JMJames W. Martin

James W. Martin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


James W. Martin has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Magnetic Flexible Endoscope: Phase 1 First-in-Human Clinical Trial

    by Keith L. Obstein, Claire A. Landewee, James Martin, Simone Caló, Joseph Norton, Jun Wai Kow, Bruno Scaglioni, Pietro Valdastri

    INTRODUCTION: Magnetic actuation of endoscopes is promising—as the endoscope can be pulled from its front. Our team developed a novel magnetic flexible endoscope (MFE) that uses magnetic field sensing, robotic control, and real-time image processing for colonoscopy. We conducted a Phase 1 first-in-human clinical trial to assess platform safety and tolerability. METHODS: Platform: The MFE contains an internal permanent magnet, camera, illumination module, and channels for instruments, insufflation/camera cleaning, irrigation, and suction. A robotic arm maneuvers a second permanent magnet coupled to the MFE. System software facilitates controlled intelligent magnetic actuation. Experiment: 5 patients scheduled for screening colonoscopy ( ICD-10 z12.11) were enrolled. Patients underwent standard of care colonoscopy with monitored anesthesia care. On withdrawal of the colonoscope, sedation was stopped, and after colonoscope removal, the MFE was inserted into the colon through the anus. The MFE was advanced through the colon while the patient was unsedated. After colon traversal, the MFE was withdrawn. Outcomes of interest included safety and tolerability of the MFE, participant sentiment through structured interview, platform usability, and robot pose data. RESULTS: All patients underwent successful standard of care colonoscopy. All patients were awake and alert for MFE colonoscopy, tolerating the examination well without discomfort, pain, or other complaint. There were no adverse events or trauma. The system was robust without software or function failure. DISCUSSION: The MFE successfully traversed the human colon without adverse event or patient discomfort. System performance was successful without unanticipated events. This is the first-time safety and tolerability of the novel platform has been demonstrated in vivo .


  • Top Cited Papers

    Harnessing the oloid shape in magnetically driven robots to enable high-resolution ultrasound imaging

    by Nikita J. Greenidge, Benjamin Calmé, Alexandru C. Moldovan, Bartas Abaravicius, James W. Martin, Nils Marahrens, Jon Woolfrey, Bruno Scaglioni, Damith S. Chathuranga, Srinjoy Mitra, et al.

    Magnetic fields enable remote manipulation of objects and are ideal for medical applications because they pass through human tissue harmlessly. This capability is promising for surgical robots, allowing navigation deeper into the human anatomy and accessing organs beyond the reach of current technologies. However, magnetic manipulation is typically limited to a maximum two–degrees-of-freedom orientation, restricting complex motions, especially those including rolling around the main axis of the magnetic robot. To address this challenge, we introduce a robot design inspired by embodied intelligence and the unique geometry of developable rollers, leveraging the oloid shape. The oloid, with its axial asymmetry and sinusoidal motion, facilitates rolling when precisely controlled by an external magnetic field. We present a versatile closed-loop control model to ensure precise magnetic manipulation of an oloid-shaped robot. This capability was validated in endoluminal applications through the integration of a 28-megahertz micro-ultrasound array to perform virtual biopsies, noninvasive real-time histological imaging. Extensive in vitro and in vivo tests using a porcine model showed the robot’s ability to execute sweeping motions, identify lesions, and generate detailed three-dimensional scans of gastrointestinal subsurface tissue. This research not only restores a critical movement capability to magnetic medical robots but also enables additional clinical applications deep within the human body.


  • Open Access

    The adult large bowel: describing environment morphology for effective biomedical device development

    by Joseph C Norton, James W Martin, Conchubhair Winters, Bruno Scaglioni, Keith L Obstein, Venkataraman Subramanian, Pietro Valdastri

    An understanding of the biological environment, and in particular the physical morphology, is crucial for those developing medical devices and software applications. It not only informs appropriate design inputs, but provides the opportunity to evaluate outputs via virtual or synthetic models before investing in costly clinical investigations. The large bowel is a pertinent example, having a major demand for effective technological solutions to clinical unmet needs. Despite numerous efforts in this area, there remains a paucity of accurate and reliable data in literature. This work reviews what is available, including both processed datasets and raw medical images, before providing a comprehensive quantitative description of the environment for biomedical engineers in this and related regions of the body. Computed tomography images from 75 patients, and a blend of different mathematical and computational methods, are used to calculate and define several crucial metrics, including: a typical adult size (abdominal girth) and abdominal shape, location (or depth) of the bowel inside the abdomen, large bowel length, lumen diameter, flexure number and characteristics, volume and anatomical tortuosity. These metrics are reviewed and defined by both gender and body posture, as well as—wherever possible—being spilt into the various anatomical regions of the large bowel. The resulting data can be used to describe a realistic ‘average’ adult large bowel environment and so drive both design specifications and high fidelity test environments.


  • Robotic Autonomy for Magnetic Endoscope Biopsy

    by James W. Martin, Lavinia Barducci, Bruno Scaglioni, Joseph C. Norton, Conchubhair Winters, Venkataraman Subramanian, Alberto Arezzo, Keith L. Obstein, Pietro Valdastri

    Magnetically actuated endoscopes are currently transitioning in to clinical use for procedures such as colonoscopy, presenting numerous benefits over their conventional counterparts. Intelligent and easy-to-use control strategies are an essential part of their clinical effectiveness due to the un-intuitive nature of magnetic field interaction. However, work on developing intelligent control for these devices has mainly been focused on general purpose endoscope navigation. In this work, we investigate the use of autonomous robotic control for magnetic colonoscope intervention via biopsy, another major component of clinical viability. We have developed control strategies with varying levels of robotic autonomy, including semi-autonomous routines for identifying and performing targeted biopsy, as well as random quadrant biopsy. We present and compare the performance of these approaches to magnetic endoscope biopsy against the use of a standard flexible endoscope on bench-top using a colonoscopy training simulator and silicone colon model. The semi-autonomous routines for targeted and random quadrant biopsy were shown to reduce user workload with comparable times to using a standard flexible endoscope.


  • Top Cited Papers

    Enabling the future of colonoscopy with intelligent and autonomous magnetic manipulation

    by James W. Martin, Bruno Scaglioni, Joseph C. Norton, Venkataraman Subramanian, Alberto Arezzo, Keith L. Obstein, Pietro Valdastri

    Early diagnosis of colorectal cancer substantially improves survival. However, over half of cases are diagnosed late due to the demand for colonoscopy—the ‘gold standard’ for screening—exceeding capacity. Colonoscopy is limited by the outdated design of conventional endoscopes, which are associated with high complexity of use, cost and pain. Magnetic endoscopes are a promising alternative and overcome the drawbacks of pain and cost, but they struggle to reach the translational stage as magnetic manipulation is complex and unintuitive. In this work, we use machine vision to develop intelligent and autonomous control of a magnetic endoscope, enabling non-expert users to effectively perform magnetic colonoscopy in vivo. We combine the use of robotics, computer vision and advanced control to offer an intuitive and effective endoscopic system. Moreover, we define the characteristics required to achieve autonomy in robotic endoscopy. The paradigm described here can be adopted in a variety of applications where navigation in unstructured environments is required, such as catheters, pancreatic endoscopy, bronchoscopy and gastroscopy. This work brings alternative endoscopic technologies closer to the translational stage, increasing the availability of early-stage cancer treatments.


  • Intelligent magnetic manipulation for gastrointestinal ultrasound

    by Joseph C. Norton, Piotr R. Slawinski, Holly S. Lay, James W. Martin, Benjamin F. Cox, Gerard Cummins, Marc P.Y. Desmulliez, Richard E. Clutton, Keith L. Obstein, Sandy Cochran, et al.

    A capsule robot uses magnetic control and microultrasound feedback for in situ autonomous positioning and diagnostics of microanatomy.