Boon Seng Ooi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Boon Seng Ooi has a total of 146 co-authors. Here are the top co-authors by number of shared publications:
- Abdul Latif Ahmad
Universiti Sains Malaysia
57 shared publications - JitKang Lim
Universiti Sains Malaysia
11 shared publications - Siew Chun Low
School of Chemical Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang, Malaysia
9 shared publications - Adhi Kusumastuti
Faculty of Engineering Universitas Negeri Semarang, Kampus UNNES Sekaran, Gunungpati, 50229 Semarang, Indonesia
7 shared publications - Eng-Poh Ng
School of Chemical Sciences, Universiti Sains Malaysia, USM, Penang 11800, Malaysia
6 shared publications C.J.C. Derek
5 shared publications
Latest Publications
- 29 July 2025
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 142 (45)
High‐Performance of GO / Cu‐MOFs Embedded PVDF Nanofiltration Membranes for Positively Charged Dyes and Cations Removal and Its Antibacterial Properties
This study aimed to fabricate graphene oxide (GO)‐embedded polyvinylidene fluoride (PVDF) membranes through a non‐solvent induced phase separation method. Different ratios of Cu‐Metal Organic Frameworks (Cu‐MOFs) were used as a nanofillers to promote the membrane's performance on ions and dyes separation. The morphology of fabricated membranes was investigated using FTIR, XRD, and SEM–EDX techniques. The fabricated membranes were tested for water permeability, ions, dyes, and Bovine Serum Albumin (BSA) rejection, and Molecular Weight Cut Off (MWCO). The BSA with initial concentrations of 100–400 mg/L and a molecular weight of 3–145 kDa were filtered via crossflow (CF) and dead‐end (DE) methods. Antibacterial activity against three strains of bacteria was assessed via total plate counting and the Kirby‐Bauer method. The incorporation of hydrophilic GO and (Cu‐MOFs) obviously altered membrane morphology, enhancing the membrane's porosity and hydrophilicity. Moreover, it improves membrane crystallinity (> 85%) as indicated by the higher XRD peak intensity and elasticity (> 300%). The membrane fabricated with a GO/Cu‐MOFs ratio of 1:3 demonstrated the highest permeability and ion rejection toward Na + , Ca 2+ , and Fe 3+ showing rejection rates that were four times higher than those of PVDF membranes with MWCO of ~3 kDa, consistent with the characteristics of loose nanofiltration membranes. The fabricated membranes showed good fouling resistance with a recovery factor ratio (FRR) of > 90% and a lower fouling ratio (Rt, Rr, and Rir) than that of the PVDF membrane. Similar results of membrane performances using dead‐end measurements were also found. The fabricated membranes exhibited superior antibacterial properties with bacterial inhibition zones of 27.5 mm ( Escherichia coli ) and 19.06 mm ( Bacillus subtilis ) strains. These results inferred that PVDF/GO/Cu‐MOFs membranes have great potential as antibiofouling and pre‐desalination membranes.
- 29 July 2025
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 142 (45)
High‐Performance of GO / Cu‐MOFs Embedded PVDF Nanofiltration Membranes for Positively Charged Dyes and Cations Removal and Its Antibacterial Properties
This study aimed to fabricate graphene oxide (GO)‐embedded polyvinylidene fluoride (PVDF) membranes through a non‐solvent induced phase separation method. Different ratios of Cu‐Metal Organic Frameworks (Cu‐MOFs) were used as a nanofillers to promote the membrane's performance on ions and dyes separation. The morphology of fabricated membranes was investigated using FTIR, XRD, and SEM–EDX techniques. The fabricated membranes were tested for water permeability, ions, dyes, and Bovine Serum Albumin (BSA) rejection, and Molecular Weight Cut Off (MWCO). The BSA with initial concentrations of 100–400 mg/L and a molecular weight of 3–145 kDa were filtered via crossflow (CF) and dead‐end (DE) methods. Antibacterial activity against three strains of bacteria was assessed via total plate counting and the Kirby‐Bauer method. The incorporation of hydrophilic GO and (Cu‐MOFs) obviously altered membrane morphology, enhancing the membrane's porosity and hydrophilicity. Moreover, it improves membrane crystallinity (> 85%) as indicated by the higher XRD peak intensity and elasticity (> 300%). The membrane fabricated with a GO/Cu‐MOFs ratio of 1:3 demonstrated the highest permeability and ion rejection toward Na + , Ca 2+ , and Fe 3+ showing rejection rates that were four times higher than those of PVDF membranes with MWCO of ~3 kDa, consistent with the characteristics of loose nanofiltration membranes. The fabricated membranes showed good fouling resistance with a recovery factor ratio (FRR) of > 90% and a lower fouling ratio (Rt, Rr, and Rir) than that of the PVDF membrane. Similar results of membrane performances using dead‐end measurements were also found. The fabricated membranes exhibited superior antibacterial properties with bacterial inhibition zones of 27.5 mm ( Escherichia coli ) and 19.06 mm ( Bacillus subtilis ) strains. These results inferred that PVDF/GO/Cu‐MOFs membranes have great potential as antibiofouling and pre‐desalination membranes.
- Open Access
- 13 January 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 112 (1) , 155-175
Emulsion Liquid Membrane Modelling for Cadmium Removal using Taylor-Couette Column
Emulsion liquid membrane modelling for cadmium extraction using a counter rotating Taylor-Couette column (TCC) has been done. Lower shear stress in a TCC system is beneficial in preventing emulsion damage while maintaining excellent extraction efficiency. The study used type II facilitated transport of cadmium based on the immobilized hollow spherical globule model. The investigated parameters were HCl concentration in the external phase (0.05 - 0.5 M), extraction speed (inner cylinder 600 rpm, outer cylinder: 300 - 700 rpm), initial feed concentration (75 - 300 ppm), volume ratio of internal to membrane phase (1/3 - 1/6), and volume ratio to of emulsion to feed phase (1/4 - 1/10). The model could explain the experimental data very well with an accuracy of more than 95%.
- 13 January 2024
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 112 (1) , 155-175
Open AccessEmulsion Liquid Membrane Modelling for Cadmium Removal using Taylor-Couette Column
Emulsion liquid membrane modelling for cadmium extraction using a counter rotating Taylor-Couette column (TCC) has been done. Lower shear stress in a TCC system is beneficial in preventing emulsion damage while maintaining excellent extraction efficiency. The study used type II facilitated transport of cadmium based on the immobilized hollow spherical globule model. The investigated parameters were HCl concentration in the external phase (0.05 - 0.5 M), extraction speed (inner cylinder 600 rpm, outer cylinder: 300 - 700 rpm), initial feed concentration (75 - 300 ppm), volume ratio of internal to membrane phase (1/3 - 1/6), and volume ratio to of emulsion to feed phase (1/4 - 1/10). The model could explain the experimental data very well with an accuracy of more than 95%.
- 13 October 2023
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 98 (12) , 2992-3003
Evaluation of anti‐wetting nano‐fumed silica/PVDF hollow‐fiber membrane by central composite design optimization towards efficient desalination performance via membrane distillation
BACKGROUND: Membrane distillation (MD) is considered a viable technology to overcome the issue of water scarcity by desalination of seawater. However, the application of MD has been severely restricted by membrane‐wetting phenomena. This study aims to optimize the desired mixed‐matrix hollow‐fiber (HF) membrane conditions that have anti‐wetting characteristics for efficient desalination. Response surface methodology based on central composite design was used to predict and optimize the permeate flux and salt rejection (SR). The combined effects of polymer (polyvinylidene fluoride, PVDF) concentration, nano‐fumed silica (NFS) particle loading, coagulation bath temperature (CBT) and air gap distance (AG), as well as their interactions in terms of desalination performance, have been investigated.RESULTS: The linear factors (NFS, CBT), the quadratic effects of all variables, as well as the interacting terms between (PVDF, NFS), (PVDF, CBT) and (NFS, CBT) had significant effects for both pure water and permeate fluxes. For SR, only PVDF presented a linear effect, while a quadratic effect was obtained in (NFS, AG) and an interaction effect was obtained between PVDF and NFS. Under optimal conditions of PVDF (15.03 wt%), NFS (1.21 wt%), CBT (54.85 °C) and AG (9.9 cm), the optimal mixed‐matrix HF membrane demonstrated higher experimental average values for pure water and permeate fluxes, which reached up to 11.95 and 11.61 kg m−2 h−1 respectively, and an SR of 99.96% as compared to the pristine membrane.CONCLUSION: Our research provides an efficient anti‐wetting NFS/PVDF mixed‐matrix HF membrane, indicating that the optimal membrane possesses high potential for the direct contact membrane distillation (DCMD) process. © 2023 Society of Chemical Industry (SCI).
- 13 October 2023
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 98 (12) , 2992-3003
Evaluation of anti‐wetting nano‐fumed silica/PVDF hollow‐fiber membrane by central composite design optimization towards efficient desalination performance via membrane distillation
BACKGROUND: Membrane distillation (MD) is considered a viable technology to overcome the issue of water scarcity by desalination of seawater. However, the application of MD has been severely restricted by membrane‐wetting phenomena. This study aims to optimize the desired mixed‐matrix hollow‐fiber (HF) membrane conditions that have anti‐wetting characteristics for efficient desalination. Response surface methodology based on central composite design was used to predict and optimize the permeate flux and salt rejection (SR). The combined effects of polymer (polyvinylidene fluoride, PVDF) concentration, nano‐fumed silica (NFS) particle loading, coagulation bath temperature (CBT) and air gap distance (AG), as well as their interactions in terms of desalination performance, have been investigated.RESULTS: The linear factors (NFS, CBT), the quadratic effects of all variables, as well as the interacting terms between (PVDF, NFS), (PVDF, CBT) and (NFS, CBT) had significant effects for both pure water and permeate fluxes. For SR, only PVDF presented a linear effect, while a quadratic effect was obtained in (NFS, AG) and an interaction effect was obtained between PVDF and NFS. Under optimal conditions of PVDF (15.03 wt%), NFS (1.21 wt%), CBT (54.85 °C) and AG (9.9 cm), the optimal mixed‐matrix HF membrane demonstrated higher experimental average values for pure water and permeate fluxes, which reached up to 11.95 and 11.61 kg m−2 h−1 respectively, and an SR of 99.96% as compared to the pristine membrane.CONCLUSION: Our research provides an efficient anti‐wetting NFS/PVDF mixed‐matrix HF membrane, indicating that the optimal membrane possesses high potential for the direct contact membrane distillation (DCMD) process. © 2023 Society of Chemical Industry (SCI).
- 4 December 2022
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 18 (2)
Potential effects of nano‐fumed silica particles (NFS)/PVDF mixed matrix hollow fiber membrane on the performance of direct contact membrane distillation
Hydrophobic nano‐fumed silica (NFS) was incorporated in polyvinylidene fluoride (PVDF) hollow fiber (HF) membrane for improving direct contact membrane distillation (DCMD) performance. The NFS/PVDF mixed matrix hollow fiber membrane was fabricated by the phase inversion process. The potential effects of increasing the percentage of NFS additive (0–6 wt.%) in the dope solution on the hollow fiber membrane characteristics such as viscosity, membrane morphology, porosity, hydrophobicity, Fourier transformed infrared spectroscopy, and permeability were investigated. The performance outcomes showed that the dope solution incorporated with 1.5 wt.% NFS exhibited the most promising HF membrane for membrane distillation (MD). The optimal HF membrane demonstrated the highest flux through shorter and narrower finger‐like structure formation and targeted high porosity. The addition of NFS particle content in the dope solutions enhanced the hydrophobicity of the fabricated membranes while slightly decreasing the porosity due to increasing the viscosity of the dope solution. With a steady flux of 9.25 kg/m2 h compared with the neat membrane at 70°C/20°C of feed/permeate temperatures, 8 h operation, and above 99.9% salt rejection, this PVDF/NFS mixed matrix hollow fiber membrane could be of excellent potential and sustainability in desalination process through DCMD.
- 4 December 2022
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 18 (2)
Potential effects of nano‐fumed silica particles (NFS)/PVDF mixed matrix hollow fiber membrane on the performance of direct contact membrane distillation
Hydrophobic nano‐fumed silica (NFS) was incorporated in polyvinylidene fluoride (PVDF) hollow fiber (HF) membrane for improving direct contact membrane distillation (DCMD) performance. The NFS/PVDF mixed matrix hollow fiber membrane was fabricated by the phase inversion process. The potential effects of increasing the percentage of NFS additive (0–6 wt.%) in the dope solution on the hollow fiber membrane characteristics such as viscosity, membrane morphology, porosity, hydrophobicity, Fourier transformed infrared spectroscopy, and permeability were investigated. The performance outcomes showed that the dope solution incorporated with 1.5 wt.% NFS exhibited the most promising HF membrane for membrane distillation (MD). The optimal HF membrane demonstrated the highest flux through shorter and narrower finger‐like structure formation and targeted high porosity. The addition of NFS particle content in the dope solutions enhanced the hydrophobicity of the fabricated membranes while slightly decreasing the porosity due to increasing the viscosity of the dope solution. With a steady flux of 9.25 kg/m2 h compared with the neat membrane at 70°C/20°C of feed/permeate temperatures, 8 h operation, and above 99.9% salt rejection, this PVDF/NFS mixed matrix hollow fiber membrane could be of excellent potential and sustainability in desalination process through DCMD.
- 21 August 2022
- Published by Elsevier in Chemosphere
- Vol. 307 (Pt 4) , 136104
Simultaneous phosphate recovery and sodium removal from brackish aquaculture effluent via diafiltration-nanofiltration process
- 21 August 2022
- Published by Elsevier in Chemosphere
- Vol. 307 (Pt 4) , 136104
Simultaneous phosphate recovery and sodium removal from brackish aquaculture effluent via diafiltration-nanofiltration process
- Open Access
- 12 April 2022
- Published by IWA Publishing in Water Supply
- Vol. 22 (5) , 5618-5637
Treatment of river water using modular gravity-driven ultrafiltration (GDU) for individual contingency water supply
In this work, hollow fibre ultrafiltration (UF) membrane operating under gravitational force were used to treat Escherichia coli bloomed water as well as contaminated surface water. The biofouling propensity of the UF membrane was investigated. The results showed that after the single filtration using the gravitational-driven UF unit, E. coli cells were accumulated on the membrane surface and gave fair rejection of 86.35–90.22% for initial E. coli cells concentrations of 5,000 and 10,000 MPN/ 100 mL, respectively. On the other hand, the double GDU membrane unit (filtration in series) could enhance E. coli removal up to 97.70–99.03% based on initial E. coli cell of 5,000 and 10,000 MPN/100 mL, respectively. For river water as feed, it was found that the permeate is free of pathogenic cells. No significant E. coli cells were found on the membrane surface of second filtration unit. Although there is ten-fold flux decrement by using a double filtration unit, the module is able to polish the contaminated water to potable water quality. The membrane could be cleaned using the simple backwash and the flux could be recovered up to 94%. In overall, this study has demonstrated the potential of using gravitational-driven UF to remove pathogens from contaminated river water.
- 12 April 2022
- Published by IWA Publishing in Water Supply
- Vol. 22 (5) , 5618-5637
Open AccessTreatment of river water using modular gravity-driven ultrafiltration (GDU) for individual contingency water supply
In this work, hollow fibre ultrafiltration (UF) membrane operating under gravitational force were used to treat Escherichia coli bloomed water as well as contaminated surface water. The biofouling propensity of the UF membrane was investigated. The results showed that after the single filtration using the gravitational-driven UF unit, E. coli cells were accumulated on the membrane surface and gave fair rejection of 86.35–90.22% for initial E. coli cells concentrations of 5,000 and 10,000 MPN/ 100 mL, respectively. On the other hand, the double GDU membrane unit (filtration in series) could enhance E. coli removal up to 97.70–99.03% based on initial E. coli cell of 5,000 and 10,000 MPN/100 mL, respectively. For river water as feed, it was found that the permeate is free of pathogenic cells. No significant E. coli cells were found on the membrane surface of second filtration unit. Although there is ten-fold flux decrement by using a double filtration unit, the module is able to polish the contaminated water to potable water quality. The membrane could be cleaned using the simple backwash and the flux could be recovered up to 94%. In overall, this study has demonstrated the potential of using gravitational-driven UF to remove pathogens from contaminated river water.
- 23 February 2022
- Published by Penerbit UTM Press in Journal of Applied Membrane Science & Technology
- Vol. 26 (1) , 77-93
Concentrating Fish Farm Effluent for its Nutrient Recovery via Nanofiltration
Excessive nutrients in aquaculture effluent have become an alarming environmental issue. However, current treatment methods for recovering nutrients are ineffective since the effluent contains trace amounts of nutrients. Pressure-driven nanofiltration (NF) is a potential solution to the problem of low concentration gradient. In this work, NF was applied to concentrate and recover the nutrients (ammonium (NH4+), phosphate, (PO43-), and nitrate ions (NO3-)) from the synthetic and real fish farm effluents. The experiments were first carried out to study the effect of membrane type, feed concentrations, and operating pressures on membrane performance. It is found that NF 90 membrane was able to retain more nutrient ions but compromise with a lower flux compared to NF 270. This study also revealed that an increase in feed concentration enhanced the concentrating ability for both PO43- and NO3- ions but reduced the concentrating factor of NH4+ ions. Moreover, both NF flux and concentrating factor increased with pressure. NF on actual fish farm effluents were investigated under optimal conditions (NF 90, 5 bar). Surprisingly, prefiltered effluent was found to have lower flux than raw effluent due to the presence of denser cake layer. NF could concentrate more nutrients from prefiltered fish farm effluent with concentrating factor up to 6.17 for PO43- ions and 1.55 for NH4+ions, claiming that NF was a promising approach for concentrating nutrients. These nutrients concentrate has an opportunity to be reapplied as fertilizer as a part of sustainable resource management.
- 23 February 2022
- Published by Penerbit UTM Press in Journal of Applied Membrane Science & Technology
- Vol. 26 (1) , 77-93
Concentrating Fish Farm Effluent for its Nutrient Recovery via Nanofiltration
Excessive nutrients in aquaculture effluent have become an alarming environmental issue. However, current treatment methods for recovering nutrients are ineffective since the effluent contains trace amounts of nutrients. Pressure-driven nanofiltration (NF) is a potential solution to the problem of low concentration gradient. In this work, NF was applied to concentrate and recover the nutrients (ammonium (NH4+), phosphate, (PO43-), and nitrate ions (NO3-)) from the synthetic and real fish farm effluents. The experiments were first carried out to study the effect of membrane type, feed concentrations, and operating pressures on membrane performance. It is found that NF 90 membrane was able to retain more nutrient ions but compromise with a lower flux compared to NF 270. This study also revealed that an increase in feed concentration enhanced the concentrating ability for both PO43- and NO3- ions but reduced the concentrating factor of NH4+ ions. Moreover, both NF flux and concentrating factor increased with pressure. NF on actual fish farm effluents were investigated under optimal conditions (NF 90, 5 bar). Surprisingly, prefiltered effluent was found to have lower flux than raw effluent due to the presence of denser cake layer. NF could concentrate more nutrients from prefiltered fish farm effluent with concentrating factor up to 6.17 for PO43- ions and 1.55 for NH4+ions, claiming that NF was a promising approach for concentrating nutrients. These nutrients concentrate has an opportunity to be reapplied as fertilizer as a part of sustainable resource management.
- Open Access
- 2 February 2022
- Published by Springer Nature in Research Square
A modular Gravity-Driven Ultrafiltration (GDU) membrane system for contaminant removal: Dynamic flux modelling and its fouling study
During flood or drought, water shortage is a critical issue due to the water contamination. Under this situation, gravitational driven ultrafiltration (GDU) membrane system which solely depends on hydrostatic pressure could be employed to provide the clean water for domestic usage. Due to the limitation of site accessibility during flood, a modular and batch type GDU membrane system is required for water filtration. In that case, prediction of the water level within the module which affected the hydrostatic pressure and effective filtration area over the time is important. The prediction of water level enables the design of the intermittent pumping frequencies for the optimum usage of energy. In this work, the removal efficiency of GDU system towards two common contaminants in water surface namely humic acid and calcium carbonate were tested. The highest removal efficiency of the GDU system towards humic acid, and calcium carbonate were recorded as 94.96 % and 99.19 % respectively. It was found that different feed solutions exhibited different fluxes declination profiles due to their distinctive fouling characteristic. A model was developed to predict the ideal dynamic flux of the membrane under the condition of reducing hydrostatic pressure and effective membrane area. Using the dynamic model, the resistance of the membrane and cake layer were determined. It was found that the filtration resistance is dominated by the cake layer resistance. River water test showed that GDU is an effective method for reclaiming the river water in removing the colour and turbidity.
- 2 February 2022
- Published by Springer Nature in Research Square
Open AccessA modular Gravity-Driven Ultrafiltration (GDU) membrane system for contaminant removal: Dynamic flux modelling and its fouling study
During flood or drought, water shortage is a critical issue due to the water contamination. Under this situation, gravitational driven ultrafiltration (GDU) membrane system which solely depends on hydrostatic pressure could be employed to provide the clean water for domestic usage. Due to the limitation of site accessibility during flood, a modular and batch type GDU membrane system is required for water filtration. In that case, prediction of the water level within the module which affected the hydrostatic pressure and effective filtration area over the time is important. The prediction of water level enables the design of the intermittent pumping frequencies for the optimum usage of energy. In this work, the removal efficiency of GDU system towards two common contaminants in water surface namely humic acid and calcium carbonate were tested. The highest removal efficiency of the GDU system towards humic acid, and calcium carbonate were recorded as 94.96 % and 99.19 % respectively. It was found that different feed solutions exhibited different fluxes declination profiles due to their distinctive fouling characteristic. A model was developed to predict the ideal dynamic flux of the membrane under the condition of reducing hydrostatic pressure and effective membrane area. Using the dynamic model, the resistance of the membrane and cake layer were determined. It was found that the filtration resistance is dominated by the cake layer resistance. River water test showed that GDU is an effective method for reclaiming the river water in removing the colour and turbidity.
- Open Access
- 20 January 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (3) , 1152
Solvent-Free Synthesis of MIL-101(Cr) for CO2 Gas Adsorption: The Effect of Metal Precursor and Molar Ratio
MIL-101(Cr), a subclass of metal–organic frameworks (MOFs), is a promising adsorbent for carbon dioxide (CO2) removal due to its large pore volume and high surface area. Solvent-free synthesis of MIL-101(Cr) was employed in this work to offer a green alternative to the current approach of synthesizing MIL-101(Cr) using a hazardous solvent. Characterization techniques including XRD, SEM, and FTIR were employed to confirm the formation of pure MIL-101(Cr) synthesized using a solvent-free method. The thermogravimetric analysis revealed that MIL-101(Cr) shows high thermal stability up to 350 °C. Among the materials synthesized, MIL-101(Cr) at the molar ratio of chromium precursor to terephthalic organic acid of 1:1 possesses the highest surface area and greatest pore volume. Its BET surface area and total pore volume are 1110 m2/g and 0.5 cm3/g, respectively. Correspondingly, its CO2 adsorption capacity at room temperature is the highest (18.8 mmol/g), suggesting it is a superior adsorbent for CO2 removal. The textural properties significantly affect the CO2 adsorption capacity, in which large pore volume and high surface area are favorable for the adsorption mechanism.
- 20 January 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (3) , 1152
Open AccessSolvent-Free Synthesis of MIL-101(Cr) for CO2 Gas Adsorption: The Effect of Metal Precursor and Molar Ratio
MIL-101(Cr), a subclass of metal–organic frameworks (MOFs), is a promising adsorbent for carbon dioxide (CO2) removal due to its large pore volume and high surface area. Solvent-free synthesis of MIL-101(Cr) was employed in this work to offer a green alternative to the current approach of synthesizing MIL-101(Cr) using a hazardous solvent. Characterization techniques including XRD, SEM, and FTIR were employed to confirm the formation of pure MIL-101(Cr) synthesized using a solvent-free method. The thermogravimetric analysis revealed that MIL-101(Cr) shows high thermal stability up to 350 °C. Among the materials synthesized, MIL-101(Cr) at the molar ratio of chromium precursor to terephthalic organic acid of 1:1 possesses the highest surface area and greatest pore volume. Its BET surface area and total pore volume are 1110 m2/g and 0.5 cm3/g, respectively. Correspondingly, its CO2 adsorption capacity at room temperature is the highest (18.8 mmol/g), suggesting it is a superior adsorbent for CO2 removal. The textural properties significantly affect the CO2 adsorption capacity, in which large pore volume and high surface area are favorable for the adsorption mechanism.