BSBart Simons

Bart Simons

*This is an algorithmically generated author record based on publicly available information.

Bart Simons has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

    by Adedasola A. Ademola, Roland B. Brandis, Andreas F. Schuetzinger, Bart Simons, Luc Dorpmanns, Andrea Pinceti, Katelynn D. Vance, Ibukunoluwa O. Korede, Robert M. Orndorff, Micah J. Till, et al.

    Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. This paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.


  • A High-Precision Current Transformer for Loss Measurements of EHV Shunt Reactors

    by Eddy So, Rob Verhoeven, Bart Simons, Harold V. Parks, Dave Angelo

    An overview of the development and performance of a special high-precision multiratio three-stage current transformer and its application for loss measurements of extra high voltage. Three-phase shunt reactors with test voltages up to a phase voltage of 1100 kV at royal SMIT transformers are presented and discussed. It features current ratios of 500 A/1 A, 400 A/1 A, 300 A/1 A, 200 A/1 A, and 100 A/1 A with ratio errors within 3 x 10⁻⁶ in both magnitude and phase with burdens up to 1.0 Ω and at power frequencies of 50-60 Hz.