RWRobert Wodnicki

Robert Wodnicki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robert Wodnicki has a total of 80 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Volumetric Ultrasound Imaging Based on 4096-Element Large-Aperture 2-D Array

    by Baoqiang Liu, Robert Wodnicki, Josquin Foiret, X. Sun, Junhang Zhang, Christophe Notard, Mathieu Legros, Qifa Zhou, Katherine W. Ferrara

    Large aperture 2D arrays improve ultrasound imaging by increasing lateral resolution at depth, owing to the inverse relationship between beamwidth and aperture size, and by enabling higher contrast resolution through electronic focusing in elevation. We present a 4,096-element (128 × 32) large-aperture 2D ultrasound array with element pitches of 0.65 mm (azimuth) and 0.5 mm (elevation), operating at a 2.4 MHz center frequency with over 80% –6 dB bandwidth. The active aperture measures 83.2 mm × 16 mm and is integrated with custom multiplexing ASICs, local preamplifiers for sensitivity enhancement, and an FPGA-based control interface, forming a fully reconfigurable imaging platform. Phantom experiments using a commercial CIRS 054GS tissue-mimicking phantom demonstrated penetration beyond 120 mm. The system achieved axial and lateral resolutions of 0.40 mm and 0.46 mm respectively at depths of 51 mm, with a maximum CNR of 2.13 and gCNR of 0.94 for cyst targets. These results validate the effectiveness of the large aperture 2D array for high-resolution volumetric ultrasound imaging and underscore the promise for future clinical translation.

  • Handheld Large 2-D Array With Azimuthal Planewave and Row-Multiplexed Elevation Beamforming Enabled by Local ASIC Electronics

    by Robert Wodnicki, Josquin Foiret, Baoqiang Liu, Ning Lu, Xin Sun, Junhang Zhang, Haochen Kang, Lei Fu, Christophe Notard, Mathieu Legros, et al.

    Large aperture 2D arrays benefit from improved lateral resolution at depth, due to the dependence of beamwidth on the inverse of the aperture width, and improved contrast resolution due to electronic focusing. We have been developing modular large aperture multi-row 1,024 (64 azimuth × 16 elevation) element, 2D arrays based on custom-designed and locally integrated Application Specific Integrated Circuit (ASIC) multiplexing devices. The implemented handheld large array prototype probe for human imaging consists of multiple rows with multiplexed synthetic aperture in elevation and planewave transmits in azimuth. The pitch of the acoustic array is 650 μm in azimuth by 1,000 μm in elevation, with a 2.4 MHz (FBW=88%) center frequency and total active aperture of 42 mm × 16 mm. We interfaced the large aperture array and multiplexing ASICs, along with local preamplifier devices for improved sensitivity, and a local FPGA for digital ASIC control, to a configurable ultrasound imaging platform and demonstrate 2D orthogonal and full 3D-beamformed imaging. The implemented imaging prototype includes local buffering for improved sensitivity of the high impedance 2D array elements, and realizes penetration down to 140 mm, experimental lateral/axial resolution at 67 mm of 1.1 mm/0.4 mm, and maximum experimental CNR of 2.1 for 8 mm cylindrical cysts, and 1.7 for 10 mm spherical cysts. We demonstrate in-vivo imaging of liver in human volunteers utilizing a hermetically-sealed and safety-validated handheld prototype of the large 2D array. Preliminary results are promising for clinical imaging in future studies.


  • High frequency ultrasound 2D array design and fabrication with 3D printed interposers at 200 μm pitch

    by Yizhe Sun, Robert Wodnicki, Xin Sun, Haochen Kang, Baoqiang Liu, U-Wai Lok, Shigao Chen, Qifa Zhou


  • High-Frequency Wearable Ultrasound Array Belt for Small Animal Echocardiography

    by Yushun Zeng, Xin Sun, Junhang Zhang, Chi-Feng Chang, Baoqiang Liu, Chen Gong, Jie Ji, Bryan Zhen Zhang, Yujie Wang, Matthew Xinhu Ren, et al.

    Wearable ultrasound has been widely developed for long-term, continuous imaging without the need for bulky system manipulation and repeated manual locating. To potentially lead to more accurate and reliable imaging monitoring, this work presents the design, fabrication, and evaluation of a novel high-frequency wearable ultrasound array belt (WUAB) for small animal echocardiography. The fabrication process involved precise dicing technology for a λ-pitch design. The 20 MHz WUAB consists of two matching layers, piezoelectric composite with 128 channels, customized flexible circuit substrate, acoustic backing layer, and customized belt structure with designed end tip and insertion point for wearability. The resulting WUAB demonstrates sensitivity of -5.69 ± 2.5 dB and fractional bandwidth of 57 ± 5 %. In vivo experiments on rat model showed expected echocardiography and B-mode images of rat heart. These results represent significant promise for future longitudinal studies in small animals and real-time physiological monitoring.


  • Open Access

    Fast volumetric ultrasound facilitates high-resolution 3D mapping of tissue compartments

    by Eun-Yeong Park, Xiran Cai, Josquin Foiret, Hanna Bendjador, Dongwoon Hyun, Brett Z. Fite, Robert Wodnicki, Jeremy J. Dahl, Robert D. Boutin, Katherine W. Ferrara

    Volumetric ultrasound imaging has the potential for operator-independent acquisition and enhanced field of view. Panoramic acquisition has many applications across ultrasound; spanning musculoskeletal, liver, breast, and pediatric imaging; and image-guided therapy. Challenges in high-resolution human imaging, such as subtle motion and the presence of bone or gas, have limited such acquisition. These issues can be addressed with a large transducer aperture and fast acquisition and processing. Programmable, ultrafast ultrasound scanners with a high channel count provide an unprecedented opportunity to optimize volumetric acquisition. In this work, we implement nonlinear processing and develop distributed beamformation to achieve fast acquisition over a 47-centimeter aperture. As a result, we achieve a 50-micrometer −6-decibel point spread function at 5 megahertz and resolve in-plane targets. A large volume scan of a human limb is completed in a few seconds, and in a 2-millimeter dorsal vein, the image intensity difference between the vessel center and surrounding tissue was ~50 decibels, facilitating three-dimensional reconstruction of the vasculature.


  • 2-D Array Design and Fabrication With Pitch-Shifting Interposer at Frequencies From 4 MHz up to 10 MHz

    by Haochen Kang, Yizhe Sun, Robert Wodnicki, Qingqing He, Yushun Zeng, Gengxi Lu, Jung-Yeol Yeom, Yang Yang, Qifa Zhou

    High element density and strict constraints of the element’s size have significantly limited the design and fabrication of 2-D ultrasonic arrays, especially fully sampled 2-D arrays. Recently, 3-D printing technology has been one of the most rapidly developing fields. Along with the great progress of 3-D printing technology, complex and detailed 3-D structures have become readily available with a short iteration cycle, which allows us to reduce the complexity of routing and helps to ameliorate assembly problems in 2-D ultrasound array fabrication. In this work, we designed and fabricated 2-D ultrasound arrays for an array of applications with a pitch-shifting interposer, which allowed us to fit different array designs with the same circuit design and significantly reduce the requirements in routing and connection for 2-D array fabrication at frequencies from 4 to 10 MHz. Results demonstrated that this design would make 2-D arrays more available and affordable.


  • Open Access

    Highly Integrated Multiplexing and Buffering Electronics for Large Aperture Ultrasonic Arrays

    by Robert Wodnicki, Haochen Kang, Di Li, Douglas N. Stephens, Hayong Jung, Yizhe Sun, Ruimin Chen, Lai-Ming Jiang, Nestor E. Cabrera-Munoz, Josquin Foiret, et al.

    Large aperture ultrasonic arrays can be implemented by tiling together multiple pretested modules of high-density acoustic arrays with closely integrated multiplexing and buffering electronics to form a larger aperture with high yield. These modular arrays can be used to implement large 1.75D array apertures capable of focusing in elevation for uniform slice thickness along the axial direction which can improve image contrast. An important goal for large array tiling is obtaining high yield and sensitivity while reducing extraneous image artifacts. We have been developing tileable acoustic-electric modules for the implementation of large array apertures utilizing Application Specific Integrated Circuits (ASICs) implemented using 0.35μm high voltage (50 V) CMOS. Multiple generations of ASICs have been designed and tested. The ASICs were integrated with high-density transducer arrays for acoustic testing and imaging. The modules were further interfaced to a Verasonics Vantage imaging system and were used to image industry standard ultrasound phantoms. The first-generation modules comprise ASICs with both multiplexing and buffering electronics on-chip and have demonstrated a switching artifact which was visible in the images. A second-generation ASIC design incorporates low switching injection circuits which effectively mitigate the artifacts observed with the first-generation devices. Here, we present the architecture of the two ASIC designs and module types as well imaging results that demonstrate reduction in switching artifacts for the second-generation devices.


  • Open Access

    Erratum to “Highly Integrated Multiplexing and Buffering Electronics for Large Aperture Ultrasonic Arrays”

    by Robert Wodnicki, Haochen Kang, Di Li, Douglas N. Stephens, Hayong Jung, Yizhe Sun, Ruimin Chen, Lai-Ming Jiang, Nestor E. Cabrera-Munoz, Josquin Foiret, et al.

    [This corrects the article DOI: 10.34133/2022/9870386.].


  • Recent progress in 3D printing piezoelectric materials for biomedical applications

    by Yushun Zeng, Laiming Jiang, Qingqing He, Robert Wodnicki, Yang Yang, Yong Chen, Qifa Zhou

    Three-dimensional (3D) printing technology has attracted significant attention for fabricating piezoelectric materials due to its high efficiency and capability to produce complex structures. Motivated by the desire to address limitations in conventional methods for fabricating piezoelectric materials, this review first introduces commonly used 3D-printing technologies to fabricate piezoelectric materials. The advantages of the technologies are evaluated. Subsequently, typical piezoelectric materials produced by 3D-printing methods are specifically discussed. The properties of the printed materials, such as dielectric and piezoelectric properties, are presented. Significant applications of 3D-printed piezoelectric materials are further explored, highlighting the potential of fabricating 3D-printed piezoelectric materials for biomedical applications. Finally, future directions and opportunities for 3D-printed piezoelectric materials are highlighted.


  • 2-D Ultrasonic Array-Based Optical Coherence Elastography

    by Haochen Kang, Xuejun Qian, Ruimin Chen, Robert Wodnicki, Yizhe Sun, Runze Li, Yan Li, K. Kirk Shung, Zhongping Chen, Qifa Zhou

    Acoustic radiation force optical coherence elastography (ARF-OCE) has been successfully implemented to characterize the biomechanical properties of soft tissues, such as the cornea and the retina, with high resolution using single-element ultrasonic transducers for ARF excitation. Most currently proposed OCE techniques, such as air puff and ARF, have less capability to control the spatiotemporal information of the induced region of deformation, resulting in limited accuracy and low temporal resolution of the shear wave elasticity imaging. In this study, we propose a new method called 2-D ultrasonic array-based OCE imaging, which combines the advantages of 3-D dynamic electronic steering of the 2-D ultrasonic array and high-resolution optical coherence tomography (OCT). The 3-D steering capability of the 2-D array was first validated using a hydrophone. Then, the combined 2-D ultrasonic array OCE system was calibrated using a homogenous phantom, followed by an experiment on ex vivo rabbit corneal tissue. The results demonstrate that our newly developed 2-D ultrasonic array-based OCE system has the capability to map tissue biomechanical properties accurately, and therefore, has the potential to be a vital diagnostic tool in ophthalmology.