Yusuke Tsukahara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yusuke Tsukahara has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Kazushi Yamanaka
Department of Materials Processing, Tohoku University, Aoba 02, Sendai 980-8579, Japan
7 shared publications - Toshihiro Tsuji
Department of Materials Processing, Graduate School of Engineering, Tohoku University, Sendai 980-8579, Japan
4 shared publications Nobuo Takeda
Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan
3 shared publications- Nobuo Takeda
Ball Wave Inc.; T-Biz 503, 6-6-40, Aza Aoba, Aramaki, Aoba Sendai Miyagi 9890-8579 Japan
3 shared publications Noritaka Nakaso
Toppan Printing Co. Ltd
3 shared publicationsShingo Akao
Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan
3 shared publications
Latest Publications
- Open Access
- 30 May 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SG) , SG1051
Development of ball surface acoustic wave gas chromatograph for environmental monitoring in spacecraft and its application on the ground
For on-site analysis of surface materials on the Moon, planets, and small bodies and for the monitoring of air quality in crewed spacecraft, we have developed a portable gas chromatograph (GC) equipped with a ball surface acoustic wave (SAW) sensor. In this study, we fabricated a 10 cm cube GC that implements the forward flush method using two metal micro-electro-mechanical-system columns coated with different stationary phases in microchannels fabricated by wet etching and diffusion bonding of stainless-steel plates. Using this GC, we succeeded in analyzing 10 kinds of gas within 10 min. In addition, for the application of the ball SAW GC on the ground, we also developed a palm-sized GC with a single metal capillary column and used it in the analysis of the headspace gas of sake. We showed that the ratio of peak areas differed among odorants depending on the brand and brewing process of sake.
- 30 May 2022
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 61 (SG) , SG1051
Open AccessDevelopment of ball surface acoustic wave gas chromatograph for environmental monitoring in spacecraft and its application on the ground
For on-site analysis of surface materials on the Moon, planets, and small bodies and for the monitoring of air quality in crewed spacecraft, we have developed a portable gas chromatograph (GC) equipped with a ball surface acoustic wave (SAW) sensor. In this study, we fabricated a 10 cm cube GC that implements the forward flush method using two metal micro-electro-mechanical-system columns coated with different stationary phases in microchannels fabricated by wet etching and diffusion bonding of stainless-steel plates. Using this GC, we succeeded in analyzing 10 kinds of gas within 10 min. In addition, for the application of the ball SAW GC on the ground, we also developed a palm-sized GC with a single metal capillary column and used it in the analysis of the headspace gas of sake. We showed that the ratio of peak areas differed among odorants depending on the brand and brewing process of sake.
- Open Access
- 24 July 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (10) , 104007
Trace moisture measurement in natural gas mixtures with a single calibration for nitrogen background gas
The measurement and control of trace moisture is an important procedure to maintain and secure the quality and safety of pipeline systems for natural gas. The natural gas mix typically comprises methane, ethane, propane, some higher hydrocarbons, carbon dioxide and nitrogen. It is too impractical to perform additional calibrations of trace moisture measurement every time the combination of gas components in the natural gas mix is changed. This paper proposes a method to separate and compensate for the effect of the background gas composition from the trace moisture measurement by using two different frequencies in a trace moisture analyzer utilizing a ball surface acoustic wave (SAW) sensor. The experiment was performed by connecting the ball SAW trace moisture sensor to supplies of trace moisture in multiple background gases from the National Physical Laboratory (NPL) Multi-gas, Multi-pressure Standard Humidity Generator, and changing the composition of the background gases including N2, air, CH4, 80% CH4/20% C2H6, and 50% CH4/50% C2H6. At the nominal humidity frost-point values of −70 °C, −50 °C, −40 °C and −30 °C, the deviations due to the change of the background gases were within ± 1 °C in frost point.
- 24 July 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (10) , 104007
Open AccessTrace moisture measurement in natural gas mixtures with a single calibration for nitrogen background gas
The measurement and control of trace moisture is an important procedure to maintain and secure the quality and safety of pipeline systems for natural gas. The natural gas mix typically comprises methane, ethane, propane, some higher hydrocarbons, carbon dioxide and nitrogen. It is too impractical to perform additional calibrations of trace moisture measurement every time the combination of gas components in the natural gas mix is changed. This paper proposes a method to separate and compensate for the effect of the background gas composition from the trace moisture measurement by using two different frequencies in a trace moisture analyzer utilizing a ball surface acoustic wave (SAW) sensor. The experiment was performed by connecting the ball SAW trace moisture sensor to supplies of trace moisture in multiple background gases from the National Physical Laboratory (NPL) Multi-gas, Multi-pressure Standard Humidity Generator, and changing the composition of the background gases including N2, air, CH4, 80% CH4/20% C2H6, and 50% CH4/50% C2H6. At the nominal humidity frost-point values of −70 °C, −50 °C, −40 °C and −30 °C, the deviations due to the change of the background gases were within ± 1 °C in frost point.
- Open Access
- 17 April 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (9) , 094003
Dynamic calibration method for a trace moisture analyzer based on the quick response of a ball surface acoustic wave sensor
Measurement of trace moisture is important in industry to maintain the quality and yield of products, such as semiconductors, lithium-ion batteries, and organic electroluminescence devices. In the field, on-site calibration of a trace moisture analyzer is required to maintain its reliability. Given these circumstances, we previously developed a ball surface acoustic wave (SAW) sensor using SAW on spherical piezoelectric elements and reported its quick response as its advantage over other trace moisture analyzers. However, the ultimately short response time of less than 1 s has not been verified, and it has not yet been calibrated on-site. In this study, we developed a system for the injection of saturated water vapor to evaluate the quick response of a trace moisture analyzer, and we verified the quick response time of as short as 0.64 s. It is the shortest response time reported so far. In addition, to realize its on-site calibration, we developed a dynamic calibration method, which takes only 10 min, by the injection of saturated water vapor, in contrast to the presently available static calibration method that takes 10 h. Since this system consists of simple components, it can be downsized. Moreover, because it uses a small amount of saturated water vapor as the calibration gas, it is easy to prepare calibration gases in the field and may be applied to on-site calibration.
- 17 April 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (9) , 094003
Open AccessDynamic calibration method for a trace moisture analyzer based on the quick response of a ball surface acoustic wave sensor
Measurement of trace moisture is important in industry to maintain the quality and yield of products, such as semiconductors, lithium-ion batteries, and organic electroluminescence devices. In the field, on-site calibration of a trace moisture analyzer is required to maintain its reliability. Given these circumstances, we previously developed a ball surface acoustic wave (SAW) sensor using SAW on spherical piezoelectric elements and reported its quick response as its advantage over other trace moisture analyzers. However, the ultimately short response time of less than 1 s has not been verified, and it has not yet been calibrated on-site. In this study, we developed a system for the injection of saturated water vapor to evaluate the quick response of a trace moisture analyzer, and we verified the quick response time of as short as 0.64 s. It is the shortest response time reported so far. In addition, to realize its on-site calibration, we developed a dynamic calibration method, which takes only 10 min, by the injection of saturated water vapor, in contrast to the presently available static calibration method that takes 10 h. Since this system consists of simple components, it can be downsized. Moreover, because it uses a small amount of saturated water vapor as the calibration gas, it is easy to prepare calibration gases in the field and may be applied to on-site calibration.
- 26 October 2018
- Published by Wiley
- p. 241-260
The Interaction Between a Proton and the Atomic Network in Amorphous Silica Glass Made a Highly Sensitive Trace Moisture Sensor
- 26 October 2018
- Published by Wiley
- p. 241-260
The Interaction Between a Proton and the Atomic Network in Amorphous Silica Glass Made a Highly Sensitive Trace Moisture Sensor
- Open Access
A Novel Method and an Equipment for Generating the Standard Moisture in Gas Flowing through a Pipe
When inert gas containing water molecules flows into a metal pipe, the water molecules cannot exit instantaneously from the outlet of the pipe but are captured at adsorption sites on the inner surface of the pipe until most of the sites are occupied. A theoretical model and a subsequent experiment in this article show that the delay time depends on the amount of moisture level; the higher the moisture-level, the shorter the delay time. Based on the result, we propose a new method and its implementation to the validation of a standard moisture generation to be used in the field measurement such as in factories and pipe lines.
Open AccessA Novel Method and an Equipment for Generating the Standard Moisture in Gas Flowing through a Pipe
When inert gas containing water molecules flows into a metal pipe, the water molecules cannot exit instantaneously from the outlet of the pipe but are captured at adsorption sites on the inner surface of the pipe until most of the sites are occupied. A theoretical model and a subsequent experiment in this article show that the delay time depends on the amount of moisture level; the higher the moisture-level, the shorter the delay time. Based on the result, we propose a new method and its implementation to the validation of a standard moisture generation to be used in the field measurement such as in factories and pipe lines.
- Open Access
- 13 May 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (7) , 1-8
A Thermodynamic Consideration on the Mechanism of Ultrasensitive Moisture Sensing by Amorphous Silica
- 13 May 2017
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 38 (7) , 1-8
Open AccessA Thermodynamic Consideration on the Mechanism of Ultrasensitive Moisture Sensing by Amorphous Silica
- Open Access
- 1 January 2014
- Published by Japan Institute of Metals in MATERIALS TRANSACTIONS
- Vol. 55 (7) , 988-993
Detection of Trace Water Vapor Using SiOx-Coated Ball SAW Sensor
In manufacturing process of semiconductor, blue light emitting diode (LED), and lithium ion battery, detection and monitoring of trace water vapor (x) on ball SAW sensor using sol–gel method. It was confirmed that SiOx-coated ball SAW sensor could detect water vapor in a wide range from −95 to 0°C in frost point (0.035–6.0 × 103 µmol/mol in concentration) and its response time to frost point change from −70 to −60°C was one half of that of a chilled-mirror hygrometer.
- 1 January 2014
- Published by Japan Institute of Metals in MATERIALS TRANSACTIONS
- Vol. 55 (7) , 988-993
Open AccessDetection of Trace Water Vapor Using SiOx-Coated Ball SAW Sensor
In manufacturing process of semiconductor, blue light emitting diode (LED), and lithium ion battery, detection and monitoring of trace water vapor (x) on ball SAW sensor using sol–gel method. It was confirmed that SiOx-coated ball SAW sensor could detect water vapor in a wide range from −95 to 0°C in frost point (0.035–6.0 × 103 µmol/mol in concentration) and its response time to frost point change from −70 to −60°C was one half of that of a chilled-mirror hygrometer.
- 24 November 2003
- Published by AIP Publishing in Applied Physics Letters
- Vol. 83 (22) , 4649-4651
Surface acoustic waves on a sphere with divergent, focusing, and collimating beam shapes excited by an interdigital transducer
The surface acoustic wave (SAW) device on a ball is expected to provide high-performance sensors. Since we must deal with three-dimensional wave fields for precise design of ball SAW devices, numerical methods, such as the finite element method, will require too many elements. Therefore, we applied an analytical solution to a practical calculation of the full-field acoustic waves. For an IDT aperture of 6° and 80° with a wave number parameter of 45, the SAW has a divergent beam and a focusing beam, respectively. For an intermediate aperture of 30°, the SAW forms a collimating beam. This calculation confirmed the possibility of an extremely sensitive sensor with diffraction-free SAWs without disturbance by spurious bulk waves.
- 24 November 2003
- Published by AIP Publishing in Applied Physics Letters
- Vol. 83 (22) , 4649-4651
Surface acoustic waves on a sphere with divergent, focusing, and collimating beam shapes excited by an interdigital transducer
The surface acoustic wave (SAW) device on a ball is expected to provide high-performance sensors. Since we must deal with three-dimensional wave fields for precise design of ball SAW devices, numerical methods, such as the finite element method, will require too many elements. Therefore, we applied an analytical solution to a practical calculation of the full-field acoustic waves. For an IDT aperture of 6° and 80° with a wave number parameter of 45, the SAW has a divergent beam and a focusing beam, respectively. For an intermediate aperture of 30°, the SAW forms a collimating beam. This calculation confirmed the possibility of an extremely sensitive sensor with diffraction-free SAWs without disturbance by spurious bulk waves.
- 15 April 2002
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 41 (Part 1, No) , 2256-2261
Acoustic Fields of Bulk Acoustic Waves Excited by Phase Velocity Scanning of Laser Interference Fringes
- 15 April 2002
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 41 (Part 1, No) , 2256-2261
Acoustic Fields of Bulk Acoustic Waves Excited by Phase Velocity Scanning of Laser Interference Fringes
- 30 October 2000
- Published by AIP Publishing in Applied Physics Letters
- Vol. 77 (18) , 2926-2928
Observation of diffraction-free propagation of surface acoustic waves around a homogeneous isotropic solid sphere
This letter shows an unexpected phenomenon where a surface acoustic wave (Rayleigh wave) excited by a line source with a finite length on a solid sphere propagates along the great circle in a direction perpendicular to the line source without beam spreading due to diffraction. In experiments, a piezoelectric transducer, 1.5 mm in width and 20 mm in length, was glued on a surface of a glass ball, 80 mm in diameter, as a line source with a finite length. A beam of Rayleigh waves with frequencies centered at 1.1 MHz was excited in either direction perpendicular to the transducer length. A receiving transducer with a circular aperture, 2 mm in diameter, was used in direct contact with the surface to detect the distribution of vibration over the surface of the ball. It was observed that the excited Rayleigh wave propagated along a great circle of the ball for at least four roundtrips. The beam was confined within a narrow path around the ball, the width of which was no more than 20 mm.
- 30 October 2000
- Published by AIP Publishing in Applied Physics Letters
- Vol. 77 (18) , 2926-2928
Observation of diffraction-free propagation of surface acoustic waves around a homogeneous isotropic solid sphere
This letter shows an unexpected phenomenon where a surface acoustic wave (Rayleigh wave) excited by a line source with a finite length on a solid sphere propagates along the great circle in a direction perpendicular to the line source without beam spreading due to diffraction. In experiments, a piezoelectric transducer, 1.5 mm in width and 20 mm in length, was glued on a surface of a glass ball, 80 mm in diameter, as a line source with a finite length. A beam of Rayleigh waves with frequencies centered at 1.1 MHz was excited in either direction perpendicular to the transducer length. A receiving transducer with a circular aperture, 2 mm in diameter, was used in direct contact with the surface to detect the distribution of vibration over the surface of the ball. It was observed that the excited Rayleigh wave propagated along a great circle of the ball for at least four roundtrips. The beam was confined within a narrow path around the ball, the width of which was no more than 20 mm.