Abstract
Purpose At our institution, all proton patient plans undergo patient-specific quality assurance (PSQA) prior to treatment delivery. For intensity-modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identified the steps that could be automated and developed solutions to improve efficiency. Methods We used the treatment planning system's (TPS) capability to support C# scripts to develop an Eclipse scripting application programming interface (ESAPI) script and automate the preparation of the verification phantom plan for measurements. A local area network (LAN) connection between our measurement equipment and shared database was established to facilitate equipment control, measurement data transfer, and storage. To improve the analysis of the measurement data, a Python script was developed to automatically perform a 2D-3D gamma-index analysis comparing measurements in the plane of a two-dimensional detector array with TPS predictions in a water phantom for each acquired measurement. Results Device connection via LAN granted immediate access to the plan and measurement information for downstream analysis using an online software suite. Automated scripts applied to verification plans reduced time from preparation steps by at least 50%; time reduction from automating gamma-index analysis was even more pronounced, dropping by a factor of 10. On average, we observed an overall time savings of 55% in completion of the PSQA per patient plan. Conclusions The automation of the routine tasks in the PSQA workflow significantly reduced the time required per patient, reduced user fatigue, and frees up system users from routine and repetitive workflow steps allowing increased focus on evaluating key quality metrics.Keywords
Funding Information
- National Cancer Institute (K25CA168984)
- Arizona Biomedical Research Commission
This publication has 15 references indexed in Scilit:
- Treatment log files as a tool to identify treatment plan sensitivity to inaccuracies in scanned proton beam deliveryRadiotherapy and Oncology, 2017
- Quality assurance of carbon ion and proton beams: A feasibility study for using the 2D MatriXX detectorPhysica Medica, 2016
- Assessing the quality of proton PBS treatment delivery using machine log files: comprehensive analysis of clinical treatments delivered at PSI Gantry 2Physics in Medicine & Biology, 2016
- Towards Effective and Efficient Patient-Specific Quality Assurance for Spot Scanning Proton TherapyCancers, 2015
- Spot-Scanning Proton Therapy Patient-Specific Quality Assurance: Results from 309 Treatment PlansInternational Journal of Particle Therapy, 2014
- Improving spot‐scanning proton therapy patient specific quality assurance with HPlusQA, a second‐check dose calculation engineMedical Physics, 2013
- Use of treatment log files in spot scanning proton therapy as part of patient-specific quality assuranceMedical Physics, 2013
- Patient-Specific Quality Assurance for Prostate Cancer Patients Receiving Spot Scanning Proton Therapy Using Single-Field Uniform DoseInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Verification of patient‐specific dose distributions in proton therapy using a commercial two‐dimensional ion chamber arrayMedical Physics, 2010
- A technique for the quantitative evaluation of dose distributionsMedical Physics, 1998