Thomas Stoppe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas Stoppe has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Thomas Zahnert
Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Otorhinolaryngology, Dresden
4 shared publications- Edmund Koch
Clinical Sensoring and Monitoring, Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, TU Dresden, Dresden, Germany
3 shared publications - Jonas Golde
Fraunhofer Institute for Material and Beam Technology IWS, Dresden , Germany
3 shared publications - Lars Kirsten
Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Anesthesiology and Critical Care Medicine, Clinical Sensoring and Monitoring, Fetscherstraße 74, 01307 Dresden, Germany
3 shared publications Matthias Bornitz
Technische Universität Dresden, Carl Gustav Carus Faculty of Medicine, Otorhinolaryngology, Dresden
3 shared publications- Matthias Bornitz
Technische Univ. Dresden (Germany)
3 shared publications
Latest Publications
- Open Access
- 25 January 2021
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 20 (1) , e202000100
Simulation and Development of Biomimetic Electrospun PCL Nanofibrous Tympanic Membrane Implants
Electrospun membranes have a great potential in myringoplasty, as the special microstructure of fibers could be comparable to the fiber structure of the tympanic membrane (TM), thus, making it an potential implant for tympanic membrane reconstruction. In this work, the microscale parameters of the fiber structure were studied in a numerical homogenization procedure. The aim of the investigations was to obtain an implant that has a compromise between acoustic and mechanical properties and which at macroscale is comparable with the human TM. The numerical results were verified with experiments on first samples.
- 25 January 2021
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 20 (1) , e202000100
Open AccessSimulation and Development of Biomimetic Electrospun PCL Nanofibrous Tympanic Membrane Implants
Electrospun membranes have a great potential in myringoplasty, as the special microstructure of fibers could be comparable to the fiber structure of the tympanic membrane (TM), thus, making it an potential implant for tympanic membrane reconstruction. In this work, the microscale parameters of the fiber structure were studied in a numerical homogenization procedure. The aim of the investigations was to obtain an implant that has a compromise between acoustic and mechanical properties and which at macroscale is comparable with the human TM. The numerical results were verified with experiments on first samples.
- Open Access
- 1 May 2020
- Published by Georg Thieme Verlag KG
- Vol. 99 (S 02)
Schwingungseigenschaften von MEW PCL Scaffolds als biomimetischer Trommelfellersatz
Einführung Biopolymere können in feinen definierten Strukturen mit Tissue-Engineering-Technologien hergestellt werden. Es wurde untersucht, ob es mit Melt Electro Writing (MEW) möglich ist, Polycaprolacton (PCL) Scaffolds als funktionalen synthetischen menschlichen Trommelfellersatz herzustellen. Methode Es wurden Scaffolds mit unterschiedlichen Strukturparametern hergestellt. Fasern mit Durchmessern von 10 µm und 15 µm, sowie 150 µm und 250 µm Faserabstand, wurden in mehreren Schichten (4, 6 und 8), nebst verschiedenen Schicht-zu-Schicht Orientierungen (45°, 90°), gedruckt. So konnten Gesamtdicken von 40 µm bis 120 µm erzielt werden. Zusätzlich wurden Scaffolds mit Kollagen Typ I beschichtet. Schwingungsmessungen wurden mit einem multisinusförmigen Anregungssignal zwischen 100 Hz und 5 kHz und einem Laser-Doppler-Vibrometer durchgeführt. Ergebnisse Die Struktureigenschaften beeinflussten die Schwingungseigenschaften der Scaffolds. So führte beispielsweise eine Vergrößerung der Faserschichten bzw. der Faserdicke zu einer erhöhten Steifigkeit und einer entsprechenden Änderung der Schwingungseingeschaften. Für einen realistischen Vergleich zwischen den Scaffolds und menschlichen Trommelfellen beeinflusste vor allem die definierte Einspannungskraft im Prüfstand, im Vergleich zur natürlichen Aufhängung, die Ergebnisse. Für bestimmte Strukturparameter konnten die Schwingungseigenschaften menschlicher Trommelfelle erreicht werden. Die Schwingungsmagnitude der flachen Scaffolds war dabei in der Regel größer als beim menschlichen Trommelfell. Fazit Die Schwingungseigenschaften von MEW PCL-Gerüsten können durch die Änderung der MEW-Faserstruktur gesteuert werden. Dadurch können sie so aufgebaut werden, dass sie mit menschlichen Trommelfellmembranen vergleichbar sind. Poster-PDF A-1798.PDF Publication Date: 10 June 2020 (online) © . © Georg Thieme Verlag KG Stuttgart · New York
- 1 May 2020
- Published by Georg Thieme Verlag KG
- Vol. 99 (S 02)
Open AccessSchwingungseigenschaften von MEW PCL Scaffolds als biomimetischer Trommelfellersatz
Einführung Biopolymere können in feinen definierten Strukturen mit Tissue-Engineering-Technologien hergestellt werden. Es wurde untersucht, ob es mit Melt Electro Writing (MEW) möglich ist, Polycaprolacton (PCL) Scaffolds als funktionalen synthetischen menschlichen Trommelfellersatz herzustellen. Methode Es wurden Scaffolds mit unterschiedlichen Strukturparametern hergestellt. Fasern mit Durchmessern von 10 µm und 15 µm, sowie 150 µm und 250 µm Faserabstand, wurden in mehreren Schichten (4, 6 und 8), nebst verschiedenen Schicht-zu-Schicht Orientierungen (45°, 90°), gedruckt. So konnten Gesamtdicken von 40 µm bis 120 µm erzielt werden. Zusätzlich wurden Scaffolds mit Kollagen Typ I beschichtet. Schwingungsmessungen wurden mit einem multisinusförmigen Anregungssignal zwischen 100 Hz und 5 kHz und einem Laser-Doppler-Vibrometer durchgeführt. Ergebnisse Die Struktureigenschaften beeinflussten die Schwingungseigenschaften der Scaffolds. So führte beispielsweise eine Vergrößerung der Faserschichten bzw. der Faserdicke zu einer erhöhten Steifigkeit und einer entsprechenden Änderung der Schwingungseingeschaften. Für einen realistischen Vergleich zwischen den Scaffolds und menschlichen Trommelfellen beeinflusste vor allem die definierte Einspannungskraft im Prüfstand, im Vergleich zur natürlichen Aufhängung, die Ergebnisse. Für bestimmte Strukturparameter konnten die Schwingungseigenschaften menschlicher Trommelfelle erreicht werden. Die Schwingungsmagnitude der flachen Scaffolds war dabei in der Regel größer als beim menschlichen Trommelfell. Fazit Die Schwingungseigenschaften von MEW PCL-Gerüsten können durch die Änderung der MEW-Faserstruktur gesteuert werden. Dadurch können sie so aufgebaut werden, dass sie mit menschlichen Trommelfellmembranen vergleichbar sind. Poster-PDF A-1798.PDF Publication Date: 10 June 2020 (online) © . © Georg Thieme Verlag KG Stuttgart · New York
- Open Access
- 1 May 2020
- Published by Georg Thieme Verlag KG
- Vol. 99 (S 02)
Vibration properties of MEW PCL scaffolds as biomimetic tympanic membrane replacements
Introduction Synthetic materials like biopolymers can be fabricated in various shapes with different tissue engineering technologies. It was investigated, if it possible to utilize melt electro written (MEW) Polycaprolactone (PCL) scaffolds as a synthetic human tympanic membrane replacement. Method Scaffolds with different structural parameters, e.g. fibre diameter, amount of layers, orientation angle and strand distance, were fabricated. Fibres with diameters of 10 µm and 15 µm with different strand distances of 150 µm and 250 µm were printed in several layers (4, 6 and 8 layers) and in different layer-to-layer orientations (45°, 90°). Hence, scaffolds with thicknesses ranging from 40 µm to 120 µm were fabricated. Additionally, some scaffolds were infiltrated with collagen type I. They were excited with a multi-sinusoidal signal between 100 Hz and 5 kHz and measured with laser-Doppler vibrometry. Results and Discussion The vibration properties of the scaffolds varied, depending on the specific design. For example, an increase in fibre layers and fibre thickness led to an increased stiffness. Simply supported mounting was regarded as mostly appropriate, for a realistic comparison between the scaffolds and the human tympanic membrane in the test stand and in its native mounting. The vibration magnitude of the flat scaffolds was usually bigger than for the human tympanic membrane. Scaffolds with the same resonance frequency range as for tympanic membranes were successfully fabricated. Conclusion The vibration properties of MEW PCL scaffolds can be controlled by defining the MEW fibre structure. Thus, they can be setup to be comparable to human tympanic membranes. Poster-PDF A-1798.PDF Diese Maßnahme wird mitfinanziert mit Steuermitteln auf Grundlage des von den Abgeordneten des Sächsischen Landtags beschlossenen Haushaltes. Publication Date: 10 June 2020 (online) © . © Georg Thieme Verlag KG Stuttgart · New York
- 1 May 2020
- Published by Georg Thieme Verlag KG
- Vol. 99 (S 02)
Open AccessVibration properties of MEW PCL scaffolds as biomimetic tympanic membrane replacements
Introduction Synthetic materials like biopolymers can be fabricated in various shapes with different tissue engineering technologies. It was investigated, if it possible to utilize melt electro written (MEW) Polycaprolactone (PCL) scaffolds as a synthetic human tympanic membrane replacement. Method Scaffolds with different structural parameters, e.g. fibre diameter, amount of layers, orientation angle and strand distance, were fabricated. Fibres with diameters of 10 µm and 15 µm with different strand distances of 150 µm and 250 µm were printed in several layers (4, 6 and 8 layers) and in different layer-to-layer orientations (45°, 90°). Hence, scaffolds with thicknesses ranging from 40 µm to 120 µm were fabricated. Additionally, some scaffolds were infiltrated with collagen type I. They were excited with a multi-sinusoidal signal between 100 Hz and 5 kHz and measured with laser-Doppler vibrometry. Results and Discussion The vibration properties of the scaffolds varied, depending on the specific design. For example, an increase in fibre layers and fibre thickness led to an increased stiffness. Simply supported mounting was regarded as mostly appropriate, for a realistic comparison between the scaffolds and the human tympanic membrane in the test stand and in its native mounting. The vibration magnitude of the flat scaffolds was usually bigger than for the human tympanic membrane. Scaffolds with the same resonance frequency range as for tympanic membranes were successfully fabricated. Conclusion The vibration properties of MEW PCL scaffolds can be controlled by defining the MEW fibre structure. Thus, they can be setup to be comparable to human tympanic membranes. Poster-PDF A-1798.PDF Diese Maßnahme wird mitfinanziert mit Steuermitteln auf Grundlage des von den Abgeordneten des Sächsischen Landtags beschlossenen Haushaltes. Publication Date: 10 June 2020 (online) © . © Georg Thieme Verlag KG Stuttgart · New York
- 1 July 2018
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 39 (6) , 739-747
Function, Applicability, and Properties of a Novel Flexible Total Ossicular Replacement Prosthesis With a Silicone Coated Ball and Socket Joint
Hypothesis:A total ossicular replacement prosthesis (TORP) with a silicone coated ball and socket joint (BSJ) is able to compensate pressure changes and therefore provide better sound transmission compared with rigid prostheses.Background:Dislocation and extrusion are known complications after TORP reconstruction, leading to revisions and recurrent hearing loss. Poor aeration of the middle ear, scar tension, and static pressure variations in conjunction with rigid prosthesis design causes high tension at the implant coupling points.Methods:A novel TORP prototype with a silicone coated BSJ has been developed. Experimental measurements were performed on nine fresh cadaveric human temporal bones of which five were used for a comparison between rigid TORP and flexible TORP tympanoplasty. The middle ear transfer function was measured at ambient pressure and at 2.5kPa, both positive and negative pressure, applied in the ear canal.Results:The flexible TORP design yields a better transmission of sound after implantation and at negative pressure inside the tympanic cavity, compared with rigid TORP. In average, it provides an equivalent sound transfer like the intact middle ear. At positive pressure, the flexible TORP performs slightly worse. Both performed worse than the intact middle ear, which is related to an uplifting of the prostheses.Conclusion:The findings may be considered preliminary as this experimental study was limited to just one of the many different possible situations of tympanoplasty and it involved a small sample size. Nevertheless, the results with the flexible TORP were promising and could encourage further investigations on such prostheses.
- 1 July 2018
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 39 (6) , 739-747
Function, Applicability, and Properties of a Novel Flexible Total Ossicular Replacement Prosthesis With a Silicone Coated Ball and Socket Joint
Hypothesis:A total ossicular replacement prosthesis (TORP) with a silicone coated ball and socket joint (BSJ) is able to compensate pressure changes and therefore provide better sound transmission compared with rigid prostheses.Background:Dislocation and extrusion are known complications after TORP reconstruction, leading to revisions and recurrent hearing loss. Poor aeration of the middle ear, scar tension, and static pressure variations in conjunction with rigid prosthesis design causes high tension at the implant coupling points.Methods:A novel TORP prototype with a silicone coated BSJ has been developed. Experimental measurements were performed on nine fresh cadaveric human temporal bones of which five were used for a comparison between rigid TORP and flexible TORP tympanoplasty. The middle ear transfer function was measured at ambient pressure and at 2.5kPa, both positive and negative pressure, applied in the ear canal.Results:The flexible TORP design yields a better transmission of sound after implantation and at negative pressure inside the tympanic cavity, compared with rigid TORP. In average, it provides an equivalent sound transfer like the intact middle ear. At positive pressure, the flexible TORP performs slightly worse. Both performed worse than the intact middle ear, which is related to an uplifting of the prostheses.Conclusion:The findings may be considered preliminary as this experimental study was limited to just one of the many different possible situations of tympanoplasty and it involved a small sample size. Nevertheless, the results with the flexible TORP were promising and could encourage further investigations on such prostheses.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 99-101
Functional and morphological imaging of the human tympanic membrane with endoscopic optical coherence tomography
In this ex vivo feasibility study, endoscopic structural and functional optical coherence tomography (OCT) imaging with a field of view of 8 mm is presented allowing the inspection of nearly the entire tympanic membrane through the ear canal. The endoscope utilizes a gradient index optics for simultaneous OCT and video endoscopy. Additionally, Doppler-OCT allows the measurement of the tympanic membrane oscillation. Due to the fast image acquisition, only minor motion artifacts have been observed, which don’t affect the image quality. In conclusion, endoscopic OCT is considered as a promising tool for the comprehensive examination of the human middle ear.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 99-101
Open AccessFunctional and morphological imaging of the human tympanic membrane with endoscopic optical coherence tomography
In this ex vivo feasibility study, endoscopic structural and functional optical coherence tomography (OCT) imaging with a field of view of 8 mm is presented allowing the inspection of nearly the entire tympanic membrane through the ear canal. The endoscope utilizes a gradient index optics for simultaneous OCT and video endoscopy. Additionally, Doppler-OCT allows the measurement of the tympanic membrane oscillation. Due to the fast image acquisition, only minor motion artifacts have been observed, which don’t affect the image quality. In conclusion, endoscopic OCT is considered as a promising tool for the comprehensive examination of the human middle ear.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 143-146
Middle ear reconstruction with a flexible prosthesis
The middle ear plays a crucial role in the quality of hearing. This complex construct performs different tasks like the protection against large air pressure input, the transmission of sound and its adaption to the inner ear impedance. Traumas, erosion by chronic otitis media or cholesteatoma, as well as other degenerative or damaging diseases, are reasons for a necessary reconstruction of specific middle ear structures. The reconstruction of the ossicular chain is very often performed by using rigid ossicular replacement prostheses made out of titanium, ceramics or bone. Tilting and dislocation of these passive implants are some of the known complications after middle ear surgery. They are related to loads at the implant coupling points in response to a tension change in the middle ear. The healing process, scar tension and ventilation problems are possible causes.To increase the sound transmission quality of total reconstructions and safety in case of pressure dependent movement of the tympanic membrane, a novel flexible total ossicular replacement prosthesis (TORP) with a silicone coated ball joint prototype was developed and investigated. Besides measurements of first middle ear transfer functions of temporal bones, the mechanical properties of the flexible TORP were examined with stress relaxation investigations.The novel silicone coated ball and socket joint TORP provides a sound transfer equivalent to the intact human middle ear at normal pressure and negative pressure in the middle ear. Together with the low stiffness values at an anatomically typical deflection of about 500 μm the prevention of a stiffening of the stapes annular ligament could be approved. Thus, improved acoustic transmission quality and reconstruction stability in comparison to common rigid titanium TORP could be determined. Nevertheless, further design improvements should be accomplished. The demonstrated flexible TORP can solve some common problems in middle ear reconstruction.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 143-146
Open AccessMiddle ear reconstruction with a flexible prosthesis
The middle ear plays a crucial role in the quality of hearing. This complex construct performs different tasks like the protection against large air pressure input, the transmission of sound and its adaption to the inner ear impedance. Traumas, erosion by chronic otitis media or cholesteatoma, as well as other degenerative or damaging diseases, are reasons for a necessary reconstruction of specific middle ear structures. The reconstruction of the ossicular chain is very often performed by using rigid ossicular replacement prostheses made out of titanium, ceramics or bone. Tilting and dislocation of these passive implants are some of the known complications after middle ear surgery. They are related to loads at the implant coupling points in response to a tension change in the middle ear. The healing process, scar tension and ventilation problems are possible causes.To increase the sound transmission quality of total reconstructions and safety in case of pressure dependent movement of the tympanic membrane, a novel flexible total ossicular replacement prosthesis (TORP) with a silicone coated ball joint prototype was developed and investigated. Besides measurements of first middle ear transfer functions of temporal bones, the mechanical properties of the flexible TORP were examined with stress relaxation investigations.The novel silicone coated ball and socket joint TORP provides a sound transfer equivalent to the intact human middle ear at normal pressure and negative pressure in the middle ear. Together with the low stiffness values at an anatomically typical deflection of about 500 μm the prevention of a stiffening of the stapes annular ligament could be approved. Thus, improved acoustic transmission quality and reconstruction stability in comparison to common rigid titanium TORP could be determined. Nevertheless, further design improvements should be accomplished. The demonstrated flexible TORP can solve some common problems in middle ear reconstruction.
- 1 October 2016
- Published by Elsevier in Hearing Research
- Vol. 340, 169-178
Fully implantable hearing aid in the incudostapedial joint gap
- 1 October 2016
- Published by Elsevier in Hearing Research
- Vol. 340, 169-178
Fully implantable hearing aid in the incudostapedial joint gap
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 443-447
Doppler optical coherence tomography as a promising tool for detecting fluid in the human middle ear
The treatment of otitis media requires classifying the effusion in the tympanic cavity for choosing appropriate therapeutic strategies. Otoscopic examination of the middle ear depends on the expertise of the physician and is often hampered in case of inflammatory alterations of the tympanic membrane. In otologic research, optical coherence tomography is an innovative non-invasive imaging technique utilized for visualizing the tympanic membrane. This ex vivo study presents the possibility of OCT and Doppler-OCT for the detection of effusions in the tympanic cavity. Structural OCT imaging allows the direct visualization of scattering fluids behind the tympanic membrane. In addition, the measurement of the reduced oscillation amplitude by means of Doppler-OCT permits the indirect detection of scattering and transparent fluids.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 443-447
Open AccessDoppler optical coherence tomography as a promising tool for detecting fluid in the human middle ear
The treatment of otitis media requires classifying the effusion in the tympanic cavity for choosing appropriate therapeutic strategies. Otoscopic examination of the middle ear depends on the expertise of the physician and is often hampered in case of inflammatory alterations of the tympanic membrane. In otologic research, optical coherence tomography is an innovative non-invasive imaging technique utilized for visualizing the tympanic membrane. This ex vivo study presents the possibility of OCT and Doppler-OCT for the detection of effusions in the tympanic cavity. Structural OCT imaging allows the direct visualization of scattering fluids behind the tympanic membrane. In addition, the measurement of the reduced oscillation amplitude by means of Doppler-OCT permits the indirect detection of scattering and transparent fluids.
- 1 September 2015
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Additional Conferences (Device Packaging, Hitec, Hiten, & Cicmt)
- Vol. 2015 (CICMT) , 000144-000148
Simulation of the working range of an implantable hearing aid transducer by use of different piezoelectric materials
A piezoelectric membrane transducer which offers an approach to treat sensorineural hearing loss is introduced. The sensor and the actuator element each consist of a titanium membrane with a single crystal piezo and are clamped into the same assembly housing. The transducer is placed into the incudostapedial joint gap (between incus and stapes ossicle) which offers a straightforward implantation after the drilling of an access through a mastoidectomy which is state of the art for otology surgeries. The sensor is measuring the force transmitted through the ossicular chain onto his membrane on the incus-side of the housing. An associated signal processing drives the actuator at the opposite side of the sensor to amplify the movement transmitted by the ossicular chain to the inner ear. The movement of the stapes footplate is related to the hearing perception. Therefore the proposed concept can be used as part of a fully implantable hearing aid. A finite elemente model (FEM) of a transducer is built and implemented in a existing FEM model of the middle ear. Both sensor and actuator performance span up a working range for the transducer which ranges from about 20 to 30 dB SPL up to 90 to over 120 dB SPL. In this study the range of the workspace is evaluated in dependency of the chosen piezoelectric material which can lead to significant changes of the results.
- 1 September 2015
- Published by IMAPS - International Microelectronics Assembly and Packaging Society in Additional Conferences (Device Packaging, Hitec, Hiten, & Cicmt)
- Vol. 2015 (CICMT) , 000144-000148
Simulation of the working range of an implantable hearing aid transducer by use of different piezoelectric materials
A piezoelectric membrane transducer which offers an approach to treat sensorineural hearing loss is introduced. The sensor and the actuator element each consist of a titanium membrane with a single crystal piezo and are clamped into the same assembly housing. The transducer is placed into the incudostapedial joint gap (between incus and stapes ossicle) which offers a straightforward implantation after the drilling of an access through a mastoidectomy which is state of the art for otology surgeries. The sensor is measuring the force transmitted through the ossicular chain onto his membrane on the incus-side of the housing. An associated signal processing drives the actuator at the opposite side of the sensor to amplify the movement transmitted by the ossicular chain to the inner ear. The movement of the stapes footplate is related to the hearing perception. Therefore the proposed concept can be used as part of a fully implantable hearing aid. A finite elemente model (FEM) of a transducer is built and implemented in a existing FEM model of the middle ear. Both sensor and actuator performance span up a working range for the transducer which ranges from about 20 to 30 dB SPL up to 90 to over 120 dB SPL. In this study the range of the workspace is evaluated in dependency of the chosen piezoelectric material which can lead to significant changes of the results.
- 9 July 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9541, 95410R
Imaging the tympanic membrane oscillation ex vivo with Doppler optical coherence tomography during simulated Eustachian catarrh
Recently, optical coherence tomography (OCT) was utilized in multiple studies for structural and functional imaging of the middle ear and the tympanic membrane. Since Doppler OCT allows both, the spatially resolved measurement of the tympanic membrane oscillation and high-resolution imaging, it is regarded as a promising tool for future in vivo applications. In this study, Doppler OCT is utilized for the visualization of the tympanic membrane oscillation in temporal bones with simulated Eustachian catarrh, which was realized by generating a depression in the tympanic cavity. The transfer function, meaning the oscillation amplitude normalized to the applied sound pressure, is measured frequency resolved in the range from 0.5 kHz to 6 kHz and with a lateral spatial resolution of 0.4 mm. Typical oscillation patterns could be observed in case of ambient pressure in the tympanic cavity. Under depression the characteristic oscillation patterns were observed with widely congruent appearance but at higher frequencies.
- 9 July 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9541, 95410R
Imaging the tympanic membrane oscillation ex vivo with Doppler optical coherence tomography during simulated Eustachian catarrh
Recently, optical coherence tomography (OCT) was utilized in multiple studies for structural and functional imaging of the middle ear and the tympanic membrane. Since Doppler OCT allows both, the spatially resolved measurement of the tympanic membrane oscillation and high-resolution imaging, it is regarded as a promising tool for future in vivo applications. In this study, Doppler OCT is utilized for the visualization of the tympanic membrane oscillation in temporal bones with simulated Eustachian catarrh, which was realized by generating a depression in the tympanic cavity. The transfer function, meaning the oscillation amplitude normalized to the applied sound pressure, is measured frequency resolved in the range from 0.5 kHz to 6 kHz and with a lateral spatial resolution of 0.4 mm. Typical oscillation patterns could be observed in case of ambient pressure in the tympanic cavity. Under depression the characteristic oscillation patterns were observed with widely congruent appearance but at higher frequencies.