Xiaolan Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Xiaolan Yan has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Donglai Zhang
Harbin Institute of Technology
7 shared publications - Wei Gao
Shenzhen Aerospace New Power Technology, Ltd., Shenzhen, China
5 shared publications - Enchao Zhang
Power Electronic and Motion Control Research Center, Harbin Institute of Technology, Shenzhen, Shenzhen, China
4 shared publications - Hongpeng Wang
Harbin Institute of Technology (Shenzhen)
2 shared publications - Shimin Pan
The University of Hong Kong, Pokfulam, Hong Kong
2 shared publications - Xin Wang
School of Mechanical Engineering and Automation, Harbin Institute of Technology (Shenzhen), Shenzhen, China
2 shared publications
Latest Publications
- 6 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Distinguish Abnormal Tensile and Torsional Stresses of Steel Wire Rope Using Magnetoelastic Effect
Nondestructive testing and structural health monitoring are highly important for the safe operation of industrial systems. Steel wire ropes are key load-bearing components in these systems. Under the condition where multiple wire ropes are used simultaneously, the safe operation of the system will then be affected if the stress in these wire ropes is inconsistent. To date, research has focused mainly on changes in the tensile stress in steel wire ropes. Steel wire ropes are also affected by torsional stress during actual operation. The spiral structure of the wire rope means that when the torsional stress in the wire rope changes, then the tensile stress will also change. Abnormal tensile or torsional stresses in a wire rope will cause abnormal tensile stress in the wire rope. However, the treatment methods for these two stresses are different. It is thus necessary to distinguish the tensile and torsional stresses in steel wire ropes. This study uses the magnetoelastic effect to measure abnormal tensile and torsional stresses in steel wire rope through the time-domain and frequency-domain characteristics of a white noise signal. The method is to detect and distinguish the relative change of stresses in the multiple steel wire ropes. The frequency spectrum of the detection signal is used to detect abnormal stresses. The root mean square and center of gravity frequency of the detection signal are extracted to distinguish abnormal tensile and torsional stresses in multiple steel wire ropes and monitor its health.
- 6 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Distinguish Abnormal Tensile and Torsional Stresses of Steel Wire Rope Using Magnetoelastic Effect
Nondestructive testing and structural health monitoring are highly important for the safe operation of industrial systems. Steel wire ropes are key load-bearing components in these systems. Under the condition where multiple wire ropes are used simultaneously, the safe operation of the system will then be affected if the stress in these wire ropes is inconsistent. To date, research has focused mainly on changes in the tensile stress in steel wire ropes. Steel wire ropes are also affected by torsional stress during actual operation. The spiral structure of the wire rope means that when the torsional stress in the wire rope changes, then the tensile stress will also change. Abnormal tensile or torsional stresses in a wire rope will cause abnormal tensile stress in the wire rope. However, the treatment methods for these two stresses are different. It is thus necessary to distinguish the tensile and torsional stresses in steel wire ropes. This study uses the magnetoelastic effect to measure abnormal tensile and torsional stresses in steel wire rope through the time-domain and frequency-domain characteristics of a white noise signal. The method is to detect and distinguish the relative change of stresses in the multiple steel wire ropes. The frequency spectrum of the detection signal is used to detect abnormal stresses. The root mean square and center of gravity frequency of the detection signal are extracted to distinguish abnormal tensile and torsional stresses in multiple steel wire ropes and monitor its health.
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Crack Detection Method Based on the Poly-Magnetic Probe Structure
The detection of cracks has been a difficult task in the damage detection of ferromagnetic components. If the defects cannot be found and treated in time, the damage degree of the defects will gradually increase and there will be heavy losses. The signal amplitude of the cracks is low and the signal is complex, so the cracks are difficult to identify. Aiming to solve this problem, this paper explores the influence law of the probe magnetic conductor structure and sensor position on the detection results and proposes a method of detecting the cracks based on the poly-magnetic probe. An arc-shaped magnetic conductor structure is proposed to increase the magnetic flux density of the poly-magnetic probe. The effect of the position of the sensor on the defect detection is then studied, and a method of optimizing the poly-magnetic probe is proposed to improve the amplitude of the crack signal. Cracks with widths of 0.2 mm, 0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm are experimented respectively. It was shown in experiments that the crack with a width of 0.2 mm can be detected and the peak-to-peak amplitude of the defect detection signal of the optimized poly-magnetic probe method is 180%–472% higher.
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Crack Detection Method Based on the Poly-Magnetic Probe Structure
The detection of cracks has been a difficult task in the damage detection of ferromagnetic components. If the defects cannot be found and treated in time, the damage degree of the defects will gradually increase and there will be heavy losses. The signal amplitude of the cracks is low and the signal is complex, so the cracks are difficult to identify. Aiming to solve this problem, this paper explores the influence law of the probe magnetic conductor structure and sensor position on the detection results and proposes a method of detecting the cracks based on the poly-magnetic probe. An arc-shaped magnetic conductor structure is proposed to increase the magnetic flux density of the poly-magnetic probe. The effect of the position of the sensor on the defect detection is then studied, and a method of optimizing the poly-magnetic probe is proposed to improve the amplitude of the crack signal. Cracks with widths of 0.2 mm, 0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm are experimented respectively. It was shown in experiments that the crack with a width of 0.2 mm can be detected and the peak-to-peak amplitude of the defect detection signal of the optimized poly-magnetic probe method is 180%–472% higher.
- 2 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Fast Quantitative Method to Detect the Cross-Sectional Loss of Wire Rope Defects
The loss of metallic area is the most important factor affecting the quality of wire ropes. Therefore, it is very important to detect the loss of metallic area values of wire rope defects quickly and accurately. At present, the main flux detection approach is one of the most effective methods, and the detection signal is related directly to the metal cross-sectional area of the wire rope. However, when the defect width is less than a specific value, the existence of the leakage magnetic field means that the amount of the magnetic flux change is not only related to the loss of metallic area of the defect but also has a complex nonlinear relationship with the defect width. The resulting calculation is highly complex and means that the loss of metallic area cannot be determined quickly and quantitatively. This article presents an in-depth study of the theoretical basis of magnetic flux detection, analyzes the problems of the main magnetic flux detection method and their causes, and proposes a method to improve main magnetic flux detection using the axial magnetic flux density. Simulation analysis and experimental results show that the method presented in this article can be used to calculate the loss of metallic area values of defects quickly and accurately without the need for complex calculation processes.
- 2 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Fast Quantitative Method to Detect the Cross-Sectional Loss of Wire Rope Defects
The loss of metallic area is the most important factor affecting the quality of wire ropes. Therefore, it is very important to detect the loss of metallic area values of wire rope defects quickly and accurately. At present, the main flux detection approach is one of the most effective methods, and the detection signal is related directly to the metal cross-sectional area of the wire rope. However, when the defect width is less than a specific value, the existence of the leakage magnetic field means that the amount of the magnetic flux change is not only related to the loss of metallic area of the defect but also has a complex nonlinear relationship with the defect width. The resulting calculation is highly complex and means that the loss of metallic area cannot be determined quickly and quantitatively. This article presents an in-depth study of the theoretical basis of magnetic flux detection, analyzes the problems of the main magnetic flux detection method and their causes, and proposes a method to improve main magnetic flux detection using the axial magnetic flux density. Simulation analysis and experimental results show that the method presented in this article can be used to calculate the loss of metallic area values of defects quickly and accurately without the need for complex calculation processes.
- 7 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Noncontact Magnetostrictive Torsional Guided Wave Sensors for Small-Diameter Pipes
The magnetostrictive torsional wave sensors are focused on magnetostrictive patch transducer. These transducers use a material with a high magnetostrictive coefficient on the pipe surface to increase the excitation efficiency for detection. However, this approach loses the noncontact characteristic of the magnetostrictive guided waves. To enable noncontact detection in small-diameter pipes using torsional waves, a magnetostrictive torsional wave sensor with a tile-shaped magnet is designed in this paper. By optimizing the structure of the static magnetic field, the circumferential magnetic field of the pipe is enhanced. The amplitude and the signal-to-noise ratio of the guided waves are also improved. The tile-shaped magnet with shoving magnetic structure is used to realize a uniform circumferential magnetic field. A solenoid coil is used to provide the axial dynamic magnetic field to generate the torsional waves that are used to detect the pipes. In this paper, the principles of torsional wave sensors are studied first. The static magnetic field results for different structures are then analyzed via simulations. Finally, experiments show the magnetostrictive torsional wave sensors with the tile-shaped magnets can realize the excitation and detection of torsional waves in pipes, which can be used to detect the locations and sizes of defects in these pipes.
- 7 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Noncontact Magnetostrictive Torsional Guided Wave Sensors for Small-Diameter Pipes
The magnetostrictive torsional wave sensors are focused on magnetostrictive patch transducer. These transducers use a material with a high magnetostrictive coefficient on the pipe surface to increase the excitation efficiency for detection. However, this approach loses the noncontact characteristic of the magnetostrictive guided waves. To enable noncontact detection in small-diameter pipes using torsional waves, a magnetostrictive torsional wave sensor with a tile-shaped magnet is designed in this paper. By optimizing the structure of the static magnetic field, the circumferential magnetic field of the pipe is enhanced. The amplitude and the signal-to-noise ratio of the guided waves are also improved. The tile-shaped magnet with shoving magnetic structure is used to realize a uniform circumferential magnetic field. A solenoid coil is used to provide the axial dynamic magnetic field to generate the torsional waves that are used to detect the pipes. In this paper, the principles of torsional wave sensors are studied first. The static magnetic field results for different structures are then analyzed via simulations. Finally, experiments show the magnetostrictive torsional wave sensors with the tile-shaped magnets can realize the excitation and detection of torsional waves in pipes, which can be used to detect the locations and sizes of defects in these pipes.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 33-36
Nondestructive Testing of Elongated Ferromagnetic Members Based on Extruded Structure
The traditional electromagnetic nondestructive testing probe structure includes magnets and yokes, and forms an excitation circuit with the wire rope. The wire rope is excited to a near-saturation state. The magnetic sensor is used for qualitative or quantitative detection of leakage flux from defects. The yoke is essential in the traditional excitation circuit. However, the use of a yoke in a detection probe of such an excitation mechanism has a large volume and is heavy. Through simulation, we improved the magnetization direction and installation position of the permanent magnets. Without a yoke, the permanent magnets were placed in the direction of co-extrusion. The wire rope was excited to near saturation in the permanent-magnet part. However, there was no excitation in the center of the two permanent magnets. The magnetic sensor was placed in the center of two permanent magnets to pick up the magnetic-flux-leakage signal for nondestructive testing of the steel wire rope. This method simplifies the permanent-magnet magnetization. The excitation probe with the yoke removed was also reduced in volume and weight. Through experimental testing, it was proven that the proposed shoving-magnetic-field structure and the traditional detection structure have the same detection effect.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 7, 33-36
Nondestructive Testing of Elongated Ferromagnetic Members Based on Extruded Structure
The traditional electromagnetic nondestructive testing probe structure includes magnets and yokes, and forms an excitation circuit with the wire rope. The wire rope is excited to a near-saturation state. The magnetic sensor is used for qualitative or quantitative detection of leakage flux from defects. The yoke is essential in the traditional excitation circuit. However, the use of a yoke in a detection probe of such an excitation mechanism has a large volume and is heavy. Through simulation, we improved the magnetization direction and installation position of the permanent magnets. Without a yoke, the permanent magnets were placed in the direction of co-extrusion. The wire rope was excited to near saturation in the permanent-magnet part. However, there was no excitation in the center of the two permanent magnets. The magnetic sensor was placed in the center of two permanent magnets to pick up the magnetic-flux-leakage signal for nondestructive testing of the steel wire rope. This method simplifies the permanent-magnet magnetization. The excitation probe with the yoke removed was also reduced in volume and weight. Through experimental testing, it was proven that the proposed shoving-magnetic-field structure and the traditional detection structure have the same detection effect.
- 29 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (6) , 2678-2685
Determination of Natural Frequencies of Pipes Using White Noise for Magnetostrictive Longitudinal Guided-Wave Nondestructive Testing
Magnetostrictive guided waves are widely used in nondestructive testing and structural health monitoring of pipes to ensure their integrity. These guided waves are mechanical waves, and if the natural frequencies of the pipe are used as excitation frequencies, the mechanical vibration amplitude can be enhanced, which will then improve the amplitude of the guided waves. Comparison of various methods to determine the natural frequencies of pipes shows that the white noise signals remain relatively smooth in both time and frequency domains. White noise has wide bandwidth and uniform energy distribution. It does not require high energy within a short time period, so it is easy to generate. In this work, white noise is used to determine the natural frequencies of pipes. Comparison of the white noise spectra produced by analog and digital circuits shows that the energy spectrum of white noise produced by the analog circuit is high and uniform, so the analog circuit is used as the white noise source and this noise is loaded onto a magnetostrictive sensor. The detected signal spectrum is then analyzed and the frequencies with high power density spectra are determined to be the natural frequencies. The natural frequencies of the pipeline detected using white noise are compared with the results of modal analysis. The simulation results and the experimental results demonstrate that use of white noise allows the natural frequencies of pipes to be determined quickly and accurately. These natural frequencies can be used in magnetostrictive guided-wave nondestructive testing.
- 29 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (6) , 2678-2685
Determination of Natural Frequencies of Pipes Using White Noise for Magnetostrictive Longitudinal Guided-Wave Nondestructive Testing
Magnetostrictive guided waves are widely used in nondestructive testing and structural health monitoring of pipes to ensure their integrity. These guided waves are mechanical waves, and if the natural frequencies of the pipe are used as excitation frequencies, the mechanical vibration amplitude can be enhanced, which will then improve the amplitude of the guided waves. Comparison of various methods to determine the natural frequencies of pipes shows that the white noise signals remain relatively smooth in both time and frequency domains. White noise has wide bandwidth and uniform energy distribution. It does not require high energy within a short time period, so it is easy to generate. In this work, white noise is used to determine the natural frequencies of pipes. Comparison of the white noise spectra produced by analog and digital circuits shows that the energy spectrum of white noise produced by the analog circuit is high and uniform, so the analog circuit is used as the white noise source and this noise is loaded onto a magnetostrictive sensor. The detected signal spectrum is then analyzed and the frequencies with high power density spectra are determined to be the natural frequencies. The natural frequencies of the pipeline detected using white noise are compared with the results of modal analysis. The simulation results and the experimental results demonstrate that use of white noise allows the natural frequencies of pipes to be determined quickly and accurately. These natural frequencies can be used in magnetostrictive guided-wave nondestructive testing.
- 1 October 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (10) , 105119
A long time low drift integrator with temperature control
The output of an operational amplifier always contains signals that could not have been predicted, even with knowledge of the input and an accurately determined closed-loop transfer function. These signals lead to integrator zero-drift over time. A new type of integrator system with a long-term low-drift characteristic has therefore been designed. The integrator system is composed of a temperature control module and an integrator module. The aluminum printed circuit board of the integrator is glued to a thermoelectric cooler to maintain the electronic components at a stable temperature. The integration drift is automatically compensated using an analog-to-digital converter/proportional integration/digital-to-analog converter control circuit. Performance testing in a standard magnet shows that the proposed integrator, which has an integration time constant of 10 ms, has a low integration drift (<5 mV) over 1000 s after repeated measurements. The integrator can be used for magnetic flux measurements in most tokamaks and in the wire rope nondestructive test.
- 1 October 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (10) , 105119
A long time low drift integrator with temperature control
The output of an operational amplifier always contains signals that could not have been predicted, even with knowledge of the input and an accurately determined closed-loop transfer function. These signals lead to integrator zero-drift over time. A new type of integrator system with a long-term low-drift characteristic has therefore been designed. The integrator system is composed of a temperature control module and an integrator module. The aluminum printed circuit board of the integrator is glued to a thermoelectric cooler to maintain the electronic components at a stable temperature. The integration drift is automatically compensated using an analog-to-digital converter/proportional integration/digital-to-analog converter control circuit. Performance testing in a standard magnet shows that the proposed integrator, which has an integration time constant of 10 ms, has a low integration drift (<5 mV) over 1000 s after repeated measurements. The integrator can be used for magnetic flux measurements in most tokamaks and in the wire rope nondestructive test.