Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aleksandr Barannikov has a total of 95 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Testing of X-ray Optics for Synchrotron Studies using a Laboratory Microfocus X-ray Source

    by A. A. Barannikov, D. A. Zverev, I. I. Lyatun, I. B. Panormov, K. V. Rudenko, A. A. Snigirev

    This paper considers techniques for testing X-ray optics in laboratory conditions before its direct use at synchrotron radiation sources. The example of the ‘SynchrotronLike’ complex demonstrates the capabilities of modern laboratory X-ray optical equipment for studying the optical and functional properties of refractive X-ray lenses, transfocators, and diamond monochromators. Moreover, the paper describes ways of realizing synchrotron coherent experimental techniques such as microradian X-ray diffraction and X-ray reflecto-interferometry in laboratory conditions. Applying the high-brightness Excillum MetalJet microfocus X-ray tube with a liquid anode enables experiments with several optical transformations and provides higher spatial coherence of the radiation compared to classical laboratory sources. The high coherence of the radiation allows for observing interference on thin films and test X-ray interferometers. The presented results demonstrate the capabilities of modern laboratory X-ray optical equipment in solving problems that do not require high temporal and energy resolution. It significantly saves resources spent on research based on synchrotron radiation sources when a lot of measurements and tests for optimization of X-ray optics fabrication technology are required.


  • X-ray diffraction imaging of the diamond anvils based on the microfocus x-ray source with a liquid anode

    by Aleksandr Barannikov, Ivan Troyan, Irina Snigireva, Anatoly Snigirev

    This paper presents the results of using laboratory x-ray systems in the study of the crystal structure of anvil made from single-crystal diamond. The system is equipped with an Excillum MetalJet D2 + 70 kV high-brightness x-ray source with a liquid GaIn anode. The x-ray diffraction imaging (topography) technique with the use of a high-resolution x-ray Rigaku camera was applied to analyze crystal structure defects. Two-dimensional images were experimentally recorded using 400 and 111 reflections with a resolution of 1.5 and 5 μm, respectively. These topograms displayed various defects, such as growth striations and dislocations. Possible applications of the proposed laboratory-based optical scheme for high-pressure physics are discussed and future improvements to the setup are suggested.


  • X-ray diffraction imaging of diamond x-ray optics in the laboratory

    by Aleksandr Barannikov, Sergey Shevyrtalov, Maxim Polikarpov, Irina Snigireva, Anatoly Snigirev

    This paper presents the results of using the laboratory X-ray system to study the diamond X-ray optics: single-crystal diamond plates and diamond X-ray parabolic refractive lenses. The system is equipped with the Excillum MetalJet D2+ 70kV high-brightness X-ray source with a liquid GaIn anode. To analyze the defects of the crystal structure, the X-ray diffraction imaging (topography) technique was applied. Two-dimensional images of the diamond plate were experimentally recorded from (111) crystal plane with 12 μm and 1.5 μm resolution. The images of the X-ray semi-lens were recorded from (400) and (220) crystal planes with 20 μm resolution. These topographs displayed various defects, such as growth striations and dislocations.


  • Synthetic single crystal diamonds for X-ray optics

    by Sergey Shevyrtalov, Aleksandr Barannikov, Yuri N. Palyanov, Alexander F. Khokhryakov, Yuri M. Borzdov, Ilya Sergueev, Sergey Rashchenko, Anatoly A. Snigirev

    In the manuscript we report on characterization of single-crystalline (111) plates prepared from type Ib diamonds with nitrogen content of 100-150 ppm and (100) plates prepared from IIa diamond by means of high-resolution rocking curve imaging (RCI). Contrary to a common opinion about intrinsic poor diffraction quality of type Ib diamonds, RCI showed the presence of nearly defect-free areas of several mm2 in the central part of the (111)-oriented diamond plates. In comparison with the (100)-oriented IIa diamond plates prepared by the same HPHT setup the Ib diamonds possess better diffraction quality. The observed broadening of the rocking curves associates with the cutting and polishing processes, causing strains around the edges of the plates and rare defects. An improvement of preparation technique will thus allow to make single-crystalline diamond plates for Laue and Bragg monochromators and beam splitters from type Ib diamond with areas large enough to be used as wavefront-preserving optical elements at 4th generation synchrotron facilities. Contrary to a common opinion about intrinsically poor diffraction quality of type I diamonds, RCI showed the presence of nearly defect-free areas of several mm2 in the central part of the diamond plates. The observed broadening of the rocking curves results from the cutting and polishing processes, causing strains around the edges of the plates and rare defects. An improvement of preparation technique will thus allow to make single-crystalline diamond plates for Laue and Bragg monochromators and beam splitters from type Ib material with areas large enough to be used as optical elements at 4th generation synchrotron facilities.


  • Laboratory complex for the tests of the X-ray optics and coherence-related techniques

    by Aleksandr Barannikov, Sergey Shevyrtalov, Dmitrii Zverev, Anton Narikovich, Aleksandr Sinitsyn, Igor Panormov, Irina Snigireva, Anatoly Snigirev

    The requirement for the high-quality optics for the 4th generation synchrotrons is becoming particularly urgent nowadays. We present a laboratory complex “SynchrotronLike” designed for the X-ray optics tests and development of the X-ray optical techniques before their use on the synchrotron sources. This complex consists of four main parts: 1) microfocus Xray source MetalJet D2+ 70kV, 2) detector module that contains X-ray spectrometer and three X-ray cameras with different resolution and field of view, 3) Micro-Optics Test Bench for X-ray optics tests and development of the X-ray optical techniques, 4) X-ray Single Crystal Diagnostics Endstation for the X-ray diffraction microscopy experiments. This complex was successfully used for the preliminary tests of the X-ray refractive lenses made from polymer, epoxy, and diamond. Moreover, the ultracompact X-ray transfocators, diamond monochromators, and beam-splitters for the 4th generation synchrotron sources were also tested on the “SynchrotronLike”. The unique parameters of our laboratory source, such as high brightness and high beam coherency make it possible to implement versatile experimental synchrotron techniques. Consequently, we managed to get excellent results in the X-ray reflecto-interferometry and X-ray microradian diffraction. The results of the latter technique are presented in this paper.


  • X-ray interferometry technique for thin-films study using an x-ray microfocus laboratory source

    by Maria Voevodina, Svetlana Lyatun, Dmitrii Zverev, Aleksandr Barannikov, Ivan Lyatun, Irina Snigireva

    We are proposing an X-ray reflecto-interferometry technique using an x-ray microfocus laboratory source for thin-film structure research based on compound refractive lenses. The idea of this technique is to use a very simplified experimental setup where a focused X-ray beam reflected from parallel flat surfaces creates an interference pattern in a wide angular range. Due to this, the interference pattern can be obtained in a single shot without the need to rotate the specimen or the detector. The applicability of this technique has been demonstrated using the MetalJet Excillium microfocus laboratory source, which has GaKα emission line at 9.25 keV. A series of interference patterns for Si3N4 membranes and the experimentally obtained film thickness are in good agreement with the declared characteristics. The main advantages and future possible of the reflecto-interferometry technique are discussed.

  • X-ray Reflecto-Interferometry Technique Using a Microfocus Laboratory Source

    by M. A. Voevodina, S. S. Lyatun, A. A. Barannikov, I. I. Lyatun, I. I. Snigireva, A. A. Snigirev

    An X-ray interferometry technique using an X-ray microfocus laboratory source for thin-film structure research based on compound refractive lenses has been proposed. The main advantage of this technique is to use a very simplified experimental setup where a focused X-ray beam reflected from parallel flat surfaces creates an interference pattern in a wide angular range. Due to this, the interference pattern can be obtained in a single shot without the need to rotate the specimen or the detector. The applicability of this technique has been demonstrated using the MetalJet Excillium micro-focus laboratory source, which has GaKα emission line at 9.25 keV. As a result, a series of interference patterns for test sample a free-standing thin-film membrane, thickness 500 nm, was observed. Based on the obtained results the main advantages of this technique such as high spatial and temporal resolution are shown, and also possible application of the reflecto-interferometry both at the laboratory and synchrotron radiation X-ray sources are proposed.


  • Towards high-quality nitrogen-doped diamond single crystals for X-ray optics

    by Sergey Shevyrtalov, Alexander Barannikov, Yurii Palyanov, Alexander Khokhryakov, Yurii Borzdov, Ilya Sergueev, Sergey Rashchenko, Anatoly Snigirev

    In this manuscript, characterization of single-crystalline (111) plates prepared from type-Ib diamonds with a nitrogen content of 100–150 ppm by means of high-resolution rocking-curve imaging (RCI) is reported. Contrary to common opinion regarding the intrinsically poor diffraction quality of type-I diamonds, RCI showed the presence of nearly defect-free areas of several millimetres squared in the central part of the diamond plates. The observed broadening of the rocking curves is a result of the cutting and polishing processes, causing strains around the edges of the plates and rare defects. An improvement of the preparation technique will thus allow single-crystalline diamond plates to be made for Laue and Bragg monochromators and beam splitters from type-Ib material with areas large enough to be used as optical elements at fourth-generation synchrotron facilities.


  • Metrological approach for diagnostics of x-ray refractive lenses

    by A. Narikovich, D. Zverev, A. Barannikov, I. Lyatun, I. Panormov, A. Sinitsyn, I. Snigireva, A. Snigirev

    The paper presents a method for metrological studies of the profiles of X-ray refractive lenses using laboratory tomography and phase contrast imaging techniques. The method is based on an algorithm that analyzes images of a refractive lens with a further approximation of the data obtained by a parabola by the least-squares method using regression analysis. The use of regression analysis allows us to evaluate the adequacy of the proposed model of the geometric description of the lens profile, thus ensuring the reliability and repeatability of the measurement results. The developed comprehensive laboratory metrological approach allows you to control the quality of the basic geometric characteristics of refractive lenses and, thus, significantly improve their quality by properly adjusting the production process.


  • X-ray interferometry technique using an x-ray microfocus laboratory source

    by Maria Voevodina, Svetlana Lyatun, Aleksandr Barannikov, Ivan Lyatun, Irina Snigireva

    X-ray reflecto-interferometry technique based on compound refractive lenses using an x-ray laboratory source was proposed to study thin-film structures. The setup for this experiment is very simple: a focused x-ray beam is reflected from parallel flat surfaces, which creates an interference pattern in a wide angular range, therefore the interference pattern can be obtained in a single shot without the need to rotate the sample or the detector. The reflecto-interferograms for Si3N4 membranes were obtained using the MetalJet Excillium micro-focus laboratory source with GaKα emission line at 9.25 keV. The experimentally obtained film thickness is in good agreement with the declared characteristics.