James E. Younkin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James E. Younkin has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Martin Bues
Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ, USA
4 shared publicationsWei Liu
Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ, USA
4 shared publicationsJiajian Shen
Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ, USA
3 shared publicationsJoshua B. Stoker
Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ, USA
3 shared publicationsStephen P. Martin
Department of Physics, Northern Illinois University, DeKalb Illinois 60115, USA
3 shared publicationsDanairis Hernandez Morales
Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ, USA
2 shared publications
Latest Publications
- 12 May 2022
- Published by Wiley
- p. 81-100
Image‐Guided Particle Therapy and Motion Management
- Open Access
- 1 January 2019
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 18
Clinical Validation of a Ray-Casting Analytical Dose Engine for Spot Scanning Proton Delivery Systems
Purpose: To describe and validate the dose calculation algorithm of an independent second-dose check software for spot scanning proton delivery systems with full width at half maximum between 5 and 14 mm and with a negligible spray component. Methods: The analytical dose engine of our independent second-dose check software employs an altered pencil beam algorithm with 3 lateral Gaussian components. It was commissioned using Geant4 and validated by comparison to point dose measurements at several depths within spread-out Bragg peaks of varying ranges, modulations, and field sizes. Water equivalent distance was used to compensate for inhomogeneous geometry. Twelve patients representing different disease sites were selected for validation. Dose calculation results in water were compared to a fast Monte Carlo code and ionization chamber array measurements using dose planes and dose profiles as well as 2-dimensional–3-dimensional and 3-dimensional–3-dimensional γ-index analysis. Results in patient geometry were compared to Monte Carlo simulation using dose–volume histogram indices, 3-dimensional–3-dimensional γ-index analysis, and inpatient dose profiles. Results: Dose engine model parameters were tuned to achieve 1.5% agreement with measured point doses. The in-water γ-index passing rates for the 12 patients using 3%/2 mm criteria were 99.5% ± 0.5% compared to Monte Carlo. The average inpatient γ-index analysis passing rate compared to Monte Carlo was 95.8% ± 2.9%. The average difference in mean dose to the clinical target volume between the dose engine and Monte Carlo was −0.4% ± 1.0%. For a typical plan, dose calculation time was 2 minutes on an inexpensive workstation. Conclusions: Following our commissioning process, the analytical dose engine was validated for all treatment sites except for the lung or for calculating dose–volume histogram indices involving point doses or critical structures immediately distal to target volumes. Monte Carlo simulations are recommended for these scenarios.
- 1 January 2019
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 18
Open AccessClinical Validation of a Ray-Casting Analytical Dose Engine for Spot Scanning Proton Delivery Systems
Purpose: To describe and validate the dose calculation algorithm of an independent second-dose check software for spot scanning proton delivery systems with full width at half maximum between 5 and 14 mm and with a negligible spray component. Methods: The analytical dose engine of our independent second-dose check software employs an altered pencil beam algorithm with 3 lateral Gaussian components. It was commissioned using Geant4 and validated by comparison to point dose measurements at several depths within spread-out Bragg peaks of varying ranges, modulations, and field sizes. Water equivalent distance was used to compensate for inhomogeneous geometry. Twelve patients representing different disease sites were selected for validation. Dose calculation results in water were compared to a fast Monte Carlo code and ionization chamber array measurements using dose planes and dose profiles as well as 2-dimensional–3-dimensional and 3-dimensional–3-dimensional γ-index analysis. Results in patient geometry were compared to Monte Carlo simulation using dose–volume histogram indices, 3-dimensional–3-dimensional γ-index analysis, and inpatient dose profiles. Results: Dose engine model parameters were tuned to achieve 1.5% agreement with measured point doses. The in-water γ-index passing rates for the 12 patients using 3%/2 mm criteria were 99.5% ± 0.5% compared to Monte Carlo. The average inpatient γ-index analysis passing rate compared to Monte Carlo was 95.8% ± 2.9%. The average difference in mean dose to the clinical target volume between the dose engine and Monte Carlo was −0.4% ± 1.0%. For a typical plan, dose calculation time was 2 minutes on an inexpensive workstation. Conclusions: Following our commissioning process, the analytical dose engine was validated for all treatment sites except for the lung or for calculating dose–volume histogram indices involving point doses or critical structures immediately distal to target volumes. Monte Carlo simulations are recommended for these scenarios.
- 20 November 2018
- Published by Wiley in Medical Physics
- Vol. 46 (1) , 5-14
Automation of routine elements for spot‐scanning proton patient‐specific quality assurance
Purpose At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identified the steps that could be automated and developed solutions to improve efficiency. Methods We used the treatment planning system's (TPS) capability to support C# scripts to develop an Eclipse scripting application programming interface (ESAPI) script and automate the preparation of the verification phantom plan for measurements. A local area network (LAN) connection between our measurement equipment and shared database was established to facilitate equipment control, measurement data transfer, and storage. To improve the analysis of the measurement data, a Python script was developed to automatically perform a 2D-3D gamma-index analysis comparing measurements in the plane of a two-dimensional detector array with TPS predictions in a water phantom for each acquired measurement. Results Device connection via LAN granted immediate access to the plan and measurement information for downstream analysis using an online software suite. Automated scripts applied to verification plans reduced time from preparation steps by at least 50%; time reduction from automating gamma-index analysis was even more pronounced, dropping by a factor of 10. On average, we observed an overall time savings of 55% in completion of the PSQA per patient plan. Conclusions The automation of the routine tasks in the PSQA workflow significantly reduced the time required per patient, reduced user fatigue, and frees up system users from routine and repetitive workflow steps allowing increased focus on evaluating key quality metrics.
- 20 November 2018
- Published by Wiley in Medical Physics
- Vol. 46 (1) , 5-14
Automation of routine elements for spot‐scanning proton patient‐specific quality assurance
Purpose At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identified the steps that could be automated and developed solutions to improve efficiency. Methods We used the treatment planning system's (TPS) capability to support C# scripts to develop an Eclipse scripting application programming interface (ESAPI) script and automate the preparation of the verification phantom plan for measurements. A local area network (LAN) connection between our measurement equipment and shared database was established to facilitate equipment control, measurement data transfer, and storage. To improve the analysis of the measurement data, a Python script was developed to automatically perform a 2D-3D gamma-index analysis comparing measurements in the plane of a two-dimensional detector array with TPS predictions in a water phantom for each acquired measurement. Results Device connection via LAN granted immediate access to the plan and measurement information for downstream analysis using an online software suite. Automated scripts applied to verification plans reduced time from preparation steps by at least 50%; time reduction from automating gamma-index analysis was even more pronounced, dropping by a factor of 10. On average, we observed an overall time savings of 55% in completion of the PSQA per patient plan. Conclusions The automation of the routine tasks in the PSQA workflow significantly reduced the time required per patient, reduced user fatigue, and frees up system users from routine and repetitive workflow steps allowing increased focus on evaluating key quality metrics.
- Open Access
- 1 July 2018
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 3 (3) , 412-420
Multiple energy extraction reduces beam delivery time for a synchrotron-based proton spot-scanning system
- 1 July 2018
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 3 (3) , 412-420
Open AccessMultiple energy extraction reduces beam delivery time for a synchrotron-based proton spot-scanning system
- 19 February 2018
- Published by Wiley in Medical Physics
- Vol. 45 (3) , 1040-1049
Technical Note: An efficient daily QA procedure for proton pencil beam scanning
Purpose: The aim of this work was to develop an efficient daily quality assurance (QA) program with strict tolerance levels for pencil beam scanning (PBS) proton radiotherapy featuring simultaneous dosimetric testing on a single, nonuniform field.Methods: A nonuniform field measuring beam output, proton range, and spot position was designed for delivery onto a Sun Nuclear Daily‐QA 3 device. A custom acrylic block permitted simultaneous measurement of low‐ and high‐energy proton ranges in addition to beam output. Sensitivities to output, range, and spot position were evaluated to quantitate the device's response. Reproducibility tests were used to identify and control sources of measurement error as well as to assess the QA procedure's robustness. This procedure was implemented in each of our four treatment rooms independently; 4–6 months of daily QA measurements were collected.Results: The 1% output, 0.5 mm range, and 1.5 mm spot position tolerances derived from preliminary tests were tighter overall than tolerances found in the literature and equivalent to the limits used for proton system commissioning. The simplicity and automation of the procedure reduced the time required for daily QA to 10 min per treatment room, and competition for beam between multiple treatment rooms was minimized.Conclusions: An efficient daily PBS QA procedure can be performed using a single, nonuniform field on a nondedicated QA device. A thorough quantitation of the device's response and careful control of measurement uncertainties allowed daily tolerances to match commissioning standards.
- 19 February 2018
- Published by Wiley in Medical Physics
- Vol. 45 (3) , 1040-1049
Technical Note: An efficient daily QA procedure for proton pencil beam scanning
Purpose: The aim of this work was to develop an efficient daily quality assurance (QA) program with strict tolerance levels for pencil beam scanning (PBS) proton radiotherapy featuring simultaneous dosimetric testing on a single, nonuniform field.Methods: A nonuniform field measuring beam output, proton range, and spot position was designed for delivery onto a Sun Nuclear Daily‐QA 3 device. A custom acrylic block permitted simultaneous measurement of low‐ and high‐energy proton ranges in addition to beam output. Sensitivities to output, range, and spot position were evaluated to quantitate the device's response. Reproducibility tests were used to identify and control sources of measurement error as well as to assess the QA procedure's robustness. This procedure was implemented in each of our four treatment rooms independently; 4–6 months of daily QA measurements were collected.Results: The 1% output, 0.5 mm range, and 1.5 mm spot position tolerances derived from preliminary tests were tighter overall than tolerances found in the literature and equivalent to the limits used for proton system commissioning. The simplicity and automation of the procedure reduced the time required for daily QA to 10 min per treatment room, and competition for beam between multiple treatment rooms was minimized.Conclusions: An efficient daily PBS QA procedure can be performed using a single, nonuniform field on a nondedicated QA device. A thorough quantitation of the device's response and careful control of measurement uncertainties allowed daily tolerances to match commissioning standards.
- 30 August 2017
- Published by Wiley in Medical Physics
- Vol. 44 (10) , 5081-5088
Technical Note: Using experimentally determined proton spot scanning timing parameters to accurately model beam delivery time
Purpose: To accurately model the beam delivery time (BDT) for a synchrotron‐based proton spot scanning system using experimentally determined beam parameters.Methods: A model to simulate the proton spot delivery sequences was constructed, and BDT was calculated by summing times for layer switch, spot switch, and spot delivery. Test plans were designed to isolate and quantify the relevant beam parameters in the operation cycle of the proton beam therapy delivery system. These parameters included the layer switch time, magnet preparation and verification time, average beam scanning speeds in x‐ and y‐directions, proton spill rate, and maximum charge and maximum extraction time for each spill. The experimentally determined parameters, as well as the nominal values initially provided by the vendor, served as inputs to the model to predict BDTs for 602 clinical proton beam deliveries. The calculated BDTs (TBDT) were compared with the BDTs recorded in the treatment delivery log files (TLog): ∆t = TLog−TBDT.Results: The experimentally determined average layer switch time for all 97 energies was 1.91 s (ranging from 1.9 to 2.0 s for beam energies from 71.3 to 228.8 MeV), average magnet preparation and verification time was 1.93 ms, the average scanning speeds were 5.9 m/s in x‐direction and 19.3 m/s in y‐direction, the proton spill rate was 8.7 MU/s, and the maximum proton charge available for one acceleration is 2.0 ± 0.4 nC. Some of the measured parameters differed from the nominal values provided by the vendor. The calculated BDTs using experimentally determined parameters matched the recorded BDTs of 602 beam deliveries (∆t = −0.49 ± 1.44 s), which were significantly more accurate than BDTs calculated using nominal timing parameters (∆t = −7.48 ± 6.97 s).Conclusions: An accurate model for BDT prediction was achieved by using the experimentally determined proton beam therapy delivery parameters, which may be useful in modeling the interplay effect and patient throughput. The model may provide guidance on how to effectively reduce BDT and may be used to identifying deteriorating machine performance.
- 30 August 2017
- Published by Wiley in Medical Physics
- Vol. 44 (10) , 5081-5088
Technical Note: Using experimentally determined proton spot scanning timing parameters to accurately model beam delivery time
Purpose: To accurately model the beam delivery time (BDT) for a synchrotron‐based proton spot scanning system using experimentally determined beam parameters.Methods: A model to simulate the proton spot delivery sequences was constructed, and BDT was calculated by summing times for layer switch, spot switch, and spot delivery. Test plans were designed to isolate and quantify the relevant beam parameters in the operation cycle of the proton beam therapy delivery system. These parameters included the layer switch time, magnet preparation and verification time, average beam scanning speeds in x‐ and y‐directions, proton spill rate, and maximum charge and maximum extraction time for each spill. The experimentally determined parameters, as well as the nominal values initially provided by the vendor, served as inputs to the model to predict BDTs for 602 clinical proton beam deliveries. The calculated BDTs (TBDT) were compared with the BDTs recorded in the treatment delivery log files (TLog): ∆t = TLog−TBDT.Results: The experimentally determined average layer switch time for all 97 energies was 1.91 s (ranging from 1.9 to 2.0 s for beam energies from 71.3 to 228.8 MeV), average magnet preparation and verification time was 1.93 ms, the average scanning speeds were 5.9 m/s in x‐direction and 19.3 m/s in y‐direction, the proton spill rate was 8.7 MU/s, and the maximum proton charge available for one acceleration is 2.0 ± 0.4 nC. Some of the measured parameters differed from the nominal values provided by the vendor. The calculated BDTs using experimentally determined parameters matched the recorded BDTs of 602 beam deliveries (∆t = −0.49 ± 1.44 s), which were significantly more accurate than BDTs calculated using nominal timing parameters (∆t = −7.48 ± 6.97 s).Conclusions: An accurate model for BDT prediction was achieved by using the experimentally determined proton beam therapy delivery parameters, which may be useful in modeling the interplay effect and patient throughput. The model may provide guidance on how to effectively reduce BDT and may be used to identifying deteriorating machine performance.
- Open Access
- 30 March 2012
- Published by American Physical Society (APS) in Physical Review D
- Vol. 85 (5) , 055028
Nonuniversal gaugino masses, the supersymmetric little hierarchy problem, and dark matter
We study a class of supersymmetric models with nonuniversal gaugino masses that could arise from -terms in a general combination of the singlet and adjoint representations of . We explore models that satisfy present Large Hadron Collider and other bounds, showing how the allowed parameter space is divided into distinct “continents.” Regions of parameter space that ameliorate the supersymmetric little hierarchy problem with a small parameter include the usual focus-point scenario, but also natural areas with much lighter squarks and sleptons. These models are continuously connected in parameter space to regions in which stau coannihilation or Higgs exchange is mostly responsible for dark matter annihilation, and to models in which the thermal relic abundance is achieved by slepton-mediated annihilation, reviving the bulk region that is severely restricted in minimal supergravity models. In hybrid or confluence regions, several mechanisms combine to give the requisite dark matter annihilation rate. In each case, we study the prospects for direct detection of dark matter. We also comment briefly on the impact of recent hints for near 125 GeV from the LHC.- 30 March 2012
- Published by American Physical Society (APS) in Physical Review D
- Vol. 85 (5) , 055028
Open AccessNonuniversal gaugino masses, the supersymmetric little hierarchy problem, and dark matter
We study a class of supersymmetric models with nonuniversal gaugino masses that could arise from -terms in a general combination of the singlet and adjoint representations of . We explore models that satisfy present Large Hadron Collider and other bounds, showing how the allowed parameter space is divided into distinct “continents.” Regions of parameter space that ameliorate the supersymmetric little hierarchy problem with a small parameter include the usual focus-point scenario, but also natural areas with much lighter squarks and sleptons. These models are continuously connected in parameter space to regions in which stau coannihilation or Higgs exchange is mostly responsible for dark matter annihilation, and to models in which the thermal relic abundance is achieved by slepton-mediated annihilation, reviving the bulk region that is severely restricted in minimal supergravity models. In hybrid or confluence regions, several mechanisms combine to give the requisite dark matter annihilation rate. In each case, we study the prospects for direct detection of dark matter. We also comment briefly on the impact of recent hints for near 125 GeV from the LHC. - 17 March 2010
- Published by American Physical Society (APS) in Physical Review D
- Vol. 81 (5)
QCD corrections to stoponium production at hadron colliders
If the lighter top squark has no kinematically allowed two-body decays that conserve flavor, then it will live long enough to form hadronic bound states. The observation of the diphoton decays of stoponium could then provide a uniquely precise measurement of the top squark mass. In this paper, we calculate the cross section for the production of stoponium in a hadron collider at next-to-leading order (NLO) in QCD. We present numerical results for the cross section for production of stoponium at the LHC and study the dependence on beam energy, stoponium mass, and the renormalization and factorization scale. The cross-section is substantially increased by the NLO corrections, counteracting a corresponding decrease found earlier in the NLO diphoton branching ratio.
- 17 March 2010
- Published by American Physical Society (APS) in Physical Review D
- Vol. 81 (5)
QCD corrections to stoponium production at hadron colliders
If the lighter top squark has no kinematically allowed two-body decays that conserve flavor, then it will live long enough to form hadronic bound states. The observation of the diphoton decays of stoponium could then provide a uniquely precise measurement of the top squark mass. In this paper, we calculate the cross section for the production of stoponium in a hadron collider at next-to-leading order (NLO) in QCD. We present numerical results for the cross section for production of stoponium at the LHC and study the dependence on beam energy, stoponium mass, and the renormalization and factorization scale. The cross-section is substantially increased by the NLO corrections, counteracting a corresponding decrease found earlier in the NLO diphoton branching ratio.
- 27 August 2009
- Published by American Physical Society (APS) in Physical Review D
- Vol. 80 (3) , 035026
Radiative corrections to stoponium annihilation decays
The lighter top squark in supersymmetry can live long enough to form hadronic bound states if it has no kinematically allowed two-body decays that conserve flavor. In this case, scalar stoponium may be observable through its diphoton decay mode at the CERN Large Hadron Collider, enabling a uniquely precise measurement of the top-squark mass. The viability of the signal depends crucially on the branching ratio to diphotons. We compute the next-to-leading-order QCD radiative corrections to stoponium annihilation decays to hadrons, photons, and Higgs scalar bosons. We find that the effect of these corrections is to significantly decrease the predicted branching ratio to the important diphoton channel. We also find a greatly improved renormalization-scale dependence of the diphoton branching ratio prediction.
- 27 August 2009
- Published by American Physical Society (APS) in Physical Review D
- Vol. 80 (3) , 035026
Radiative corrections to stoponium annihilation decays
The lighter top squark in supersymmetry can live long enough to form hadronic bound states if it has no kinematically allowed two-body decays that conserve flavor. In this case, scalar stoponium may be observable through its diphoton decay mode at the CERN Large Hadron Collider, enabling a uniquely precise measurement of the top-squark mass. The viability of the signal depends crucially on the branching ratio to diphotons. We compute the next-to-leading-order QCD radiative corrections to stoponium annihilation decays to hadrons, photons, and Higgs scalar bosons. We find that the effect of these corrections is to significantly decrease the predicted branching ratio to the important diphoton channel. We also find a greatly improved renormalization-scale dependence of the diphoton branching ratio prediction.