Margherita Tonolini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Margherita Tonolini has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Peter Bæk Skou
Arla Foods Ingredients Group P/S, DK-6920, Videbæk, Denmark
2 shared publications Carl Emil Eskildsen
Nofima AS, Norwegian Institute of Food, Fisheries and Aquaculture Research, Muninbakken 9‐13, NO‐9291, Tromsø, Norway
1 shared publicationColin Ray
Arla Foods Ingredients Group P/S, Videbæk, Denmark
1 shared publicationFrans van Den Berg
Department of Food Science, University of Copenhagen Faculty of Science, Frederiksberg, Denmark
1 shared publication- Frans van Den Berg
Department of Food Science, Faculty of Science, University of Copenhagen, Rolighedsvej 26, DK-1958 Frederiksberg C, Denmark
1 shared publication Joanna Wawrzynczyk
Oils & Fats Application Research, Novozymes AS, Lyngby, Hovedstaden, Denmark
1 shared publication
Latest Publications
- 6 October 2023
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 77 (12) , 1333-1343
On-Line Monitoring of Enzymatic Degumming of Soybean Oil Using Near-Infrared Spectroscopy
Degumming is an oil refinement process in which the naturally occurring phospholipids in crude vegetable oils are removed. Enzymatic degumming results in higher oil yield and more cost-efficient processing compared to traditional degumming processes using only water or acid. Phospholipase C hydrolyses phospholipids into diglycerides and phosphate groups during degumming. The diglyceride content can therefore be considered a good indicator of the state of the enzymatic reaction. This study investigates the use of near-infrared (NIR) spectroscopy and chemometrics to monitor the degumming process by quantifying diglycerides in soybean oil in both off-line and on-line settings. Fifteen enzymatic degumming lab scale batches originating from a definitive screening design (with varying water, acid, and enzyme dosages) were investigated with the aim to develop a NIR spectroscopy prediction method. By applying tailored preprocessing and variable selection methods, the diglyceride content can be predicted with a root mean square error of prediction of 0.06% (w/w) for the off-line set-up and 0.07% (w/w) for the on-line set-up. The results show that the diglyceride content is a good indicator of the enzyme performance and that NIR spectroscopy is a suitable analytical technique for robust real-time diglyceride quantification.
- 6 October 2023
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 77 (12) , 1333-1343
On-Line Monitoring of Enzymatic Degumming of Soybean Oil Using Near-Infrared Spectroscopy
Degumming is an oil refinement process in which the naturally occurring phospholipids in crude vegetable oils are removed. Enzymatic degumming results in higher oil yield and more cost-efficient processing compared to traditional degumming processes using only water or acid. Phospholipase C hydrolyses phospholipids into diglycerides and phosphate groups during degumming. The diglyceride content can therefore be considered a good indicator of the state of the enzymatic reaction. This study investigates the use of near-infrared (NIR) spectroscopy and chemometrics to monitor the degumming process by quantifying diglycerides in soybean oil in both off-line and on-line settings. Fifteen enzymatic degumming lab scale batches originating from a definitive screening design (with varying water, acid, and enzyme dosages) were investigated with the aim to develop a NIR spectroscopy prediction method. By applying tailored preprocessing and variable selection methods, the diglyceride content can be predicted with a root mean square error of prediction of 0.06% (w/w) for the off-line set-up and 0.07% (w/w) for the on-line set-up. The results show that the diglyceride content is a good indicator of the enzyme performance and that NIR spectroscopy is a suitable analytical technique for robust real-time diglyceride quantification.
- 22 May 2023
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 31 (4) , 186-195
Unbiased prediction errors for partial least squares regression models: Choosing a representative error estimator for process monitoring
Partial least squares (PLS) regression is widely used to predict chemical analytes from spectroscopic data, thus reducing the need for expensive and time-consuming wet chemical reference analysis in industrial process monitoring. However, predictions via PLS by definition carry sample-specific errors, and estimation of these errors is essential for correct interpretation of results. To increase trust in PLS regression-based predictions, reliable prediction error estimates must be reported. This can be achieved by determining realistic sample-specific prediction errors using an unbiased mean squared prediction error estimate. This work provides a guide for estimating sample-specific prediction errors, showing the importance of choosing an appropriate error estimator prior to deploying PLS models for industrial applications. We reviewed recent and established methods for estimating the sample-specific prediction error and test them through simulation studies. The methods were subsequently applied for estimating prediction errors in two real-life datasets from the food ingredients industry, where near-infrared spectroscopy was used to quantify i) urea in process water and ii) individual protein concentrations in ultrafiltration retentates from a protein fractionation process. Both the simulations and real data examples showed that the mean squared error of calibration is always a downward biased estimator. Although leave-one-out-cross-validation performed surprisingly well in the data analysed in this work, this paper demonstrated that the appropriate choice of error estimator requires the user to make an informed, data-centered decision.
- 22 May 2023
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 31 (4) , 186-195
Unbiased prediction errors for partial least squares regression models: Choosing a representative error estimator for process monitoring
Partial least squares (PLS) regression is widely used to predict chemical analytes from spectroscopic data, thus reducing the need for expensive and time-consuming wet chemical reference analysis in industrial process monitoring. However, predictions via PLS by definition carry sample-specific errors, and estimation of these errors is essential for correct interpretation of results. To increase trust in PLS regression-based predictions, reliable prediction error estimates must be reported. This can be achieved by determining realistic sample-specific prediction errors using an unbiased mean squared prediction error estimate. This work provides a guide for estimating sample-specific prediction errors, showing the importance of choosing an appropriate error estimator prior to deploying PLS models for industrial applications. We reviewed recent and established methods for estimating the sample-specific prediction error and test them through simulation studies. The methods were subsequently applied for estimating prediction errors in two real-life datasets from the food ingredients industry, where near-infrared spectroscopy was used to quantify i) urea in process water and ii) individual protein concentrations in ultrafiltration retentates from a protein fractionation process. Both the simulations and real data examples showed that the mean squared error of calibration is always a downward biased estimator. Although leave-one-out-cross-validation performed surprisingly well in the data analysed in this work, this paper demonstrated that the appropriate choice of error estimator requires the user to make an informed, data-centered decision.
- Open Access
- 3 March 2023
- Published by Elsevier in Journal of Food Engineering
- Vol. 350
Near-infrared spectroscopy as a process analytical technology tool for monitoring performance of membrane filtration in a whey protein fractionation process.
- 3 March 2023
- Published by Elsevier in Journal of Food Engineering
- Vol. 350
Open AccessNear-infrared spectroscopy as a process analytical technology tool for monitoring performance of membrane filtration in a whey protein fractionation process.
- Open Access
- 28 January 2021
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 75 (6) , 718-727
Prediction of α-Lactalbumin and β-Lactoglobulin Composition of Aqueous Whey Solutions Using Fourier Transform Mid-Infrared Spectroscopy and Near-Infrared Spectroscopy
Characterization and quantification of individual whey proteins are of crucial importance to many industrial dairy processes. Labor intensive wet-chemical methods are still being used for this purpose, but a rapid quantification method for individual whey proteins is highly desired. This work investigate the utility of Fourier transform mid-infrared spectroscopy and Fourier transform near-infrared spectroscopy for rapid quantification of the two main whey proteins (β-lactoglobulin and α-lactalbumin) in complex aqueous whey solutions simulating production process streams. MIR and NIR spectra obtained on whey samples with known and varying amounts of the proteins of interest and are used to develop partial least squares prediction models. Selection of informative wavelength regions allowed for prediction of β-lactoglobulin and α-lactalbumin concentrations with very high precision and accuracy (root mean square error of cross-validation, or RMSECV, of 0.6% and R 2 of 0.99 for NIR), demonstrating the potential of being implemented for rapid in-line monitoring of protein composition in industrial whey streams. Two-dimensional MIR-NIR correlation spectroscopy is used to identify the most informative parts of the NIR spectra in relation to protein secondary structure. In addition multivariate curve resolution is applied to the MIR data to resolve mixture spectra and to elucidate the spectral ranges that were most useful in distinguishing between the two whey proteins. The study concludes that NIR spectroscopy has potential for accurate in-line protein quantification and overall secondary protein structure quantification which open new possibilities for in-line industrial applications.
- 28 January 2021
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 75 (6) , 718-727
Open AccessPrediction of α-Lactalbumin and β-Lactoglobulin Composition of Aqueous Whey Solutions Using Fourier Transform Mid-Infrared Spectroscopy and Near-Infrared Spectroscopy
Characterization and quantification of individual whey proteins are of crucial importance to many industrial dairy processes. Labor intensive wet-chemical methods are still being used for this purpose, but a rapid quantification method for individual whey proteins is highly desired. This work investigate the utility of Fourier transform mid-infrared spectroscopy and Fourier transform near-infrared spectroscopy for rapid quantification of the two main whey proteins (β-lactoglobulin and α-lactalbumin) in complex aqueous whey solutions simulating production process streams. MIR and NIR spectra obtained on whey samples with known and varying amounts of the proteins of interest and are used to develop partial least squares prediction models. Selection of informative wavelength regions allowed for prediction of β-lactoglobulin and α-lactalbumin concentrations with very high precision and accuracy (root mean square error of cross-validation, or RMSECV, of 0.6% and R 2 of 0.99 for NIR), demonstrating the potential of being implemented for rapid in-line monitoring of protein composition in industrial whey streams. Two-dimensional MIR-NIR correlation spectroscopy is used to identify the most informative parts of the NIR spectra in relation to protein secondary structure. In addition multivariate curve resolution is applied to the MIR data to resolve mixture spectra and to elucidate the spectral ranges that were most useful in distinguishing between the two whey proteins. The study concludes that NIR spectroscopy has potential for accurate in-line protein quantification and overall secondary protein structure quantification which open new possibilities for in-line industrial applications.