Jeppe Barckman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jeppe Barckman has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Jens-Christian Beuke
Department of Orthopaedic Surgery, Kolding Hospital, Kolding, Denmark
1 shared publicationJoan E Bechtold
Orthopaedic Biomechanics Laboratory, Excelen and Minneapolis Medical Research Foundations, University of Minnesota, Minneapolis MN 55415, Minnesota, USA
1 shared publicationJorgen Baas
Orthopaedic Research Laboratory, Aarhus University Hospital, Denmark
1 shared publication- Juozas Petruskevicius
Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
1 shared publication K. Larsen
From the Department of Orthopaedics, Section of Hand Surgery, Department of Radiology and Orthopaedic Research Unit Regional Hospital Holstebro, and Department of Orthopaedics, Regional Hospital Herning, Denmark
1 shared publication- Kjeld Søballe
Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus, Denmark
1 shared publication
Latest Publications
- 1 September 2026
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 108-B (9) , 1182-1189
Locking plate fixation compared with tension-band wiring for patellar fractures: a multicentre randomized controlled trial
Aims: Patellar fractures are associated with considerable postoperative morbidity, and tension-band wiring has high complication rates and suboptimal outcomes. Locking plate fixation is a recent surgical innovation which confers superior biomechanical stability. However, there is little information about the clinical outcomes of this method of treatment. The aim of this study was to compare locking plate fixation with tension-band wiring in patients requiring surgical treatment for a patellar fracture. Methods: In this patient- and assessor-blinded, multicentre randomized trial, 122 adults with a displaced patellar fracture were assigned 1:1 to locking plate fixation or tension-band wiring. The primary outcome was patient-reported knee function measured by the five sub-scales of the Knee Injury and Osteoarthritis Outcome Score (KOOS) at 12 months. Superiority was predefined as a statistically significant difference in at least three KOOS sub-scales exceeding the minimal clinically important difference (pain 10, symptoms 9, activities of daily living 6, sport and recreation 10, quality of life 10). Secondary outcomes included additional clinical and functional outcomes. Analyses were performed according to the intention-to-treat principle. Results: A total of 63 patients were assigned to locking plate fixation and 59 to tension-band wiring; 57 (90.5%) and 52 (88.1%), respectively, completed 12-month follow-up. Locking plate fixation resulted in statistically significant and clinically meaningful improvements in three KOOS sub-scales at this time: symptoms (mean difference -10.4 (95% CI -16.4 to -4.4)), sport and recreation (-14.1 (95% CI -24.7 to -3.4)), and quality of life (-10.9 (95% CI -19.0 to -2.7)). Removal of hardware, failure of fixation, and reoperation occurred more frequently after tension-band wiring. Conclusion: Locking plate fixation yielded superior patient-reported outcomes compared with tension-band wiring at 12 months, providing high-level evidence supporting the use of plate fixation as a preferred surgical technique for patients with a displaced patellar fracture. Cite this article: Bone Joint J 2026;108-B(9):1182–1189.
- 1 September 2026
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 108-B (9) , 1182-1189
Locking plate fixation compared with tension-band wiring for patellar fractures: a multicentre randomized controlled trial
Aims: Patellar fractures are associated with considerable postoperative morbidity, and tension-band wiring has high complication rates and suboptimal outcomes. Locking plate fixation is a recent surgical innovation which confers superior biomechanical stability. However, there is little information about the clinical outcomes of this method of treatment. The aim of this study was to compare locking plate fixation with tension-band wiring in patients requiring surgical treatment for a patellar fracture. Methods: In this patient- and assessor-blinded, multicentre randomized trial, 122 adults with a displaced patellar fracture were assigned 1:1 to locking plate fixation or tension-band wiring. The primary outcome was patient-reported knee function measured by the five sub-scales of the Knee Injury and Osteoarthritis Outcome Score (KOOS) at 12 months. Superiority was predefined as a statistically significant difference in at least three KOOS sub-scales exceeding the minimal clinically important difference (pain 10, symptoms 9, activities of daily living 6, sport and recreation 10, quality of life 10). Secondary outcomes included additional clinical and functional outcomes. Analyses were performed according to the intention-to-treat principle. Results: A total of 63 patients were assigned to locking plate fixation and 59 to tension-band wiring; 57 (90.5%) and 52 (88.1%), respectively, completed 12-month follow-up. Locking plate fixation resulted in statistically significant and clinically meaningful improvements in three KOOS sub-scales at this time: symptoms (mean difference -10.4 (95% CI -16.4 to -4.4)), sport and recreation (-14.1 (95% CI -24.7 to -3.4)), and quality of life (-10.9 (95% CI -19.0 to -2.7)). Removal of hardware, failure of fixation, and reoperation occurred more frequently after tension-band wiring. Conclusion: Locking plate fixation yielded superior patient-reported outcomes compared with tension-band wiring at 12 months, providing high-level evidence supporting the use of plate fixation as a preferred surgical technique for patients with a displaced patellar fracture. Cite this article: Bone Joint J 2026;108-B(9):1182–1189.
- Open Access
- 16 January 2013
- Published by Bentham Science Publishers Ltd. in The Open Orthopaedics Journal
- Vol. 7 (1) , 18-24
Periosteal Augmentation of Allograft Bone and its Effect on Implant Fixation - An Experimental Study on 12 Dogs§
Purpose: Periosteum provides essential cellular and biological components necessary for fracture healing and bone repair. We hypothesized that augmenting allograft bone by adding fragmented autologous periosteum would improve fixation of grafted implants. Methods: In each of twelve dogs, we implanted two unloaded cylindrical (10 mm x 6 mm) titanium implants into the distal femur. The implants were surrounded by a 2.5-mm gap into which morselized allograft bone with or without addition of fragmented autologous periosteum was impacted. After four weeks, the animals were euthanized and the implants were evaluated by histomorphometric analysis and mechanical push-out test. Results: Although less new bone was found on the implant surface and increased volume of fibrous tissue was present in the gap around the implant, no difference was found between treatment groups regarding the mechanical parameters. Increased new bone formation was observed in the immediate vicinity of the periosteum fragments within the bone graft. Conclusion: The method for periosteal augmentation used in this study did not alter the mechanical fixation although osseointegration was impaired. The observed activity of new bone formation at the boundary of the periosteum fragments may indicate maintained bone stimulating properties of the transplanted cambium layer. Augmenting the bone graft by smaller fragments of periosteum, isolated cambium layer tissue or cultured periosteal cells could be studied in the future.
- 16 January 2013
- Published by Bentham Science Publishers Ltd. in The Open Orthopaedics Journal
- Vol. 7 (1) , 18-24
Open AccessPeriosteal Augmentation of Allograft Bone and its Effect on Implant Fixation - An Experimental Study on 12 Dogs§
Purpose: Periosteum provides essential cellular and biological components necessary for fracture healing and bone repair. We hypothesized that augmenting allograft bone by adding fragmented autologous periosteum would improve fixation of grafted implants. Methods: In each of twelve dogs, we implanted two unloaded cylindrical (10 mm x 6 mm) titanium implants into the distal femur. The implants were surrounded by a 2.5-mm gap into which morselized allograft bone with or without addition of fragmented autologous periosteum was impacted. After four weeks, the animals were euthanized and the implants were evaluated by histomorphometric analysis and mechanical push-out test. Results: Although less new bone was found on the implant surface and increased volume of fibrous tissue was present in the gap around the implant, no difference was found between treatment groups regarding the mechanical parameters. Increased new bone formation was observed in the immediate vicinity of the periosteum fragments within the bone graft. Conclusion: The method for periosteal augmentation used in this study did not alter the mechanical fixation although osseointegration was impaired. The observed activity of new bone formation at the boundary of the periosteum fragments may indicate maintained bone stimulating properties of the transplanted cambium layer. Augmenting the bone graft by smaller fragments of periosteum, isolated cambium layer tissue or cultured periosteal cells could be studied in the future.
- 17 August 2009
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 34 (5) , 627-630
Cost-effectiveness of MRI in managing suspected scaphoid fractures
In a cost-effectiveness study, we compared a treatment algorithm using repeated radiological examination with an algorithm using subacute MRI in patients with clinical signs of scaphoid fracture but normal initial radiography. Twenty-seven patients were included in both groups, and MRI reduced the immobilisation time from 20 days (range, 6–54) to 4 days (range, 1–19) and sick leave from 27 days (1–92) to 11 days (0–28). Use of MRI increased hospital costs by €151 (PP<0.05), making MRI cost-effective in the treatment of suspected scaphoid fractures.
- 17 August 2009
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 34 (5) , 627-630
Cost-effectiveness of MRI in managing suspected scaphoid fractures
In a cost-effectiveness study, we compared a treatment algorithm using repeated radiological examination with an algorithm using subacute MRI in patients with clinical signs of scaphoid fracture but normal initial radiography. Twenty-seven patients were included in both groups, and MRI reduced the immobilisation time from 20 days (range, 6–54) to 4 days (range, 1–19) and sick leave from 27 days (1–92) to 11 days (0–28). Use of MRI increased hospital costs by €151 (PP<0.05), making MRI cost-effective in the treatment of suspected scaphoid fractures.