Vitaliy Sechenyh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vitaliy Sechenyh has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Aliaksandr Mialdun
Microgravity Research Center, CP-165/62, Université libre de Bruxelles (ULB), 50, Ave. F.D. Roosevelt, B-1050 Brussels, Belgium
6 shared publications - Valentina Shevtsova
Mondragón University
5 shared publications - Vitaliy P. Zhelezny
Одеський національний технологічний університет, вул. Канатна, 112, Одеса, 65039, Україна
5 shared publications Jean-Claude Legros
4 shared publicationsValentina Shevtsova
4 shared publications- Yury Semenyuk
Odessa National Academy of Food Technologies Kanatna str., 112, Odessa, Ukraine, 65039
3 shared publications
Latest Publications
- Open Access
- 15 July 2019
- Published by SAGE Publications in International Journal of Engine Research
- Vol. 21 (1) , 43-54
Quantitative analysis of dribble volumes and rates using three-dimensional reconstruction of X-ray and diffused back-illumination images of diesel sprays
Post-injection fuel dribble is known to lead to incomplete atomisation and combustion due to the release of slow-moving, and often surface-bound, liquid fuel after the end of injection. This can have a negative effect on engine emissions, performance and injector durability. To better quantify this phenomenon, we developed an image-processing approach to measure the volume of ligaments produced during the end of injection. We applied our processing approach to an Engine Combustion Network ‘Spray B’ 3-hole injector, using datasets from 220 injections generated by different research groups, to decouple the effect of gas temperature and pressure on the fuel dribble process. High-speed X-ray phase-contrast images obtained at room temperature conditions (297 K) at the Advanced Photon Source at Argonne National Laboratory, together with diffused back-illumination images captured at a wide range of temperature conditions (293–900 K) by CMT Motores Térmicos were analysed and compared quantitatively. We found a good agreement between image sets obtained by Argonne National Laboratory and CMT Motores Térmicos using different imaging techniques. The maximum dribble volume within the field of view of the imaging system and the mean rate of fuel dribble were considered as characteristic parameters of the fuel dribble process. Analysis showed that the absolute mean dribble rate increases with temperature when injection pressure is higher than 1000 bar and slightly decreases at high injection pressures (>500 bar) when temperature is close to 293 K. Larger maximum volumes of the fuel dribble were observed at lower gas temperatures (∼473 K) and low gas pressures (<30 bar), with a slight dependence on injection pressure.
- 15 July 2019
- Published by SAGE Publications in International Journal of Engine Research
- Vol. 21 (1) , 43-54
Open AccessQuantitative analysis of dribble volumes and rates using three-dimensional reconstruction of X-ray and diffused back-illumination images of diesel sprays
Post-injection fuel dribble is known to lead to incomplete atomisation and combustion due to the release of slow-moving, and often surface-bound, liquid fuel after the end of injection. This can have a negative effect on engine emissions, performance and injector durability. To better quantify this phenomenon, we developed an image-processing approach to measure the volume of ligaments produced during the end of injection. We applied our processing approach to an Engine Combustion Network ‘Spray B’ 3-hole injector, using datasets from 220 injections generated by different research groups, to decouple the effect of gas temperature and pressure on the fuel dribble process. High-speed X-ray phase-contrast images obtained at room temperature conditions (297 K) at the Advanced Photon Source at Argonne National Laboratory, together with diffused back-illumination images captured at a wide range of temperature conditions (293–900 K) by CMT Motores Térmicos were analysed and compared quantitatively. We found a good agreement between image sets obtained by Argonne National Laboratory and CMT Motores Térmicos using different imaging techniques. The maximum dribble volume within the field of view of the imaging system and the mean rate of fuel dribble were considered as characteristic parameters of the fuel dribble process. Analysis showed that the absolute mean dribble rate increases with temperature when injection pressure is higher than 1000 bar and slightly decreases at high injection pressures (>500 bar) when temperature is close to 293 K. Larger maximum volumes of the fuel dribble were observed at lower gas temperatures (∼473 K) and low gas pressures (<30 bar), with a slight dependence on injection pressure.
- Open Access
- 6 September 2017
- Published by Universitat Politecnica de Valencia
Quantification of diesel injector dribble using 3D reconstruction from x-ray and DBI imaging
Post-injection dribble is known to lead to incomplete atomisation and combustion due to the release of slowmoving, and often surface-bound, liquid fuel after the end of the injection event. This can have a negative effect on engine emissions, performance, and injector durability. To better quantify this phenomenon we present a new image processing approach to quantify the volume and surface area of ligaments produced during the end of injection, for an ECN ‘Spray B’ 3-hole injector. Circular approximation for cross-sections was used to estimate three-dimensional parameters of droplets and ligaments. The image processing consisted in three stages: edge detection, morphological reconstruction, and 3D reconstruction. For the last stage of 3D reconstruction, smooth surfaces were obtained by computation of the alpha shape which represents a bounding volume enveloping a set of 3D points. The object model was verified by calculation of surface area and volume from 2D images of figures with well-known shapes. We show that the object model fits non-spherical droplets and pseudo-cylindrical ligaments reasonably well. We applied our processing approach to datasets generated by different research groups to decouple the effect of gas temperature and pressure on the fuel dribble process. High-speed X-ray phase-contrast images obtained at room temperature conditions (297 K) at the 7-ID beamline of the Advanced Photon Source at Argonne National Laboratory, together with diffused back-illumination (DBI) images captured at a wide range of temperature conditions (293-900 K) by CMT Motores Térmicos, were analysed and comparedquantitatively.DOI: http://dx.doi.org/10.4995/ILASS2017.2017.4742
- 6 September 2017
- Published by Universitat Politecnica de Valencia
Open AccessQuantification of diesel injector dribble using 3D reconstruction from x-ray and DBI imaging
Post-injection dribble is known to lead to incomplete atomisation and combustion due to the release of slowmoving, and often surface-bound, liquid fuel after the end of the injection event. This can have a negative effect on engine emissions, performance, and injector durability. To better quantify this phenomenon we present a new image processing approach to quantify the volume and surface area of ligaments produced during the end of injection, for an ECN ‘Spray B’ 3-hole injector. Circular approximation for cross-sections was used to estimate three-dimensional parameters of droplets and ligaments. The image processing consisted in three stages: edge detection, morphological reconstruction, and 3D reconstruction. For the last stage of 3D reconstruction, smooth surfaces were obtained by computation of the alpha shape which represents a bounding volume enveloping a set of 3D points. The object model was verified by calculation of surface area and volume from 2D images of figures with well-known shapes. We show that the object model fits non-spherical droplets and pseudo-cylindrical ligaments reasonably well. We applied our processing approach to datasets generated by different research groups to decouple the effect of gas temperature and pressure on the fuel dribble process. High-speed X-ray phase-contrast images obtained at room temperature conditions (297 K) at the 7-ID beamline of the Advanced Photon Source at Argonne National Laboratory, together with diffused back-illumination (DBI) images captured at a wide range of temperature conditions (293-900 K) by CMT Motores Térmicos, were analysed and comparedquantitatively.DOI: http://dx.doi.org/10.4995/ILASS2017.2017.4742
- 1 October 2016
- Published by Elsevier in Journal of Fluids and Structures
- Vol. 66, 282-292
An experimental study for impact of a drop onto a particle in mid-air: The influence of particle wettability
- 1 October 2016
- Published by Elsevier in Journal of Fluids and Structures
- Vol. 66, 282-292
An experimental study for impact of a drop onto a particle in mid-air: The influence of particle wettability
- 12 January 2016
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 120 (3) , 535-548
Fickian Diffusion in Ternary Mixtures Composed by 1,2,3,4-Tetrahydronaphthalene, Isobutylbenzene, and n-Dodecane
We report the Fickian diffusion coefficients in 20 ternary mixtures formed by 1,2,3,4-tetrahydronaphthalene (THN), isobutylbenzene (IBB) and n-dodecane (nC12) measured by the Taylor dispersion technique at 298.1 K and atmospheric pressure. Four diffusion coefficients of the ternary mixtures were measured along six concentration paths starting on one binary subsystem and moving toward the other one. We found expressions for the diffusion matrix of a ternary mixture approaching to the binary limits. The measured diffusion coefficients were thoroughly verified by comparison with the theoretical asymptotic behavior. The main diffusion coefficients vary smoothly over the entire concentration space and D11 is always larger than D22. One of the two cross-diffusion coefficients is of the same order of magnitude as the main ones and, hence, not negligible, whereas the other one is close to zero. The investigated mixtures also comprise compositions that were examined in microgravity experiments in the ESA DCMIX1 project.
- 12 January 2016
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 120 (3) , 535-548
Fickian Diffusion in Ternary Mixtures Composed by 1,2,3,4-Tetrahydronaphthalene, Isobutylbenzene, and n-Dodecane
We report the Fickian diffusion coefficients in 20 ternary mixtures formed by 1,2,3,4-tetrahydronaphthalene (THN), isobutylbenzene (IBB) and n-dodecane (nC12) measured by the Taylor dispersion technique at 298.1 K and atmospheric pressure. Four diffusion coefficients of the ternary mixtures were measured along six concentration paths starting on one binary subsystem and moving toward the other one. We found expressions for the diffusion matrix of a ternary mixture approaching to the binary limits. The measured diffusion coefficients were thoroughly verified by comparison with the theoretical asymptotic behavior. The main diffusion coefficients vary smoothly over the entire concentration space and D11 is always larger than D22. One of the two cross-diffusion coefficients is of the same order of magnitude as the main ones and, hence, not negligible, whereas the other one is close to zero. The investigated mixtures also comprise compositions that were examined in microgravity experiments in the ESA DCMIX1 project.
- 27 April 2015
- Published by Springer Nature in The European Physical Journal E
- Vol. 38 (4) , 1-15
Contribution to the benchmark for ternary mixtures: Measurement of the Soret, diffusion and thermodiffusion coefficients in the ternary mixture THN/IBB/nC12 with 0.8/0.1/0.1 mass fractions in ground and orbital laboratories
We have determined the Soret (ST), diffusion (D, and thermodiffusion (DT) coefficients in a ternary mixture of tetralin-isobutylbenzene-n-dodecane with a composition of 0.80/0.10/0.10 by mass fraction at a temperature of 298K. The Soret coefficients were measured in the microgravity experiment DCMIX1 and on the ground by optical digital interferometry (ODI) using two lasers with different wavelengths. The values of the Soret coefficients were determined from the stationary separation of the components using two- and six-parameter fits. The diffusion coefficients were independently measured using the Taylor Dispersion Technique in the ground laboratory, and the thermodiffusion coefficients were derived from known ST and matrix D. The processing of the data from the DCMIX experiment conducted on the International Space Station is discussed in detail. The multi-user design of the on-board instrument causes perturbations in the component separation. Several recommendations are suggested for improving the quality of the microgravity results. For example, we demonstrated that the tomography reconstruction of the 3-D concentration field allows to restore the underestimated component separation resulting from the spatial non-linearity of the temperature field. Furthermore, to avoid errors in component separation due to mass exchange between the working liquid volume and the expansion volume at the top of the cell, we suggest considering the evolution of the separation only in the lower half of the cell. The results of this study displayed reasonable quantitative agreement between the microgravity and ground experiments.
- 27 April 2015
- Published by Springer Nature in The European Physical Journal E
- Vol. 38 (4) , 1-15
Contribution to the benchmark for ternary mixtures: Measurement of the Soret, diffusion and thermodiffusion coefficients in the ternary mixture THN/IBB/nC12 with 0.8/0.1/0.1 mass fractions in ground and orbital laboratories
We have determined the Soret (ST), diffusion (D, and thermodiffusion (DT) coefficients in a ternary mixture of tetralin-isobutylbenzene-n-dodecane with a composition of 0.80/0.10/0.10 by mass fraction at a temperature of 298K. The Soret coefficients were measured in the microgravity experiment DCMIX1 and on the ground by optical digital interferometry (ODI) using two lasers with different wavelengths. The values of the Soret coefficients were determined from the stationary separation of the components using two- and six-parameter fits. The diffusion coefficients were independently measured using the Taylor Dispersion Technique in the ground laboratory, and the thermodiffusion coefficients were derived from known ST and matrix D. The processing of the data from the DCMIX experiment conducted on the International Space Station is discussed in detail. The multi-user design of the on-board instrument causes perturbations in the component separation. Several recommendations are suggested for improving the quality of the microgravity results. For example, we demonstrated that the tomography reconstruction of the 3-D concentration field allows to restore the underestimated component separation resulting from the spatial non-linearity of the temperature field. Furthermore, to avoid errors in component separation due to mass exchange between the working liquid volume and the expansion volume at the top of the cell, we suggest considering the evolution of the separation only in the lower half of the cell. The results of this study displayed reasonable quantitative agreement between the microgravity and ground experiments.
- 13 February 2015
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 767, 290-322
Dynamics of a binary mixture subjected to a temperature gradient and oscillatory forcing
We examine the dynamics of a binary mixture in a cubic cell subjected to a temperature differential and oscillatory forcing. The Soret effect, which is negative in the present study, provides a coupling mechanism by which a temperature gradient establishes a concentration gradient in a mixture. We present the results of experiments that were performed on the International Space Station (ISS) and compare the observations with the results of direct numerical simulations. The evolution of temperature and concentration fields is investigated by optical digital interferometry. One advantage of the experimental technique is the observation of the fields along two perpendicular directions of the cell, allowing us to restore the three-dimensional field. Experimental evidence disproves speculations that the ISS microgravity environment always affects diffusion-controlled processes. Furthermore, we demonstrate that imposed vibrations with constant frequency and amplitude create slow mean flows and that they do influence the diffusion kinetics. The perturbation of the diffusive fields scales as the square of the vibrational velocity. In addition to calculations of the full three-dimensional Navier–Stokes equations, a two-time-scale computational methodology is used for situations in which the forcing period is very small compared to the natural time scales of the problem. The simulations show excellent agreement with experimental observations.
- 13 February 2015
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 767, 290-322
Dynamics of a binary mixture subjected to a temperature gradient and oscillatory forcing
We examine the dynamics of a binary mixture in a cubic cell subjected to a temperature differential and oscillatory forcing. The Soret effect, which is negative in the present study, provides a coupling mechanism by which a temperature gradient establishes a concentration gradient in a mixture. We present the results of experiments that were performed on the International Space Station (ISS) and compare the observations with the results of direct numerical simulations. The evolution of temperature and concentration fields is investigated by optical digital interferometry. One advantage of the experimental technique is the observation of the fields along two perpendicular directions of the cell, allowing us to restore the three-dimensional field. Experimental evidence disproves speculations that the ISS microgravity environment always affects diffusion-controlled processes. Furthermore, we demonstrate that imposed vibrations with constant frequency and amplitude create slow mean flows and that they do influence the diffusion kinetics. The perturbation of the diffusive fields scales as the square of the vibrational velocity. In addition to calculations of the full three-dimensional Navier–Stokes equations, a two-time-scale computational methodology is used for situations in which the forcing period is very small compared to the natural time scales of the problem. The simulations show excellent agreement with experimental observations.
- 1 April 2014
- Published by Elsevier in International Journal of Refrigeration
- Vol. 40, 241-245
Prediction of the surface tension for refrigerants and refrigerant-oil solutions (ROS)
- 1 April 2014
- Published by Elsevier in International Journal of Refrigeration
- Vol. 40, 241-245
Prediction of the surface tension for refrigerants and refrigerant-oil solutions (ROS)
- 10 September 2013
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 139 (10) , 104903
Investigation of Fickian diffusion in the ternary mixture of 1,2,3,4-tetrahydronaphthalene, isobutylbenzene, and dodecane
We present a comprehensive analysis of experimental results obtained for Fickian diffusion in the benchmark ternary liquid mixture of 1,2,3,4-tetrahydronaphthalene, isobutylbenzene, and dodecane (nC12) with equal mass fractions. Isothermal diffusion coefficients have been measured by two independent experimental methods: by Taylor dispersion technique, and by a counter flow cell fitted with an optical interferometry device. The experimental diffusion matrices have been critically analyzed regarding the Onsager reciprocal relations, for which we introduce a matrix asymmetry index s2 that is independent of the frame of reference and the component order.
- 10 September 2013
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 139 (10) , 104903
Investigation of Fickian diffusion in the ternary mixture of 1,2,3,4-tetrahydronaphthalene, isobutylbenzene, and dodecane
We present a comprehensive analysis of experimental results obtained for Fickian diffusion in the benchmark ternary liquid mixture of 1,2,3,4-tetrahydronaphthalene, isobutylbenzene, and dodecane (nC12) with equal mass fractions. Isothermal diffusion coefficients have been measured by two independent experimental methods: by Taylor dispersion technique, and by a counter flow cell fitted with an optical interferometry device. The experimental diffusion matrices have been critically analyzed regarding the Onsager reciprocal relations, for which we introduce a matrix asymmetry index s2 that is independent of the frame of reference and the component order.
- 17 August 2013
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 25 (5) , 275-283
Diffusion and Soret in Ternary Mixtures. Preparation of the DCMIX2 Experiment on the ISS
- 17 August 2013
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 25 (5) , 275-283
Diffusion and Soret in Ternary Mixtures. Preparation of the DCMIX2 Experiment on the ISS