Dominik Kraus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dominik Kraus has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Norbert Enkling
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland
12 shared publications - Milan Stoilov
Department of Prosthodontics, Preclinical Education and Dental Materials Science, University of Bonn, 53111 Bonn, Germany
11 shared publications - Helmut Stark
Department of Prosthodontics, Preclinical Education and Dental Materials Science, University Hospital Bonn, 53111 Bonn, Germany
8 shared publications - Michael Marder
Department of Prosthodontics, Preclinical Education and Dental Materials Science, University Hospital Bonn, 53111 Bonn, Germany
8 shared publications - Jochen Winter
Oral Cell Biology Group, Department of Periodontology, Operative and Preventive Dentistry, University Hospital, Medical Faculty, University of Bonn, Welschnonnenstr. 17, 53111 Bonn, Germany
6 shared publications - Lea Stoilov
Department of Prosthodontics, Preclinical Education and Dental Materials Science, University Hospital Bonn, 53111 Bonn, Germany
6 shared publications
Latest Publications
- Open Access
- 3 October 2026
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 153
Repair of direct restorative materials with a self-adhesive composite hybrid: Effects of substrate, surface pretreatment, and aging
- 3 October 2026
- Published by Elsevier in International Journal of Adhesion and Adhesives
- Vol. 153
Open AccessRepair of direct restorative materials with a self-adhesive composite hybrid: Effects of substrate, surface pretreatment, and aging
- Open Access
Chairside Repair of Provisional Restorative Materials: Effects of Material Type, Repair Protocol, and Thermocycling on Shear Bond Strength
(1) Background: Repairing fractured provisional restorations may avoid refabrication, but success depends on substrate chemistry, repair protocol, and aging. This study evaluated shear bond strength (SBS) and failure behavior after chairside repair of PEMA-, PMMA-, and bis-acryl-based provisional materials. (2) Methods: In total, 380 specimens were prepared. Repairs used the substrate material, a dedicated repair system, or flowable composite without pretreatment or after a methacrylate repair primer, an MMA/Bis-GMA primer, or a multifunctional methacrylate coating. Half underwent 5000 thermocycles (5–55 °C). SBS was determined using a notched-edge test based on ISO 29022:2013, and failure modes were evaluated. An HC3-robust three-factor model was followed by Holm-adjusted Welch comparisons. (3) Results: A material × protocol × aging interaction occurred (p < 0.001). Homologous repair yielded 17.88–20.35 MPa for PEMA and 25.09–25.30 MPa for PMMA. Pretreatment improved composite repair across substrates. Pre-test failures affected 40.0% of PEMA and 13.3% of PMMA specimens but no bis-acryl specimens. Unprimed flowable composite produced complete pre-test failure with PEMA, low SBS with PMMA, and moderate SBS with bis-acryl. Thermocycling effects were protocol-dependent. (4) Conclusions: Conventional acrylics should be repaired homologously or after chemical conditioning, whereas flowable composite alone may be suitable for minor, non-load-bearing bis-acryl corrections.
Open AccessChairside Repair of Provisional Restorative Materials: Effects of Material Type, Repair Protocol, and Thermocycling on Shear Bond Strength
(1) Background: Repairing fractured provisional restorations may avoid refabrication, but success depends on substrate chemistry, repair protocol, and aging. This study evaluated shear bond strength (SBS) and failure behavior after chairside repair of PEMA-, PMMA-, and bis-acryl-based provisional materials. (2) Methods: In total, 380 specimens were prepared. Repairs used the substrate material, a dedicated repair system, or flowable composite without pretreatment or after a methacrylate repair primer, an MMA/Bis-GMA primer, or a multifunctional methacrylate coating. Half underwent 5000 thermocycles (5–55 °C). SBS was determined using a notched-edge test based on ISO 29022:2013, and failure modes were evaluated. An HC3-robust three-factor model was followed by Holm-adjusted Welch comparisons. (3) Results: A material × protocol × aging interaction occurred (p < 0.001). Homologous repair yielded 17.88–20.35 MPa for PEMA and 25.09–25.30 MPa for PMMA. Pretreatment improved composite repair across substrates. Pre-test failures affected 40.0% of PEMA and 13.3% of PMMA specimens but no bis-acryl specimens. Unprimed flowable composite produced complete pre-test failure with PEMA, low SBS with PMMA, and moderate SBS with bis-acryl. Thermocycling effects were protocol-dependent. (4) Conclusions: Conventional acrylics should be repaired homologously or after chemical conditioning, whereas flowable composite alone may be suitable for minor, non-load-bearing bis-acryl corrections.
- Open Access
- 1 September 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (9) , 545
Prosthesis Survival, Complications, and Maintenance of Telescopic-Crown-Retained Removable Dental Prostheses and Root-Cap-Retained Overdentures: A Retrospective Cohort Study
Objectives: To compare prosthesis survival, complication-free survival, and maintenance-free survival between telescopic-crown-retained dentures (TCDs) and root-cap-retained overdentures with ball attachments (RCDs), and to evaluate associated clinical factors. Methods: This retrospective single-center cohort study included 654 unique patients, each contributing one eligible prosthesis (406 TCDs and 248 RCDs). Mean follow-up was 4.15 years for TCD and 2.75 years for RCD. Time-to-event outcomes were analyzed using Kaplan–Meier methods and multivariable Cox regression. Adjusted analyses were restricted to prostheses supported by one to three abutments. Results: Unadjusted prosthesis survival was higher for TCD (p = 0.0001), whereas prosthesis type was not clearly associated with loss after adjustment (RCD vs. TCD: HR = 1.28; 95% CI: 0.75–2.19). Single-abutment support and, in sensitivity analysis, point-like support were associated with higher loss hazards. The higher adjusted complication hazard for RCD was attenuated in sensitivity analysis. RCDs were consistently associated with earlier maintenance (average HR = 1.75; 95% CI: 1.43–2.13), with exploratory analyses suggesting a greater difference during early follow-up and among single-abutment prostheses. Conclusions: The support situation appears more relevant to prosthesis loss than the retention concept alone. RCDs show earlier first documented maintenance requirements, whereas evidence for an independent difference in complication risk is model-dependent.
- 1 September 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (9) , 545
Open AccessProsthesis Survival, Complications, and Maintenance of Telescopic-Crown-Retained Removable Dental Prostheses and Root-Cap-Retained Overdentures: A Retrospective Cohort Study
Objectives: To compare prosthesis survival, complication-free survival, and maintenance-free survival between telescopic-crown-retained dentures (TCDs) and root-cap-retained overdentures with ball attachments (RCDs), and to evaluate associated clinical factors. Methods: This retrospective single-center cohort study included 654 unique patients, each contributing one eligible prosthesis (406 TCDs and 248 RCDs). Mean follow-up was 4.15 years for TCD and 2.75 years for RCD. Time-to-event outcomes were analyzed using Kaplan–Meier methods and multivariable Cox regression. Adjusted analyses were restricted to prostheses supported by one to three abutments. Results: Unadjusted prosthesis survival was higher for TCD (p = 0.0001), whereas prosthesis type was not clearly associated with loss after adjustment (RCD vs. TCD: HR = 1.28; 95% CI: 0.75–2.19). Single-abutment support and, in sensitivity analysis, point-like support were associated with higher loss hazards. The higher adjusted complication hazard for RCD was attenuated in sensitivity analysis. RCDs were consistently associated with earlier maintenance (average HR = 1.75; 95% CI: 1.43–2.13), with exploratory analyses suggesting a greater difference during early follow-up and among single-abutment prostheses. Conclusions: The support situation appears more relevant to prosthesis loss than the retention concept alone. RCDs show earlier first documented maintenance requirements, whereas evidence for an independent difference in complication risk is model-dependent.
- Open Access
- 9 July 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (7) , 332
Implants in Adolescents: Clinical Outcomes After Growth-Pattern-Adapted Implant Placement
(1) Background: Dental implants in adolescents remain controversial. This retrospective study aimed to evaluate the esthetic outcome of implants placed during adolescence using a growth-pattern-adapted concept, with implant survival, peri-implant health, and patient satisfaction as secondary outcomes. (2) Materials and methods: Primary implant survival was retrospectively evaluated based on treatment records in 305 patients (612 implants) affected by tooth loss or congenital tooth agenesis. A subgroup of 68 anterior maxillary implants (50 patients, mean age at implantation: 16.2 ± 2.3 years; range: 12–20) were clinically re-examined after a mean follow-up of 92.4 ± 61.2 months (range: 36–288). (3) Results: Primary implant survival was 93.8% overall (tooth loss: 97.7%; tooth agenesis: 92.3%). The clinical follow-up cohort showed no cases of peri-implantitis and patient satisfaction was high. Anterior maxillary implants demonstrated favorable esthetic outcomes (Pink Esthetic Score [PES]: 12.0 ± 1.1), with females exhibiting significantly higher scores than males. Vertical discrepancies between the implant crown and the contralateral tooth were observed in 41.2% of implants (infraocclusion: 32.4%; supraocclusion: 8.8%). They were significantly associated with tooth loss, non-mesofacial growth patterns and younger age at implantation, without significant influence on PES. (4) Conclusions: The growth-pattern-adapted implant placement met the predefined esthetic threshold and resulted in high primary implant survival, stable peri-implant health, and high satisfaction, supporting its feasibility for anterior maxillary implant placement during adolescence.
- 9 July 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (7) , 332
Open AccessImplants in Adolescents: Clinical Outcomes After Growth-Pattern-Adapted Implant Placement
(1) Background: Dental implants in adolescents remain controversial. This retrospective study aimed to evaluate the esthetic outcome of implants placed during adolescence using a growth-pattern-adapted concept, with implant survival, peri-implant health, and patient satisfaction as secondary outcomes. (2) Materials and methods: Primary implant survival was retrospectively evaluated based on treatment records in 305 patients (612 implants) affected by tooth loss or congenital tooth agenesis. A subgroup of 68 anterior maxillary implants (50 patients, mean age at implantation: 16.2 ± 2.3 years; range: 12–20) were clinically re-examined after a mean follow-up of 92.4 ± 61.2 months (range: 36–288). (3) Results: Primary implant survival was 93.8% overall (tooth loss: 97.7%; tooth agenesis: 92.3%). The clinical follow-up cohort showed no cases of peri-implantitis and patient satisfaction was high. Anterior maxillary implants demonstrated favorable esthetic outcomes (Pink Esthetic Score [PES]: 12.0 ± 1.1), with females exhibiting significantly higher scores than males. Vertical discrepancies between the implant crown and the contralateral tooth were observed in 41.2% of implants (infraocclusion: 32.4%; supraocclusion: 8.8%). They were significantly associated with tooth loss, non-mesofacial growth patterns and younger age at implantation, without significant influence on PES. (4) Conclusions: The growth-pattern-adapted implant placement met the predefined esthetic threshold and resulted in high primary implant survival, stable peri-implant health, and high satisfaction, supporting its feasibility for anterior maxillary implant placement during adolescence.
- Open Access
- 21 January 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (1) , 55
Differential Expression of S100A Genes in hDPSCs Following Stimulation with Two Hydraulic Calcium Silicate Cements: A Laboratory Investigation
Hydraulic calcium silicate cements (HCSCs) are contemporary materials in vital pulp therapy (VPT) and regenerative endodontic therapy (RET) due to their favorable effects on pulpal and periodontal cells, including cell differentiation and hard tissue formation. Recent studies also indicated the involvement of several S100A proteins in inflammatory, differentiation, and mineralization processes of the pulp. The aim of the present study was to investigate the effects of HCSCs on S100A gene expression in human dental pulp stem cells (hDPSCs). Human DPSCs were isolated and characterized by multi-lineage stem-cell markers and differentiation protocols. In stimulation experiments hDPSCs were exposed to ProRoot®MTA, Biodentine®, IL-1β, and dexamethasone. Cell viability was determined by XTT assay. IL-6 and IL-8 mRNA expression was measured to analyze proinflammatory response. In addition, odontogenic differentiation and biomineralization assays were conducted (DSPP- and ALP-mRNA expression, ALP activity, and Alizarin Red staining). Differential expression of 13 S100A genes was examined using qPCR. Low concentrations of HCSCs enhanced the proliferation of hDPSCs, whereas higher concentrations exhibited cytotoxic effects. HCSCs induced a pro-inflammatory response and led to odontogenic differentiation and biomineralization. This was accompanied by significant alterations in the expression levels of various S100A genes. ProRoot®MTA and Biodentine® significantly affect the expression of several S100A genes in hDPSCs, supporting their role in inflammation, differentiation, and mineralization. These findings indicate a link between the effects of HCSCs on human pulp cells during VPT or RET and S100A proteins.
- 21 January 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (1) , 55
Open AccessDifferential Expression of S100A Genes in hDPSCs Following Stimulation with Two Hydraulic Calcium Silicate Cements: A Laboratory Investigation
Hydraulic calcium silicate cements (HCSCs) are contemporary materials in vital pulp therapy (VPT) and regenerative endodontic therapy (RET) due to their favorable effects on pulpal and periodontal cells, including cell differentiation and hard tissue formation. Recent studies also indicated the involvement of several S100A proteins in inflammatory, differentiation, and mineralization processes of the pulp. The aim of the present study was to investigate the effects of HCSCs on S100A gene expression in human dental pulp stem cells (hDPSCs). Human DPSCs were isolated and characterized by multi-lineage stem-cell markers and differentiation protocols. In stimulation experiments hDPSCs were exposed to ProRoot®MTA, Biodentine®, IL-1β, and dexamethasone. Cell viability was determined by XTT assay. IL-6 and IL-8 mRNA expression was measured to analyze proinflammatory response. In addition, odontogenic differentiation and biomineralization assays were conducted (DSPP- and ALP-mRNA expression, ALP activity, and Alizarin Red staining). Differential expression of 13 S100A genes was examined using qPCR. Low concentrations of HCSCs enhanced the proliferation of hDPSCs, whereas higher concentrations exhibited cytotoxic effects. HCSCs induced a pro-inflammatory response and led to odontogenic differentiation and biomineralization. This was accompanied by significant alterations in the expression levels of various S100A genes. ProRoot®MTA and Biodentine® significantly affect the expression of several S100A genes in hDPSCs, supporting their role in inflammation, differentiation, and mineralization. These findings indicate a link between the effects of HCSCs on human pulp cells during VPT or RET and S100A proteins.
- Open Access
- 16 August 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (8) , 296
Influence of Drilling Protocol on Primary Implant Stability Depending on Different Bone Qualities and Implant Macro-Designs, Lengths, and Diameters
Background: Primary implant stability is a critical factor for successful osseointegration and long-term implant success. This study investigates the impact of drilling protocol modifications on primary stability, considering different bone qualities and implant macro-designs, lengths, and diameters. Material and Methods: Three implant designs—two parallel-walled and one tapered—were tested with diameters ranging from 3.4 to 5.2 mm and lengths from 7.5 to 14.5 mm. Implants were placed in polyurethane foam blocks simulating different bone densities (10, 15, 25, and 35 PCF). A standard drilling protocol was used in all groups, with modifications based on bone quality: overpreparation in dense bone and underpreparation in softer bone. Primary stability was evaluated using insertion torque (IT). The optimal IT range was defined as 25–50 Ncm, based on clinical guidelines for immediate loading. The influence of drilling protocol adaptations on stability parameters was assessed. Results: Insertion torque was primarily influenced by bone density and implant diameter, with implant length playing a minor role. In dense bone (D1, D2), underpreparation improved torque values, especially in smaller implants, while overpreparation reduced them. The highest torques occurred with 5.2 mm implants, sometimes exceeding 80 Ncm. Standard protocols did not consistently achieve optimal torque across implant types. In soft bone (D3), underpreparation—particularly with tapered implants—was modestly beneficial. In very soft bone (D4), none of the protocols reliably reached the desired torque range. Conclusions: Adapting drilling protocols to bone density improves insertion torque, especially with wider implants and in denser bone. Underpreparation is generally more effective than overpreparation. However, in very soft bone, neither implant geometry nor drilling adaptations reliably achieve optimal primary stability, highlighting the need for additional strategies.
- 16 August 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (8) , 296
Open AccessInfluence of Drilling Protocol on Primary Implant Stability Depending on Different Bone Qualities and Implant Macro-Designs, Lengths, and Diameters
Background: Primary implant stability is a critical factor for successful osseointegration and long-term implant success. This study investigates the impact of drilling protocol modifications on primary stability, considering different bone qualities and implant macro-designs, lengths, and diameters. Material and Methods: Three implant designs—two parallel-walled and one tapered—were tested with diameters ranging from 3.4 to 5.2 mm and lengths from 7.5 to 14.5 mm. Implants were placed in polyurethane foam blocks simulating different bone densities (10, 15, 25, and 35 PCF). A standard drilling protocol was used in all groups, with modifications based on bone quality: overpreparation in dense bone and underpreparation in softer bone. Primary stability was evaluated using insertion torque (IT). The optimal IT range was defined as 25–50 Ncm, based on clinical guidelines for immediate loading. The influence of drilling protocol adaptations on stability parameters was assessed. Results: Insertion torque was primarily influenced by bone density and implant diameter, with implant length playing a minor role. In dense bone (D1, D2), underpreparation improved torque values, especially in smaller implants, while overpreparation reduced them. The highest torques occurred with 5.2 mm implants, sometimes exceeding 80 Ncm. Standard protocols did not consistently achieve optimal torque across implant types. In soft bone (D3), underpreparation—particularly with tapered implants—was modestly beneficial. In very soft bone (D4), none of the protocols reliably reached the desired torque range. Conclusions: Adapting drilling protocols to bone density improves insertion torque, especially with wider implants and in denser bone. Underpreparation is generally more effective than overpreparation. However, in very soft bone, neither implant geometry nor drilling adaptations reliably achieve optimal primary stability, highlighting the need for additional strategies.
- Open Access
- 8 March 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (3) , 93
Intraoperative Profiling of the Supracrestal Implant Complex Minimizes Peri-Implant Crestal Bone Remodeling: The Guided Bone Profiling Concept
(1) Background: Early-stage bone resorption following implant placement can significantly impact the long-term success of implants. This study evaluates whether a fully digitally planned implant position based on the E-point concept, along with guided profiling of the supracrestal complex, contributes to improved stability of peri-implant bone levels. (2) Methods: 29 implants were placed in 27 patients utilizing both immediate (Group 1; n = 19) and delayed placement (Group 2; n = 10) protocols. Implant position and emergence profile were preoperatively determined and consistently executed through guided surgery and CAD/CAM-fabricated restorations. Due to the subcrestal positioning of the implant, a corresponding bone profiler with a guide pin was used to shape the emergence profile and prevent the provisional restoration from impinging on the proximal bone. Provisional restorations were immediately placed to support the emergence profile. Bone level changes were documented radiographically over a two-year period. The first Bone-to-Implant Contact Level (∆ fBIC), change in highest approximal Bone Level (∆ haBL), and formation of an emergence profile width (WEP) were measured. (3) Results: All implants and restorations survived after two years, no significant change in first Bone-to-Implant Contact Level (∆ fBIC = 0 ± 0.02 mm), no change in highest approximal Bone Level (∆ haBL) of −0.23 mm ± 0.71 mm, and formation of an emergence profile width (WEP) averaging 0.18 ± 0.19 mm. (4) Conclusions: Despite the initial stress on the bone caused by bone profiling, guided implant placement and bone shaping, supported by an immediate provisional, have a positive effect on peri-implant bone stability.
- 8 March 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (3) , 93
Open AccessIntraoperative Profiling of the Supracrestal Implant Complex Minimizes Peri-Implant Crestal Bone Remodeling: The Guided Bone Profiling Concept
(1) Background: Early-stage bone resorption following implant placement can significantly impact the long-term success of implants. This study evaluates whether a fully digitally planned implant position based on the E-point concept, along with guided profiling of the supracrestal complex, contributes to improved stability of peri-implant bone levels. (2) Methods: 29 implants were placed in 27 patients utilizing both immediate (Group 1; n = 19) and delayed placement (Group 2; n = 10) protocols. Implant position and emergence profile were preoperatively determined and consistently executed through guided surgery and CAD/CAM-fabricated restorations. Due to the subcrestal positioning of the implant, a corresponding bone profiler with a guide pin was used to shape the emergence profile and prevent the provisional restoration from impinging on the proximal bone. Provisional restorations were immediately placed to support the emergence profile. Bone level changes were documented radiographically over a two-year period. The first Bone-to-Implant Contact Level (∆ fBIC), change in highest approximal Bone Level (∆ haBL), and formation of an emergence profile width (WEP) were measured. (3) Results: All implants and restorations survived after two years, no significant change in first Bone-to-Implant Contact Level (∆ fBIC = 0 ± 0.02 mm), no change in highest approximal Bone Level (∆ haBL) of −0.23 mm ± 0.71 mm, and formation of an emergence profile width (WEP) averaging 0.18 ± 0.19 mm. (4) Conclusions: Despite the initial stress on the bone caused by bone profiling, guided implant placement and bone shaping, supported by an immediate provisional, have a positive effect on peri-implant bone stability.
- Open Access
- 11 September 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (5) , 1118-1132
Survival of Chairside Posterior Single Crowns Made from InCoris TZI Zirconia—A Retrospective Analysis up to 10 Years
Objective: The aim of the present study was to evaluate the long-term clinical survival and success of chairside-fabricated single-tooth monolithic zirconia restorations on posterior teeth using the speed sintering process. Materials and Methods: Between 2012 and 2022, 250 single-tooth crowns were fabricated for 193 patients using the CEREC® chairside workflow. Restorations were fabricated from monolithic 3Y-TZP zirconia (InCoris TZI, Dentsply Sirona©, Bensheim, Germany) as full-contour crowns. The same clinician performed all procedures. Luting was performed using self-adhesive resin-based cements or glass ionomer cement. Retrospective analysis was conducted, defining survival as crowns still in function regardless of any interventions, and success as crowns that remained functional without the need for intervention. Statistical analysis was performed using Kaplan–Meier analysis, considering “refabrication” and “intervention” as endpoints. Results: Of the 250 crowns, a total of 162 (64.8%) crowns showed success. Over the whole observation period, 44 crowns (17.6%) required refabrication, and 88 (35.2%) required intervention. Mean survival without refabrication was 7.43 years, with a 5- and 7.5-year survival of 86.9% and 76.6%. The mean survival without intervention was 6.5 years, with a 5- and 7.5-year survival of 70.8% and 59.9%. Conclusions: Under appropriate technical conditions, chairside-fabricated 3Y-TZP zirconia single-tooth crowns represent a viable fabrication method. Neither the cementation mode nor the crown position—whether on premolars or molars—significantly impacted the survival rates.
- 11 September 2024
- Published by MDPI AG in Prosthesis
- Vol. 6 (5) , 1118-1132
Open AccessSurvival of Chairside Posterior Single Crowns Made from InCoris TZI Zirconia—A Retrospective Analysis up to 10 Years
Objective: The aim of the present study was to evaluate the long-term clinical survival and success of chairside-fabricated single-tooth monolithic zirconia restorations on posterior teeth using the speed sintering process. Materials and Methods: Between 2012 and 2022, 250 single-tooth crowns were fabricated for 193 patients using the CEREC® chairside workflow. Restorations were fabricated from monolithic 3Y-TZP zirconia (InCoris TZI, Dentsply Sirona©, Bensheim, Germany) as full-contour crowns. The same clinician performed all procedures. Luting was performed using self-adhesive resin-based cements or glass ionomer cement. Retrospective analysis was conducted, defining survival as crowns still in function regardless of any interventions, and success as crowns that remained functional without the need for intervention. Statistical analysis was performed using Kaplan–Meier analysis, considering “refabrication” and “intervention” as endpoints. Results: Of the 250 crowns, a total of 162 (64.8%) crowns showed success. Over the whole observation period, 44 crowns (17.6%) required refabrication, and 88 (35.2%) required intervention. Mean survival without refabrication was 7.43 years, with a 5- and 7.5-year survival of 86.9% and 76.6%. The mean survival without intervention was 6.5 years, with a 5- and 7.5-year survival of 70.8% and 59.9%. Conclusions: Under appropriate technical conditions, chairside-fabricated 3Y-TZP zirconia single-tooth crowns represent a viable fabrication method. Neither the cementation mode nor the crown position—whether on premolars or molars—significantly impacted the survival rates.
- Open Access
- 14 August 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (8) , 259
Efficacy of Virtual Preparation Simulators Compared to Traditional Preparations on Phantom Heads
Background: Virtual simulators are increasingly being introduced in dental education. This study investigates whether virtual simulators offer comparable or superior educational efficacy when compared to traditional phantom simulators. Materials and Methods: Participants were randomly allocated into groups: Virtual Preparation (SIM; n = 30) and Traditional Preparation (FRA; n = 30). Students were tasked with preparing tooth 36 for a full-cast crown during free practice for four days. Faculty staff provided feedback to both groups. Examinations were administered and graded by three examiners (preclinical and clinical consultants and a dental surgery consultant). Additionally, a survey was conducted to assess each training concept. Results: The FRA group achieved significantly better grades in the preparation exam evaluations by all three examiners, compared to the SIM group. Interrater reliability showed only moderate agreement, with the clinical examiner giving better grades than the other two. The questionnaire results indicate that while participants managed with the virtual system, they preferred the analog system for exams and patient preparation. Conclusion: Virtual simulators do not seem to be as good when it comes to practicing for a preparation exam or clinical preparation, especially for unexperienced students. However, they still appear to be useful as an additional tool for introducing students to the topic of preparation.
- 14 August 2024
- Published by MDPI AG in Dentistry Journal
- Vol. 12 (8) , 259
Open AccessEfficacy of Virtual Preparation Simulators Compared to Traditional Preparations on Phantom Heads
Background: Virtual simulators are increasingly being introduced in dental education. This study investigates whether virtual simulators offer comparable or superior educational efficacy when compared to traditional phantom simulators. Materials and Methods: Participants were randomly allocated into groups: Virtual Preparation (SIM; n = 30) and Traditional Preparation (FRA; n = 30). Students were tasked with preparing tooth 36 for a full-cast crown during free practice for four days. Faculty staff provided feedback to both groups. Examinations were administered and graded by three examiners (preclinical and clinical consultants and a dental surgery consultant). Additionally, a survey was conducted to assess each training concept. Results: The FRA group achieved significantly better grades in the preparation exam evaluations by all three examiners, compared to the SIM group. Interrater reliability showed only moderate agreement, with the clinical examiner giving better grades than the other two. The questionnaire results indicate that while participants managed with the virtual system, they preferred the analog system for exams and patient preparation. Conclusion: Virtual simulators do not seem to be as good when it comes to practicing for a preparation exam or clinical preparation, especially for unexperienced students. However, they still appear to be useful as an additional tool for introducing students to the topic of preparation.
- Open Access
- 19 February 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (4) , 1165
Influence of Cementation Mode and Ferrule Design on the Fatigue Resistance of Monolithic Zirconia Endocrowns
Background: Classic endocrowns made of dental ceramics are considered a promising alternative to traditional post-endodontic restorations. The use of circular ferrules in endocrowns is a topic of controversial discussion. Therefore, the present study aims to evaluate the effect of ferrule design and cementation mode on the fatigue resistance of zirconia endocrowns. Methods: Eighty human molars were divided into four groups (n = 20): NFC (no-ferrule, conventional cementation), NFA (no-ferrule, adhesive luting), FC (ferrule, conventional cementation) and FA (ferrule, adhesive luting). Both the classic and the modified endocrown preparation with a two-millimeter ferrule design were carried out. Endocrowns were fabricated from zirconia using the CEREC system. After thermocycling, specimens were loaded according to the step-stress test up to 1500 N. Results: Failure rate was low; 88.8% of total specimens passed the step-stress test. Fractures were distributed between all groups; no significant differences in fatigue resistance were detected for preparation design and cementation mode. Conclusions: Endocrowns appear to be a promising concept for endodontically treated molars. Ferrule and also cementation mode have only a minor influence on fatigue resistance of zirconia endocrowns. However, at very high forces, the marginal area of the ferrule represents a weak point.
- 19 February 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (4) , 1165
Open AccessInfluence of Cementation Mode and Ferrule Design on the Fatigue Resistance of Monolithic Zirconia Endocrowns
Background: Classic endocrowns made of dental ceramics are considered a promising alternative to traditional post-endodontic restorations. The use of circular ferrules in endocrowns is a topic of controversial discussion. Therefore, the present study aims to evaluate the effect of ferrule design and cementation mode on the fatigue resistance of zirconia endocrowns. Methods: Eighty human molars were divided into four groups (n = 20): NFC (no-ferrule, conventional cementation), NFA (no-ferrule, adhesive luting), FC (ferrule, conventional cementation) and FA (ferrule, adhesive luting). Both the classic and the modified endocrown preparation with a two-millimeter ferrule design were carried out. Endocrowns were fabricated from zirconia using the CEREC system. After thermocycling, specimens were loaded according to the step-stress test up to 1500 N. Results: Failure rate was low; 88.8% of total specimens passed the step-stress test. Fractures were distributed between all groups; no significant differences in fatigue resistance were detected for preparation design and cementation mode. Conclusions: Endocrowns appear to be a promising concept for endodontically treated molars. Ferrule and also cementation mode have only a minor influence on fatigue resistance of zirconia endocrowns. However, at very high forces, the marginal area of the ferrule represents a weak point.