Eddy So
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eddy So has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Dave Angelo
National Research Council of Canada, Ottawa, ON K1A 0R6, Canada
2 shared publications- Bart Simons
Royal SMIT Transformers B.V., Nijmegen, The Netherlands
1 shared publication - Harold Parks
Metrology Research Centre, National Research Council Canada, Ottawa, Canada
1 shared publication Rejean Arseneau
Measurement Science and Standards Portfolio, National Research Council of Canada, Ottawa, Canada
1 shared publicationRob Verhoeven
Royal SMIT Transformers B.V.,6531 JC, Nijmegen, The Netherlands
1 shared publication
Latest Publications
- 18 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (6) , 1680-1687
A High-Precision Current Transformer for Loss Measurements of EHV Shunt Reactors
An overview of the development and performance of a special high-precision multiratio three-stage current transformer and its application for loss measurements of extra high voltage. Three-phase shunt reactors with test voltages up to a phase voltage of 1100 kV at royal SMIT transformers are presented and discussed. It features current ratios of 500 A/1 A, 400 A/1 A, 300 A/1 A, 200 A/1 A, and 100 A/1 A with ratio errors within 3 x 10⁻⁶ in both magnitude and phase with burdens up to 1.0 Ω and at power frequencies of 50-60 Hz.
- 18 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (6) , 1680-1687
A High-Precision Current Transformer for Loss Measurements of EHV Shunt Reactors
An overview of the development and performance of a special high-precision multiratio three-stage current transformer and its application for loss measurements of extra high voltage. Three-phase shunt reactors with test voltages up to a phase voltage of 1100 kV at royal SMIT transformers are presented and discussed. It features current ratios of 500 A/1 A, 400 A/1 A, 300 A/1 A, 200 A/1 A, and 100 A/1 A with ratio errors within 3 x 10⁻⁶ in both magnitude and phase with burdens up to 1.0 Ω and at power frequencies of 50-60 Hz.
- 20 February 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (6) , 1704-1709
An Improved Current-Comparator-Based Power Standard With an Uncertainty of 2.5 $\mu\hbox{W/VA}\ (k = 1)$An improved power standard derived from a current comparator power bridge for calibrating active/reactive power and energy meters under sinusoidal conditions is described. Measurements can be made at any power factor from zero lag through unity to zero lead, at positive or negative power, at 120 V, 5 A, and 50 or 60 Hz. The improved power standard has an estimated uncertainty of not more than 2.5 $\mu\hbox{W/VA}$ at $k = 1$. Special high-accuracy current and voltage range extenders have been incorporated to extend the current and voltage ranges up to 200 A and 1200 V, respectively.- 20 February 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 62 (6) , 1704-1709
An Improved Current-Comparator-Based Power Standard With an Uncertainty of 2.5 $\mu\hbox{W/VA}\ (k = 1)$An improved power standard derived from a current comparator power bridge for calibrating active/reactive power and energy meters under sinusoidal conditions is described. Measurements can be made at any power factor from zero lag through unity to zero lead, at positive or negative power, at 120 V, 5 A, and 50 or 60 Hz. The improved power standard has an estimated uncertainty of not more than 2.5 $\mu\hbox{W/VA}$ at $k = 1$. Special high-accuracy current and voltage range extenders have been incorporated to extend the current and voltage ranges up to 200 A and 1200 V, respectively.