Zoltan Bardosi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zoltan Bardosi has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Wolfgang Freysinger
Department of Otorhinolaryngology-Head and Neck Surgery, Medical University of Innsbruck, 6020 Innsbruck, Austria
7 shared publications - Milovan Regodic
Neuroimaging Research Core Facility, Innsbruck Medical University, Innsbruck, Austria
2 shared publications - Andreas Mehrle
Department of Mechatronics, MCI, Maximilianstraße 2, 6020 Innsbruck, Austria
1 shared publication - Christian Franz Freyschlag
Department of Neurosurgery, Medical University of Innsbruck, Innsbruck, Austria
1 shared publication Christian Plattner
Medical University Innsbruck, Innsbruck, Austria
1 shared publication- Daniel Dejaco
Department of Otorhinolaryngology-Head and Neck Surgery, Medical University of Innsbruck, 6020 Innsbruck, Austria
1 shared publication
Latest Publications
- Open Access
- 9 October 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (12) , 2311-2319
Adaptive infrared patterns for microscopic surface reconstructions
Purpose: Multi-zoom microscopic surface reconstructions of operating sites, especially in ENT surgeries, would allow multimodal image fusion for determining the amount of resected tissue, for recognizing critical structures, and novel tools for intraoperative quality assurance. State-of-the-art three-dimensional model creation of the surgical scene is challenged by the surgical environment, illumination, and the homogeneous structures of skin, muscle, bones, etc., that lack invariant features for stereo reconstruction. Methods: An adaptive near-infrared pattern projector illuminates the surgical scene with optimized patterns to yield accurate dense multi-zoom stereoscopic surface reconstructions. The approach does not impact the clinical workflow. The new method is compared to state-of-the-art approaches and is validated by determining its reconstruction errors relative to a high-resolution 3D-reconstruction of CT data. Results: 200 surface reconstructions were generated for 5 zoom levels with 10 reconstructions for each object illumination method (standard operating room light, microscope light, random pattern and adaptive NIR pattern). For the adaptive pattern, the surface reconstruction errors ranged from 0.5 to 0.7 mm, as compared to 1–1.9 mm for the other approaches. The local reconstruction differences are visualized in heat maps. Conclusion: Adaptive near-infrared (NIR) pattern projection in microscopic surgery allows dense and accurate microscopic surface reconstructions for variable zoom levels of small and homogeneous surfaces. This could potentially aid in microscopic interventions at the lateral skull base and potentially open up new possibilities for combining quantitative intraoperative surface reconstructions with preoperative radiologic imagery.
- 9 October 2024
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (12) , 2311-2319
Open AccessAdaptive infrared patterns for microscopic surface reconstructions
Purpose: Multi-zoom microscopic surface reconstructions of operating sites, especially in ENT surgeries, would allow multimodal image fusion for determining the amount of resected tissue, for recognizing critical structures, and novel tools for intraoperative quality assurance. State-of-the-art three-dimensional model creation of the surgical scene is challenged by the surgical environment, illumination, and the homogeneous structures of skin, muscle, bones, etc., that lack invariant features for stereo reconstruction. Methods: An adaptive near-infrared pattern projector illuminates the surgical scene with optimized patterns to yield accurate dense multi-zoom stereoscopic surface reconstructions. The approach does not impact the clinical workflow. The new method is compared to state-of-the-art approaches and is validated by determining its reconstruction errors relative to a high-resolution 3D-reconstruction of CT data. Results: 200 surface reconstructions were generated for 5 zoom levels with 10 reconstructions for each object illumination method (standard operating room light, microscope light, random pattern and adaptive NIR pattern). For the adaptive pattern, the surface reconstruction errors ranged from 0.5 to 0.7 mm, as compared to 1–1.9 mm for the other approaches. The local reconstruction differences are visualized in heat maps. Conclusion: Adaptive near-infrared (NIR) pattern projection in microscopic surgery allows dense and accurate microscopic surface reconstructions for variable zoom levels of small and homogeneous surfaces. This could potentially aid in microscopic interventions at the lateral skull base and potentially open up new possibilities for combining quantitative intraoperative surface reconstructions with preoperative radiologic imagery.
- Open Access
Benchmarking Eliminative Radiomic Feature Selection for Head and Neck Lymph Node Classification
In head and neck squamous cell carcinoma (HNSCC) pathologic cervical lymph nodes (LN) remain important negative predictors. Current criteria for LN-classification in contrast-enhanced computed-tomography scans (contrast-CT) are shape-based; contrast-CT imagery allows extraction of additional quantitative data (“features”). The data-driven technique to extract, process, and analyze features from contrast-CTs is termed “radiomics”. Extracted features from contrast-CTs at various levels are typically redundant and correlated. Current sets of features for LN-classification are too complex for clinical application. Effective eliminative feature selection (EFS) is a crucial preprocessing step to reduce the complexity of sets identified. We aimed at exploring EFS-algorithms for their potential to identify sets of features, which were as small as feasible and yet retained as much accuracy as possible for LN-classification. In this retrospective cohort-study, which adhered to the STROBE guidelines, in total 252 LNs were classified as “non-pathologic” (n = 70), “pathologic” (n = 182) or “pathologic with extracapsular spread” (n = 52) by two experienced head-and-neck radiologists based on established criteria which served as a reference. The combination of sparse discriminant analysis and genetic optimization retained up to 90% of the classification accuracy with only 10% of the original numbers of features. From a clinical perspective, the selected features appeared plausible and potentially capable of correctly classifying LNs. Both the identified EFS-algorithm and the identified features need further exploration to assess their potential to prospectively classify LNs in HNSCC.
Open AccessBenchmarking Eliminative Radiomic Feature Selection for Head and Neck Lymph Node Classification
In head and neck squamous cell carcinoma (HNSCC) pathologic cervical lymph nodes (LN) remain important negative predictors. Current criteria for LN-classification in contrast-enhanced computed-tomography scans (contrast-CT) are shape-based; contrast-CT imagery allows extraction of additional quantitative data (“features”). The data-driven technique to extract, process, and analyze features from contrast-CTs is termed “radiomics”. Extracted features from contrast-CTs at various levels are typically redundant and correlated. Current sets of features for LN-classification are too complex for clinical application. Effective eliminative feature selection (EFS) is a crucial preprocessing step to reduce the complexity of sets identified. We aimed at exploring EFS-algorithms for their potential to identify sets of features, which were as small as feasible and yet retained as much accuracy as possible for LN-classification. In this retrospective cohort-study, which adhered to the STROBE guidelines, in total 252 LNs were classified as “non-pathologic” (n = 70), “pathologic” (n = 182) or “pathologic with extracapsular spread” (n = 52) by two experienced head-and-neck radiologists based on established criteria which served as a reference. The combination of sparse discriminant analysis and genetic optimization retained up to 90% of the classification accuracy with only 10% of the original numbers of features. From a clinical perspective, the selected features appeared plausible and potentially capable of correctly classifying LNs. Both the identified EFS-algorithm and the identified features need further exploration to assess their potential to prospectively classify LNs in HNSCC.
- Open Access
- 28 April 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (02) , 025002-19
Automated fiducial marker detection and localization in volumetric computed tomography images: a three-step hybrid approach with deep learning
Fiducial markers are used for reliable and accurate patient registration in image-guided interventions. Such surgical interventions are performed during the placement of both a cochlear implant into the inner ear1 and electrodes for deep brain stimulation to treat patients with Parkinson’s disease and essential tremor.2 Markers are usually attached to the skin or screwed into the bone, with the latter providing greater accuracy at the cost of invasiveness.3 A recent method exploits spherical markers placed inside the nasal cavity (nasopharynx) and could be automatically localized by their internal magnetic sensors.4 Experiments with phantoms show that the advantageous marker positioning in the head provides a feasibility of submillimetric accuracy for the surgeries of the lateral skull base.4 Following the placement of fiducial markers and recording the patient’s pre-operative images, rigid registration is used to establish medical navigation by computing the optimal transformation between the fiducial points in the image and in the physical location of that patient during surgery. The optimal transformation can be found by minimizing the sum of the squared distances between each corresponding pair as shown by Horn.5 The square root of the mean of this squared distance is often referred to as fiducial registration error (FRE). The FRE, as pointed by Fitzpatrick,6 could indicate whether or not the registration process is functioning correctly, but, if the process is functioning correctly, then this quantity should not be used to determine the accuracy of patient registration. A more reasonable measure of the registration error is at the (surgical) point of interest referred to as target registration error (TRE).6 It has been shown that both the FRE and the TRE are dependent on the error in identifying the correct location of the fiducials, called fiducial localization error (FLE).7,8 The FLE is defined as the distance between the real and measured fiducial point. Thus, reducing FLEs both in the image and physical space can contribute to improving the registration accuracy.
- 28 April 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (02) , 025002-19
Open AccessAutomated fiducial marker detection and localization in volumetric computed tomography images: a three-step hybrid approach with deep learning
Fiducial markers are used for reliable and accurate patient registration in image-guided interventions. Such surgical interventions are performed during the placement of both a cochlear implant into the inner ear1 and electrodes for deep brain stimulation to treat patients with Parkinson’s disease and essential tremor.2 Markers are usually attached to the skin or screwed into the bone, with the latter providing greater accuracy at the cost of invasiveness.3 A recent method exploits spherical markers placed inside the nasal cavity (nasopharynx) and could be automatically localized by their internal magnetic sensors.4 Experiments with phantoms show that the advantageous marker positioning in the head provides a feasibility of submillimetric accuracy for the surgeries of the lateral skull base.4 Following the placement of fiducial markers and recording the patient’s pre-operative images, rigid registration is used to establish medical navigation by computing the optimal transformation between the fiducial points in the image and in the physical location of that patient during surgery. The optimal transformation can be found by minimizing the sum of the squared distances between each corresponding pair as shown by Horn.5 The square root of the mean of this squared distance is often referred to as fiducial registration error (FRE). The FRE, as pointed by Fitzpatrick,6 could indicate whether or not the registration process is functioning correctly, but, if the process is functioning correctly, then this quantity should not be used to determine the accuracy of patient registration. A more reasonable measure of the registration error is at the (surgical) point of interest referred to as target registration error (TRE).6 It has been shown that both the FRE and the TRE are dependent on the error in identifying the correct location of the fiducials, called fiducial localization error (FLE).7,8 The FLE is defined as the distance between the real and measured fiducial point. Thus, reducing FLEs both in the image and physical space can contribute to improving the registration accuracy.
- Open Access
- 8 April 2021
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 16 (9) , 1565-1576
Visual display for surgical targeting: concepts and usability study
Purpose: Interactive image-guided surgery technologies enable accurate target localization while preserving critical nearby structures in many surgical interventions. Current state-of-the-art interfaces largely employ traditional anatomical cross-sectional views or augmented reality environments to present the actual spatial location of the surgical instrument in preoperatively acquired images. This work proposes an alternative, simple, minimalistic visual interface intended to assist during real-time surgical target localization. Methods: The estimated 3D pose of the interventional instruments and their positional uncertainty are intuitively presented in a visual interface with respect to the target point. A usability study with multidisciplinary participants evaluates the proposed interface projected in surgical microscope oculars against cross-sectional views. The latter was presented on a screen both stand-alone and combined with the proposed interface. The instruments were electromagnetically navigated in phantoms. Results: The usability study demonstrated that the participants were able to detect invisible targets marked in phantom imagery with significant enhancements for localization accuracy and duration time. Clinically experienced users reached the targets with shorter trajectories. The stand-alone and multi-modal versions of the proposed interface outperformed cross-sectional views-only navigation in both quantitative and qualitative evaluations. Conclusion: The results and participants’ feedback indicate potential to accurately navigate users toward the target with less distraction and workload. An ongoing study evaluates the proposed system in a preclinical setting for auditory brainstem implantation.
- 8 April 2021
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 16 (9) , 1565-1576
Open AccessVisual display for surgical targeting: concepts and usability study
Purpose: Interactive image-guided surgery technologies enable accurate target localization while preserving critical nearby structures in many surgical interventions. Current state-of-the-art interfaces largely employ traditional anatomical cross-sectional views or augmented reality environments to present the actual spatial location of the surgical instrument in preoperatively acquired images. This work proposes an alternative, simple, minimalistic visual interface intended to assist during real-time surgical target localization. Methods: The estimated 3D pose of the interventional instruments and their positional uncertainty are intuitively presented in a visual interface with respect to the target point. A usability study with multidisciplinary participants evaluates the proposed interface projected in surgical microscope oculars against cross-sectional views. The latter was presented on a screen both stand-alone and combined with the proposed interface. The instruments were electromagnetically navigated in phantoms. Results: The usability study demonstrated that the participants were able to detect invisible targets marked in phantom imagery with significant enhancements for localization accuracy and duration time. Clinically experienced users reached the targets with shorter trajectories. The stand-alone and multi-modal versions of the proposed interface outperformed cross-sectional views-only navigation in both quantitative and qualitative evaluations. Conclusion: The results and participants’ feedback indicate potential to accurately navigate users toward the target with less distraction and workload. An ongoing study evaluates the proposed system in a preclinical setting for auditory brainstem implantation.
- 1 January 2021
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 283, 103533
Nasal cavity airflow: Comparing laser doppler anemometry and computational fluid dynamic simulations
- 1 January 2021
- Published by Elsevier in Respiratory Physiology & Neurobiology
- Vol. 283, 103533
Nasal cavity airflow: Comparing laser doppler anemometry and computational fluid dynamic simulations
- Open Access
- 11 September 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 15 (1) , 49-57
CIGuide: in situ augmented reality laser guidance
Purpose : A robotic intraoperative laser guidance system with hybrid optic-magnetic tracking for skull base surgery is presented. It provides in situ augmented reality guidance for microscopic interventions at the lateral skull base with minimal mental and workload overhead on surgeons working without a monitor and dedicated pointing tools. Methods : Three components were developed: a registration tool (Rhinospider), a hybrid magneto-optic-tracked robotic feedback control scheme and a modified robotic end-effector. Rhinospider optimizes registration of patient and preoperative CT data by excluding user errors in fiducial localization with magnetic tracking. The hybrid controller uses an integrated microscope HD camera for robotic control with a guidance beam shining on a dual plate setup avoiding magnetic field distortions. A robotic needle insertion platform (iSYS Medizintechnik GmbH, Austria) was modified to position a laser beam with high precision in a surgical scene compatible to microscopic surgery. Results : System accuracy was evaluated quantitatively at various target positions on a phantom. The accuracy found is 1.2 mm ± 0.5 mm. Errors are primarily due to magnetic tracking. This application accuracy seems suitable for most surgical procedures in the lateral skull base. The system was evaluated quantitatively during a mastoidectomy of an anatomic head specimen and was judged useful by the surgeon. Conclusion : A hybrid robotic laser guidance system with direct visual feedback is proposed for navigated drilling and intraoperative structure localization. The system provides visual cues directly on/in the patient anatomy, reducing the standard limitations of AR visualizations like depth perception. The custom- built end-effector for the iSYS robot is transparent to using surgical microscopes and compatible with magnetic tracking. The cadaver experiment showed that guidance was accurate and that the end-effector is unobtrusive. This laser guidance has potential to aid the surgeon in finding the optimal mastoidectomy trajectory in more difficult interventions.
- 11 September 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 15 (1) , 49-57
Open AccessCIGuide: in situ augmented reality laser guidance
Purpose : A robotic intraoperative laser guidance system with hybrid optic-magnetic tracking for skull base surgery is presented. It provides in situ augmented reality guidance for microscopic interventions at the lateral skull base with minimal mental and workload overhead on surgeons working without a monitor and dedicated pointing tools. Methods : Three components were developed: a registration tool (Rhinospider), a hybrid magneto-optic-tracked robotic feedback control scheme and a modified robotic end-effector. Rhinospider optimizes registration of patient and preoperative CT data by excluding user errors in fiducial localization with magnetic tracking. The hybrid controller uses an integrated microscope HD camera for robotic control with a guidance beam shining on a dual plate setup avoiding magnetic field distortions. A robotic needle insertion platform (iSYS Medizintechnik GmbH, Austria) was modified to position a laser beam with high precision in a surgical scene compatible to microscopic surgery. Results : System accuracy was evaluated quantitatively at various target positions on a phantom. The accuracy found is 1.2 mm ± 0.5 mm. Errors are primarily due to magnetic tracking. This application accuracy seems suitable for most surgical procedures in the lateral skull base. The system was evaluated quantitatively during a mastoidectomy of an anatomic head specimen and was judged useful by the surgeon. Conclusion : A hybrid robotic laser guidance system with direct visual feedback is proposed for navigated drilling and intraoperative structure localization. The system provides visual cues directly on/in the patient anatomy, reducing the standard limitations of AR visualizations like depth perception. The custom- built end-effector for the iSYS robot is transparent to using surgical microscopes and compatible with magnetic tracking. The cadaver experiment showed that guidance was accurate and that the end-effector is unobtrusive. This laser guidance has potential to aid the surgeon in finding the optimal mastoidectomy trajectory in more difficult interventions.
- Open Access
- 30 March 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (6) , 1043-1049
Estimating ${\hbox {FLE}}_\mathrm{image}$ FLE image distributions of manual fiducial localization in CT imagesThe fiducial localization error distribution (FLE) and fiducial configuration govern the application accuracy of point-based registration and drive target registration error (TRE) prediction models. The error of physically localizing patient fiducials (\({\hbox {FLE}}_\mathrm{patient}\)) is negligible when a registration probe matches the implanted screws with mechanical precision. Reliable trackers provide an unbiased estimate of the positional error (\({\hbox {FLE}}_\mathrm{tracker}\)) with cheap repetitions. FLE further contains the localization error in the imaging data (\({\hbox {FLE}}_\mathrm{image}\)), sampling of which in general is expensive and possibly biased. Finding the best techniques for estimating \({\hbox {FLE}}_\mathrm{image}\) is crucial for the applicability of the TRE prediction methods.- 30 March 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (6) , 1043-1049
Open AccessEstimating ${\hbox {FLE}}_\mathrm{image}$ FLE image distributions of manual fiducial localization in CT imagesThe fiducial localization error distribution (FLE) and fiducial configuration govern the application accuracy of point-based registration and drive target registration error (TRE) prediction models. The error of physically localizing patient fiducials (\({\hbox {FLE}}_\mathrm{patient}\)) is negligible when a registration probe matches the implanted screws with mechanical precision. Reliable trackers provide an unbiased estimate of the positional error (\({\hbox {FLE}}_\mathrm{tracker}\)) with cheap repetitions. FLE further contains the localization error in the imaging data (\({\hbox {FLE}}_\mathrm{image}\)), sampling of which in general is expensive and possibly biased. Finding the best techniques for estimating \({\hbox {FLE}}_\mathrm{image}\) is crucial for the applicability of the TRE prediction methods.