Johannes Schiffer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Johannes Schiffer has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Romeo Ortega
Electrical and Electronic Engineering Department, Instituto Tecnolgico Autnomo de Mxico (ITAM), Mexico City, Mexico
18 shared publications - Nicolai Lorenz-Meyer
Brandenburg University of Technology Cottbus-Senftenberg, 03046, Cottbus, Germany
6 shared publications - Alexey A. Bobtsov
Hangzhou Dianzi University (HDU), Hangzhou, China
5 shared publications - Denis Efimov
Inria, Univ. Lille, CNRS, UMR 9189 - CRIStAL, Lille, France
5 shared publications Jorg Raisch
Technische Universität Berlin, Germany
5 shared publications- Nikolay Nikolaev
Technion — Israel Institute of Technology
5 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Elsevier in SSRN Electronic Journal
Ancillary Service Provision by Heat Pumps Using Load Flexibility and Predictive Control
Heat pumps offer considerable potential for providing frequency-related ancillary services to the electrical grid. However, rapid power modulation can cause condensation in the suction line even when the refrigerant remains superheated, a risk not explicitly addressed by conventional superheat control. We propose a successive linearization-based model predictive control scheme that explicitly considers the suction-line droplet-formation margin during prescribed compressor-power modulation for Frequency Containment Reserve. To achieve this, the vapor compression cycle is represented by a moving-boundary model extended with the dynamics of the suction line, heat source, and heat sink. The compressor speed is derived from the prescribed power and treated as a measured disturbance, while the controller minimizes state and input deviations from the prescribed equilibrium subject to thermodynamic safety constraints. In a numerical case study with Frequency Containment Reserve prequalification activations of 40 %, 60 %, and 80% relative to the equilibrium power, the proposed scheme maintains a positive suction-line droplet-formation marginin all cases, whereas the PI benchmark falls below the condensation limit for up to 30 s. The mean normalized state deviation from the reference equilibrium selected for efficient operation is reduced by 10.1–38.7 %. These numerical results indicate the potentialof predictive control to support ancillary-service power modulation without additional suction-line heating.
- 7 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAncillary Service Provision by Heat Pumps Using Load Flexibility and Predictive Control
Heat pumps offer considerable potential for providing frequency-related ancillary services to the electrical grid. However, rapid power modulation can cause condensation in the suction line even when the refrigerant remains superheated, a risk not explicitly addressed by conventional superheat control. We propose a successive linearization-based model predictive control scheme that explicitly considers the suction-line droplet-formation margin during prescribed compressor-power modulation for Frequency Containment Reserve. To achieve this, the vapor compression cycle is represented by a moving-boundary model extended with the dynamics of the suction line, heat source, and heat sink. The compressor speed is derived from the prescribed power and treated as a measured disturbance, while the controller minimizes state and input deviations from the prescribed equilibrium subject to thermodynamic safety constraints. In a numerical case study with Frequency Containment Reserve prequalification activations of 40 %, 60 %, and 80% relative to the equilibrium power, the proposed scheme maintains a positive suction-line droplet-formation marginin all cases, whereas the PI benchmark falls below the condensation limit for up to 30 s. The mean normalized state deviation from the reference equilibrium selected for efficient operation is reduced by 10.1–38.7 %. These numerical results indicate the potentialof predictive control to support ancillary-service power modulation without additional suction-line heating.
- Open Access
- 3 October 2026
- Published by Elsevier in SSRN Electronic Journal
Ancillary Service Provision by Heat Pumps Using Load Flexibility and Predictive Control
Heat pumps offer considerable potential for providing frequency-related ancillary services to the electrical grid. However, rapid power modulation can cause condensation in the suction line even when the refrigerant remains superheated, a risk not explicitly addressed by conventional superheat control. We propose a successive linearization-based model predictive control scheme that explicitly considers the suction-line droplet-formation margin during prescribed compressor-power modulation for Frequency Containment Reserve. To achieve this, the vapor compression cycle is represented by a moving-boundary model extended with the dynamics of the suction line, heat source, and heat sink. The compressor speed is derived from the prescribed power and treated as a measured disturbance, while the controller minimizes state and input deviations from the prescribed equilibrium subject to thermodynamic safety constraints. In a numerical case study with Frequency Containment Reserve prequalification activations of 40 %, 60 %, and 80 % relative to the equilibrium power, the proposed scheme maintains a positive suction-line droplet-formation marginin all cases, whereas the PI benchmark falls below the condensation limit for up to 30 s. The mean normalized state deviation from the reference equilibrium selected for efficient operation is reduced by 10.1–38.7 %. These numerical results indicate the potential of predictive control to support ancillary-service power modulation without additional suction-line heating.
- 3 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAncillary Service Provision by Heat Pumps Using Load Flexibility and Predictive Control
Heat pumps offer considerable potential for providing frequency-related ancillary services to the electrical grid. However, rapid power modulation can cause condensation in the suction line even when the refrigerant remains superheated, a risk not explicitly addressed by conventional superheat control. We propose a successive linearization-based model predictive control scheme that explicitly considers the suction-line droplet-formation margin during prescribed compressor-power modulation for Frequency Containment Reserve. To achieve this, the vapor compression cycle is represented by a moving-boundary model extended with the dynamics of the suction line, heat source, and heat sink. The compressor speed is derived from the prescribed power and treated as a measured disturbance, while the controller minimizes state and input deviations from the prescribed equilibrium subject to thermodynamic safety constraints. In a numerical case study with Frequency Containment Reserve prequalification activations of 40 %, 60 %, and 80 % relative to the equilibrium power, the proposed scheme maintains a positive suction-line droplet-formation marginin all cases, whereas the PI benchmark falls below the condensation limit for up to 30 s. The mean normalized state deviation from the reference equilibrium selected for efficient operation is reduced by 10.1–38.7 %. These numerical results indicate the potential of predictive control to support ancillary-service power modulation without additional suction-line heating.
- Open Access
- 19 September 2026
- Published by Elsevier in SSRN Electronic Journal
Ancillary Service Provision by Heat Pumps Using Load Flexibility and Predictive Control
Heat pumps offer considerable potential for providing frequency-related ancillary services to the electrical grid. However, linear feedback controllers commonly used in heat pumps do not explicitly resolve the conflict between rapid power tracking and safety constraints such as liquid compressor intake limits. We propose a successive linearization-based model predictive control scheme that enables heat pump participation in Frequency Containment Reserve while respecting operational thermodynamic limits. To achieve this, the vapor compression cycle is represented by a moving-boundary model extended with the dynamics of the suctionline, heat source, and heat sink. By mapping the prescribed compressor power during the Frequency Containment Reserve prequalification test activation to the compressor speed, which acts as a measured disturbance, the successive linearization-based modelpredictive control accounts for thermodynamic safety constraints while minimizing deviations from operating equilibrium. A numerical case study of the Frequency Containment Reserve Prequalification test demonstrates that the proposed scheme, compared to a baseline PI control, avoids safety constraint violation while simultaneously reducing the mean normalized state deviation by up to 38.7 %.
- 19 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAncillary Service Provision by Heat Pumps Using Load Flexibility and Predictive Control
Heat pumps offer considerable potential for providing frequency-related ancillary services to the electrical grid. However, linear feedback controllers commonly used in heat pumps do not explicitly resolve the conflict between rapid power tracking and safety constraints such as liquid compressor intake limits. We propose a successive linearization-based model predictive control scheme that enables heat pump participation in Frequency Containment Reserve while respecting operational thermodynamic limits. To achieve this, the vapor compression cycle is represented by a moving-boundary model extended with the dynamics of the suctionline, heat source, and heat sink. By mapping the prescribed compressor power during the Frequency Containment Reserve prequalification test activation to the compressor speed, which acts as a measured disturbance, the successive linearization-based modelpredictive control accounts for thermodynamic safety constraints while minimizing deviations from operating equilibrium. A numerical case study of the Frequency Containment Reserve Prequalification test demonstrates that the proposed scheme, compared to a baseline PI control, avoids safety constraint violation while simultaneously reducing the mean normalized state deviation by up to 38.7 %.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 10, 469-474
Delay-Robust Primal-Dual Dynamics for Distributed Optimization
Continuous-time primal-dual gradient dynamics (PDGD) is an ubiquitous approach for dynamically solving constrained distributed optimization problems. Yet, the distributed nature of the dynamics makes it prone to communication uncertainties, especially time delays. To mitigate this effect, we propose a delay-robust continuous-time PDGD. The dynamics is obtained by augmenting the standard PDGD with an auxiliary state coupled through a gain matrix, while preserving the optimal solution. Then, we present sufficient tuning conditions for this gain matrix in the form of linear matrix inequalities, which ensure uniform asymptotic stability in the presence of bounded, time-varying delays. The criterion is derived via the Lyapunov-Krasovskii method. A numerical example illustrates the improved delay robustness of our approach compared to the standard PDGD under large, time-varying delays.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 10, 469-474
Delay-Robust Primal-Dual Dynamics for Distributed Optimization
Continuous-time primal-dual gradient dynamics (PDGD) is an ubiquitous approach for dynamically solving constrained distributed optimization problems. Yet, the distributed nature of the dynamics makes it prone to communication uncertainties, especially time delays. To mitigate this effect, we propose a delay-robust continuous-time PDGD. The dynamics is obtained by augmenting the standard PDGD with an auxiliary state coupled through a gain matrix, while preserving the optimal solution. Then, we present sufficient tuning conditions for this gain matrix in the form of linear matrix inequalities, which ensure uniform asymptotic stability in the presence of bounded, time-varying delays. The criterion is derived via the Lyapunov-Krasovskii method. A numerical example illustrates the improved delay robustness of our approach compared to the standard PDGD under large, time-varying delays.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. PP (00189286) , 1-8
State Observer for the Fourth-Order Model of a Salient Pole Synchronous Generator With Stator Losses and Partial Input Measurements
In this paper we study the question of how to reconstruct the state of a power system using Phasor Measurement Units. In our previous research we proved that this question has an affirmative answer imposing some rather strict structural assumptions: namely, neglecting the generator rotors saliency and assuming that the stator resistance of the synchronous generator is zero. It was shown in simulations that the performance of the proposed observer was sensitive to these assumptions, observing a transient quality degradation for realistic simulations not imposing these assumptions. Moreover, it was assumed in our previous work that the mechanical power and the field voltage are available for measurement, a scenario that is not always feasible. In this paper we accomplish two ambitious objectives with our new observer. First, we dot not impose the simplifying assumptions on the generator model. Secondly, we consider the more realistic scenario where only mechanical power is available for measurement. That is, we solve a problem of state reconstruction of a nonlinear system with partially known input measurements—that is well-known to be a very challenging task. Realistic simulation results illustrates the good performance of the proposed observer.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. PP (00189286) , 1-8
State Observer for the Fourth-Order Model of a Salient Pole Synchronous Generator With Stator Losses and Partial Input Measurements
In this paper we study the question of how to reconstruct the state of a power system using Phasor Measurement Units. In our previous research we proved that this question has an affirmative answer imposing some rather strict structural assumptions: namely, neglecting the generator rotors saliency and assuming that the stator resistance of the synchronous generator is zero. It was shown in simulations that the performance of the proposed observer was sensitive to these assumptions, observing a transient quality degradation for realistic simulations not imposing these assumptions. Moreover, it was assumed in our previous work that the mechanical power and the field voltage are available for measurement, a scenario that is not always feasible. In this paper we accomplish two ambitious objectives with our new observer. First, we dot not impose the simplifying assumptions on the generator model. Secondly, we consider the more realistic scenario where only mechanical power is available for measurement. That is, we solve a problem of state reconstruction of a nonlinear system with partially known input measurements—that is well-known to be a very challenging task. Realistic simulation results illustrates the good performance of the proposed observer.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 34 (5) , 1-14
Distributed Adaptive Control for DC Power Distribution Systems Inspired by a Series-Hybrid-Electric Propulsion Architecture
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 34 (5) , 1-14
Open AccessDistributed Adaptive Control for DC Power Distribution Systems Inspired by a Series-Hybrid-Electric Propulsion Architecture
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 34 (1) , 369-380
Interturn Fault Detection in PMSMs: Two Adaptive Observer-Based Noise Insensitive Solutions
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 34 (1) , 369-380
Interturn Fault Detection in PMSMs: Two Adaptive Observer-Based Noise Insensitive Solutions
- Open Access
An Input-Output Data-Driven Dissipativity Approach for Compositional Stability Certification of Interconnected LTI MIMO Systems
We propose an input-output data-driven framework for certifying the stability of interconnected multiple-input-multiple-output linear time-invariant discrete-time systems via QSR-dissipativity. That is, by using measured input-output trajectories of each subsystem, we verify dissipative properties and extract local passivity indices without requiring an explicit model identification. These passivity indices are then used to derive conditions under which the equilibrium of the interconnected system is stable. In particular, the framework identifies how the lack of passivity in some subsystems can be compensated by surpluses in others. The proposed approach enables a compositional stability analysis by combining subsystem-level conditions into a criterion valid for the overall interconnected system. We illustrate via a numerical case study, how to compute channel-wise passivity indices and infer stability guarantees directly from data with the proposed method.
Open AccessAn Input-Output Data-Driven Dissipativity Approach for Compositional Stability Certification of Interconnected LTI MIMO Systems
We propose an input-output data-driven framework for certifying the stability of interconnected multiple-input-multiple-output linear time-invariant discrete-time systems via QSR-dissipativity. That is, by using measured input-output trajectories of each subsystem, we verify dissipative properties and extract local passivity indices without requiring an explicit model identification. These passivity indices are then used to derive conditions under which the equilibrium of the interconnected system is stable. In particular, the framework identifies how the lack of passivity in some subsystems can be compensated by surpluses in others. The proposed approach enables a compositional stability analysis by combining subsystem-level conditions into a criterion valid for the overall interconnected system. We illustrate via a numerical case study, how to compute channel-wise passivity indices and infer stability guarantees directly from data with the proposed method.
- Open Access
A Port-Hamiltonian Modeling Approach for Integrated Hydrogen Systems
Hydrogen's growing role in the transition towards climate-neutral energy systems necessitates structured modeling frameworks. Existing gas network models, largely developed for natural gas, fail to capture hydrogen systems distinct properties, particularly the coupling of hydrogen pipes with electrolyzers, fuel cells, and electrically driven compressors. In this work, we present a unified systematic port-Hamiltonian (pH) framework for modeling hydrogen systems, which inherently provides a passive input-output map of the overall interconnected system and, thus, a promising foundation for structured analysis, control and optimization of this type of newly emerging energy systems.
Open AccessA Port-Hamiltonian Modeling Approach for Integrated Hydrogen Systems
Hydrogen's growing role in the transition towards climate-neutral energy systems necessitates structured modeling frameworks. Existing gas network models, largely developed for natural gas, fail to capture hydrogen systems distinct properties, particularly the coupling of hydrogen pipes with electrolyzers, fuel cells, and electrically driven compressors. In this work, we present a unified systematic port-Hamiltonian (pH) framework for modeling hydrogen systems, which inherently provides a passive input-output map of the overall interconnected system and, thus, a promising foundation for structured analysis, control and optimization of this type of newly emerging energy systems.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 71 (2) , 793-807
A Robust Consensus + Innovations-Based Distributed Parameter Estimator
While distributed parameter estimation has been extensively studied in the literature, little has been achieved in terms of robust analysis and tuning methods in the presence of disturbances. However, disturbances, such as measurement noise and model mismatches occur in any real-world setting. Therefore, providing tuning methods with specific robustness guarantees would greatly benefit the practical application. To address these issues, we recast the error dynamics of a continuous-time version of the widely used consensus + innovations-based distributed parameter estimator to reflect the error dynamics induced by the classical gradient descent algorithm. This paves the way for the construction of a strong Lyapunov function. Based on this result, we derive linear matrix inequality-based tools for tuning the algorithm gains such that a guaranteed upper bound on the $\mathbf {\mathcal {L}_{2}}$-gain with respect to parameter variations, measurement noise, and disturbances in the communication channels is achieved. An application example illustrates the efficiency of the method.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automatic Control
- Vol. 71 (2) , 793-807
A Robust Consensus + Innovations-Based Distributed Parameter Estimator
While distributed parameter estimation has been extensively studied in the literature, little has been achieved in terms of robust analysis and tuning methods in the presence of disturbances. However, disturbances, such as measurement noise and model mismatches occur in any real-world setting. Therefore, providing tuning methods with specific robustness guarantees would greatly benefit the practical application. To address these issues, we recast the error dynamics of a continuous-time version of the widely used consensus + innovations-based distributed parameter estimator to reflect the error dynamics induced by the classical gradient descent algorithm. This paves the way for the construction of a strong Lyapunov function. Based on this result, we derive linear matrix inequality-based tools for tuning the algorithm gains such that a guaranteed upper bound on the $\mathbf {\mathcal {L}_{2}}$-gain with respect to parameter variations, measurement noise, and disturbances in the communication channels is achieved. An application example illustrates the efficiency of the method.