CVCrisnicaw Veríssimo

Crisnicaw Veríssimo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Crisnicaw Veríssimo has a total of 118 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Different Ethylene‐Vinyl Acetate ( EVA ) Brands Used for Customized Mouthguards on Athlete Preferences, Wearability, Willingness to Pay, Clinical Performance, and Structural Deformation in Elite Soccer Players: A Randomized Double‐Blind Crossover Clinical Trial

    by Luiz Felipe Rodrigues Siqueira, Ângelo Caetano Rodrigues Mathias Pereira, Bruno Felipe Fernandes, Matheus de França Perazzo, Abidiel Silva Guimarães, Patrícia Corrêa‐Faria, Túlio Eduardo Nogueira, Crisnicaw Veríssimo

    Background/Aim: Custom‐made mouthguards are widely used to prevent sports‐related dentoalveolar injuries, but evidence comparing commercial ethylene‐vinyl acetate materials under real sporting conditions remains limited. This randomized crossover clinical trial evaluated whether three commercial ethylene‐vinyl acetate brands (BioArt, Proform, and Polyshok) influence wearability, athlete preference, willingness to pay, clinical performance, and structural deformation in elite soccer players. Materials and Methods: Fourteen athletes were randomized to six sequences of three customized mouthguards in a double‐blind crossover design. Each mouthguard underwent one week of clinical adjustment followed by four weeks of sports use. Wearability and preference were assessed using a questionnaire, willingness to pay by an auction method, and clinical performance by adaptation, retention, and stability. Structural deformation was evaluated before and after use by three‐dimensional optical scanning and digital superimposition. Inferential comparisons were performed using Friedman and Wilcoxon tests, whereas categorical outcomes were summarized descriptively. Results: Eleven athletes completed all phases. Overall wearability did not differ significantly among brands, although breathing differed among the three materials. Proform was the most preferred brand (72.7%), whereas Polyshok showed the highest median willingness to pay (70 United States dollars). Deformation was greatest at the occlusal/incisal surface in several sectioning regions, but occlusal/incisal deformation did not differ significantly among brands. Most mouthguards remained adequately adapted after use. Descriptively, BioArt showed the highest final retention, whereas Proform showed the lowest final retention and was the only brand with reduced stability over time. Conclusions: The commercial ethylene‐vinyl acetate brand did not significantly influence overall wearability or occlusal/incisal deformation, whereas athlete preference and willingness to pay varied among brands. Customized mouthguards showed measurable structural deformation after sports use while most remained adequately adapted, supporting material selection based on athlete‐centered outcomes together with periodic clinical monitoring.

  • Open Access

    Beyond light: evaluating the characteristics of lower-cost LED Curing Units for resin composite polymerization

    by Laís da Mata Almeida, Stella Sueli Lourenço Braga, Maria Tereza Hordones Ribeiro, Rayssa Ferreira Zanatta, Carlos José Soares, Crisnicaw Verissimo

    Objective: This study aimed to evaluate the irradiance (mW/cm2), emission spectrum (mW/nm), radiant exposure (J/cm²), beam profile, and depth of cure of a resin composite light-cured using different low-cost LED light-curing units (LCUs). Materials & Methods: It was tested the following devices: Dental Wireless; LY-A180; LY-B200. The VALO (polywave) and Elipar DeepCure-L (monowave) were used as control groups. Irradiance, emission spectrum, and radiant exposure were evaluated using the MARC Resin Calibrator. The Knoop microhardness test evaluated the depth of cure and elastic modulus. Depth of cure data was analyzed using the Shapiro-Wilk test, Levene’s test, ANOVA, Tukey HSD (α=0.05), and multiple linear regression analysis. Results: VALO and Elipar DeepCure-L showed a homogeneous radiant exitance. ANOVA showed that LCUs and restoration depth (p<.001) were significant, but the interaction was not. Multiple linear regression showed a significant relation between Elastic modulus, Irradiance, and depth of restoration (p=.350). Conclusions: Depth of cure tests showed that lower-cost LCUs tested showed satisfactory results; however, when all the variables were compared, they showed an inferior performance compared to the LCUs used as control.

  • Open Access

    Two‐Year Outcomes of Regenerative Therapy in an Immature Maxillary Molar With Periapical Abscess: A Case Report

    by Luiz Felipe Rodrigues Siqueira, Thais Caetano de Souza-Guedes, Laura Ferreira Araujo, Paulo Ricardo de Sousa Pereira, Crisnicaw Veríssimo, Patrícia Correia de Siqueira, Juliano Gonçalves Miguel, Orlando Aguirre Guedes, Gustavo Silva Chaves

    Trauma or caries in teeth with incomplete root formation can lead to pulp necrosis. Endodontic treatment in such cases requires specific clinical protocols that differ from conventional approaches due to the anatomical and developmental characteristics of immature teeth. This case report describes the clinical management of a maxillary second molar (tooth #17) with incomplete root development and a periapical abscess, treated through pulp revascularization. A 13‐year‐old male patient presented with spontaneous, throbbing pain in the upper right facial region, accompanied by infraorbital swelling. Intraoral examination revealed extensive loss of tooth structure in tooth #17 and the presence of a palatal abscess. Cold pulp testing was negative, while percussion testing was positive, supporting the diagnosis of periapical abscess. Due to the extensive tooth structure, a crown lengthening procedure was performed. Endodontic access was achieved under rubber dam isolation, and three root canals were identified and carefully emptied. Irrigation was performed with 2.5% sodium hypochlorite 4 mm short from the working length, followed by 3 min of EDTA application. Ultracal was used as intracanal medicament for 30 days. At the second appointment, clot induction was achieved with a #20 file, and the cervical third was sealed with Biodentine, followed by composite resin restoration. After a 2‐year clinical, radiographic, and tomographic follow‐up, the tooth remained asymptomatic, with radiographic evidence of continued root maturation and apical closure, suggesting a favorable outcome of the regenerative protocol.

  • Open Access

    Ultimate Tensile Strength Evaluation of Bi‐Colored Ethylene‐Vinyl Acetate (EVA) Sheets In‐Office Manufactured With Different Heating Protocols

    by Luiz Felipe Rodrigues Siqueira, Ângelo Caetano Rodrigues Mathias Pereira, Bruno Felipe Fernandes, Leon Fernando Marques Jaime, Crisnicaw Veríssimo

    Background/Aim: Bi‐colored mouthguards (MTG) are often sought by both professional and amateur athletes. Bi‐colored MTG can be made in the dental office from premanufactured bi‐colored EVA sheets or custom‐designed in the dental office for greater color variety. This study aimed to evaluate the tensile strength of ethylene‐vinyl acetate (EVA) plates from two commercial brands (BioArt and Polyshok), using different bonding methods and heat sources for producing bicolored MTG. Materials and Methods: EVA plates from BioArt and Polyshok (3 mm thickness) were bonded using six methods combining two bonding materials (metal angle and glass plate) and three heat sources (heat gun, mini‐torch, and Hannau lamp). Bonded plates were sectioned into 30 standardized bar‐shaped samples (70 × 10 × 3 mm) and subjected to tensile testing. Ultimate tensile strength was recorded, and statistical analyses were performed using One‐Way ANOVA and Tukey's test (α = 0.05). Results: Significant differences in ultimate tensile strength (MPa) were observed between bonding methods ( p < 0.001) for each commercial brand. The metal angle and heat gun (MAH) method exhibited the highest tensile strength for both tested EVAs (BioArt: 146.5 ± 30 MPa; Polyshok: 87.8 ± 19.3 MPa). The Hannau lamp produced the lowest values for both tested EVAs (BioArt: 69.8 ± 43.1 MPa; Polyshok: 51.0 ± 14.4 MPa). Conclusions: The bonding method significantly affects the tensile strength of EVA plates, with the MAH method and heat gun demonstrating superior performance. These findings highlight the importance of optimizing bonding techniques to ensure durability and protective performance in bi‐colored MTG.


  • Characterization of experimental resin composites with cholesteryl methacrylate organic matrix – Part 2

    by Julyana Dumas Santos Silva, Letícia Nunes de Almeida, Antônio Silva Machado, Amanda Alves de Oliveira, Luiza Santos Cardoso, Cristhiane Gonçalves, Isaac Yves Lopes de Macêdo, Eric de Souza Gil, Crisnicaw Veríssimo, Karla de Aleluia Batista, et al.

  • Open Access

    O uso do protetor facial individualizado no futebol como auxílio na resolução de fratura nasal: Relato de caso

    by Luiz Felipe Rodrigues Siqueira, Ângelo Caetano Rodrigues Mathias Pereira, Bruno Felipe Fernandes, Carlos Bandeira Júnior, Marya Eduarda Cardoso Valente, Crisnicaw Veríssimo

    Traumas orofaciais são prevalentes em práticas esportivas. Os traumas na região nasal são os mais frequentes no futebol e o processo de reparo ósseo deve ser respeitado, podendo afastar o atleta de suas funções. Nesse sentido, o protetor facial individualizado é aliado na proteção da área lesionada proporcionando retorno precoce. O objetivo desse estudo foi relatar o manejo do caso clínico de um atleta de futebol que sofreu fratura nasal associado a confecção de protetor facial individualizado de Etileno-Vinil Acetato (EVA). Paciente JGBM, sexo masculino, 17 anos, jogador de futebol, relatou um acidente durante o treino. Foi realizado o pronto-atendimento de urgência no local e uma fratura nasal foi confirmada pela equipe médica. Após avaliação médica e conduta, foi indicada a utilização de um protetor facial individualizado. O dispositivo foi confeccionado com placas de EVA com 4mm e reforço realizado nos ossos nasal e frontal. Foram realizados todos os ajustes relacionados ao conforto e visão periférica, e as instruções de uso, armazenamento e limpeza fornecidas. O paciente seguiu em acompanhamento pelo período de 90 dias e realizou os procedimentos cirúrgicos de Septoplastia e Adenoidectomia. O uso do protetor facial individualizado para atleta que sofreu fratura nasal, é um método de proteção eficiente, uma vez que auxilia na recuperação da lesão e reduz o tempo de afastamento dos treinamentos e competições, garantindo que o atleta volte de forma segura, confortável e sem prejuízos a sua performance.

  • Open Access

    Evaluation of polymerization shrinkage stress and cuspal strain in natural and typodont teeth

    by Luiza Santos Cardoso, Amanda Alves de Oliveira, Gabrielly D’pAula Muniz Barbosa, Maria Luisa Prazeres Ribeiro, Tainah Costa Firmiano, Crisnicaw Veríssimo

    To evaluate the polymerization shrinkage stress and cuspal strain (CS) generated in an artificial (typodont) and in a natural tooth using different resin composites. Twenty artificial and 20 extracted natural molars were selected. Each tooth was prepared with a 4x4 mm MOD cavity. The natural and typodont teeth were divided into four experimental groups (n=10), according to the resin composite used: Filtek Z100 (3M Oral Care) and Beautifil II LS (Shofu Dental). The cavities were filled using two horizontal increments and the CS (µS) was measured by the strain gauge method. Samples were sectioned into stick-shaped specimens and the bond strength (BS) (MPa) was evaluated using a microtensile BS test. Shrinkage stress and CS were analyzed using 3D finite element analysis. No difference was found between the type of teeth for the CS as shown by the pooled averages: Natural tooth: 541.2 A; Typodont model: 591.4 A. Filtek Z100 CS values were higher than those obtained for Beautifil II LS, regardless of the type of teeth. No statistical difference was found for the BS data. Adhesive failures were more prevalent (79.9%). High shrinkage stress values were observed for Filtek Z100 resin, regardless of tooth type. The CS of typodont teeth showed a shrinkage stress effect, generated during restoration, equivalent to that of natural teeth.


  • Open Access

    The effect of the die material used in the indirect technique on the fracture resistance of a restored molar

    by Paulo Victor de Moura Costa, Amanda Alves de Oliveira, Vitória Ariella Silveira e Silva, Érica Miranda de Torres, Maria Alves Garcia Santos Silva, Crisnicaw Veríssimo

    The aim of this study was to evaluate the effect of different die materials used in the indirect resin composite restorative technique on the fracture resistance and failure mode of restored molars and compare it with the direct resin composite restorative technique. Two flexible die silicone materials for dental models (Die Silicone - Voco and Scan die - Yller) and a type IV dental stone material (Fujirock EP - GC) were evaluated. Sixty third molars were selected and divided into four groups: indirect resin composite restoration - Die silicone (IRCR-DS); indirect resin composite restoration - Scan die (IRCR-SD); indirect resin composite restoration - Fujirock EP (IRCR-FR), and direct resin composite restoration (DRCR). Class II MOD cavities were prepared with 5 mm of buccolingual width and depth. The specimens were restored and subjected to an axial compression load until fracture, and the data were analyzed by one-way ANOVA and Tukey's HSD test (α=.05). The fracture mode was classified into restorable and unrestorable fractures. Fracture resistance values were influenced by the die material used for the IRCR fabrication and by the restorative technique (p<.001). Fracture resistance mean values and standard deviation were: IRCR-DS: 1835.5 ± 324.0 A; IRCR-SD: 1732.5 ± 384.1 AB; IRCR-FR: 1419.3 ± 318.8 BC; and DRCR: 1100.6 ± 224.9 C. Restorable fracture was more prevalent. IRCR with flexible die casts promoted higher fracture resistance and lower prevalence of unrestorable fractures.

    • 1 September 2022
      • Vol. 17  (3) , 308-322

    Multidisciplinary approach for the closure of multiple diastemata with composite resin

    by Amanda Alves de Oliveira, Giovanna Alexandre Vale, Lais da Mata Almeida, Rebeca Carniello Saltarelo, Crisnicaw Verissimo

    Morphologic anterior tooth alterations and diastemata between the anterior teeth are often considered a major esthetic problem. In most cases, the treatment of these conditions involves a multidisciplinary approach. Orthodontic treatment together with direct composite resin veneers are a viable option to close diastemata and alter tooth shape. The extent and etiology of the diastemata must be considered and properly evaluated for the treatment. The present article is a case report of a patient with multiple diastemata in the maxillary anterior teeth, dental crowding, and peg-shaped lateral incisors corrected with orthodontic treatment and direct composite resin veneers. Digital planning was the tool used to decide the tooth proportions before orthodontic treatment and to guide the diagnostic wax-up. An etch-and-rinse adhesive system was applied after etching. A polychromatic layering technique under rubber dam isolation was used for the composite resin veneer construction. Finishing and polishing procedures were achieved using polishing discs and abrasive materials. Direct composite resin is an alternative that allows predictability, esthetics, and the possibility of adjustments, resulting in patient satisfaction.