐POL).
- 23 June 2005
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 32 (7) , 511-517
In vitro IL‐1β release from gingival fibroblasts in response to pure metals, dental alloys and ceramic
Little information is available on the immunological basis for side-effects of dental materials. The objective of this study is to evaluate effects of pure metals, dental alloys and ceramic on cell viability and interleukin-1 beta (IL-1beta) release in three-dimensional human gingival fibroblast cultures as an indicator of their biological performance in gingival tissues. The gingival fibroblast cultures were exposed to test specimens fabricated from nickel, iron, molybdenum, copper, indium, gold, Ni-Cr-Mo alloy (Remanium CS), Au-Pt-In alloy (Pontostar) and a dental ceramic (In-ceram). Cell viability was determined by the MTT method 24 and 48 h after exposure. Assays for IL-1beta were carried out by ELISA. Statistical analysis was performed applying the non-parametric Mann-Whitney pairwise test. Dental ceramic and gold did not influence cell viability after 24 and 48 h. Cell viability was determined after 24 and 48 h to nickel (79-77%), iron (92-90%), molybdenum (86-83%), copper (48-36%), indium (90-90%), Remanium CS (83-80%), Pontostar (94-91%) compared with control cultures. Dental ceramic, Pontostar and gold had no significant influence on IL-1beta secretion. The highest amounts of IL-1beta (10-fold) levels were determined in cell cultures exposed to copper. Indium, molybdenum and iron induced twofold IL-1beta levels compared with untreated control cultures. These results support that some metals may alter immune responses and thereby contribute to a variety of dental pathological conditions and three-dimensional cell culture models for gingival fibroblasts appear to be suitable for in vitro studies.
- 23 June 2005
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 32 (7) , 511-517
In vitro IL‐1β release from gingival fibroblasts in response to pure metals, dental alloys and ceramic
Little information is available on the immunological basis for side-effects of dental materials. The objective of this study is to evaluate effects of pure metals, dental alloys and ceramic on cell viability and interleukin-1 beta (IL-1beta) release in three-dimensional human gingival fibroblast cultures as an indicator of their biological performance in gingival tissues. The gingival fibroblast cultures were exposed to test specimens fabricated from nickel, iron, molybdenum, copper, indium, gold, Ni-Cr-Mo alloy (Remanium CS), Au-Pt-In alloy (Pontostar) and a dental ceramic (In-ceram). Cell viability was determined by the MTT method 24 and 48 h after exposure. Assays for IL-1beta were carried out by ELISA. Statistical analysis was performed applying the non-parametric Mann-Whitney pairwise test. Dental ceramic and gold did not influence cell viability after 24 and 48 h. Cell viability was determined after 24 and 48 h to nickel (79-77%), iron (92-90%), molybdenum (86-83%), copper (48-36%), indium (90-90%), Remanium CS (83-80%), Pontostar (94-91%) compared with control cultures. Dental ceramic, Pontostar and gold had no significant influence on IL-1beta secretion. The highest amounts of IL-1beta (10-fold) levels were determined in cell cultures exposed to copper. Indium, molybdenum and iron induced twofold IL-1beta levels compared with untreated control cultures. These results support that some metals may alter immune responses and thereby contribute to a variety of dental pathological conditions and three-dimensional cell culture models for gingival fibroblasts appear to be suitable for in vitro studies.
- 1 June 2003
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 12 (2) , 145-150
Barrier Membrane and Bone Graft Treatments of Dehiscence-Type Defect at Existing Implant: A Case Report
Dehiscence-type bony defects may occur after implant application because of microbial action as well as of biomechanical and occlusal overload. The aim of the treatment of a periimplant defect is to arrest the progression of the bone loss and to achieve a maintainable site for the implant. In these situations, barrier membranes and bone graft materials can be used to achieve complete bone healing around dental implants. Bone regeneration is possible in a periimplant bony defect of a functioning implant if the proper surgical technique is utilized and the etiologic cause is eradicated. This study presents the surgical coverage of a periimplant bony defect around an implant that was inserted 7 years ago. The surgical correction was made using a barrier membrane in conjunction with bone graft materials. A follow-up of 6 months seemed to reveal radiographic bone regeneration.
- 1 June 2003
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 12 (2) , 145-150
Barrier Membrane and Bone Graft Treatments of Dehiscence-Type Defect at Existing Implant: A Case Report
Dehiscence-type bony defects may occur after implant application because of microbial action as well as of biomechanical and occlusal overload. The aim of the treatment of a periimplant defect is to arrest the progression of the bone loss and to achieve a maintainable site for the implant. In these situations, barrier membranes and bone graft materials can be used to achieve complete bone healing around dental implants. Bone regeneration is possible in a periimplant bony defect of a functioning implant if the proper surgical technique is utilized and the etiologic cause is eradicated. This study presents the surgical coverage of a periimplant bony defect around an implant that was inserted 7 years ago. The surgical correction was made using a barrier membrane in conjunction with bone graft materials. A follow-up of 6 months seemed to reveal radiographic bone regeneration.
- 1 September 2002
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 11 (3) , 293-300
The Three-Dimensional Finite Element Analysis of Fixed Bridge Restoration Supported by the Combination of Teeth and Osseointegrated Implants
This study investigated the designs of osseointegrated prostheses in cases of free-end partial edentulism using comparative stress interpreted with the three-dimensional finite element method. Three free-end fixed osseointegrated prostheses models with various connection designs (i.e., rigidly connected to an abutment tooth and an implant, rigidly connected to an implant and two abutment teeth, and rigidly connected to an implant and three abutment teeth) were studied. The stress values of the three models loaded with vertical, buccolingual, and linguobuccal directions at 30 degrees angled to vertical axis forces were analyzed. When the fixed partial denture was connected to the three natural abutment teeth and an implant, the lowest levels of stress in the bone were noted.
- 1 September 2002
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 11 (3) , 293-300
The Three-Dimensional Finite Element Analysis of Fixed Bridge Restoration Supported by the Combination of Teeth and Osseointegrated Implants
This study investigated the designs of osseointegrated prostheses in cases of free-end partial edentulism using comparative stress interpreted with the three-dimensional finite element method. Three free-end fixed osseointegrated prostheses models with various connection designs (i.e., rigidly connected to an abutment tooth and an implant, rigidly connected to an implant and two abutment teeth, and rigidly connected to an implant and three abutment teeth) were studied. The stress values of the three models loaded with vertical, buccolingual, and linguobuccal directions at 30 degrees angled to vertical axis forces were analyzed. When the fixed partial denture was connected to the three natural abutment teeth and an implant, the lowest levels of stress in the bone were noted.