Shimin Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shimin Pan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Donglai Zhang
Harbin Institute of Technology
4 shared publications Enchao Zhang
Power Electronics and Electrical Drives Research Center, Harbin Institute of Technology Shenzhen Graduate School, Shenzhen, China
2 shared publications- Enchao Zhang
Power Electronic and Motion Control Research Center, Harbin Institute of Technology, Shenzhen, Shenzhen, China
2 shared publications - Tsz Hon Yuen
Monash University
2 shared publications - Wei Gao
Shenzhen Aerospace New Power Technology, Ltd., Shenzhen, China
2 shared publications - Xiaolan Yan
Power Electronic and Motion Control Research Center, Harbin Institute of Technology, Shenzhen, Shenzhen 518055, China
2 shared publications
Latest Publications
- Open Access
- 19 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 528-542
Posterior Security: Anonymity and Message Hiding of Standard Signatures
- 19 November 2025
- Published by Association for Computing Machinery (ACM)
- p. 528-542
Open AccessPosterior Security: Anonymity and Message Hiding of Standard Signatures
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Crack Detection Method Based on the Poly-Magnetic Probe Structure
The detection of cracks has been a difficult task in the damage detection of ferromagnetic components. If the defects cannot be found and treated in time, the damage degree of the defects will gradually increase and there will be heavy losses. The signal amplitude of the cracks is low and the signal is complex, so the cracks are difficult to identify. Aiming to solve this problem, this paper explores the influence law of the probe magnetic conductor structure and sensor position on the detection results and proposes a method of detecting the cracks based on the poly-magnetic probe. An arc-shaped magnetic conductor structure is proposed to increase the magnetic flux density of the poly-magnetic probe. The effect of the position of the sensor on the defect detection is then studied, and a method of optimizing the poly-magnetic probe is proposed to improve the amplitude of the crack signal. Cracks with widths of 0.2 mm, 0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm are experimented respectively. It was shown in experiments that the crack with a width of 0.2 mm can be detected and the peak-to-peak amplitude of the defect detection signal of the optimized poly-magnetic probe method is 180%–472% higher.
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Crack Detection Method Based on the Poly-Magnetic Probe Structure
The detection of cracks has been a difficult task in the damage detection of ferromagnetic components. If the defects cannot be found and treated in time, the damage degree of the defects will gradually increase and there will be heavy losses. The signal amplitude of the cracks is low and the signal is complex, so the cracks are difficult to identify. Aiming to solve this problem, this paper explores the influence law of the probe magnetic conductor structure and sensor position on the detection results and proposes a method of detecting the cracks based on the poly-magnetic probe. An arc-shaped magnetic conductor structure is proposed to increase the magnetic flux density of the poly-magnetic probe. The effect of the position of the sensor on the defect detection is then studied, and a method of optimizing the poly-magnetic probe is proposed to improve the amplitude of the crack signal. Cracks with widths of 0.2 mm, 0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm are experimented respectively. It was shown in experiments that the crack with a width of 0.2 mm can be detected and the peak-to-peak amplitude of the defect detection signal of the optimized poly-magnetic probe method is 180%–472% higher.
- 30 November 2022
- Published by Elsevier in Future Generation Computer Systems
- Vol. 141, 448-461
Practical fully leakage resilient signatures with auxiliary inputs
- 30 November 2022
- Published by Elsevier in Future Generation Computer Systems
- Vol. 141, 448-461
Practical fully leakage resilient signatures with auxiliary inputs
- 2 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Fast Quantitative Method to Detect the Cross-Sectional Loss of Wire Rope Defects
The loss of metallic area is the most important factor affecting the quality of wire ropes. Therefore, it is very important to detect the loss of metallic area values of wire rope defects quickly and accurately. At present, the main flux detection approach is one of the most effective methods, and the detection signal is related directly to the metal cross-sectional area of the wire rope. However, when the defect width is less than a specific value, the existence of the leakage magnetic field means that the amount of the magnetic flux change is not only related to the loss of metallic area of the defect but also has a complex nonlinear relationship with the defect width. The resulting calculation is highly complex and means that the loss of metallic area cannot be determined quickly and quantitatively. This article presents an in-depth study of the theoretical basis of magnetic flux detection, analyzes the problems of the main magnetic flux detection method and their causes, and proposes a method to improve main magnetic flux detection using the axial magnetic flux density. Simulation analysis and experimental results show that the method presented in this article can be used to calculate the loss of metallic area values of defects quickly and accurately without the need for complex calculation processes.
- 2 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Fast Quantitative Method to Detect the Cross-Sectional Loss of Wire Rope Defects
The loss of metallic area is the most important factor affecting the quality of wire ropes. Therefore, it is very important to detect the loss of metallic area values of wire rope defects quickly and accurately. At present, the main flux detection approach is one of the most effective methods, and the detection signal is related directly to the metal cross-sectional area of the wire rope. However, when the defect width is less than a specific value, the existence of the leakage magnetic field means that the amount of the magnetic flux change is not only related to the loss of metallic area of the defect but also has a complex nonlinear relationship with the defect width. The resulting calculation is highly complex and means that the loss of metallic area cannot be determined quickly and quantitatively. This article presents an in-depth study of the theoretical basis of magnetic flux detection, analyzes the problems of the main magnetic flux detection method and their causes, and proposes a method to improve main magnetic flux detection using the axial magnetic flux density. Simulation analysis and experimental results show that the method presented in this article can be used to calculate the loss of metallic area values of defects quickly and accurately without the need for complex calculation processes.
- 26 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 54 (11) , 1-6
Nondestructive Testing for Shallow Defect of Ferromagnetic Objects Based on Magnetic Probe Structure
The magnetic flux leakage (MFL) technology is one of the most widely used electromagnetic nondestructive testing techniques. To magnetize the detected object near to saturated flux density, the excitation mechanism is heavy and large in the MFL technology. A simple and portable magnetic detector device for shallow defect of ferromagnetic objects based on the magnetic probe structure is designed in this paper. The proposed magnetic detector is very light, cheap, and easy to design and manufacture. The magnetic detector can make the qualitative and quantitative evaluation for shallow defect of ferromagnetic objects. In steel ribbon test, the maximum relative error of quantitative test results is less than 5% by the proposed magnetic detector device. In this paper, the application of the magnetic detection method for wire rope is proposed. By the proposed method, qualitative and positional detection of the wire rope defects can be easily achieved.
- 26 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 54 (11) , 1-6
Nondestructive Testing for Shallow Defect of Ferromagnetic Objects Based on Magnetic Probe Structure
The magnetic flux leakage (MFL) technology is one of the most widely used electromagnetic nondestructive testing techniques. To magnetize the detected object near to saturated flux density, the excitation mechanism is heavy and large in the MFL technology. A simple and portable magnetic detector device for shallow defect of ferromagnetic objects based on the magnetic probe structure is designed in this paper. The proposed magnetic detector is very light, cheap, and easy to design and manufacture. The magnetic detector can make the qualitative and quantitative evaluation for shallow defect of ferromagnetic objects. In steel ribbon test, the maximum relative error of quantitative test results is less than 5% by the proposed magnetic detector device. In this paper, the application of the magnetic detection method for wire rope is proposed. By the proposed method, qualitative and positional detection of the wire rope defects can be easily achieved.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 8105-8110
Position-sensorless for wire rope distance measurement and nondestructive testing
Devices used for nondestructive testing of wire rope often include a guide wheel, which is connected to an encoder to measure the running distance of the wire rope and to provide information about defect positions. However, in use, problems with the guide wheel such as contact jittering, slipping, idling, and bouncing cause encoder pulse loss, which affects the location measurements and quantitative analysis of the defects. Also, the wire rope running at high speed is a safety problem. However, these issues can be avoided by using the unique winding of the wire rope to provide a strand wave signal. Using wave signal processing, the distance traveled by the wire rope can be measured. Then, a phase-locked loop locks and multiplies the frequency of the strand wave signal. The multiple-frequency signal is used as a trigger signal for equal distance sampling of the wire rope. This method not only replaces the use of guide wheels and encoders when the wire rope is running at uniform velocity, but also improves the precision of the positioning and quantitative analysis of defects.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 8105-8110
Position-sensorless for wire rope distance measurement and nondestructive testing
Devices used for nondestructive testing of wire rope often include a guide wheel, which is connected to an encoder to measure the running distance of the wire rope and to provide information about defect positions. However, in use, problems with the guide wheel such as contact jittering, slipping, idling, and bouncing cause encoder pulse loss, which affects the location measurements and quantitative analysis of the defects. Also, the wire rope running at high speed is a safety problem. However, these issues can be avoided by using the unique winding of the wire rope to provide a strand wave signal. Using wave signal processing, the distance traveled by the wire rope can be measured. Then, a phase-locked loop locks and multiplies the frequency of the strand wave signal. The multiple-frequency signal is used as a trigger signal for equal distance sampling of the wire rope. This method not only replaces the use of guide wheels and encoders when the wire rope is running at uniform velocity, but also improves the precision of the positioning and quantitative analysis of defects.