Paulo César Freitas Santos-Filho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paulo César Freitas Santos-Filho has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Crisnicaw Veríssimo
Department of Oral Rehabilitation Federal University of Goiás Goiânia Goiás Brazil
3 shared publications - Carlos José Soares
Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, Brazil
2 shared publications Bruno Rodrigues Reis
Universidade Federal de Uberlandia School of Dentistry Department of Operative Dentistry and Dental Materials
1 shared publicationBruno de Castro Ferreira Barreto
Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Minas Gerais, Brazil
1 shared publicationCarlos José Soares
Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Minas Gerais, Brazil
1 shared publicationCrisnicaw Verissimo
Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Minas Gerais, Brazil
1 shared publication
Latest Publications
- 1 November 2014
- Published by Elsevier in Journal of Endodontics
- Vol. 40 (11) , 1874-1878
Influence of Ferrule, Post System, and Length on Stress Distribution of Weakened Root-filled Teeth
- 1 November 2014
- Published by Elsevier in Journal of Endodontics
- Vol. 40 (11) , 1874-1878
Influence of Ferrule, Post System, and Length on Stress Distribution of Weakened Root-filled Teeth
- 1 March 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 111 (3) , 234-246
Effect of the crown, post, and remaining coronal dentin on the biomechanical behavior of endodontically treated maxillary central incisors
- 1 March 2014
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 111 (3) , 234-246
Effect of the crown, post, and remaining coronal dentin on the biomechanical behavior of endodontically treated maxillary central incisors
- Open Access
- 2 August 2013
- Published by Anima Educação in Journal of Research in Dentistry
- Vol. 1 (2) , 154-164
The effect of type post, crown, and ferrule presence on stress distribution of maxillary central incisors with weakened roots: Finite Element Analysis
The aim of this study was to evaluate the biomechanical behavior, by means FEA, of maxillary central incisor with weakened roots restored with different posts, crowns and ferrule presence. A digital image of an intact maxillary central incisor section plane around the alveolar bone was obtained in order to build the model of sound tooth. A sound tooth and eight two-dimensional numerical models were generated from the protocol of image processing. The studied factors were: crown type - metal-ceramic crown (MC) and alumina-reinforced ceramic (CC); post type - glass fiber post (GFP) and cast post and core (CPC); and ferrule - absence of ferrule (AFE) and 2,0 mm ferrule (FE2). A 2N static and oblique load with a 135° inclination to the tooth longitudinal axis was applied at the level of palatal surface of the crown. The displacement was restricted and stress of tensile and compression within the tooth structure was recorded. Cast post and core models concentrated stresses in post dentin interface and glass fiber post models had homogeneous stresses distribution within the root dentin similar to sound tooth. The restorative complex GFP-CC concentrated higher stress in coping than GFP-MC, both models with or without ferrule. The ferrule presence improved the stress distribution regardless of the crown and post types. Therefore, cast post-and-cores concentrate too much stresses within a root dentin and post interface; glass fiber post has more homogeneous stress distribution in dentin than cast post-and-cores; the presence of 2 mm ferrule improves the mechanical behavior.
- 2 August 2013
- Published by Anima Educação in Journal of Research in Dentistry
- Vol. 1 (2) , 154-164
Open AccessThe effect of type post, crown, and ferrule presence on stress distribution of maxillary central incisors with weakened roots: Finite Element Analysis
The aim of this study was to evaluate the biomechanical behavior, by means FEA, of maxillary central incisor with weakened roots restored with different posts, crowns and ferrule presence. A digital image of an intact maxillary central incisor section plane around the alveolar bone was obtained in order to build the model of sound tooth. A sound tooth and eight two-dimensional numerical models were generated from the protocol of image processing. The studied factors were: crown type - metal-ceramic crown (MC) and alumina-reinforced ceramic (CC); post type - glass fiber post (GFP) and cast post and core (CPC); and ferrule - absence of ferrule (AFE) and 2,0 mm ferrule (FE2). A 2N static and oblique load with a 135° inclination to the tooth longitudinal axis was applied at the level of palatal surface of the crown. The displacement was restricted and stress of tensile and compression within the tooth structure was recorded. Cast post and core models concentrated stresses in post dentin interface and glass fiber post models had homogeneous stresses distribution within the root dentin similar to sound tooth. The restorative complex GFP-CC concentrated higher stress in coping than GFP-MC, both models with or without ferrule. The ferrule presence improved the stress distribution regardless of the crown and post types. Therefore, cast post-and-cores concentrate too much stresses within a root dentin and post interface; glass fiber post has more homogeneous stress distribution in dentin than cast post-and-cores; the presence of 2 mm ferrule improves the mechanical behavior.
- Open Access
- 1 July 2013
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 27 (4) , 305-310
Effects of threaded post placement on strain and stress distribution of endodontically treated teeth
The aim of this study was to evaluate the effect of parallel and tapered threaded post placement on the strain and stress distribution of endodontically treated teeth. Fifteen bovine incisors were sectioned 15 mm from their apices, endodontically treated, and divided into three groups (n = 5) according to three different threaded posts: parallel threaded post (Radix-Anker, RA); tapered threaded post (Euro-Post, EP) and tapered threaded post (Reforpost II, RII). A strain-gauge was fixed on the proximal surface perpendicular to the long root axis, 2 mm from the cervical limit. Strain generated during post placement was recorded and compared using one-way ANOVA and Tukey's test (α= .05). A scanning electron microscope was used to examine the longitudinal root sections. Stress was evaluated for each group in a two-dimensional finite element analysis. The models were meshed with tetrahedron elements and loaded with 2 N at an angle of 135° to the lingual face. The equivalent Von Mises stress was calculated. The one-way ANOVA showed significant difference among the groups. The RA group (150.0 ± 12.2 A) produced higher external strain than the RII (80.0 ± 12.2 B) and the EP (70.0 ± 6.1 B) groups. The inner strain was approximately five times greater than the external dentin strain. High stress concentrations in each thread of the posts were observed. Scanning electron micrographs showed cracks that started in the threads of the posts. The threaded post placement induced root strain mainly on the parallel side post. Root strain and stress concentration on the post threads tended to create cracks in the inner root canal dentin.
- 1 July 2013
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 27 (4) , 305-310
Open AccessEffects of threaded post placement on strain and stress distribution of endodontically treated teeth
The aim of this study was to evaluate the effect of parallel and tapered threaded post placement on the strain and stress distribution of endodontically treated teeth. Fifteen bovine incisors were sectioned 15 mm from their apices, endodontically treated, and divided into three groups (n = 5) according to three different threaded posts: parallel threaded post (Radix-Anker, RA); tapered threaded post (Euro-Post, EP) and tapered threaded post (Reforpost II, RII). A strain-gauge was fixed on the proximal surface perpendicular to the long root axis, 2 mm from the cervical limit. Strain generated during post placement was recorded and compared using one-way ANOVA and Tukey's test (α= .05). A scanning electron microscope was used to examine the longitudinal root sections. Stress was evaluated for each group in a two-dimensional finite element analysis. The models were meshed with tetrahedron elements and loaded with 2 N at an angle of 135° to the lingual face. The equivalent Von Mises stress was calculated. The one-way ANOVA showed significant difference among the groups. The RA group (150.0 ± 12.2 A) produced higher external strain than the RII (80.0 ± 12.2 B) and the EP (70.0 ± 6.1 B) groups. The inner strain was approximately five times greater than the external dentin strain. High stress concentrations in each thread of the posts were observed. Scanning electron micrographs showed cracks that started in the threads of the posts. The threaded post placement induced root strain mainly on the parallel side post. Root strain and stress concentration on the post threads tended to create cracks in the inner root canal dentin.