HYHuanmin Yao

Huanmin Yao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huanmin Yao has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis and Adaptive Separation of IGBT Switching Noise in PD Monitoring of Flexible HVDC Valves: An Evolutionary Perspective

    by Jiangfeng Si, Maoqun Shen, Bing Yu, Yongtao Jin, Guangsheng Cai, Qifeng Bian, Tong Bai, Huanmin Yao, Haibao Mu

    The high-frequency switching noise of insulated-gate bipolar transistors (IGBTs) limits the sensitivity of online partial discharge (PD) monitoring in ultra-high-voltage flexible DC (VSC-HVDC) transmission systems. To address this challenge, this study investigates the underlying mechanisms and evolution of this interference and develops an anti-interference signal separation method. Simulation and experimental results indicate that the energy of IGBT switching noise is concentrated in the 30–180 MHz range, which significantly overlaps with the ultra-high-frequency (UHF) band used for PD detection. This research further reveals the pronounced modulation effect of device aging on the interference spectrum: bond wire aging triggers “spectral reconstruction” via altered parasitic parameters, where severe collector aging leads to an abnormal surge in turn-off interference amplitude. In contrast, gate oxide layer degradation manifests as characteristic “global spectrum attenuation” and a shift in peak frequency toward lower bands. Confronted with the challenges of strong interference and spectrum drift induced by aging, this paper proposes an adaptive signal separation method based on feature optimization of the time–frequency cumulative energy function. This method constructs novel characteristic parameters—namely, oblique intercept width and morphological gradient steepness—to effectively capture the fundamental differences in the energy accumulation process of the signals. Experimental verification demonstrates that even under conditions of varying interference characteristics, the proposed method achieves high-precision separation of PD signals from IGBT noise, outperforming traditional equivalent time–frequency and wavelet principal component analysis methods. This research provides crucial theoretical and technical support for insulation condition monitoring and device aging diagnosis in VSC-HVDC converter valves.


  • Open Access

    Temperature normalisation and moisture assessment of oil‐paper insulation based on dielectric response in extremely cold conditions

    by Wenrui Tian, Daning Zhang, Huanmin Yao, Haisong Xu, Pengjiang Xu, Dingqian Yang, Guanjun Zhang

    Frequency domain spectroscopy (FDS) is widely used for assessing the condition of oil‐paper insulated electrical equipment. However, in low temperatures, measurement results often deviate from expected values. This study investigates the low‐temperature dielectric response characteristics of oil‐paper insulation under large temperature differences (−60°C to 30°C), wide frequency ranges (1 mHz–5 kHz) and varying moisture contents (0.41%–3.91%). The mechanisms of low‐temperature effects on oil‐paper insulation relaxation polarisation are revealed. Further, a novel low‐temperature normalisation method and a moisture evaluation method are proposed based on the improved Havriliak–Negami model. Compared to traditional methods, the new approach significantly enhances the accuracy. The goodness of fit R 2 for temperature normalisation improves from 0.9526 to 0.9757, and the error in moisture content evaluation has reached 0.498%. Finally, the novel approach is applied to diagnose the condition of a damped bushing model, demonstrating high potential for practical applications. This study enables condition diagnosis of oil‐impregnated electrical equipment in extremely cold environments, filling a critical gap in the field.


  • Open Access

    The mechanism of tuning filler orientation degree in composites based on AC electric field assist: from microscopic dynamical model to macroscopic electrical properties

    by Huanmin Yao, Haibao Mu, He Li, Zhiyuan Qian, Chengshan Liu, Wendong Li, Daning Zhang, Guan-Jun Zhang

    Using the AC electric field to induce the orientation of nonlinear conductive fillers in composites is an effective solution for alleviating electric field distortion in power modules. However, the mechanism by which the electric field affects the filler dynamic characteristics and the composites’ electrical properties remains unclear. In this paper, the correlation between the microscopic dynamic processes of fillers and the macroscopic current amplitude was analyzed. The results show that the current increases rapidly (0 ∼ 173 s) and then slowly (173 ∼ 869 s) at 600 V mm−1, influenced by the rotation and attraction processes of the fillers. This demonstrates that the orientation stops at about 869 s and the filler orientation state is a key factor in determining the dielectric properties. Secondly, the global orientation evaluation index D for the filler network was proposed, which can also derive the minimum time and energy loss required for preparation. Finally, the impact of different filler orientations on the composites’ conductivity was investigated. In the low electric field stress region, with the average carrier jump distance decreasing from 150.23 to 109.71 nm as the D increases from −0.93 to −0.05. On this basis, materials with nonlinear conductivity gradient distribution can be easily prepared. Before optimization, the electric field stress of the power module at the triple point was 35.79 kV. This composite can reduce the value to 15.42 kV, a decrease of 56.9%, while maintaining good electric field uniformity.


  • Characteristics of Electrical Tree Growing on Gel-Substrate Surface for Power Module at High-Frequency Positive Square Wave Voltage

    by He Li, Haibao Mu, Huanmin Yao, Yang Yang, Xin Zhao, Zhiyuan Qian, Chengshan Liu, Guanjun Zhang

    Electrical tree growing on the gel-substrate interface is the main form of insulation failure in power module packages. Studying electrical tree behavior can reveal the insulation degradation process, enabling targeted measures for inhibition. However, treeing behavior along the interface is currently unclear. For the wide frequency range of operating requirements of power modules, electrical tree characteristics growing on the gel-substrate interface under positive square wave voltage with a frequency of $1~\sim ~20$ kHz were investigated in this article. First, electrical tree characteristics at different frequencies were analyzed in terms of initiation, morphology, and propagation. Furthermore, the mechanism of electrical tree characteristics and the effect of frequency were investigated. The results show that the electrical tree inception voltage (ETIV) decreases with frequency. ETIV decreases more from 1 to 10 kHz than from 10 to 20 kHz due to the weakening of the electric field by homopolar space charge. Higher frequency reduces charge injection depth and increases dielectric loss, resulting in a denser initial tree morphology. The electrical tree evolves from branch-like to bush-like when 1 kHz < f <10 kHz while evolving from bush-like to pine-like when 10 kHz $\le $ f $\le 20$ kHz. Electrical tree morphology transformation is influenced by partial discharges (PDs), material properties, charge transport, and tree conductivity. Carbon depositions increase with frequency, affecting electrical tree morphology by increasing tree conductivity. The growth rate decreases with length for 1 kHz < f <10 kHz but decreases first and then increases for 10 kHz $\le $ f $\le 20$ kHz. The field-driven tree growth (FDTG) model is used to explain the characteristics of tree propagation when 10 kHz $\le $ f $\le 20$ kHz.


  • Dielectric Characteristic Analysis and Insulation State Evaluation of Packaging Material for Power Module With Different Aging Degrees

    by Huanmin Yao, Jiangyang Zhan, Haibao Mu, He Li, Ning Ding, Haoxiang Zhao, Dewen Zhang, Daning Zhang, Guanjun Zhang

    Epoxy resin (EP) exhibits excellent electrical and mechanical properties, which make it a promising material for insulation in high-voltage power modules. However, prolonged exposure to high temperatures can lead to thermo-oxidative aging of EP, ultimately resulting in irreparable damage to the insulation. This study aims to analyze the impact of aging on EP dielectric properties and establish a model for assessing the aging state. First, the surface morphology of EP before and after thermo-oxidative aging was observed, followed by testing the frequency domain spectroscopy (FDS) curves of the sample. Subsequently, the electric field stress distribution and overall dielectric loss characteristics of the power module were studied under different aging degrees and voltage frequencies. Through decomposing FDS curves, the study revealed how thermo-oxidative aging affects the dielectric properties, and an evaluation model of aging state was constructed. The results indicate that aging can significantly increase the total dielectric loss and space charge polarization loss of the power module. The dielectric characteristic parameters corresponding to the space charge polarization were selected to establish an aging evaluation model, and the evaluation error is less than 0.064.


  • Two-Stage Electric Field Optimization Method for High-Voltage Power Module Using Dielectrically Graded Insulation Micro-Region

    by Huanmin Yao, Haibao Mu, Wendong Li, Daning Zhang, Haoxiang Zhao, Chao Wang, Guanjun Zhang

    Dielectrically graded insulation (DGI) with spatially inhomogeneous dielectric parameter distribution can provide extraordinary insulation performance for high-voltage power equipment. The most crucial objective in the application of DGI is to identify the optimal distribution of dielectric parameters. However, the calculation efficiency and electric field optimization results of the existing methods are poor under complex insulation structures. Also, the dielectric loss of DGI calculated by these methods is relatively large. In this work, an efficient DGI parameter optimization method was developed. Firstly, a variable density topology optimization model was proposed to improve the electric field uniformity of the power module and suppress the electric field stress at the triple point. Secondly, the influence of different model parameters on the mitigation degree of the electric field was studied to obtain the optimal parameters. Finally, to reduce the dielectric loss of the insulation, the DGI micro-region was constructed by narrowing the optimized region. Numerical results indicate that the model only needs 23 iterations to obtain the optimal result. After optimization, the electric field stress at the triple point is reduced by 71.7%. DGI micro-regions reduce dielectric loss by 85.1% compared to global DGI. This study shows that the proposed method is anticipated to provide a new route for the preparation and application of DGI.


  • A Fast Dielectric Response Measurement Instrument With Dynamic Power Supply Tracking and Active Suppression of Temperature Fluctuations

    by Daning Zhang, Lulin Xu, Wenrui Tian, Haibao Mu, Huanmin Yao, Haoxiang Zhao, Jie Tian, Guan-Jun Zhang

    This paper proposes a fast frequency domain dielectric spectroscopy (FDS) test scheme for diagnosing oil-paper insulation. The high-voltage output section introduces dynamic power supply tracking (DPST) and cascading techniques to generate high-voltage excitation signals. The DPST can increase the amplifier's voltage slew rate (SR) from 13 V per microsecond to 36.3 V per microsecond without crossover distortion. In the micro-current measurement section, the error active suppression structure of bias current and bias current under time-varying temperature conditions is proposed to improve the temperature stability of the measurement circuit. The fast testing technology shortens the test period by 65% in the low-frequency band by using the method of multi-frequency signal synthesis and partial cycle waveform fitting. The experimental results show that the total harmonic distortion and noise (THD+N) of the output voltage of the instrument are less than or equal to 0.078%. The voltage range is 780 Vpp. The standard deviation of current is less than 1.5%, and the standard deviation of tan δ is less than 1.7%, which verifies the stability of the designed instrument.


  • The Insulation Characteristics of Optical Fiber in Transformer Oil Under Long-term Thermal Aging

    by Ning Ding, Chengjun Wang, Haibao Mu, Jiangyang Zhan, Huanmin Yao, Lingfeng Jin, Ping Qian, Chen Li, Guanjun Zhang

    Traditional methods cannot detect hot spot temperature, mechanical vibration and partial discharge signal and other state parameters of the transformer in real time. Optical fiber sensing technology has a wide range of application prospects due to its high accuracy, strong anti-interference ability and distributed measurement. However, the premise for its application is that the embedded optical fiber does not affect the safe operation of the transformer. This paper explores the interact between embedded fibers and transformers. In this paper, four different types of optical fibers were initially selected to prepare fiber-oil composite insulation. Samples under different aging time were obtained through accelerated thermal aging experiments. The mechanical strength and optical loss characteristics of fibers with different aging degrees were tested separately. At the same time, moisture content, acid value, oil chromatogram, dielectric loss factor and volume resistivity of insulating oil were tested. The results show that the mechanical strength of the PVC tight fiber decreases significantly as the aging time increases. PVC tight fiber significantly improves the dielectric loss factor, CO 2 /CO and total hydrocarbon content in insulating oil. The mechanical properties of the other three optical fibers remain basically unchanged and have little effect on the insulating oil. Thermal stress does not affect the optical transmission characteristics of all optical fibers. The PVC tight fiber is not suitable as the embedded optical fiber in transformers, while the other three optical fibers meet the basic requirements of the embedded optical fiber. The experimental results provide solutions for the safety risk assessment of the embedded optical fiber in transformers.