MPMinxuan Peng

Minxuan Peng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Minxuan Peng has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Improved Reactance Control for Stability Enhancement of Grid-Forming Converter Based on Series-Regulated Branch

    by Minxuan Peng, Jianjun Sun, Neng Peng, Qionglin Li, Yi Wang, Xiaoming Zha, Yi Tang

    Virtual admittance control can enhance the stability of grid-forming converters in stiff grid. However, admittance control may induce a negative damping effect during reverse power operation, leading to system instability. Furthermore, under low dc-link voltage conditions, grid-forming converters implementing virtual admittance control are prone to over-modulation, resulting in control failure. To address these issues, this article proposes an improved reactance control that adjusts the set reactance to compensate for the deviation in equivalent reactance based on the frequency difference. Additionally, this article introduces a scheme that adopts a series of Boost circuits as a series-regulated branch to achieve the proposed reactance control. Theoretical analysis shows that the proposed method can achieve effective output of high damping voltage and positive damping enhancement of power across the entire range compared with the conventional virtual admittance and other voltage-based damping methods. Quantitative analysis and comparison are conducted using the Lyapunov direct method and the attraction region. The efficacy of the proposed method and the theoretical analysis are substantiated through prototype experiments.

  • Power Reserve Control of PV Grid-Tied Inverter With Transient Stability Constraint

    by Yangjian Ling, Meng Huang, Pan Feng, Minxuan Peng, Zhen Tian, Sirui Shu, Xiaoming Zha, Xin Ma

    To support the grid frequency, the power reserve control is adopted in the photovoltaic (PV) system without the energy storage. As an important part of the PV system, the influence of the dc-link voltage dynamics is ignored in the grid-tied inverter so that the PV source and grid-tied inverter cooperative control is rarely designed to enhance the transient stability. In this article, the dc-link voltage dynamics are taken into consideration for the transient stability analysis of the grid-following (GFL) control and the grid-forming (GFM) control. It is found that the dc-link voltage dynamics deteriorate the transient stability of the GFL inverter and the GFM inverter. By analogy with the mass-spring-damper system, the enhanced controls are proposed with the equivalent elasticity for the GFL inverter and the GFM inverter. To support the grid frequency and enhance the transient stability, the frequency deviation feedback and equivalent elasticity cooperative control is proposed to regulate the active power of the PV source. Simulation tests are performed on a 10 kW grid-tied PV system and experimental tests are performed on a 1500 W grid-tied PV system, where the effectiveness of enhanced controls is verified.


  • Inertia Transmission Control of Full-Power Converter Variable-Speed Pumped Storage System for Grid Frequency Support

    by Kaihsun Chuang, Xiongfei Tao, Yihang Luan, Minxuan Peng, Jianjun Sun, Xiaoming Zha

    Full-power converter variable-speed pumped storage (FPC-VSPS) is a promising technique for flexible power regulation in small-scale distributed hydroelectric power plants. However, conventional vector control limits the synchronous motor of the FPC-VSPS from providing inertia support to the power grid. To overcome this limitation, this paper introduces an inertia transmission control for FPC-VSPS based on the concept of DC voltage synchronization. Firstly, the control incorporates the DC capacitor power equation into the GSC control. To enable inertia transmission from the FPC-VSPS synchronous machine, the DC capacitor dynamics are fed into both the speed and torque control of the MSC. Secondly, a torsion spring-rigid body equivalent model is introduced based on the inertia transmission process, analyzing the effects of physical parameters, control coefficients, and transmission delays on the inertia transmission performance. Theoretical analysis and simulation results reveal that the inherent physical differences and transmission delay have a negative impact on the effectiveness of the inertia transmission. Consequently, a DC capacitor design method based on inertia matching is proposed, accounting for the constraints of physical inertia matching, system stability, and operational security. Finally, simulations and experiments prove the necessity of inertia matching and verify the effectiveness of the proposed control to cope with frequency fluctuations in both pumping and generating modes.


  • Self-Excited Three-Port Converter for Photovoltaic Application With Stability Enhancement

    by Minxuan Peng, Jianjun Sun, Yi Liu, Xiaoming Zha, Meng Huang

    Reducing the impact of system voltage on the phase-locked loop in weak grid is an effective method to enhance the stability of grid-connected inverters. This article introduces a self-excited three-port converter topology, which utilizes a zigzag transformer to construct a small capacity series ac port on the dc–dc module of a two-stage photovoltaic grid-connected converter, achieving the goal of adjusting the grid voltage with its power and extending the degree of freedom in the grid-connected converter control. At the same time, an impedance compensation strategy based on the series ac port is proposed to suppress the impact of the grid-connected converter output circuit on the grid voltage and enhance the system stability on the time scale of the phase-locked loop. Theoretical analysis shows that the proposed converter topology and control method can significantly improve the stability so that the grid-connected converter can adapt to weak grid. Simulation and 1.6 kW prototype experiments prove that the proposed topology can effectively improve the stability of the converter system in weak grid with short-circuit ratio of 1.49 by compensating the impedance value of the power grid.