Haibao Mu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Haibao Mu has a total of 183 co-authors. Here are the top co-authors by number of shared publications:
- Guanjun Zhang
Xi’an Jiaotong University
31 shared publications Guanjun Zhang
10 shared publications- Huanmin Yao
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
9 shared publications Huanmin Yao
8 shared publications- Xingyu Zou
School of Electrical Engineering and the State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
8 shared publications - Daning Zhang
Xi’an Jiaotong University
7 shared publications
Latest Publications
- Open Access
A Study on a Physically Guided Multi-Band Attention CNN-SNN Method for Photovoltaic Direct Current Arc Detection in Complex Environments
As photovoltaic installed capacity continues increasing, DC arc faults have become a major threat to the safe operation of the system. However, the impact of complex environmental factors (temperature, humidity, and dust) on arc characteristics remains unclear, leading to false positives and missed detections in existing detection methods across different scenarios. In this study, a photovoltaic arc simulation experimental platform capable of integrating multiple environmental parameters was established to collect arc voltage and current waveforms under various environmental conditions. Frequency-domain analysis results indicate that high temperatures significantly extend the high-frequency components to above 50 kHz, humidity has a non-monotonic effect on spectral energy, and dust induces a marked increase in energy in the mid-frequency range. Based on the above, this study proposes a physically guided multi-band attention convolutional spiking neural network (CNN-SNN) for DC arc detection. The results show that this model has excellent recognition capabilities for environmental arcs; in generalization tests excluding high-temperature, high-humidity, and heavy-dust operating conditions, the recall rates reached 95.49%, 98.5%, and 99.25%, respectively, after threshold adjustment; furthermore, the distribution of attention weights aligns with physical laws, and frequency-band masking experiments validated the necessity of complementary multi-frequency band information. This method significantly enhances the robustness of arc detection in complex environments while ensuring model compactness and interpretability.
Open AccessA Study on a Physically Guided Multi-Band Attention CNN-SNN Method for Photovoltaic Direct Current Arc Detection in Complex Environments
As photovoltaic installed capacity continues increasing, DC arc faults have become a major threat to the safe operation of the system. However, the impact of complex environmental factors (temperature, humidity, and dust) on arc characteristics remains unclear, leading to false positives and missed detections in existing detection methods across different scenarios. In this study, a photovoltaic arc simulation experimental platform capable of integrating multiple environmental parameters was established to collect arc voltage and current waveforms under various environmental conditions. Frequency-domain analysis results indicate that high temperatures significantly extend the high-frequency components to above 50 kHz, humidity has a non-monotonic effect on spectral energy, and dust induces a marked increase in energy in the mid-frequency range. Based on the above, this study proposes a physically guided multi-band attention convolutional spiking neural network (CNN-SNN) for DC arc detection. The results show that this model has excellent recognition capabilities for environmental arcs; in generalization tests excluding high-temperature, high-humidity, and heavy-dust operating conditions, the recall rates reached 95.49%, 98.5%, and 99.25%, respectively, after threshold adjustment; furthermore, the distribution of attention weights aligns with physical laws, and frequency-band masking experiments validated the necessity of complementary multi-frequency band information. This method significantly enhances the robustness of arc detection in complex environments while ensuring model compactness and interpretability.
- Open Access
- 27 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3860
Field-Measurement-Based Wideband Modeling and System-Level Simulation of MMC-HVDC Converter Stations for High-Frequency Disturbance Studies
This study establishes a field-measurement-based wideband modeling and station-level simulation framework for conducted high-frequency (HF) disturbance studies in modular multilevel converter-based high-voltage direct-current (MMC-HVDC) stations. Full-scale engineering-site frequency-response measurements are used to identify kHz-to-MHz terminal models of the arm reactor and the valve-side winding of the converter transformer. The arm reactor is fitted in the admittance domain by vector fitting and synthesized as a passive parallel network containing the main inductive path and multiple damped resistor–inductor–capacitor (RLC) branches. The transformer valve-side winding is represented by a Foster I/II hybrid -type terminal network reconstructed from two single-phase port-impedance measurements. The validated equipment models are integrated into a representative Power Systems Computer-Aided Design (PSCAD) station model. A 2 ms valve-side source sequence, constructed from nearest-level-control switching instants and a parameterized switching-transient template, is applied in paired injection and zero-injection simulations. For the representative event, the source peak is 605.6 V. Over the first 4 s, the arm-reactor terminal reaches 972.6 V, while the direct-current (DC)-side, valve-side alternating-current (AC), and point-of-common-coupling (PCC) responses reach 534.2, 438.4, and 151.9 V, respectively. The corresponding peak changes relative to the source are , , , and dB. The DC-side response contains a dominant damped oscillation near 0.61 MHz, and the AC/PCC transfer varies markedly across 0.2–2.0 MHz. In a separate control-identical comparison over the first 2.5 s, the field-identified and lumped models give DC-side peaks of 171.9 and 1.23 V and PCC peaks of 121.4 and 3.93 V under the same excitation. The framework connects field-identified equipment terminal behavior with station-level time-domain propagation analysis and provides a modeling basis for broadband resonance screening and conducted electromagnetic-interference (EMI) assessment.- 27 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3860
Open AccessField-Measurement-Based Wideband Modeling and System-Level Simulation of MMC-HVDC Converter Stations for High-Frequency Disturbance Studies
This study establishes a field-measurement-based wideband modeling and station-level simulation framework for conducted high-frequency (HF) disturbance studies in modular multilevel converter-based high-voltage direct-current (MMC-HVDC) stations. Full-scale engineering-site frequency-response measurements are used to identify kHz-to-MHz terminal models of the arm reactor and the valve-side winding of the converter transformer. The arm reactor is fitted in the admittance domain by vector fitting and synthesized as a passive parallel network containing the main inductive path and multiple damped resistor–inductor–capacitor (RLC) branches. The transformer valve-side winding is represented by a Foster I/II hybrid -type terminal network reconstructed from two single-phase port-impedance measurements. The validated equipment models are integrated into a representative Power Systems Computer-Aided Design (PSCAD) station model. A 2 ms valve-side source sequence, constructed from nearest-level-control switching instants and a parameterized switching-transient template, is applied in paired injection and zero-injection simulations. For the representative event, the source peak is 605.6 V. Over the first 4 s, the arm-reactor terminal reaches 972.6 V, while the direct-current (DC)-side, valve-side alternating-current (AC), and point-of-common-coupling (PCC) responses reach 534.2, 438.4, and 151.9 V, respectively. The corresponding peak changes relative to the source are , , , and dB. The DC-side response contains a dominant damped oscillation near 0.61 MHz, and the AC/PCC transfer varies markedly across 0.2–2.0 MHz. In a separate control-identical comparison over the first 2.5 s, the field-identified and lumped models give DC-side peaks of 171.9 and 1.23 V and PCC peaks of 121.4 and 3.93 V under the same excitation. The framework connects field-identified equipment terminal behavior with station-level time-domain propagation analysis and provides a modeling basis for broadband resonance screening and conducted electromagnetic-interference (EMI) assessment. - 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Cable Defect Location and Evaulation Based on Stepped-Frequency Waveform Reflectometry and Assisted Digital Twin Technology
The travelling wave reflection method is widely used to detect cable defects in modern industrial systems due to its non-destructive nature and high efficiency. However, the overlapping echoes of the defect with short length will result in inaccurate defect evaluation. In view of this, this paper proposes a novel cable defect diagnosis method based on stepped-frequency waveform reflectometry (SFWR) and assisted digital twin technology. First, the frequency response functions (FRFs) of two typical defects: point-like defect and line-like defect are constructed, and the limitations of line loss compensation for evaluating the short line-like defect is analysed. Then, a distinction method based on polarity interval is proposed to determine whether defect echoes exhibit overlapping. Finally, the assisted digital twin technology is used to separate defect overlapping echoes, ensuring the accuracy of defect evaluation. Simulations and experiments show that the method proposed in this paper exhibits good performance in evaluating the line-like defect with short length.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Cable Defect Location and Evaulation Based on Stepped-Frequency Waveform Reflectometry and Assisted Digital Twin Technology
The travelling wave reflection method is widely used to detect cable defects in modern industrial systems due to its non-destructive nature and high efficiency. However, the overlapping echoes of the defect with short length will result in inaccurate defect evaluation. In view of this, this paper proposes a novel cable defect diagnosis method based on stepped-frequency waveform reflectometry (SFWR) and assisted digital twin technology. First, the frequency response functions (FRFs) of two typical defects: point-like defect and line-like defect are constructed, and the limitations of line loss compensation for evaluating the short line-like defect is analysed. Then, a distinction method based on polarity interval is proposed to determine whether defect echoes exhibit overlapping. Finally, the assisted digital twin technology is used to separate defect overlapping echoes, ensuring the accuracy of defect evaluation. Simulations and experiments show that the method proposed in this paper exhibits good performance in evaluating the line-like defect with short length.
- Open Access
- 10 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 751
Analysis and Adaptive Separation of IGBT Switching Noise in PD Monitoring of Flexible HVDC Valves: An Evolutionary Perspective
The high-frequency switching noise of insulated-gate bipolar transistors (IGBTs) limits the sensitivity of online partial discharge (PD) monitoring in ultra-high-voltage flexible DC (VSC-HVDC) transmission systems. To address this challenge, this study investigates the underlying mechanisms and evolution of this interference and develops an anti-interference signal separation method. Simulation and experimental results indicate that the energy of IGBT switching noise is concentrated in the 30–180 MHz range, which significantly overlaps with the ultra-high-frequency (UHF) band used for PD detection. This research further reveals the pronounced modulation effect of device aging on the interference spectrum: bond wire aging triggers “spectral reconstruction” via altered parasitic parameters, where severe collector aging leads to an abnormal surge in turn-off interference amplitude. In contrast, gate oxide layer degradation manifests as characteristic “global spectrum attenuation” and a shift in peak frequency toward lower bands. Confronted with the challenges of strong interference and spectrum drift induced by aging, this paper proposes an adaptive signal separation method based on feature optimization of the time–frequency cumulative energy function. This method constructs novel characteristic parameters—namely, oblique intercept width and morphological gradient steepness—to effectively capture the fundamental differences in the energy accumulation process of the signals. Experimental verification demonstrates that even under conditions of varying interference characteristics, the proposed method achieves high-precision separation of PD signals from IGBT noise, outperforming traditional equivalent time–frequency and wavelet principal component analysis methods. This research provides crucial theoretical and technical support for insulation condition monitoring and device aging diagnosis in VSC-HVDC converter valves.
- 10 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 751
Open AccessAnalysis and Adaptive Separation of IGBT Switching Noise in PD Monitoring of Flexible HVDC Valves: An Evolutionary Perspective
The high-frequency switching noise of insulated-gate bipolar transistors (IGBTs) limits the sensitivity of online partial discharge (PD) monitoring in ultra-high-voltage flexible DC (VSC-HVDC) transmission systems. To address this challenge, this study investigates the underlying mechanisms and evolution of this interference and develops an anti-interference signal separation method. Simulation and experimental results indicate that the energy of IGBT switching noise is concentrated in the 30–180 MHz range, which significantly overlaps with the ultra-high-frequency (UHF) band used for PD detection. This research further reveals the pronounced modulation effect of device aging on the interference spectrum: bond wire aging triggers “spectral reconstruction” via altered parasitic parameters, where severe collector aging leads to an abnormal surge in turn-off interference amplitude. In contrast, gate oxide layer degradation manifests as characteristic “global spectrum attenuation” and a shift in peak frequency toward lower bands. Confronted with the challenges of strong interference and spectrum drift induced by aging, this paper proposes an adaptive signal separation method based on feature optimization of the time–frequency cumulative energy function. This method constructs novel characteristic parameters—namely, oblique intercept width and morphological gradient steepness—to effectively capture the fundamental differences in the energy accumulation process of the signals. Experimental verification demonstrates that even under conditions of varying interference characteristics, the proposed method achieves high-precision separation of PD signals from IGBT noise, outperforming traditional equivalent time–frequency and wavelet principal component analysis methods. This research provides crucial theoretical and technical support for insulation condition monitoring and device aging diagnosis in VSC-HVDC converter valves.
- Top Cited Papers
- 23 January 2026
- Published by Elsevier in Nano Energy
- Vol. 150
Electric field-assisted construction of bionic directional channels enhances charge storage in MXene/Ecoflex triboelectric nanogenerators for self-powered sensing
- 23 January 2026
- Published by Elsevier in Nano Energy
- Vol. 150
Top Cited PapersElectric field-assisted construction of bionic directional channels enhances charge storage in MXene/Ecoflex triboelectric nanogenerators for self-powered sensing
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- p. 1
A Review on Electric Field-Assisted Enhancement of Electrical and Thermal Performance of Advanced Insulation Materials: Mechanisms, Properties, and Applications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- p. 1
A Review on Electric Field-Assisted Enhancement of Electrical and Thermal Performance of Advanced Insulation Materials: Mechanisms, Properties, and Applications
- 13 December 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 201
Room-temperature hydrogen sensor based on optimized interdigitated palladium nanofilm: Structure and performance
- 13 December 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 201
Room-temperature hydrogen sensor based on optimized interdigitated palladium nanofilm: Structure and performance
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Time–Frequency Fusion Algorithms for Cable Fault Diagnosis Based on Stepped-Frequency Waveform Reflectometry
The traveling wave reflection method helps detect soft faults in cables to ensure safe and stable operation of modern industrial systems. However, The inherent drawbacks of fault location algorithms (e.g., time-domain broadening and spectral leakage, etc.) and multiple reflection seriously affect the reliability of the traveling wave reflection method. Thus, the time-frequency fusion algorithms based on stepped-frequency waveform reflectometry (SFWR) are proposed to overcome these issues, mainly including the pulse segmentation technique and multiple reflection suppression technique. The pulse segmentation technique aims to segment SFWR pulse signals in the time-domain, prior to the fault location, which can avoid the inherent drawbacks of the traditional fault location algorithms. The multiple reflection suppression technique can effectively suppress the interference of multiple reflection on fault location through the recursive relationship between single and multiple reflections. Simulations and experiments show that the SFWR time-frequency fusion algorithms exhibit good performance in different cases.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Time–Frequency Fusion Algorithms for Cable Fault Diagnosis Based on Stepped-Frequency Waveform Reflectometry
The traveling wave reflection method helps detect soft faults in cables to ensure safe and stable operation of modern industrial systems. However, The inherent drawbacks of fault location algorithms (e.g., time-domain broadening and spectral leakage, etc.) and multiple reflection seriously affect the reliability of the traveling wave reflection method. Thus, the time-frequency fusion algorithms based on stepped-frequency waveform reflectometry (SFWR) are proposed to overcome these issues, mainly including the pulse segmentation technique and multiple reflection suppression technique. The pulse segmentation technique aims to segment SFWR pulse signals in the time-domain, prior to the fault location, which can avoid the inherent drawbacks of the traditional fault location algorithms. The multiple reflection suppression technique can effectively suppress the interference of multiple reflection on fault location through the recursive relationship between single and multiple reflections. Simulations and experiments show that the SFWR time-frequency fusion algorithms exhibit good performance in different cases.