NKNataliya Klimova

Nataliya Klimova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nataliya Klimova has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diffraction Losses in a Stack of Diamond X-Ray Lenses

    by Nataliya Klimova, Anatoly Snigirev

    Compound refractive lenses, crafted from single-crystal materials like diamond and silicon, are increasingly favored, particularly in cutting-edge facilities, such as free electron lasers and fourth-generation synchrotrons. These lenses are prized for their low parasitic scattering and resistance to significant radiation doses over extended periods. However, they do encounter a notable drawback known as the “glitch effect”, wherein undesired diffraction can occur across various X-ray energies. This phenomenon leads to a decrease in transmitted intensity, impacting experiments, particularly in spectroscopy. Typically, a series of lenses is employed to achieve optimal beam parameters, and each lens has its own spectrum of glitches. This paper presents experimentally measured glitches in stacks of 1, 4, 8, and 16 diamond compound refractive lenses, elucidating the theory behind glitch formation and offering strategies to predict and mitigate glitches in diverse focusing systems employing lenses made from single-crystal materials.


  • Determining the Orientation of a Single-Crystal and the Absolute Energy of X-Rays Using Diffraction Losses

    by N. B. Klimova, A. A. Snigirev

    The intensity loss of a transmitted beam due to parasitic diffraction (glitches) is an inherent property of single-crystal X-ray optics. This effect can lead to a weakening of the radiation, up to its complete disappearance. Therefore, understanding the effect of diffraction loss is essential for any experiments that use single-crystal optics. We present the theory of glitch formation and demonstrate its application to experimental data to determine the orientation and cell parameters of optical elements made of single-crystal diamond. A systematic error is found in determining the absolute energy of X-ray radiation, which occurs due to the inexact tuning of a monochromator (error in determining the absolute 2θ angle). The described error very often occurs during the experiment due to the fact that determining the absolute 2θ angle of a monochromator crystal is a technically difficult task. Simultaneous determination of the orientation and lattice parameters of the studied sample, together with compensation of the systematic error in the monochromator tuning, made it possible to significantly improve the accuracy of processing the obtained data.

  • The Method for Determining the Exact Single Crystal Orientation with Simultaneous X-Ray Energy Correction Using the Spectrum of Diffraction Losses

    by N. B. Klimova, A. A. Snigirev

    The Method for Determining the Exact Single Crystal Orientation with Simultaneous X-Ray Energy Correction Using the Spectrum of Diffraction Losses Метод определения ориентации монокристаллов и калибровки энергии рентгеновских лучей при помощи спектра дифракционных потерь

  • Fine Structure of Diffraction Losses in Single-Crystal X-Ray Lenses

    by N. B. Klimova, A. A. Barannikov, M. N. Sorokovikov, D. A. Zverev, V. A. Yunkin, P. A. Prosekov, A. Yu. Seregin, A. E. Blagov, A. A. Snigirev

    Single-crystal planar compound refractive lenses under diffraction losses (glitches) conditions, when a part of radiation incident on an optical element diffracts from some set of atomic planes, have been investigated. A detailed experimental study using synchrotron radiation of the influence of glitches on the focal spot formed by lenses has been performed. An analysis of the data obtained showed that diffraction losses arise on different parts of the parabolic lens profile due to the refraction effect at radiation energies differing by a few electronvolts. As a result, the shape of the focused beam changes with a change in energy near the energy of the glitch.


  • Open Access

    Using diffraction losses of X-rays in a single crystal for determination of its lattice parameters as well as for monochromator calibration

    by Nataliya Klimova, Irina Snigireva, Anatoly Snigirev, Oleksandr Yefanov

    A way has been developed to measure the unit-cell parameters of a single crystal just from an energy scan with X-rays, even when the exact energy of the X-rays is not well defined due to an error in the pitch angle of the monochromator. The precision of this measurement reaches da/a ∼ 1 × 10−5. The method is based on the analysis of diffraction losses of the beam, transmitted through a single crystal (the so-called `glitch effect'). This method can be easily applied to any transmissive X-ray optical element made of single crystals (for example, X-ray lenses). The only requirements are the possibility to change the energy of the generated X-ray beam and some intensity monitor to measure the transmitted intensity. The method is agnostic to the error in the monochromator tuning and it can even be used for determination of the absolute pitch (or 2θ) angle of the monochromator. Applying the same method to a crystal with well known lattice parameters allows determination of the exact cell parameters of the monochromator at any energy.


  • Open Access

    Suppressing Diffraction-Related Intensity Losses in Transmissive Single-Crystal X-ray Optics

    by Nataliya Klimova, Irina Snigireva, Anatoly Snigirev, Oleksandr Yefanov

    The highest-quality X-ray optics can be made of single-crystal materials such as silicon, germanium, or, even better, diamond. Unfortunately, such X-ray optics have one drawback: diffraction losses or the “glitch effect”. This effect manifests itself as follows: at some energies of X-rays, the intensity of the transmitted beam drops due to the fact that some crystalline planes have satisfied the diffraction condition. Diffraction losses are usually observed in spectroscopic experiments when the energy of the X-rays changes in a certain range. However, this effect might also influence any experiment using X-rays, especially at higher energies. In this paper, we propose a method to overcome the glitch problem in transmissive optics. This is achieved using small rotations of the optical element. We describe the algorithm for “glitch-free” measurements in detail and the theory behind it.


  • Open Access

    Determination of the Exact Orientation of Single-Crystal X-ray Optics from Its Glitch Spectrum and Modeling of Glitches for an Arbitrary Configuration

    by Nataliya Klimova, Oleksandr Yefanov, Irina Snigireva, Anatoly Snigirev

    X-ray optics made of single-crystal materials are widely used at most of the X-ray sources due to the outstanding properties. The main drawback of such optics—the diffraction losses, also known as glitches of intensity in the energy spectrum of the transmitted/diffracted beam. To be able to handle this negative effect, one needs a reliable way to simulate the glitch spectrum in any configuration. Here, we demonstrate the way of precisely determining the crystallographic orientation and unit cell parameters of optical elements just from a small glitch spectrum with the consequent possibility of simulating glitches for any energy.


  • CRL-based ultra-compact transfocator for X-ray focusing and microscopy

    by Anton Narikovich, Maxim Polikarpov, Alexander Barannikov, Nataliya Klimova, Anatoly Lushnikov, Ivan Lyatun, Gleb Bourenkov, Dmitrii Zverev, Igor Panormov, Alexander Sinitsyn, et al.

    A new ultra-compact transfocator (UCTF) based on X-ray compound refractive lenses (CRLs) is presented. The device can be used to change the number of one- and two-dimensional focusing CRLs by moving the individual parabolic lenses one-by-one independently, thus providing permanent energy and focal-length tunability for scanning and full-field X-ray microscopy applications. The small overall size and light weight of the device allow it to be integrated in any synchrotron beamline, while even simplifying the experimental layout. The UCTF was tested at the Excillium MetalJet microfocus X-ray source and at the P14 EMBL (PETRA-III) beamline, demonstrating high mechanical stability and lens positioning repeatability.


  • Investigation of `glitches' in the energy spectrum induced by single-crystal diamond compound X-ray refractive lenses

    by Qiuyuan Zhang, Maxim Polikarpov, Nataliya Klimova, Helge B. Larsen, Ragnvald Mathiesen, Hermann Emerich, Gunnar Thorkildsen, Irina Snigireva, Anatoly Snigirev

    Single-crystal diamond stands out among all the candidate materials that could be exploited to fabricate compound refractive lenses (CRLs) owing to its extremely stable properties. Among all related experimental features, beam divergence, χ-angles relative to the incoming beam in Eulerian geometry and different positions of the X-ray beam relative to the lens geometry may influence the transmission energy spectrum of CRLs. In addition, the orientation of the single-crystal diamond sample may also affect the glitches significantly. To verify these initial assumptions, two experiments, an energy scan and an ω-scan, were set up by employing a polished diamond plate consisting of five biconcave lenses. The results show that beam divergence does not affect the spectrum, nor do χ-angles when ω is set to zero. Nevertheless, different incident positions have an appreciable effect on the transmission spectrum, in particular the `strengths' of the glitches. This is attributed to absorption. The ω-scan setup is capable of determining the so-called orientation matrix, which may be used to predict both `energy positions' and `strengths' of the glitches.


  • Open Access

    Mini-Transfocator for X-ray Focusing and Microscopy

    by A. Narikovich, A. Barannikov, P. Ershov, N. Klimova, A. Lushnikov, I. Lyatun, I. Panormov, M. Polikarpov, A. Sinitsyn, D. Zverev, et al.