JNJoseph Christopher Norton

Joseph Christopher Norton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joseph Christopher Norton has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Magnetic Flexible Endoscope: Phase 1 First-in-Human Clinical Trial

    by Keith L. Obstein, Claire A. Landewee, James Martin, Simone Caló, Joseph Norton, Jun Wai Kow, Bruno Scaglioni, Pietro Valdastri

    INTRODUCTION: Magnetic actuation of endoscopes is promising—as the endoscope can be pulled from its front. Our team developed a novel magnetic flexible endoscope (MFE) that uses magnetic field sensing, robotic control, and real-time image processing for colonoscopy. We conducted a Phase 1 first-in-human clinical trial to assess platform safety and tolerability. METHODS: Platform: The MFE contains an internal permanent magnet, camera, illumination module, and channels for instruments, insufflation/camera cleaning, irrigation, and suction. A robotic arm maneuvers a second permanent magnet coupled to the MFE. System software facilitates controlled intelligent magnetic actuation. Experiment: 5 patients scheduled for screening colonoscopy ( ICD-10 z12.11) were enrolled. Patients underwent standard of care colonoscopy with monitored anesthesia care. On withdrawal of the colonoscope, sedation was stopped, and after colonoscope removal, the MFE was inserted into the colon through the anus. The MFE was advanced through the colon while the patient was unsedated. After colon traversal, the MFE was withdrawn. Outcomes of interest included safety and tolerability of the MFE, participant sentiment through structured interview, platform usability, and robot pose data. RESULTS: All patients underwent successful standard of care colonoscopy. All patients were awake and alert for MFE colonoscopy, tolerating the examination well without discomfort, pain, or other complaint. There were no adverse events or trauma. The system was robust without software or function failure. DISCUSSION: The MFE successfully traversed the human colon without adverse event or patient discomfort. System performance was successful without unanticipated events. This is the first-time safety and tolerability of the novel platform has been demonstrated in vivo .


  • Open Access

    The adult large bowel: describing environment morphology for effective biomedical device development

    by Joseph C Norton, James W Martin, Conchubhair Winters, Bruno Scaglioni, Keith L Obstein, Venkataraman Subramanian, Pietro Valdastri

    An understanding of the biological environment, and in particular the physical morphology, is crucial for those developing medical devices and software applications. It not only informs appropriate design inputs, but provides the opportunity to evaluate outputs via virtual or synthetic models before investing in costly clinical investigations. The large bowel is a pertinent example, having a major demand for effective technological solutions to clinical unmet needs. Despite numerous efforts in this area, there remains a paucity of accurate and reliable data in literature. This work reviews what is available, including both processed datasets and raw medical images, before providing a comprehensive quantitative description of the environment for biomedical engineers in this and related regions of the body. Computed tomography images from 75 patients, and a blend of different mathematical and computational methods, are used to calculate and define several crucial metrics, including: a typical adult size (abdominal girth) and abdominal shape, location (or depth) of the bowel inside the abdomen, large bowel length, lumen diameter, flexure number and characteristics, volume and anatomical tortuosity. These metrics are reviewed and defined by both gender and body posture, as well as—wherever possible—being spilt into the various anatomical regions of the large bowel. The resulting data can be used to describe a realistic ‘average’ adult large bowel environment and so drive both design specifications and high fidelity test environments.


  • Robotic Autonomy for Magnetic Endoscope Biopsy

    by James W. Martin, Lavinia Barducci, Bruno Scaglioni, Joseph C. Norton, Conchubhair Winters, Venkataraman Subramanian, Alberto Arezzo, Keith L. Obstein, Pietro Valdastri

    Magnetically actuated endoscopes are currently transitioning in to clinical use for procedures such as colonoscopy, presenting numerous benefits over their conventional counterparts. Intelligent and easy-to-use control strategies are an essential part of their clinical effectiveness due to the un-intuitive nature of magnetic field interaction. However, work on developing intelligent control for these devices has mainly been focused on general purpose endoscope navigation. In this work, we investigate the use of autonomous robotic control for magnetic colonoscope intervention via biopsy, another major component of clinical viability. We have developed control strategies with varying levels of robotic autonomy, including semi-autonomous routines for identifying and performing targeted biopsy, as well as random quadrant biopsy. We present and compare the performance of these approaches to magnetic endoscope biopsy against the use of a standard flexible endoscope on bench-top using a colonoscopy training simulator and silicone colon model. The semi-autonomous routines for targeted and random quadrant biopsy were shown to reduce user workload with comparable times to using a standard flexible endoscope.


  • Fundamentals of the gut for capsule engineers

    by Lavinia Barducci, Joseph C Norton, Sunandita Sarker, Sayeed Mohammed, Ryan Jones, Pietro Valdastri, Benjamin S Terry

    The gastrointestinal (GI) tract is a complex environment comprised of the mouth, esophagus, stomach, small and large intestines, rectum and anus, which all cooperate to form the complete working GI system. Access to the GI using endoscopy has been augmented over the past several decades by swallowable diagnostic electromechanical devices, such as pill cameras. Research continues today and into the foreseeable future on new and more capable miniature devices for the purposes of systemic drug delivery, therapy, tissue biopsy, microbiome sampling, and a host of other novel ground-breaking applications. The purpose of this review is to provide engineers in this field a comprehensive reference manual of the GI environment and its complex physical, biological, and chemical characteristics so they can more quickly understand the constraints and challenges associated with developing devices for the GI space. To accomplish this, the work reviews and summarizes a broad spectrum of literature covering the main anatomical and physiological properties of the GI tract that are pertinent to successful development and operation of an electromechanical device. Each organ in the GI is discussed in this context, including the main mechanisms of digestion, chemical and mechanical processes that could impact devices, and GI motor behavior and resultant forces that may be experienced by objects as they move through the environment of the gut.


  • Macro-Scale Tread Patterns for Traction in the Intestine

    by Joseph Christopher Norton, Jordan H. Boyle, Ali Alazmani, Pete R. Culmer, Anne Neville

    Goal: Tread patterns are widely used to increase traction on different substrates, with the tread scale, geometry and material being tailored to the application. This work explores the efficacy of using macro-scale tread patterns for a medical application involving a colon substrate — renowned for its low friction characteristics. Methods: Current literature was first summarized before an experimental approach was used, based on a custom test rig with ex vivo porcine colon, to assess different macro-scale tread patterns. Performance was based on increasing traction while avoiding significant trauma. Repeated testing (n=16) was used to obtain robust results. Results: A macro-scale tread pattern can increase the traction coefficient significantly, with a static traction coefficient of 0.74 ± 0.22 and a dynamic traction coefficient of 0.35 ± 0.04 compared to a smooth (on the macro-scale) Control (0.132 ± 0.055 and 0.054 ± 0.015, respectively). Decreasing the scale and spacing between the tread features reduced apparent trauma but also reduced the traction coefficient. Conclusion: Significant traction can be achieved on colon tissue using a macro-scale tread but a compromise between traction (large feature sizes) and trauma (small feature sizes) may have to be made. Significance: This work provides greater insight into the complex frictional mechanisms of the intestine and gives suggestions for developing functional tread surfaces for a wide range of clinical applications.


  • Adaptive Dynamic Control for Magnetically Actuated Medical Robots

    by Lavinia Barducci, Giovanni Pittiglio, Joseph C. Norton, Keith L. Obstein, Pietro Valdastri

    In the present letter, we discuss a novel dynamic control approach for magnetically actuated robots, by proposing an adaptive control technique, robust toward parametric uncertainties and unknown bounded disturbances. The former generally arise due to partial knowledge of the robots' dynamic parameters, such as inertial factors, the latter are the outcome of unpredictable interaction with unstructured environments. In order to show the application of the proposed approach, we consider controlling the magnetic flexible endoscope (MFE), which is composed of a soft-tethered internal permanent magnet (IPM), actuated with a single external permanent magnet. We provide with experimental analysis to show the possibility of levitating the MFE-one of the most difficult tasks with this platform-in case of partial knowledge of the IPM's dynamics and no knowledge of the tether's behavior. Experiments in an acrylic tube show a reduction of contact of the 32% compared to non-levitating techniques and 1.75 times faster task completion with respect to previously proposed levitating techniques. More realistic experiments, performed in a colon phantom, show that levitating the capsule achieves faster and smoother exploration and that the minimum time for completing the task is attained by the proposed approach.


  • Intelligent magnetic manipulation for gastrointestinal ultrasound

    by Joseph C. Norton, Piotr R. Slawinski, Holly S. Lay, James W. Martin, Benjamin F. Cox, Gerard Cummins, Marc P.Y. Desmulliez, Richard E. Clutton, Keith L. Obstein, Sandy Cochran, et al.

    A capsule robot uses magnetic control and microultrasound feedback for in situ autonomous positioning and diagnostics of microanatomy.


  • Magnetic Levitation for Soft-Tethered Capsule Colonoscopy Actuated With a Single Permanent Magnet: A Dynamic Control Approach

    by Giovanni Pittiglio, Lavinia Barducci, James W. Martin, Joseph C. Norton, Carlo A. Avizzano, Keith L. Obstein, Pietro Valdastri

    The present letter investigates a novel control approach for magnetically driven soft-tethered capsules for colonoscopy-a potentially painless approach for colon inspection. The focus of this work is on a class of devices composed of a magnetic capsule endoscope actuated by a single external permanent magnet. Actuation is achieved by manipulating the external magnet with a serial manipulator, which in turn produces forces and torques on the internal magnetic capsule. We propose a control strategy which, counteracting gravity, achieves levitation of the capsule. This technique, based on a nonlinear backstepping approach, is able to limit contact with the colon walls, reducing friction, avoiding contact with internal folds, and facilitating the inspection of nonplanar cavities. The approach is validated on an experimental setup, which embodies a general scenario faced in colonoscopy. The experiments show that we can attain 19.5% of contact with the colon wall, compared to the almost 100% of previously proposed approaches. Moreover, we show that the control can be used to navigate the capsule through a more realistic environment-a colon phantom-with reasonable completion time.


  • Explicit Model Predictive Control of a Magnetic Flexible Endoscope

    by Bruno Scaglioni, Luca Previtera, James Martin, Joseph Norton, Keith L. Obstein, Pietro Valdastri

    In this letter, explicit model predictive control is applied in conjunction with nonlinear optimization to a magnetically actuated flexible endoscope for the first time. The approach is aimed at computing the motion of the external permanent magnet, given the desired forces and torques. The strategy described here takes advantage of the nonlinear nature of the magnetic actuation and explicitly considers the workspace boundaries, as well as the actuation constraints. Initially, a simplified dynamic model of the tethered capsule, based on the Euler-Lagrange equations is developed. Subsequently, the explicit model predictive control is described and a novel approach for the external magnet positioning, based on a single step, nonlinear optimisation routine, is proposed. Finally, the strategy is implemented on the experimental platform, where bench-top trials are performed on a realistic colon phantom, showing the effectiveness of the technique. The work presented here constitutes an initial exploration for model-based control techniques applied to magnetically manipulated payloads; the techniques described here may be applied to a wide range of devices, including flexible endoscopes and wireless capsules. To our knowledge, this is the first example of advanced closed-loop control of magnetic capsules.