Ignacio Gil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ignacio Gil has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Raúl Fernández-García
Department of Electronic Engineering, Universitat Politècnica de Catalunya, Terrassa, Spain
67 shared publications - Jordi Bonache
Universitat Autònoma de Barcelona, Bellaterra, Spain
34 shared publications - Ferran Martin
Universitat Autónoma de Barcelona
31 shared publications - Marc Martínez-Estrada
Departament of Electronic Engineering, Universitat Politecnica de Catalunya, ESEIAAT, Colom 1, 08222 Terrassa, Spain
16 shared publications J. Garcia-Garcia
Departament d'Enginyeria Electrònica. Universitat Autònoma de Barcelona. 08193 BELLATERRA (Barcelona). Spain. Phone: 34935813522; Fax: 34935812600
13 shared publicationsM. Sorolla
13 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (18) , 27129-27137
Wearable Strain Sensing Using Near-Field Coupled Zigzag Metamaterial Absorber
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (18) , 27129-27137
Open AccessWearable Strain Sensing Using Near-Field Coupled Zigzag Metamaterial Absorber
- Open Access
Flexible Resistive Sensors for Wearable and Ergonomics Applications: A Systematic Review
Flexible resistive sensors are promising for wearable and ergonomic applications because they can be easily fabricated on textiles or flexible substrates and enable real-time monitoring of human movement and posture, especially in health monitoring systems. This review presents an overview of recent developments in an interdisciplinary way and summarises advances in materials, fabrication methods, and ergonomic applications. A structured literature search was conducted across major databases, including only studies focused on resistive sensing. The selected works were analysed in terms of conductive materials, fabrication techniques (e.g., direct ink writing (DIW) and textile-based methods), and their integration into wearable systems. Flexible resistive sensors are widely used for monitoring joint motion, posture, and physiological signals in healthcare and industrial environments. However, several challenges remain, including limitations in sensitivity, signal stability, material durability, and the need for reliable calibration in real-world conditions. This review highlights current progress and existing limitations and outlines future research directions toward more robust and user-friendly wearable sensing solutions for ergonomic applications.
Open AccessFlexible Resistive Sensors for Wearable and Ergonomics Applications: A Systematic Review
Flexible resistive sensors are promising for wearable and ergonomic applications because they can be easily fabricated on textiles or flexible substrates and enable real-time monitoring of human movement and posture, especially in health monitoring systems. This review presents an overview of recent developments in an interdisciplinary way and summarises advances in materials, fabrication methods, and ergonomic applications. A structured literature search was conducted across major databases, including only studies focused on resistive sensing. The selected works were analysed in terms of conductive materials, fabrication techniques (e.g., direct ink writing (DIW) and textile-based methods), and their integration into wearable systems. Flexible resistive sensors are widely used for monitoring joint motion, posture, and physiological signals in healthcare and industrial environments. However, several challenges remain, including limitations in sensitivity, signal stability, material durability, and the need for reliable calibration in real-world conditions. This review highlights current progress and existing limitations and outlines future research directions toward more robust and user-friendly wearable sensing solutions for ergonomic applications.
- Open Access
- 21 October 2025
- Published by Elsevier in Measurement
- Vol. 258
Flexible body-integrated breathing monitoring system based on near-field coupling printed sensor
- 21 October 2025
- Published by Elsevier in Measurement
- Vol. 258
Open AccessFlexible body-integrated breathing monitoring system based on near-field coupling printed sensor
- Open Access
Capacitively Coupled CSRR and H-Slot UHF RFID Antenna for Wireless Glucose Concentration Monitoring
This paper presents a fully passive and wireless glucose concentration sensor that integrates a capacitively coupled complementary split-ring resonator (CSRR) with an H-slot UHF RFID antenna. The CSRR serves as the primary sensing element, where changes in glucose concentration alter the effective permittivity of the surrounding solution, thereby modifying the resonator capacitance and shifting its resonance behavior. Through near-field capacitive coupling, these dielectric variations affect the antenna input impedance and backscatter response, enabling wireless sensing by modulating the maximum read range. The proposed sensor operates within the 902–928 MHz UHF RFID band and is interrogated using commercial RFID readers, eliminating the need for specialized laboratory equipment such as vector network analyzers. Full-wave electromagnetic simulations and experimental measurements validate the sensor performance, demonstrating a variation in the read range from 6.23 m to 4.67 m as glucose concentration increases from 50 to 200 mg/dL. Moreover, the sensor exhibits excellent linearity, with a high coefficient of determination () based on the curve-fitted data. These results underscore the feasibility of the proposed sensor as a low-cost and fully portable platform for concentration monitoring, with potential applications in liquid characterization and chemical sensing.Open AccessCapacitively Coupled CSRR and H-Slot UHF RFID Antenna for Wireless Glucose Concentration Monitoring
This paper presents a fully passive and wireless glucose concentration sensor that integrates a capacitively coupled complementary split-ring resonator (CSRR) with an H-slot UHF RFID antenna. The CSRR serves as the primary sensing element, where changes in glucose concentration alter the effective permittivity of the surrounding solution, thereby modifying the resonator capacitance and shifting its resonance behavior. Through near-field capacitive coupling, these dielectric variations affect the antenna input impedance and backscatter response, enabling wireless sensing by modulating the maximum read range. The proposed sensor operates within the 902–928 MHz UHF RFID band and is interrogated using commercial RFID readers, eliminating the need for specialized laboratory equipment such as vector network analyzers. Full-wave electromagnetic simulations and experimental measurements validate the sensor performance, demonstrating a variation in the read range from 6.23 m to 4.67 m as glucose concentration increases from 50 to 200 mg/dL. Moreover, the sensor exhibits excellent linearity, with a high coefficient of determination () based on the curve-fitted data. These results underscore the feasibility of the proposed sensor as a low-cost and fully portable platform for concentration monitoring, with potential applications in liquid characterization and chemical sensing. - Open Access
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (19) , 37327-37338
A Smart Belt With Embroidered Antenna-Based Sensor for Real-Time Respiratory Monitoring
Wearable technology has increased interest in monitoring vital signs in various medical fields, especially breathing monitoring. However, existing methods to track breathing patterns face challenges, including lack of user comfort, robustness, system reliability, and data processing issues. Therefore, it is crucial to develop user-friendly and reliable wireless methods to overcome these challenges. In this paper, we present a new wireless communication platform for real-time breathing monitoring. The platform consists of a wearable stretching belt with an embroidered loop antenna-based sensor connected to a compact Bluetooth transmitter, with dimensions of 17.145 x 11.303 mm², placed on the abdomen. The proposed antenna-based sensor was designed to transmit data over wireless networks operating at a 2.4GHz frequency. Its sensing mechanism involves detecting a received signal strength indicator (RSSI) wirelessly transmitted by the antenna sensor, which is responsive to strain. Experimental results were conducted to track different breathing patterns from a male volunteer. The system was compared with a Biopac MP36, and the obtained results showed a strong correlation with the measured values. The proposed system demonstrates the ability to detect various breathing patterns, including eupnea, hypopnea, hyperpnea, and Biot’s respiration. Furthermore, its accuracy in detecting these breathing patterns highlights its potential for clinical applications, such as monitoring respiratory health in patients with sleep disorders or chronic respiratory conditions.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (19) , 37327-37338
Open AccessA Smart Belt With Embroidered Antenna-Based Sensor for Real-Time Respiratory Monitoring
Wearable technology has increased interest in monitoring vital signs in various medical fields, especially breathing monitoring. However, existing methods to track breathing patterns face challenges, including lack of user comfort, robustness, system reliability, and data processing issues. Therefore, it is crucial to develop user-friendly and reliable wireless methods to overcome these challenges. In this paper, we present a new wireless communication platform for real-time breathing monitoring. The platform consists of a wearable stretching belt with an embroidered loop antenna-based sensor connected to a compact Bluetooth transmitter, with dimensions of 17.145 x 11.303 mm², placed on the abdomen. The proposed antenna-based sensor was designed to transmit data over wireless networks operating at a 2.4GHz frequency. Its sensing mechanism involves detecting a received signal strength indicator (RSSI) wirelessly transmitted by the antenna sensor, which is responsive to strain. Experimental results were conducted to track different breathing patterns from a male volunteer. The system was compared with a Biopac MP36, and the obtained results showed a strong correlation with the measured values. The proposed system demonstrates the ability to detect various breathing patterns, including eupnea, hypopnea, hyperpnea, and Biot’s respiration. Furthermore, its accuracy in detecting these breathing patterns highlights its potential for clinical applications, such as monitoring respiratory health in patients with sleep disorders or chronic respiratory conditions.
- Open Access
Aging Effects on a Driver Position Sensor Integrated into a Woven Fabric
A textile woven presence sensor was previously presented to demonstrate its functionality in eliminating some false positives on car seat presence sensors. After studying the functionality, the next characteristic that the textile sensor should demonstrate is its reliability. The woven sensor was prepared to be tested against ageing. The ageing cycle was prepared according to the UNE-EN ISO 17228:2015 standard. Nine woven sensors are prepared, seven of them face the aging test, and two are selected as reference sensors. The characterization of the woven sensor has been carried out through a microcontroller measurement circuit that obtains the cycles to charge the sensor. Comparison of the results obtained shows that the effects of ageing are negligible. The behavior of the aged sensors is similar to that of the reference sensors, indicating that the variations in the values of both aged and reference sensors are provoked by the environmental conditions during the measurements. To support this argument, a statistical study based on a t-Student analysis was carried out. After 4 ageing cycles, the functionality of the sensors remains unaffected. This research proves the reliability of the woven textile sensor, which encourages its use in automotive applications.
Open AccessAging Effects on a Driver Position Sensor Integrated into a Woven Fabric
A textile woven presence sensor was previously presented to demonstrate its functionality in eliminating some false positives on car seat presence sensors. After studying the functionality, the next characteristic that the textile sensor should demonstrate is its reliability. The woven sensor was prepared to be tested against ageing. The ageing cycle was prepared according to the UNE-EN ISO 17228:2015 standard. Nine woven sensors are prepared, seven of them face the aging test, and two are selected as reference sensors. The characterization of the woven sensor has been carried out through a microcontroller measurement circuit that obtains the cycles to charge the sensor. Comparison of the results obtained shows that the effects of ageing are negligible. The behavior of the aged sensors is similar to that of the reference sensors, indicating that the variations in the values of both aged and reference sensors are provoked by the environmental conditions during the measurements. To support this argument, a statistical study based on a t-Student analysis was carried out. After 4 ageing cycles, the functionality of the sensors remains unaffected. This research proves the reliability of the woven textile sensor, which encourages its use in automotive applications.
- Open Access
Sensor Technologies for Non-Invasive Blood Glucose Monitoring
Diabetes poses a significant global health challenge, underscoring the urgent need for accurate and continuous glucose monitoring technologies. This review provides a comprehensive analysis of both invasive and non-invasive sensor technologies, with a particular focus on antenna-sensors and their working principle. Key aspects, including the selection of substrates and conductive materials, fabrication techniques, and recent advancements in rigid and flexible antenna-sensor designs, are critically evaluated. Notably, textile antenna-sensors are gaining increasing attention due to their potential for seamless integration into daily clothing. Furthermore, the influence of the human body on antenna-sensor performance is examined, emphasizing the importance of human phantom simulation and fabrication for precise modeling and validation. Finally, this review highlights the current technical challenges in the development of flexible antenna-sensors and discusses their transformative potential in enabling next-generation, non-invasive, and patient-centric glucose monitoring solutions.
Open AccessSensor Technologies for Non-Invasive Blood Glucose Monitoring
Diabetes poses a significant global health challenge, underscoring the urgent need for accurate and continuous glucose monitoring technologies. This review provides a comprehensive analysis of both invasive and non-invasive sensor technologies, with a particular focus on antenna-sensors and their working principle. Key aspects, including the selection of substrates and conductive materials, fabrication techniques, and recent advancements in rigid and flexible antenna-sensor designs, are critically evaluated. Notably, textile antenna-sensors are gaining increasing attention due to their potential for seamless integration into daily clothing. Furthermore, the influence of the human body on antenna-sensor performance is examined, emphasizing the importance of human phantom simulation and fabrication for precise modeling and validation. Finally, this review highlights the current technical challenges in the development of flexible antenna-sensors and discusses their transformative potential in enabling next-generation, non-invasive, and patient-centric glucose monitoring solutions.
- Open Access
- 21 May 2025
- Published by MDPI AG in Electronics
- Vol. 14 (10) , 2084
Study of Wash-Induced Performance Variability in Embroidered Antenna Sensors for Physiological Monitoring
This paper presents a study on the repeatability of washing effects on two antenna-based sensors for breathing monitoring. One sensor is an embroidered meander antenna-based sensor integrated into a T-shirt, and the other is a loop antenna integrated into a belt. Both sensors were subjected to five washing cycles, and their performance was assessed after each wash. The embroidered meander antenna was specifically compared before and after washing to monitor a male volunteer’s different breathing patterns, that is, eupnea, apnea, hypopnea, and hyperpnea. Stretching tests were also conducted to evaluate the impact of mechanical deformation on sensor behavior. The results highlight the changes in sensor performance across multiple washes and stretching conditions, offering insights into the durability and reliability of these embroidered and loop antennas for practical applications in wearable health monitoring. The findings emphasize the importance of considering both washing and mechanical stress in the design of robust antenna-based sensors.
- 21 May 2025
- Published by MDPI AG in Electronics
- Vol. 14 (10) , 2084
Open AccessStudy of Wash-Induced Performance Variability in Embroidered Antenna Sensors for Physiological Monitoring
This paper presents a study on the repeatability of washing effects on two antenna-based sensors for breathing monitoring. One sensor is an embroidered meander antenna-based sensor integrated into a T-shirt, and the other is a loop antenna integrated into a belt. Both sensors were subjected to five washing cycles, and their performance was assessed after each wash. The embroidered meander antenna was specifically compared before and after washing to monitor a male volunteer’s different breathing patterns, that is, eupnea, apnea, hypopnea, and hyperpnea. Stretching tests were also conducted to evaluate the impact of mechanical deformation on sensor behavior. The results highlight the changes in sensor performance across multiple washes and stretching conditions, offering insights into the durability and reliability of these embroidered and loop antennas for practical applications in wearable health monitoring. The findings emphasize the importance of considering both washing and mechanical stress in the design of robust antenna-based sensors.
- Open Access
- 15 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 9, 227-235
Meander Resonator Coupled UHF RFID System for Biomechanics Sensing Applications
This paper presents a biomechanics sensing system based on an ultra-high frequency (UHF) RFID tag coupled with a meander resonator for motion tracking and displacement sensing. The variations in their relative position alter the strength of mutual coupling, leading to impedance changes in the RFID tag antenna. These impedance variations modulate the power reflection coefficient, which in turn affects both the backscattered signal strength (RSSI) and the turn-on threshold power of the RFID tag. The performance of the system was evaluated through simulations and experimental validation, demonstrating a 14 dB reduction in RSSI and a 5 dBm increase in threshold power over a displacement range of 30 mm. The system was further validated for wearable movement sensing in knee flexion tracking, where results indicated an RSSI variation of around 12 dB as the knee angle changed from 115∘ to 175∘. Additionally, the turn-on threshold power ( Pth ) exhibited a strong correlation with knee flexion angles, achieving a coefficient of determination ( R2 = 0.973 ) based on curve-fitted data. These results validate the feasibility of the proposed system for wearable body motion monitoring in healthcare applications.
- 15 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 9, 227-235
Open AccessMeander Resonator Coupled UHF RFID System for Biomechanics Sensing Applications
This paper presents a biomechanics sensing system based on an ultra-high frequency (UHF) RFID tag coupled with a meander resonator for motion tracking and displacement sensing. The variations in their relative position alter the strength of mutual coupling, leading to impedance changes in the RFID tag antenna. These impedance variations modulate the power reflection coefficient, which in turn affects both the backscattered signal strength (RSSI) and the turn-on threshold power of the RFID tag. The performance of the system was evaluated through simulations and experimental validation, demonstrating a 14 dB reduction in RSSI and a 5 dBm increase in threshold power over a displacement range of 30 mm. The system was further validated for wearable movement sensing in knee flexion tracking, where results indicated an RSSI variation of around 12 dB as the knee angle changed from 115∘ to 175∘. Additionally, the turn-on threshold power ( Pth ) exhibited a strong correlation with knee flexion angles, achieving a coefficient of determination ( R2 = 0.973 ) based on curve-fitted data. These results validate the feasibility of the proposed system for wearable body motion monitoring in healthcare applications.
- Open Access
- 1 May 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 391
Breathable artificial magnetic conductor with ground-grid structure for shielding wearable antenna sensors
- 1 May 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 391
Open AccessBreathable artificial magnetic conductor with ground-grid structure for shielding wearable antenna sensors