MMMichael Marder

Michael Marder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael Marder has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Norbert Enkling

    Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland

    11 shared publications
  • Dominik Kraus

    Department of Prosthodontics, Preclinical Education and Material Sciences, University Hospital, Faculty of Medicine, University of Bonn, Welschnonnenstr. 17, 53111 Bonn, Germany

    8 shared publications
  • Milan Stoilov

    Department of Prosthodontics, Preclinical Education and Dental Materials Science, University of Bonn, 53111 Bonn, Germany

    8 shared publications
  • Helmut Stark

    Department of Prosthodontics, Preclinical Education and Dental Materials Science, University Hospital Bonn, 53111 Bonn, Germany

    5 shared publications
  • Lea Stoilov

    Department of Prosthodontics, Preclinical Education and Dental Materials Science, University Hospital Bonn, 53111 Bonn, Germany

    4 shared publications
  • Dominik Kraus

    Department of Prosthodontics, Preclinical Education and Dental Material Science University Hospital Bonn Bonn Germany

    3 shared publications

Latest Publications

  • Open Access

    Chairside Repair of Provisional Restorative Materials: Effects of Material Type, Repair Protocol, and Thermocycling on Shear Bond Strength

    by Milan Stoilov, Rebecca Maria Krüger, Michael Marder, Helmut Stark, Norbert Enkling, Dominik Kraus

    (1) Background: Repairing fractured provisional restorations may avoid refabrication, but success depends on substrate chemistry, repair protocol, and aging. This study evaluated shear bond strength (SBS) and failure behavior after chairside repair of PEMA-, PMMA-, and bis-acryl-based provisional materials. (2) Methods: In total, 380 specimens were prepared. Repairs used the substrate material, a dedicated repair system, or flowable composite without pretreatment or after a methacrylate repair primer, an MMA/Bis-GMA primer, or a multifunctional methacrylate coating. Half underwent 5000 thermocycles (5–55 °C). SBS was determined using a notched-edge test based on ISO 29022:2013, and failure modes were evaluated. An HC3-robust three-factor model was followed by Holm-adjusted Welch comparisons. (3) Results: A material × protocol × aging interaction occurred (p < 0.001). Homologous repair yielded 17.88–20.35 MPa for PEMA and 25.09–25.30 MPa for PMMA. Pretreatment improved composite repair across substrates. Pre-test failures affected 40.0% of PEMA and 13.3% of PMMA specimens but no bis-acryl specimens. Unprimed flowable composite produced complete pre-test failure with PEMA, low SBS with PMMA, and moderate SBS with bis-acryl. Thermocycling effects were protocol-dependent. (4) Conclusions: Conventional acrylics should be repaired homologously or after chemical conditioning, whereas flowable composite alone may be suitable for minor, non-load-bearing bis-acryl corrections.

  • Open Access

    Prosthesis Survival, Complications, and Maintenance of Telescopic-Crown-Retained Removable Dental Prostheses and Root-Cap-Retained Overdentures: A Retrospective Cohort Study

    by Anastasia Timoschenko, Lea Stoilov, Michael Marder, Helmut Stark, Norbert Enkling, Dominik Kraus, Milan Stoilov

    Objectives: To compare prosthesis survival, complication-free survival, and maintenance-free survival between telescopic-crown-retained dentures (TCDs) and root-cap-retained overdentures with ball attachments (RCDs), and to evaluate associated clinical factors. Methods: This retrospective single-center cohort study included 654 unique patients, each contributing one eligible prosthesis (406 TCDs and 248 RCDs). Mean follow-up was 4.15 years for TCD and 2.75 years for RCD. Time-to-event outcomes were analyzed using Kaplan–Meier methods and multivariable Cox regression. Adjusted analyses were restricted to prostheses supported by one to three abutments. Results: Unadjusted prosthesis survival was higher for TCD (p = 0.0001), whereas prosthesis type was not clearly associated with loss after adjustment (RCD vs. TCD: HR = 1.28; 95% CI: 0.75–2.19). Single-abutment support and, in sensitivity analysis, point-like support were associated with higher loss hazards. The higher adjusted complication hazard for RCD was attenuated in sensitivity analysis. RCDs were consistently associated with earlier maintenance (average HR = 1.75; 95% CI: 1.43–2.13), with exploratory analyses suggesting a greater difference during early follow-up and among single-abutment prostheses. Conclusions: The support situation appears more relevant to prosthesis loss than the retention concept alone. RCDs show earlier first documented maintenance requirements, whereas evidence for an independent difference in complication risk is model-dependent.

  • Open Access

    Implants in Adolescents: Clinical Outcomes After Growth-Pattern-Adapted Implant Placement

    by Felix Tetsch, Milan Stoilov, Dominik Kraus, Michael Marder, Jan Tetsch, Norbert Enkling

    (1) Background: Dental implants in adolescents remain controversial. This retrospective study aimed to evaluate the esthetic outcome of implants placed during adolescence using a growth-pattern-adapted concept, with implant survival, peri-implant health, and patient satisfaction as secondary outcomes. (2) Materials and methods: Primary implant survival was retrospectively evaluated based on treatment records in 305 patients (612 implants) affected by tooth loss or congenital tooth agenesis. A subgroup of 68 anterior maxillary implants (50 patients, mean age at implantation: 16.2 ± 2.3 years; range: 12–20) were clinically re-examined after a mean follow-up of 92.4 ± 61.2 months (range: 36–288). (3) Results: Primary implant survival was 93.8% overall (tooth loss: 97.7%; tooth agenesis: 92.3%). The clinical follow-up cohort showed no cases of peri-implantitis and patient satisfaction was high. Anterior maxillary implants demonstrated favorable esthetic outcomes (Pink Esthetic Score [PES]: 12.0 ± 1.1), with females exhibiting significantly higher scores than males. Vertical discrepancies between the implant crown and the contralateral tooth were observed in 41.2% of implants (infraocclusion: 32.4%; supraocclusion: 8.8%). They were significantly associated with tooth loss, non-mesofacial growth patterns and younger age at implantation, without significant influence on PES. (4) Conclusions: The growth-pattern-adapted implant placement met the predefined esthetic threshold and resulted in high primary implant survival, stable peri-implant health, and high satisfaction, supporting its feasibility for anterior maxillary implant placement during adolescence.

  • Open Access

    Influence of Drilling Protocol on Primary Implant Stability Depending on Different Bone Qualities and Implant Macro-Designs, Lengths, and Diameters

    by Milan Stoilov, Ramin Shafaghi, Lea Stoilov, Helmut Stark, Michael Marder, Norbert Enkling, Dominik Kraus

    Background: Primary implant stability is a critical factor for successful osseointegration and long-term implant success. This study investigates the impact of drilling protocol modifications on primary stability, considering different bone qualities and implant macro-designs, lengths, and diameters. Material and Methods: Three implant designs—two parallel-walled and one tapered—were tested with diameters ranging from 3.4 to 5.2 mm and lengths from 7.5 to 14.5 mm. Implants were placed in polyurethane foam blocks simulating different bone densities (10, 15, 25, and 35 PCF). A standard drilling protocol was used in all groups, with modifications based on bone quality: overpreparation in dense bone and underpreparation in softer bone. Primary stability was evaluated using insertion torque (IT). The optimal IT range was defined as 25–50 Ncm, based on clinical guidelines for immediate loading. The influence of drilling protocol adaptations on stability parameters was assessed. Results: Insertion torque was primarily influenced by bone density and implant diameter, with implant length playing a minor role. In dense bone (D1, D2), underpreparation improved torque values, especially in smaller implants, while overpreparation reduced them. The highest torques occurred with 5.2 mm implants, sometimes exceeding 80 Ncm. Standard protocols did not consistently achieve optimal torque across implant types. In soft bone (D3), underpreparation—particularly with tapered implants—was modestly beneficial. In very soft bone (D4), none of the protocols reliably reached the desired torque range. Conclusions: Adapting drilling protocols to bone density improves insertion torque, especially with wider implants and in denser bone. Underpreparation is generally more effective than overpreparation. However, in very soft bone, neither implant geometry nor drilling adaptations reliably achieve optimal primary stability, highlighting the need for additional strategies.


  • Open Access

    Intraoperative Profiling of the Supracrestal Implant Complex Minimizes Peri-Implant Crestal Bone Remodeling: The Guided Bone Profiling Concept

    by Milan Stoilov, Joerg Winterhoff, Lea Stoilov, Anastasia Timoschenko, Helmut Stark, Florian Heuser, Michael Marder, Dominik Kraus, Norbert Enkling

    (1) Background: Early-stage bone resorption following implant placement can significantly impact the long-term success of implants. This study evaluates whether a fully digitally planned implant position based on the E-point concept, along with guided profiling of the supracrestal complex, contributes to improved stability of peri-implant bone levels. (2) Methods: 29 implants were placed in 27 patients utilizing both immediate (Group 1; n = 19) and delayed placement (Group 2; n = 10) protocols. Implant position and emergence profile were preoperatively determined and consistently executed through guided surgery and CAD/CAM-fabricated restorations. Due to the subcrestal positioning of the implant, a corresponding bone profiler with a guide pin was used to shape the emergence profile and prevent the provisional restoration from impinging on the proximal bone. Provisional restorations were immediately placed to support the emergence profile. Bone level changes were documented radiographically over a two-year period. The first Bone-to-Implant Contact Level (∆ fBIC), change in highest approximal Bone Level (∆ haBL), and formation of an emergence profile width (WEP) were measured. (3) Results: All implants and restorations survived after two years, no significant change in first Bone-to-Implant Contact Level (∆ fBIC = 0 ± 0.02 mm), no change in highest approximal Bone Level (∆ haBL) of −0.23 mm ± 0.71 mm, and formation of an emergence profile width (WEP) averaging 0.18 ± 0.19 mm. (4) Conclusions: Despite the initial stress on the bone caused by bone profiling, guided implant placement and bone shaping, supported by an immediate provisional, have a positive effect on peri-implant bone stability.


  • Open Access

    Influence of Cementation Mode and Ferrule Design on the Fatigue Resistance of Monolithic Zirconia Endocrowns

    by Milan Stoilov, Tobias Boehmer, Lea Stoilov, Helmut Stark, Michael Marder, Norbert Enkling, Dominik Kraus

    Background: Classic endocrowns made of dental ceramics are considered a promising alternative to traditional post-endodontic restorations. The use of circular ferrules in endocrowns is a topic of controversial discussion. Therefore, the present study aims to evaluate the effect of ferrule design and cementation mode on the fatigue resistance of zirconia endocrowns. Methods: Eighty human molars were divided into four groups (n = 20): NFC (no-ferrule, conventional cementation), NFA (no-ferrule, adhesive luting), FC (ferrule, conventional cementation) and FA (ferrule, adhesive luting). Both the classic and the modified endocrown preparation with a two-millimeter ferrule design were carried out. Endocrowns were fabricated from zirconia using the CEREC system. After thermocycling, specimens were loaded according to the step-stress test up to 1500 N. Results: Failure rate was low; 88.8% of total specimens passed the step-stress test. Fractures were distributed between all groups; no significant differences in fatigue resistance were detected for preparation design and cementation mode. Conclusions: Endocrowns appear to be a promising concept for endodontically treated molars. Ferrule and also cementation mode have only a minor influence on fatigue resistance of zirconia endocrowns. However, at very high forces, the marginal area of the ferrule represents a weak point.


  • Open Access

    Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols—An In Vitro Analysis

    by Milan Stoilov, Ramin Shafaghi, Helmut Stark, Michael Marder, Dominik Kraus, Norbert Enkling

    (1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel-walled and one tapered) with various lengths and diameters were inserted into polyurethane foam blocks of different densities (35, 25, 15, and 10 PCF) using standard drilling protocols. Primary stability was assessed through insertion torque (IT) and resonance frequency analysis (RFA). Optimal ranges were defined for IT (25 to 50 Ncm) and RFA (ISQ 60 to 80). A comparison of implant groups was conducted to determine adherence to the optimal ranges. (3) Results: Implant macro-design, -length, and -diameter and bone block density significantly influenced IT and RFA. Optimal IT was observed in 8/40 and 9/40 groups for the parallel-walled implants, while the tapered implant achieved optimal IT in 13/40 groups (within a 25–50 Ncm range). Implant diameter strongly impacted primary stability, with sufficient stability achieved in only one-third of cases despite the tapered implant’s superiority. (4) Conclusions: The findings highlight the need to adapt the drilling protocol based on diverse bone qualities in clinical practice. Further investigations should explore the impact of these adapted protocols on implant outcomes.


  • Open Access

    Prevalence of Peri-Implant Disease in Patients with Stage III or IV Periodontitis: Results of a Long-Term Follow-Up from a Specialized Periodontal Practice

    by Pia-Merete Jervøe-Storm, Michael Marder, Martin Hagner, Ina Menn, Philipp Menn, Søren Jepsen

    The aim of this study was to examine the conditions of implants that had been in function for 5–17 years in stage III/IV periodontitis patients of a specialized periodontal practice. There were 83 patients (43 female/40 male, mean age 64.4 (9.69) years), with a total of 213 implants, who participated in the study. Assessments included periodontal and peri-implant probing depths, bleeding and plaque scores, and a radiographic examination. Smoking habits, participation in a supportive care program (SCP), and the Implant Disease Risk Assessment (IDRA) scores were recorded. A total of 44 patients presented with stage III periodontitis, and 39 with stage IV. In all, 85% of patients had adhered to regular SCP. On an implant/patient level, peri-implant health was found in 37.1.7% (79 implants)/24.1% (20 patients), peri-implant mucositis in 58.7% (125 implants)/66.3% (55 patients), and peri-implantitis in 4.2% (9 implants)/9.6% (8 patients). IDRA scores showed 30.5% of implants at moderate and 69.5% at high risk. The present long-term analysis shows a high prevalence of peri-implant disease in patients treated for advanced periodontitis. These findings underline the challenges involved in the long-term maintenance of oral health in stage III/IV periodontitis patients restored with dental implants.


  • Open Access

    Prevention of internal bacterial colonization of dental implants: A comparative longitudinal observational study

    by Pia‐Merete Jervøe‐Storm, Søren Jepsen, Michael Marder, Dominik Kraus, Milan Stoilov, Norbert Enkling

    Objectives: Previous studies have indicated a progressive internal bacterial colonization of implants and possible implications for peri‐implant bone loss. The aim of this study was to evaluate a decontamination protocol, two disinfectants, and a sealant for their ability to prevent such a colonization.Materials and Methods: Bacterial samples were harvested from the peri‐implant sulcus (external) and following abutment removal from the implant cavity (internal) during routine supportive peri‐implant care in 30 edentulous patients 2 years after they had obtained two implants. In a split‐mouth design, implants were randomly assigned to receive either internal decontamination alone (10% H2O2, brush) or additional placement of either sealant (GS), disinfectant agent (CHX‐varnish) or disinfectant gel (1% CHX‐gel), in the internal cavity before remounting of abutment/suprastructure. Twelve months later, internal and external sampling was repeated. Total bacterial counts (TBCs) were determined using real‐time PCR in a total of 240 samples (eight per patient).Results: Total bacterial counts in the internal cavity significantly reduced overall treatment modalities 1 year after the treatments (4.0 [2.3–6.9]‐fold reduction; p = .000). No significant differences between the four treatment types were found (p = .348). Comparison of internal and external sampling points revealed significant correlation (R2 = .366; p = .000) with systematically higher TBC counts in external samples.Conclusions: Within the limitations of the present study, it can be concluded that the use of disinfectant agents or a sealant did not show an additional benefit in the prevention of internal bacterial colonization of implants compared to a decontamination protocol alone.


  • Open Access

    Effects of Different Titanium Surface Treatments on Adhesion, Proliferation and Differentiation of Bone Cells: An In Vitro Study

    by Milan Stoilov, Lea Stoilov, Norbert Enkling, Helmut Stark, Jochen Winter, Michael Marder, Dominik Kraus

    The objective of this study was to evaluate the impacts of different sandblasting procedures in acid etching of Ti6Al4V surfaces on osteoblast cell behavior, regarding various physicochemical and topographical parameters. Furthermore, differences in osteoblast cell behavior between cpTi and Ti6Al4V SA surfaces were evaluated. Sandblasting and subsequent acid etching of cpTi and Ti6Al4V discs was performed with Al2O3 grains of different sizes and with varying blasting pressures. The micro- and nano-roughness of the experimental SA surfaces were analyzed via confocal, atomic force and scanning electron microscopy. Surface free energy and friction coefficients were determined. hFOB 1.19 cells were seeded to evaluate adhesion, proliferation and osteoblastic differentiation for up to 12 d via crystal violet assays, MTT assays, ALP activity assays and Alizarin Red staining assays. Differences in blasting procedures had significant impacts on surface macro- and micro-topography. The crystal violet assay revealed a significant inverse relationship between blasting grain size and hFOB cell growth after 7 days. This trend was also visible in the Alizarin Red assays staining after 12 d: there was significantly higher biomineralization visible in the group that was sandblasted with smaller grains (F180) when compared to standard-grain-size groups (F70). SA samples treated with reduced blasting pressure exhibited lower hFOB adhesion and growth capabilities at initial (2 h) and later time points for up to 7 days, when compared to the standard SA surface, even though micro-roughness and other relevant surface parameters were similar. Overall, etched-only surfaces consistently exhibited equivalent or higher adhesion, proliferation and differentiation capabilities when compared to all other sandblasted and etched surfaces. No differences were found between cpTi and Ti6Al4V SA surfaces. Subtle modifications in the blasting protocol for Ti6Al4V SA surfaces significantly affect the proliferative and differentiation behavior of human osteoblasts. Surface roughness parameters are not sufficient to predict osteoblast behavior on etched Ti6Al4V surfaces.