HJHayong Jung

Hayong Jung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hayong Jung has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Erratum to “Highly Integrated Multiplexing and Buffering Electronics for Large Aperture Ultrasonic Arrays”

    by Robert Wodnicki, Haochen Kang, Di Li, Douglas N. Stephens, Hayong Jung, Yizhe Sun, Ruimin Chen, Lai-Ming Jiang, Nestor E. Cabrera-Munoz, Josquin Foiret, et al.

    [This corrects the article DOI: 10.34133/2022/9870386.].


  • Co-Integrated PIN-PMN-PT 2-D Array and Transceiver Electronics by Direct Assembly Using a 3-D Printed Interposer Grid Frame

    by Robert Wodnicki, Haochen Kang, Ruimin Chen, Nestor E. Cabrera-Munoz, Hayong Jung, Laiming Jiang, Josquin Foiret, Yu Liu, Victoria Chiu, Douglas N. Stephens, et al.

    Tiled modular 2-D ultrasound arrays have the potential for realizing large apertures for novel diagnostic applications. This work presents an architecture for fabrication of tileable 2-D array modules implemented using 1-3 composites of high-bandwidth (BW) PIN-PMN-PT single-crystal piezoelectric material closely coupled with high-voltage CMOS application-specific integrated circuit (ASIC) electronics for buffering and multiplexing functions. The module, which is designed to be operated as a λ-pitch 1.75-D array, benefits from an improved electromechanical coupling coefficient and increased Curie temperature and is assembled directly on top of the ASIC silicon substrate using an interposer backing. The interposer consists of a novel 3-D printed acrylic frame that is filled with conducting and acoustically absorbing silver epoxy material. The ASIC comprises a high-voltage switching matrix with locally integrated buffering and is interfaced to a Verasonics Vantage 128, using a local field programmable gate array (FPGA) controller. Multiple prototype 5 × 6 element array modules have been fabricated by this process. The combined acoustic array and ASIC module was configured electronically by programming the switches to operate as a 1-D array with elements grouped in elevation for imaging and pulse-echo testing. The resulting array configuration had an average center frequency of 4.55 MHz, azimuthal element pitch of 340 μm, and exhibited average -20-dB pulsewidth of 592 ns and average -6-dB fractional BW of 77%.


  • Open Access

    Fabrication and Characterization of a Miniaturized 15-MHz Side-Looking Phased-Array Transducer Catheter

    by Nestor E. Cabrera-Munoz, Payam Eliahoo, Robert Wodnicki, Hayong Jung, Chi Tat Chiu, Jay A. Williams, Hyung Ham Kim, Qifa Zhou, Guang-Zhong Yang, K. Kirk Shung

    This paper describes the development of a miniaturized 15-MHz side-looking phased-array transducer catheter. The array features a 2-2 linear composite with 64 piezoelectric elements mechanically diced into a piece of PMN-30%PT single crystal and separated by non-conductive epoxy kerfs at a 50-μm pitch, yielding a total active aperture of 3.2 mm in the azimuth direction and 1.8 mm in the elevation direction, with an elevation natural focal depth of 8.1 mm. The array includes non-conductive epoxy backing and two front matching layers. A custom flexible circuit connects the array piezoelectric elements to a bundle of 64 individual 48-AWG micro-coaxial cables enclosed within a 1.5-m long 10F catheter. Performance characterization was evaluated via finite element analysis simulations and afterwards compared against obtained measurement results, which showed an average center frequency of 17.7 MHz, an average bandwidth of 52.2% at -6 dB, and crosstalk less than -30 dB. Imaging of a tungsten fine-wire phantom resulted in axial and lateral spatial resolutions of approximately 90 μm and 420 ìm, respectively. The imaging capability was further evaluated with colorectal tissue-mimicking phantoms, demonstrating the potential suitability of the proposed phased-array transducer for the intraoperative assessment of surgical margins during minimally invasive colorectal surgery procedures.


  • CMOS High-Voltage Analog 1–64 Multiplexer/Demultiplexer for Integrated Ultrasound Guided Breast Needle Biopsy

    by Hayong Jung, Robert Wodnicki, Hae Gyun Lim, Chi Woo Yoon, Bong Jin Kang, Changhan Yoon, Changyang Lee, Jae Youn Hwang, Hyung Ham Kim, Hojong Choi, et al.

    Ultrasound guided needle biopsy is an important method for collection of breast cancer tissue. In this paper, we report on the design and testing of a high-voltage 1 to 64 Multiplexer/Demultiplexer (MUX/De-MUX) integrated circuit (IC) for ultrasound-guided breast biopsy applications implemented in a high-voltage CMOS process. The IC is intended to be incorporated inside the breast biopsy needle and is designed to fit inside the needle inner diameter of 2.38 mm. The MUX/De-MUX electronics are made up of three parts, including a low-voltage 6 to 64 decoder, a level shifter to convert from low voltage to high voltage, and analog high-voltage switches. Experimental results show a -3-dB bandwidth of over 70 MHz, Rds (on) of 140 Ω, -2.279-dB insertion loss, and -17.5-dB off isolation at 70 MHz with low-voltage input. Finally, we present results obtained via synthetic aperture imaging using the fabricated MUX/De-Mux device and a high-frequency ultrasound array. This device and technique hold promise for high-frequency imaging probes where a limited number of elements are used and the depth of penetration is short such as in breast biopsy and intravascular applications.