TTToshihiro Tsuji

Toshihiro Tsuji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Toshihiro Tsuji has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Nobuo Takeda

    Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan

    6 shared publications
  • Shingo Akao

    Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan

    6 shared publications
  • Toru Oizumi

    Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan

    6 shared publications
  • Kazushi Yamanaka

    Ball Wave Inc, Sendai, Miyagi, JAPAN

    4 shared publications
  • Yusuke Tsukahara

    Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan

    4 shared publications
  • Hideyuki Fukushi

    Tohoku Univ, Ball Wave Inc, Business Incubator T Biz 501, Aoba Ku, 6-6-40 Aza Aoba, Sendai, Miyagi 98908579, Japan

    3 shared publications

Latest Publications

  • Open Access

    Development of ball surface acoustic wave gas chromatograph for environmental monitoring in spacecraft and its application on the ground

    by Takamitsu Iwaya, Shingo Akao, Kazushi Yamanaka, Tatsuhiro Okano, Nobuo Takeda, Yusuke Tsukahara, Toru Oizumi, Hideyuki Fukushi, Maki Sugawara, Toshihiro Tsuji, et al.

    For on-site analysis of surface materials on the Moon, planets, and small bodies and for the monitoring of air quality in crewed spacecraft, we have developed a portable gas chromatograph (GC) equipped with a ball surface acoustic wave (SAW) sensor. In this study, we fabricated a 10 cm cube GC that implements the forward flush method using two metal micro-electro-mechanical-system columns coated with different stationary phases in microchannels fabricated by wet etching and diffusion bonding of stainless-steel plates. Using this GC, we succeeded in analyzing 10 kinds of gas within 10 min. In addition, for the application of the ball SAW GC on the ground, we also developed a palm-sized GC with a single metal capillary column and used it in the analysis of the headspace gas of sake. We showed that the ratio of peak areas differed among odorants depending on the brand and brewing process of sake.


  • Toward an ultra-high resolution phased-array system for 3D ultrasonic imaging of solids

    by Yoshikazu Ohara, Marcel C. Remillieux, Tomomi Onuma, Kosuke Tsunoda, Toshihiro Tsuji, Tsuyoshi Mihara

    Ultrasonic phased-array (PA) systems have been widely adopted in the field of nondestructive evaluation for material characterization and imaging of internal defects. Whereas many defects exhibit complex three-dimensional structures, most PA systems provide only two-dimensional images. In this Letter, we demonstrate the ability to create high-resolution 3D images of internal defects using a PA system based on a piezoelectric and laser ultrasonic system (PLUS). The PLUS combines a piezoelectric transmitter to insonify the structure to be inspected with a laser Doppler vibrometer to create a matrix array of receiver points without contact. The small size of the laser beam results in an ultra-multiple number of elements on the order of thousands, which is impossible to achieve with a conventional piezoelectric matrix array transducer. An emission from a piezoelectric transmitter compensates for the intrinsically low sensitivity of a laser Doppler vibrometer. After formulating the 3D imaging algorithm of the PLUS, we demonstrate that the PLUS with 4096 receiving points (i.e., 64 × 64 points) achieves high-resolution 3D imaging in a specimen with a flat bottom hole. We also visualize the complex structure of stress corrosion cracking. We believe that the 3D imaging capability of the PLUS may open up new avenues to the accurate evaluation of material strength, the identification of the types of defects, and the elucidation of the mechanisms of defect initiation.


  • Open Access

    Dynamic calibration method for a trace moisture analyzer based on the quick response of a ball surface acoustic wave sensor

    by Takamitsu Iwaya, Shingo Akao, Tatsuhiro Okano, Nobuo Takeda, Toru Oizumi, Toshihiro Tsuji, Hideyuki Fukushi, Maki Sugawara, Yusuke Tsukahara, Kazushi Yamanaka

    Measurement of trace moisture is important in industry to maintain the quality and yield of products, such as semiconductors, lithium-ion batteries, and organic electroluminescence devices. In the field, on-site calibration of a trace moisture analyzer is required to maintain its reliability. Given these circumstances, we previously developed a ball surface acoustic wave (SAW) sensor using SAW on spherical piezoelectric elements and reported its quick response as its advantage over other trace moisture analyzers. However, the ultimately short response time of less than 1 s has not been verified, and it has not yet been calibrated on-site. In this study, we developed a system for the injection of saturated water vapor to evaluate the quick response of a trace moisture analyzer, and we verified the quick response time of as short as 0.64 s. It is the shortest response time reported so far. In addition, to realize its on-site calibration, we developed a dynamic calibration method, which takes only 10 min, by the injection of saturated water vapor, in contrast to the presently available static calibration method that takes 10 h. Since this system consists of simple components, it can be downsized. Moreover, because it uses a small amount of saturated water vapor as the calibration gas, it is easy to prepare calibration gases in the field and may be applied to on-site calibration.


  • Open Access

    A Novel Method and an Equipment for Generating the Standard Moisture in Gas Flowing through a Pipe

    by Yusuke Tsukahara, Osamu Hirayama, Nobuo Takeda, Toru Oizumi, Hideyuki Fukushi, Nagisa Sato, Toshihiro Tsuji, Kazushi Yamanaka, Shingo Akao

    When inert gas containing water molecules flows into a metal pipe, the water molecules cannot exit instantaneously from the outlet of the pipe but are captured at adsorption sites on the inner surface of the pipe until most of the sites are occupied. A theoretical model and a subsequent experiment in this article show that the delay time depends on the amount of moisture level; the higher the moisture-level, the shorter the delay time. Based on the result, we propose a new method and its implementation to the validation of a standard moisture generation to be used in the field measurement such as in factories and pipe lines.


  • Development of ball surface acoustic wave trace moisture analyzer using burst waveform undersampling circuit

    by Toshihiro Tsuji, Toru Oizumi, Hideyuki Fukushi, Nobuo Takeda, Shingo Akao, Yusuke Tsukahara, Kazushi Yamanaka

    The measurement and control of trace moisture, where the water concentration is lower than 1 ppmv [−76.2 °C for the frost point (°CFP)], are essential for improving the yield rate of semiconductor devices and for ensuring their reliability. A ball surface acoustic wave (SAW) sensor with a sol-gel silica coating exhibited useful characteristics for a trace moisture analyzer (TMA) when the temperature drift of the delay time output was precisely compensated using two-frequency measurement (TFM), where the temperature-compensated relative delay time change (RDTC) was obtained by subtracting the RDTC at the fundamental frequency from that at the third harmonic frequency on an identical propagation path. However, the cost of the measurement circuit was a problem. In this study, a burst waveform undersampling (BUS) circuit based on the theory of undersampling measurement was developed as a practical means. The BUS circuit was useful for precise temperature compensation of the RDTC, and the ball SAW TMA was prototyped by calibrating the RDTC using a TMA based on cavity ring-down spectroscopy (CRDS), which is the most reliable method for trace moisture measurement. The ball SAW TMA outputted a similar concentration to that obtained by the CRDS TMA, and its response time at a set concentration in N2 with a flow rate of 1 l/min was about half that of the CRDS TMA, suggesting that moisture of −80 °CFP was measured within only 1 min. The detection limit at a signal-to-noise ratio of 3 was estimated to be 0.05 ppbv, comparable with that of the CRDS TMA. From these results, it was demonstrated that a practical ball SAW TMA can be realized using the developed BUS circuit.


  • Moisture adsorption desorption characteristics of stainless steel tubing measured by ball surface acoustic wave trace moisture analyzer

    by Toshishiro Tsuji, Shingo Akao, Toru Oizumi, Nobuo Takeda, Yusuke Tsukahara, Kazushi Yamanaka

    A ball surface acoustic wave (SAW) trace moisture analyzer (TMA) was applied to measuring the adsorption and desorption (AD) characteristics of a stainless steel tube. For the first time, two-frequency measurement for precise temperature compensation was attempted at intervals of 3 s using a burst waveform undersampling circuit. We succeeded in measuring the variations of moisture transit time and dry-down dynamics caused by inner surface treatments such as bright annealing (BA), electropolishing (EP), and electrochemical buffing (ECB) using a sample-tube length of only 100 mm at a flow rate of 0.1 L/min. Net moisture adsorption was evaluated from the measured adsorption subtracted by the background adsorption. As a result, it was found that the adsorption on the ECB tube was smaller than those on EP and BA tubes by 1/3 and 1/4, respectively, at a baseline concentration of 13 ppbv. From these results, it was demonstrated that the ball SAW TMA could be used for measuring the AD characteristics of stainless steel tubes with various surface treatments.


  • Temperature compensation of ball surface acoustic wave sensor by two-frequency measurement using undersampling

    by Toshihiro Tsuji, Toru Oizumi, Nobuo Takeda, Shingo Akao, Yusuke Tsukahara, Kazushi Yamanaka

    To realize a practical two-frequency measurement (TFM) system for precise temperature compensation in a ball surface acoustic wave (SAW) sensor, the application of undersampling (US) was investigated. The subtraction coefficient for the temperature compensation in US was theoretically explained. The principle of the TFM system using US was simulated by the decimation of the oversampling (OS) waveform after applying a narrow band-pass filter, and the delay time was measured using a wavelet transform. In the application of the method to trace moisture measurement, the delay time response due to US matched that due to OS with a correlation coefficient higher than 0.9999. Although rms noise was increased by US, the response to the concentration change of 4–17 nmol/mol was measured with a signal-to-noise ratio higher than 20. From these results, it was shown that the precise output of the ball SAW sensor could be obtained even when using US, which was equivalent to that using OS.


  • Open Access

    Detection of Trace Water Vapor Using SiOx-Coated Ball SAW Sensor

    by Kosuke Takayanagi, Shingo Akao, Takayuki Yanagisawa, Noritaka Nakaso, Yusuke Tsukahara, Satoshi Hagihara, Toru Oizumi, Nobuo Takeda, Toshihiro Tsuji, Kazushi Yamanaka

    In manufacturing process of semiconductor, blue light emitting diode (LED), and lithium ion battery, detection and monitoring of trace water vapor (x) on ball SAW sensor using sol–gel method. It was confirmed that SiOx-coated ball SAW sensor could detect water vapor in a wide range from −95 to 0°C in frost point (0.035–6.0 × 103 µmol/mol in concentration) and its response time to frost point change from −70 to −60°C was one half of that of a chilled-mirror hygrometer.


  • Development of High Precision Metal Micro-Electro-Mechanical-Systems Column for Portable Surface Acoustic Wave Gas Chromatograph

    by Takamitsu Iwaya, Shingo Akao, Toshihiro Sakamoto, Toshihiro Tsuji, Noritaka Nakaso, Kazushi Yamanaka