Lucas Zago Naves
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lucas Zago Naves has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Marco Markus Maria Gresnigt
Department of Restorative Dentistry and Biomaterials Center for Dentistry Orthodontics, The University of Groningen, University Medical Center Groningen Groningen the Netherlands
2 shared publications Adérito Soares da Mota
Department of Fixed Prostheses, Occlusion and Dental Materials, School of Dentistry, Federal University of Uberlândia, Campus Umuarama, Avenida Pará No. 1720, Uberlândia, MG, Brazil
1 shared publication- Américo Bortolazzo Correr
State University of Campinas, Brazil
1 shared publication - Ana Rosa Costa
Department of Orthodontics, Hermínio Ometto Foundation - FHO, Araras, SP, Brazil
1 shared publication David‐Alain Gerdolle
Private Practice Montreaux Switzerland
1 shared publicationFernanda Midori Tsuzuki
UNICAMP, Brazil
1 shared publication
Latest Publications
- Open Access
- 12 February 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 152, 106459
Biomechanical behavior of molars restored with direct and indirect restorations in combination with deep margin elevation
- 12 February 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 152, 106459
Open AccessBiomechanical behavior of molars restored with direct and indirect restorations in combination with deep margin elevation
- Open Access
- 1 August 2021
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 32 (4) , 106-115
CHX Stabilizes the Resin/demineralized Dentin Interface
The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate (CHX) on microtensile bond strength (µTBS) between an adhesive system and under 3 dentin conditions. For that, this study evaluated the adhesive interface at initial, after 6 months and 1 year of storage. Forty-eight human third molars were prepared and randomly divided into 3 groups, according to dentin substrates: sound dentin (Sd), caries-infected dentin (Ci) and caries-affected dentin (Ca). The groups were subdivided into two according to the dentin pre-treatment: application of 2% CHX or without pre-treatment (control). The dentin surfaces were etched with 35% phosphoric acid gel and bonded with Adper Single Bond 2 (3M ESPE) adhesive system according to manufacturer’s instructions. Subsequently, the specimens were stored in deionized water at 37°C for 24h, 6 months and 1 year. Two additional teeth were used to analyze the bonding interfaces by SEM. Data was submitted to three-way ANOVA in a split plot design and Tukey’s test (α = 0.05). The results showed that Ci decreased µTBS values when compared to Ca and Sd, regardless storages time or treatment. Stored samples for 6 months and 1 year decreased the µTBS for the control group, but no difference was found between storages time for the CHX group. As a conclusion, the 2% CHX application after etching showed improved dentin bond strength in the storage time, regardless of the substrates evaluated.
- 1 August 2021
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 32 (4) , 106-115
Open AccessCHX Stabilizes the Resin/demineralized Dentin Interface
The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate (CHX) on microtensile bond strength (µTBS) between an adhesive system and under 3 dentin conditions. For that, this study evaluated the adhesive interface at initial, after 6 months and 1 year of storage. Forty-eight human third molars were prepared and randomly divided into 3 groups, according to dentin substrates: sound dentin (Sd), caries-infected dentin (Ci) and caries-affected dentin (Ca). The groups were subdivided into two according to the dentin pre-treatment: application of 2% CHX or without pre-treatment (control). The dentin surfaces were etched with 35% phosphoric acid gel and bonded with Adper Single Bond 2 (3M ESPE) adhesive system according to manufacturer’s instructions. Subsequently, the specimens were stored in deionized water at 37°C for 24h, 6 months and 1 year. Two additional teeth were used to analyze the bonding interfaces by SEM. Data was submitted to three-way ANOVA in a split plot design and Tukey’s test (α = 0.05). The results showed that Ci decreased µTBS values when compared to Ca and Sd, regardless storages time or treatment. Stored samples for 6 months and 1 year decreased the µTBS for the control group, but no difference was found between storages time for the CHX group. As a conclusion, the 2% CHX application after etching showed improved dentin bond strength in the storage time, regardless of the substrates evaluated.
- 8 July 2020
- Published by Wiley in Microscopy Research and Technique
- Vol. 83 (9) , 1118-1123
Seeing is believing? When scanning electron microscopy (SEM) meets clinical dentistry: The replica technique.
In restorative dentistry, the in situ replication of intra‐oral situations, is based on a non‐invasive and non‐destructive scanning electron microscopy (SEM) evaluation method. The technique is suitable for investigation restorative materials and dental hard‐ and soft‐tissues, and its interfaces. Surface characteristics, integrity of interfaces (margins), or fracture analysis (chipping, cracks, etc.) with reliable resolution and under high magnification (from ×50 to ×5,000). Overall the current study aims to share detailed and reproducible information about the replica technique. Specific goals are: (a) to describe detailed each step involved in producing a replica of an intra‐oral situation, (b) to validate an integrated workflow based on a rational sequence from visual examination, to macrophotography and SEM analysis using the replica technique; (c) to present three clinical cases documented using the technique. A compilation of three clinical situations/cases were analyzed here by means the replica technique showing a wide range of possibilities that can be reached and explored with the described technique. This guidance document will contribute to a more accurate use of the replica technique and help researchers and clinicians to understand and identify issues related to restorative procedures under high magnification.
- 8 July 2020
- Published by Wiley in Microscopy Research and Technique
- Vol. 83 (9) , 1118-1123
Seeing is believing? When scanning electron microscopy (SEM) meets clinical dentistry: The replica technique.
In restorative dentistry, the in situ replication of intra‐oral situations, is based on a non‐invasive and non‐destructive scanning electron microscopy (SEM) evaluation method. The technique is suitable for investigation restorative materials and dental hard‐ and soft‐tissues, and its interfaces. Surface characteristics, integrity of interfaces (margins), or fracture analysis (chipping, cracks, etc.) with reliable resolution and under high magnification (from ×50 to ×5,000). Overall the current study aims to share detailed and reproducible information about the replica technique. Specific goals are: (a) to describe detailed each step involved in producing a replica of an intra‐oral situation, (b) to validate an integrated workflow based on a rational sequence from visual examination, to macrophotography and SEM analysis using the replica technique; (c) to present three clinical cases documented using the technique. A compilation of three clinical situations/cases were analyzed here by means the replica technique showing a wide range of possibilities that can be reached and explored with the described technique. This guidance document will contribute to a more accurate use of the replica technique and help researchers and clinicians to understand and identify issues related to restorative procedures under high magnification.
- Open Access
- 19 July 2016
- Published by Wiley in International Journal of Dentistry
- Vol. 2016, 1-6
Bacterial Adhesion and Surface Roughness for Different Clinical Techniques for Acrylic Polymethyl Methacrylate
This study sought to assess the effect of different surface finishing and polishing protocols on the surface roughness and bacterial adhesion (S. sanguinis) to polymethyl methacrylates (PMMA). Fifty specimens were divided into 5 groups () according to their fabrication method and surface finishing protocol: LP (3 : 1 ratio and laboratory polishing), NF (Nealon technique and finishing), NP (Nealon technique and manual polishing), MF (3 : 1 ratio and manual finishing), and MP (3 : 1 ratio and manual polishing). For each group, five specimens were submitted to bacterial adhesion tests and analyzed by scanning electron microscopy (SEM). Two additional specimens were subjected to surface topography analysis by SEM and the remaining three specimens were subjected to surface roughness measurements. Data were compared by one-way ANOVA. The mean bacterial counts were as follows: NF,; MP,; NP,; MF,; and LP,(CFU). The mean surface roughness values were as follows: NF,; MP,; NP,; MF,; and LP,(m). A reduction in the surface roughness was observed to be directly related to a decrease in bacterial adhesion. It was verified that the laboratory processing of PMMA might decrease the surface roughness and consequently the adhesion ofS. sanguinisto this material.- 19 July 2016
- Published by Wiley in International Journal of Dentistry
- Vol. 2016, 1-6
Open AccessBacterial Adhesion and Surface Roughness for Different Clinical Techniques for Acrylic Polymethyl Methacrylate
This study sought to assess the effect of different surface finishing and polishing protocols on the surface roughness and bacterial adhesion (S. sanguinis) to polymethyl methacrylates (PMMA). Fifty specimens were divided into 5 groups () according to their fabrication method and surface finishing protocol: LP (3 : 1 ratio and laboratory polishing), NF (Nealon technique and finishing), NP (Nealon technique and manual polishing), MF (3 : 1 ratio and manual finishing), and MP (3 : 1 ratio and manual polishing). For each group, five specimens were submitted to bacterial adhesion tests and analyzed by scanning electron microscopy (SEM). Two additional specimens were subjected to surface topography analysis by SEM and the remaining three specimens were subjected to surface roughness measurements. Data were compared by one-way ANOVA. The mean bacterial counts were as follows: NF,; MP,; NP,; MF,; and LP,(CFU). The mean surface roughness values were as follows: NF,; MP,; NP,; MF,; and LP,(m). A reduction in the surface roughness was observed to be directly related to a decrease in bacterial adhesion. It was verified that the laboratory processing of PMMA might decrease the surface roughness and consequently the adhesion ofS. sanguinisto this material.