KKKonstantinos Kopsidas

Konstantinos Kopsidas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Konstantinos Kopsidas has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Review of Hydrophobicity Measurement and Classification Methods for High‐Voltage Insulators

    by Christos Zachariades, Salihu Salisu, Aliyu Abubakar, Konstantinos Kopsidas

    Hydrophobicity is a critical property influencing the performance and reliability of high‐voltage insulators, particularly nonceramic types, by mitigating surface contamination and reducing the risk of flashover. This paper presents a comprehensive review of hydrophobicity assessment techniques, spanning traditional laboratory‐based techniques, alternative experimental approaches, and modern artificial intelligence (AI)–assisted systems. Standard methods such as the contact angle, surface tension, and spray techniques are evaluated for their accuracy and limitations in field deployment. Alternative methods, including salt fog and dynamic drop tests, offer enhanced insights but remain constrained by laboratory requirements. The review emphasizes the rapid evolution of AI‐driven techniques, ranging from image processing and pattern recognition to deep learning models such as convolutional neural networks (CNNs) and vision transformers (ViTs), which enable scalable, automated, and objective surface condition categorization. Despite their promise, these methods face challenges related to image quality, environmental variability, and computational demands. To address these, the paper proposes a structured framework for developing a robust machine learning model tailored for hydrophobicity classification. The framework outlines key stages including data acquisition, model architecture, training strategies, evaluation metrics, and deployment considerations, with a focus on real‐time, field‐ready applications. This review not only synthesizes the current state of the art but also provides a roadmap for future research and standardization efforts aimed at integrating AI‐based solutions into practical insulator condition monitoring.

  • The Influence of Local Thermodynamic Equilibrium State on the Composition Characteristic of the Discharge on Overhead Line—Part I: Partial Arc of the Insulator

    by Wei Meng, Jiayu Li, Steven Qi Li, Konstantinos Kopsidas, Jianlin Hu, Vladimir Terzija, Xingliang Jiang, Zijia Wang

    Partial arcs, spark discharges, and other destructive gaseous discharges frequently occur on overhead line, leading to insulation failure and power outages. Particle composition, as a fundamental parameter, governs discharge characteristics. This study focuses on partial arcs on the insulator-grading ring gap by analyzing rod-plane gap arc discharges under AC/DC voltage through emission spectroscopy. Characteristic species and reactions of arc are identified to construct a two-temperature discharge composition model. To address the model’s strong nonlinearity, a dimensional reduction approach combined with an advanced iterative algorithm is proposed. Numerical validation demonstrates that dimensional reduction compresses variables to the number of elemental species, while the new algorithm achieves a twelvefold speed improvement over conventional Newton iteration with comparable accuracy. Equilibrium analysis reveals that increasing the parameter θT yields a non-monotonic ionization effect: electron density rises and then falls (inverse U-shaped profile), whereas neutral particle density decreases monotonically. These findings provide valuable reference data for discharge parameter calculations in insulation coordination and fundamental plasma modeling. The proposed numerical methods further offer efficient tools for investigating discharge physics in overhead line engineering.

  • The Influence of Local Thermodynamic Equilibrium State on the Composition Characteristic of the Discharge on Overhead Line—Part II: The Arc Under the Polluted Icing Condition

    by Wei Meng, Jiayu Li, Steven Qi Li, Konstantinos Kopsidas, Jianlin Hu, Vladimir Terzija, Xingliang Jiang, Zijia Wang

    Partial arcs, a form of destructive gas discharge occurring on ice-covered electric apparatus (including insulators, bushings, and conductors, etc.), pose significant risks of flashover accidents and potential power outages. As particle composition characteristics represent a fundamental physical property critical for arc discharge modeling and insulation design, this study investigates these characteristics under icing conditions through combined spectrographic experiments and numerical simulations, with particular emphasis on analyzing the influence of the arc’s non-local thermodynamic equilibrium (non-LTE) state. To overcome the nonlinearity challenges in determining initial values for newly introduced particles under icing and soluble contamination conditions, this paper developed a novel composition perturbation iterative method accompanied by a specialized algorithm. This paper’s findings demonstrate nonlinear behavior in 11 particle species across varying contamination mole ratios, revealing that while increased non-LTE states initially enhance ionization reactions before subsequently inhibiting them, they consistently promote dissociation reactions. Furthermore, elevated non-LTE states reduce the required gas temperature for electrons and negative ions to achieve peak densities. The insights gained from this research provide fundamental references for arc modeling, insulation coordination, and further investigations into the physical properties of arcs on ice-covered electric apparatus, while the proposed numerical methods offer an effective solution for addressing initial value problems in high-voltage engineering when dealing with novel electrical dielectrics.

  • Open Access

    Thermal Characteristics of Trapezoidal Overhead Conductors Exposed to Galvanic Corrosion

    by Mohamad Izzat Nawawi, Shahnurriman Abdul Rahman, Muhammad Mokhzaini Azizan, Konstantinos Kopsidas

    The ampacity of overhead conductors is primarily determined by their thermal characteristics. However, current ampacity techniques assume that conductors are in an uncorroded state, a simplification that fails to account for the effects of corrosion. This oversight can lead to elevated operating temperatures in corroded conductors, potentially violating ground clearance requirements, reducing service life, and increasing public safety risks. This study utilizes COMSOL Multiphysics software to model the development of galvanic corrosion on Aluminum Conductor Steel Reinforced (ACSR) conductors with trapezoidal wires, which are commonly used in corrosive environments. Subsequently, the study applies heat transfer modelling to examine the thermal characteristics of these corroded conductors. The findings reveal that galvanic corrosion leads to a loss of conductive area in the aluminum strands, which reduces the overall conductive capacity. Under predefined ampacity conditions, this reduction causes increased temperatures at the core-aluminum interface for ACSR/TW conductors, leading to higher overall conductor temperatures. The reductions in the conductive area for Santee/TW, Martin/TW, and Hawk/TW ACSR are 4%, 8%, and 11%, respectively, resulting in temperature increases of 3°C, 4.4°C, and 5.5°C. These results highlight for the importance of considering corrosion on the ampacity determination.

  • Effect of Coatings on the Audible Noise of DC Corona Discharge and Its Mechanism

    by Yanzhou Li, Qi Li, Jiayu Li, Tianxiang Ren, Yigui Li, Sheng Xia, Konstantinos Kopsidas, Jianlin Hu, Xingliang Jiang

    The rapid development of ultra-high voltage (UHV) transmission technology is playing key role in achieving China’s goal of ’carbon neutrality’. Audible noise (AN) from transmission lines is gradually becoming one of the key concerns for OHL design. This article investigates AN emission under rainy and fogy conditions, when water droplets form on the surface of the overhead line (OHL) conductors which maximises the corona discharges. The experimental results have shown that the sound pressure level (SPL) varies significantly between positive and negative polarity. For the tested conductor sample, both hydrophilic and hydrophobic coatings suppress its corona discharge and AN level, in which the superhydrophilic coating achieved the best SPL reduction compared to the superhydrophobic coating and hydrophobic coating. The relationship between corona current and AN is further studied from the cage experiment. A model is proposed to estimate the SPL using corona current values. The calculation results show that the SPL of AN is approximately logarithmic function of corona current, and the verification test results show that the calculation error of the model in this paper is between 2-3%, which verifies the accuracy of the proposed method.


  • A Power System Reliability Framework Considering Soil Drying-Out Effect on Underground Cables

    by Keyi Wang, Konstantinos Kopsidas

    New cable installations are used to expand the power network's transmission capacity. Considering only fundamental cable design aspects and very conservative ratings can often lead to incorrect network reliability assessments while limiting asset's capacity and network transmission flexibility. Additional cable design aspects should be considered to improve network modeling with underground cables and utilize their thermal inertia contribution toward network flexibility and reliability. This work advances existing long-term network planning tools by aggregating cables’ rating model, soil drying-out properties, and a novel cable high-loading risk model into a Sequential Monte-Carlo method. These modeling additions allow the design of indices that quantify cables’ thermal inertia and thermal aging risks. Consequently, the proposed methodology can help utilities quantify benefits and costs from improved design measures to mitigate soil drying-out and identify appropriate backfill materials depending on a cost-benefit analysis. A modified IEEE 14-bus network is used to quantify the risks of soil drying-out effects on operational network security and the benefits of utilizing emergency rating as a flexibility measure. Results show emergency ratings could reduce EENS by ≈90%. However, increased cable aging risk is expected under unfavorable drying-out soil conditions. This is significantly reduced with the use of backfill materials.


  • Advancing OHL Rating Calculations: Modeling Mixed-Convective Cooling and Conductor Geometry

    by Konstantinos Kopsidas, Shahnurriman Abdul Rahman, Mohammed Abdulaziz AlAqil, Stefano Rolfo

    The existing standard current-temperature calculations for overhead line (OHL) conductors have been adequate for conventional conductors and their operating temperatures. However, these calculations make assumptions and include simplifications about conductor geometry and aero-thermal-dynamics, introducing an error in the High-Temperature Low-Sag conductors operating temperatures. To quantify the error introduced by the shape of strands, the paper employs a Multi-Physics Finite Element Modeling approach that calculates the conjugate heat transfer for trapezoidal stranded OHL conductors. Furthermore, it proposes corrective equations to improve the accuracy of existing methods. The equations incorporate a new Nusselt number correlation for mixed convection and capture the surface area ignored by current calculations. The outer conductor geometry assumptions and the combined natural and forced convective cooling omission in the IEEE and CIGRE methods introduce an error at low (below 0.12 m/s) cross-flow wind speeds suggesting an underestimation of conductor temperature by up to 4%. In medium wind speeds, typically at 0.5 m/s–0.61 m/s, the standard methods overestimate the conductor temperature limiting its current-carrying capability. A 5% uprating for existing OHLs is potentially feasible, particularly for the trapezoidal stranded conductors, when removing the assumptions made in existing methods.


  • Evaluating Aeolian Vibration Performance of High-Temperature Low-Sag OHL Conductors

    by K. Kopsidas, M. A. Al Aqil, A. Haldar, T. Kavanagh

    High-Temperature Low-Sag (HTLS) conductor technologies are often implemented, among many approaches, for optimizing the overhead lines’ utilization. The advancements of HTLS conductors are based on the differences in core and aluminum properties and installation procedures. This non-linear conductor behavior, although considered in the sag-tension calculations, by implementing the knee-point temperature, is often omitted from the aeolian vibration calculations. To understand the implications of the complex HTLS conductor structure on vibrations, a new calculation approach is proposed in this paper to quantify the effect of installation and operating conditions on the performance of any HTLS conductor. The proposed method conceives a prediction lay area that estimates where the actual field data are expected to lay and is validated with good accuracy against the field data from ACSR, ACCC, and GZTACSR. The developed model enables the prediction of non-homogeneous (composite) conductors and should be implemented at above knee-point operating temperatures with zero aluminum tensions.