Peter Bæk Skou
Peter Bæk Skou has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Frans van Den Berg
Department of Food Science, Faculty of Science, University of Copenhagen, Rolighedsvej 26, DK-1958 Frederiksberg C, Denmark
4 shared publications - Søren Balling Engelsen
University of Copenhagen Rolighedsvej 26
3 shared publications - Carl Emil Eskildsen
Department of Food Science, University of Copenhagen, DK-1958 Frederiksberg, Denmark
2 shared publications Dorrit Thaysen
Arla Foods Ingredients, Sønderupvej 26, DK-6920 Videbæk, Denmark
2 shared publications- Margherita Tonolini
Department of Food Science, Faculty of Life Sciences, University of Copenhagen, Frederiksberg C, Denmark
2 shared publications Age K. Smilde
Swammerdam Institute for Life Sciences, University of Amsterdam, NL-1098 XH, Amsterdam, the Netherlands
1 shared publication
Latest Publications
- Open Access
- 3 March 2023
- Published by Elsevier in Journal of Food Engineering
- Vol. 350
Near-infrared spectroscopy as a process analytical technology tool for monitoring performance of membrane filtration in a whey protein fractionation process.
- 3 March 2023
- Published by Elsevier in Journal of Food Engineering
- Vol. 350
Open AccessNear-infrared spectroscopy as a process analytical technology tool for monitoring performance of membrane filtration in a whey protein fractionation process.
- Open Access
- 1 November 2021
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1185, 339073
Orthogonality constrained inverse regression to improve model selectivity and analyte predictions from vibrational spectroscopic measurements
- 1 November 2021
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1185, 339073
Open AccessOrthogonality constrained inverse regression to improve model selectivity and analyte predictions from vibrational spectroscopic measurements
- Open Access
- 28 January 2021
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 75 (6) , 718-727
Prediction of α-Lactalbumin and β-Lactoglobulin Composition of Aqueous Whey Solutions Using Fourier Transform Mid-Infrared Spectroscopy and Near-Infrared Spectroscopy
Characterization and quantification of individual whey proteins are of crucial importance to many industrial dairy processes. Labor intensive wet-chemical methods are still being used for this purpose, but a rapid quantification method for individual whey proteins is highly desired. This work investigate the utility of Fourier transform mid-infrared spectroscopy and Fourier transform near-infrared spectroscopy for rapid quantification of the two main whey proteins (β-lactoglobulin and α-lactalbumin) in complex aqueous whey solutions simulating production process streams. MIR and NIR spectra obtained on whey samples with known and varying amounts of the proteins of interest and are used to develop partial least squares prediction models. Selection of informative wavelength regions allowed for prediction of β-lactoglobulin and α-lactalbumin concentrations with very high precision and accuracy (root mean square error of cross-validation, or RMSECV, of 0.6% and R 2 of 0.99 for NIR), demonstrating the potential of being implemented for rapid in-line monitoring of protein composition in industrial whey streams. Two-dimensional MIR-NIR correlation spectroscopy is used to identify the most informative parts of the NIR spectra in relation to protein secondary structure. In addition multivariate curve resolution is applied to the MIR data to resolve mixture spectra and to elucidate the spectral ranges that were most useful in distinguishing between the two whey proteins. The study concludes that NIR spectroscopy has potential for accurate in-line protein quantification and overall secondary protein structure quantification which open new possibilities for in-line industrial applications.
- 28 January 2021
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 75 (6) , 718-727
Open AccessPrediction of α-Lactalbumin and β-Lactoglobulin Composition of Aqueous Whey Solutions Using Fourier Transform Mid-Infrared Spectroscopy and Near-Infrared Spectroscopy
Characterization and quantification of individual whey proteins are of crucial importance to many industrial dairy processes. Labor intensive wet-chemical methods are still being used for this purpose, but a rapid quantification method for individual whey proteins is highly desired. This work investigate the utility of Fourier transform mid-infrared spectroscopy and Fourier transform near-infrared spectroscopy for rapid quantification of the two main whey proteins (β-lactoglobulin and α-lactalbumin) in complex aqueous whey solutions simulating production process streams. MIR and NIR spectra obtained on whey samples with known and varying amounts of the proteins of interest and are used to develop partial least squares prediction models. Selection of informative wavelength regions allowed for prediction of β-lactoglobulin and α-lactalbumin concentrations with very high precision and accuracy (root mean square error of cross-validation, or RMSECV, of 0.6% and R 2 of 0.99 for NIR), demonstrating the potential of being implemented for rapid in-line monitoring of protein composition in industrial whey streams. Two-dimensional MIR-NIR correlation spectroscopy is used to identify the most informative parts of the NIR spectra in relation to protein secondary structure. In addition multivariate curve resolution is applied to the MIR data to resolve mixture spectra and to elucidate the spectral ranges that were most useful in distinguishing between the two whey proteins. The study concludes that NIR spectroscopy has potential for accurate in-line protein quantification and overall secondary protein structure quantification which open new possibilities for in-line industrial applications.
- 1 January 2018
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 101 (1) , 135-146
Chemical characterization by gas chromatography-mass spectrometry and inductively coupled plasma-optical emission spectroscopy of membrane permeates from an industrial dairy ingredient production used as process water
Reusing reverse osmosis (RO) membrane permeate instead of potable water in the dairy industry is a very appealing tactic. However, to ensure safe use, the quality of reclaimed water must be guaranteed. To do this, qualitative and quantitative information about which compounds permeate the membranes must be established. In the present study, we provide a detailed characterization of ultrafiltration, RO, and RO polisher (ROP) permeate with regard to organic and inorganic compounds. Results indicate that smaller molecules and elements (such as phosphate, but mainly urea and boron) pass the membrane, and a small set of larger molecules (long-chain fatty acids, glycerol-phosphate, and glutamic acid) are found as well, though in minute concentrations (<0.2 µM). Growth experiments with 2 urease-positive microorganisms, isolated from RO permeate, showed that the nutrient content in the ROP permeate supports limited growth of 1 of the 2 isolates, indicating that the ROP permeate may not be guaranteed to be stable during protracted storage.
- 1 January 2018
- Published by American Dairy Science Association in Journal of Dairy Science
- Vol. 101 (1) , 135-146
Chemical characterization by gas chromatography-mass spectrometry and inductively coupled plasma-optical emission spectroscopy of membrane permeates from an industrial dairy ingredient production used as process water
Reusing reverse osmosis (RO) membrane permeate instead of potable water in the dairy industry is a very appealing tactic. However, to ensure safe use, the quality of reclaimed water must be guaranteed. To do this, qualitative and quantitative information about which compounds permeate the membranes must be established. In the present study, we provide a detailed characterization of ultrafiltration, RO, and RO polisher (ROP) permeate with regard to organic and inorganic compounds. Results indicate that smaller molecules and elements (such as phosphate, but mainly urea and boron) pass the membrane, and a small set of larger molecules (long-chain fatty acids, glycerol-phosphate, and glutamic acid) are found as well, though in minute concentrations (<0.2 µM). Growth experiments with 2 urease-positive microorganisms, isolated from RO permeate, showed that the nutrient content in the ROP permeate supports limited growth of 1 of the 2 isolates, indicating that the ROP permeate may not be guaranteed to be stable during protracted storage.
- 21 September 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (39) , 5757-5762
SERS spectroscopy for detection of hydrogen cyanide in breath from children colonised with P. aeruginosa
There is a need for a fast and non-invasive tool to detect Pseudomonas aeruginosa airway colonisation in cystic fibrosis (CF) patients unable to expectorate. Fifty CF children and 19 controls aged 5–17 years were included in the feasibility study. A surface-enhanced Raman spectroscopy (SERS) nanochip optimised for detection of trace amounts of the P. aeruginosa biomarker hydrogen cyanide (HCN) was mounted inside a Tedlar bag, which the patient breathed into. The SERS chip was then analysed in a Raman spectrometer, investigating the CN peak at 2131 cm−1 and correlated with sputum cultures. One new P. aeruginosa colonisation occurred during the trial period. The CN peak intensity was enhanced in this sample in contrast to the subject's 3 other samples. Three additional patients had intense CN SERS signals from their breath, but no P. aeruginosa was cultured from their sputum. It is concluded that SERS spectroscopy can be developed into an easy to use hypersensitive clinical prescreening method for detection of HCN in human breath.
- 21 September 2017
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 9 (39) , 5757-5762
SERS spectroscopy for detection of hydrogen cyanide in breath from children colonised with P. aeruginosa
There is a need for a fast and non-invasive tool to detect Pseudomonas aeruginosa airway colonisation in cystic fibrosis (CF) patients unable to expectorate. Fifty CF children and 19 controls aged 5–17 years were included in the feasibility study. A surface-enhanced Raman spectroscopy (SERS) nanochip optimised for detection of trace amounts of the P. aeruginosa biomarker hydrogen cyanide (HCN) was mounted inside a Tedlar bag, which the patient breathed into. The SERS chip was then analysed in a Raman spectrometer, investigating the CN peak at 2131 cm−1 and correlated with sputum cultures. One new P. aeruginosa colonisation occurred during the trial period. The CN peak intensity was enhanced in this sample in contrast to the subject's 3 other samples. Three additional patients had intense CN SERS signals from their breath, but no P. aeruginosa was cultured from their sputum. It is concluded that SERS spectroscopy can be developed into an easy to use hypersensitive clinical prescreening method for detection of HCN in human breath.
- Top Cited PapersOpen Access
- 1 June 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1503, 57-64
Gas chromatography – mass spectrometry data processing made easy
- 1 June 2017
- Published by Elsevier in Journal of Chromatography A
- Vol. 1503, 57-64
Top Cited PapersOpen AccessGas chromatography – mass spectrometry data processing made easy
- 12 May 2017
- Published by Wiley in Journal of Chemometrics
- Vol. 31 (7)
Tutorial – applying extreme value theory to characterize food‐processing systems
This tutorial presents extreme value theory (EVT) as an analytical tool in process characterization and shows its potential to describe production performance, eg, across different factories, via reliable estimates of the frequency and scale of extreme events. Two alternative EVT methods are discussed: point over threshold and block maxima. We illustrate the theoretical framework for EVT by process data from two different examples from the food‐processing industry. Finally, we discuss limitations, decisions, and possibilities when applying EVT for process data.
- 12 May 2017
- Published by Wiley in Journal of Chemometrics
- Vol. 31 (7)
Tutorial – applying extreme value theory to characterize food‐processing systems
This tutorial presents extreme value theory (EVT) as an analytical tool in process characterization and shows its potential to describe production performance, eg, across different factories, via reliable estimates of the frequency and scale of extreme events. Two alternative EVT methods are discussed: point over threshold and block maxima. We illustrate the theoretical framework for EVT by process data from two different examples from the food‐processing industry. Finally, we discuss limitations, decisions, and possibilities when applying EVT for process data.
- 9 December 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 71 (3) , 410-421
Monitoring Process Water Quality Using Near Infrared Spectroscopy and Partial Least Squares Regression with Prediction Uncertainty Estimation
Reuse of process water in dairy ingredient production—and food processing in general—opens the possibility for sustainable water regimes. Membrane filtration processes are an attractive source of process water recovery since the technology is already utilized in the dairy industry and its use is expected to grow considerably. At Arla Foods Ingredients (AFI), permeate from a reverse osmosis polisher filtration unit is sought to be reused as process water, replacing the intake of potable water. However, as for all dairy and food producers, the process water quality must be monitored continuously to ensure food safety. In the present investigation we found urea to be the main organic compound, which potentially could represent a microbiological risk. Near infrared spectroscopy (NIRS) in combination with multivariate modeling has a long-standing reputation as a real-time measurement technology in quality assurance. Urea was quantified Using NIRS and partial least squares regression (PLS) in the concentration range 50–200 ppm (RMSEP = 12 ppm, R 2 = 0.88) in laboratory settings with potential for on-line application. A drawback of using NIRS together with PLS is that uncertainty estimates are seldom reported but essential to establishing real-time risk assessment. In a multivariate regression setting, sample-specific prediction errors are needed, which complicates the uncertainty estimation. We give a straightforward strategy for implementing an already developed, but seldom used, method for estimating sample-specific prediction uncertainty. We also suggest an improvement. Comparing independent reference analyses with the sample-specific prediction error estimates showed that the method worked on industrial samples when the model was appropriate and unbiased, and was simple to implement.
- 9 December 2016
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 71 (3) , 410-421
Monitoring Process Water Quality Using Near Infrared Spectroscopy and Partial Least Squares Regression with Prediction Uncertainty Estimation
Reuse of process water in dairy ingredient production—and food processing in general—opens the possibility for sustainable water regimes. Membrane filtration processes are an attractive source of process water recovery since the technology is already utilized in the dairy industry and its use is expected to grow considerably. At Arla Foods Ingredients (AFI), permeate from a reverse osmosis polisher filtration unit is sought to be reused as process water, replacing the intake of potable water. However, as for all dairy and food producers, the process water quality must be monitored continuously to ensure food safety. In the present investigation we found urea to be the main organic compound, which potentially could represent a microbiological risk. Near infrared spectroscopy (NIRS) in combination with multivariate modeling has a long-standing reputation as a real-time measurement technology in quality assurance. Urea was quantified Using NIRS and partial least squares regression (PLS) in the concentration range 50–200 ppm (RMSEP = 12 ppm, R 2 = 0.88) in laboratory settings with potential for on-line application. A drawback of using NIRS together with PLS is that uncertainty estimates are seldom reported but essential to establishing real-time risk assessment. In a multivariate regression setting, sample-specific prediction errors are needed, which complicates the uncertainty estimation. We give a straightforward strategy for implementing an already developed, but seldom used, method for estimating sample-specific prediction uncertainty. We also suggest an improvement. Comparing independent reference analyses with the sample-specific prediction error estimates showed that the method worked on industrial samples when the model was appropriate and unbiased, and was simple to implement.