DDDongdong Deng

Dongdong Deng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dongdong Deng has a total of 104 co-authors. Here are the top co-authors by number of shared publications:

  • Ling Xia

    Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China

    11 shared publications
  • Zhenyin Fu

    College of Biomedical Engineering & Instrument Science, Zhejiang University

    8 shared publications
  • Ruiqing Dong

    Department of Cardiology, Dushu Lake Hospital Affiliated to Soochow University

    6 shared publications
  • Zefeng Wang

    Department of Cardiology, Beijing Anzhen Hospital affiliated to Capital Medical University, Beijing, China

    5 shared publications
  • Ling Xia

    College of Biomedical Engineering & Instrument Science Zhejiang University Hangzhou Zhejiang China

    4 shared publications
  • Nan Zhang

    Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China

    4 shared publications

Latest Publications

  • Open Access

    Discrimination of sustained VT in structural heart disease using LGE-CMR and computational simulation: moving beyond LVEF

    by Kun Zuo, Kuibao Li, Lucheng Xu, Yiming Wang, Shiwei Lu, Zhaokai Kong, Zhenyin Fu, Jianjun Zhang, Ruiqing Dong, Ling Xia, et al.

    Background: Sustained ventricular tachycardia (VT) is a major cause of sudden cardiac death in structural heart disease (SHD). Risk stratification based on left ventricular ejection fraction (LVEF) remains suboptimal. This study aimed to develop an exploratory model integrating late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) scar characteristics with computational VT simulation to discriminate sustained VT, compared against LVEF. Methods: In this single-centre retrospective study, consecutive patients with suspected SHD who underwent LGE-CMR were enrolled. Patients with LGE-positive underwent quantitative scar analysis, personalized digital heart-twin reconstruction, and virtual electrophysiological simulation. Results: Among 82 patients (mean age 59.1 years; 82.9% male), 15 experienced sustained VT. Lower LVEF was associated with sustained VT ( P = 0.008; C-statistic: 0.730), as was visual LGE positivity ( P = 0.023; C-statistic: 0.634). Among LGE-positive patients, those with sustained VT had a larger core scar [10.0 [5.9, 14.8]% vs. 2.2 [1.1, 4.7]%; P < 0.001], larger grey zone [14.0 [10.9, 14.7]% vs. 5.7 [2.3, 9.2]%; P < 0.001], higher VT inducibility [50.0 [22.9, 66.9]% vs. 0 (0, 21.1)%; P < 0.001], and a greater number of inducible VT circuits [2 [2, 4] vs. 0 [0, 2]; P < 0.001]. An integrated LGE-VTsim index, derived from these four parameters, effectively discriminated sustained VT (C-statistic: 0.816) and remained independently associated with sustained VT after adjusting for LVEF (OR: 1.029; 95% CI: 1.008–1.051; P = 0.007). Conclusion: The LGE-VTsim index, integrating quantitative LGE-CMR scar assessment with computational simulation, represents a promising exploratory parameter in identifying patients at risk of sustained VT in SHD, beyond LVEF.

  • Open Access

    Left atrium incisure curvature: an indicator for predicting atrial fibrillation-related cardioembolism

    by Jianli He, Yuanyuan Wang, Jun Hou, Ping Chen, Wan Wei, Dacheng Hu, Zhenyin Fu, Dingchang Zheng, Ling Xia, Dongdong Deng, et al.

    The use of supplementary parameters, such as clinical criteria, biomarkers, and imaging data, may enhance the risk prediction of stroke and systemic embolic events. Current stroke risk scores are clinically practical but limited in their ability to predict stroke risk accurately in individual patients. It is difficult for doctors to distinguish patients with truly high-thrombotic risk. In this study, we propose a simple and effective method for predicting stroke and systemic embolic events in patients with atrial fibrillation (AF). In this retrospective study, 169 patients with AF were divided into three groups: Group A (those with paroxysmal AF with no cardioembolic events), Group B (those with persistent AF with no cardioembolic events), and Group C (those with persistent AF with cardioembolic events). By examining the chest CT images of all the included patients, we discovered that the left atrium (LA) incisure disappearing with the progression of AF, particularly in those with cardioembolic events (Group C). For the convenience of quantitative analysis, a border detection algorithm along with an LA incisure curvature computation algorithm was developed to predict cardioembolic events in patients with AF. The results indicated that the average curve rates of LA incisure were - 2.6 (-3.55, -1.95) ×10- 3, -1.40 (-2.13, -0.43) ×10- 3, and 0.51 (0.02, 1.40) ×10- 3 for Groups A, B, and C, respectively. The accuracy, sensitivity, and specificity of the LA incisure curvature for predicting cardioembolic events were 85.21%, 96%, and 80.7%, respectively. LA incisure curvature is an effective indicator for predicting AF-related strokes and systemic embolic events, which should be confirmed through multicentre retrospective and prospective research in the future.

  • Theoretical quantitative model and clinical outcome predictions of conductive cardiac patches for electrophysiological treatments

    by Yuchen Miao, Zhenyin Fu, Juhong Zhang, Yuhang Tao, Kai Pang, Chengjun Wang, Qianqian Jiang, Liyin Shen, Tian Xia, Peixuan Lu, et al.

    Myocardial infarction (MI) impairs cardiac electrical signal transmission, which could be partially remedied by implantable electroactive biomaterials. Here we characterize electroactive cardiac patches (eCarPs) with conductivities spanning five orders of magnitude both in vitro and in rat models. In contrast to common belief, we reveal that highly conductive eCarPs are more effective in lowering the risk of post-MI arrhythmia and preserving cardiac function with respect to eCarPs with conductivity similar to normal myocardium. We show that highly conductive eCarPs restore electrical signal conduction velocity across infarcted myocardium to healthy levels, while less conductive eCarPs fail to do this. We quantitatively demonstrate that three-dimensional cardiac simulation based on the monodomain model accurately replicates the effect of high-conductivity patches in eliminating conduction blocks in porcine myocardium and the locations of reentrant circuits in patients with MI. Our results suggest that eCarP conductivity higher than healthy human myocardium is preferred for lowering the risk of arrhythmia in patients by reducing the number of reentrants and stabilizing the reentrant routes.


  • Open Access

    Comparative analysis of the ten Tusscher and Tomek human ventricular cell models at cellular, tissue, and organ levels: Implications for post‐infarct ventricular tachycardia simulation

    by Ruiqing Dong, Zhenyin Fu, Chuxin Zhang, Yumeng Liu, Yiming Wang, Nan Zhang, Zefeng Wang, Jun Hou, Ling Xia, Yongquan Wu, et al.

    Computational modeling is a tool for exploring both normal electrical propagation in healthy hearts and cardiac arrhythmias in patients. While numerous human ventricular cell models exist, the ten Tusscher (TT2) model is one of the most used for simulating ventricular arrhythmia. Recently, the Tomek model has been proposed, offering improved accuracy by better reproducing key depolarization, repolarization, and calcium dynamics in healthy ventricular cardiomyocytes. However, a quantitatively comprehensive comparison of these models at the single‐cell, tissue, and organ levels has not been conducted. This study systematically compared the TT2 and Tomek models by evaluating electrophysiological parameters and reentrant properties in 0‐dimensional(0D), 1‐dimensional(1D), 2‐dimensional (2D), and 3‐dimensional (3D) simulations. Additionally, the effects of ion currents modifications to simulate ischemic scar‐related tissue were analyzed. These results reveal that although the TT2 and Tomek models demonstrate distinct 0D, 1D, and 2D characteristics, their 3D reentrant properties—specifically in terms of reentry locations and critical conduction channels—are highly comparable. Therefore, both models are suitable for simulating post‐infarct ventricular tachycardia (VT), as their shared 3D features effectively capture the essential mechanisms underlying this arrhythmia.


  • Open Access

    Progress in the Clinical Application of Artificial Intelligence for Left Ventricle Analysis in Cardiac Magnetic Resonance

    by Yinghui Le, Chongshang Zhao, Jing An, Jiali Zhou, Dongdong Deng, Yi He

    Cardiac magnetic resonance (CMR) imaging enables a one-stop assessment of heart structure and function. Artificial intelligence (AI) can simplify and automate work flows and improve image post-processing speed and diagnostic accuracy; thus, it greatly affects many aspects of CMR. This review highlights the application of AI for left heart analysis in CMR, including quality control, image segmentation, and global and regional functional assessment. Most recent research has focused on segmentation of the left ventricular myocardium and blood pool. Although many algorithms have shown a level comparable to that of human experts, some problems, such as poor performance of basal and apical segmentation and false identification of myocardial structure, remain. Segmentation of myocardial fibrosis is another research hotspot, and most patient cohorts of such studies have hypertrophic cardiomyopathy. Whether the above methods are applicable to other patient groups requires further study. The use of automated CMR interpretation for the diagnosis and prognosis assessment of cardiovascular diseases demonstrates great clinical potential. However, prospective large-scale clinical trials are needed to investigate the real-word application of AI technology in clinical practice.


  • Open Access

    Progress of Conductivity and Conduction Velocity Measured in Human and Animal Hearts

    by Zhenyin Fu, Ruiqing Dong, Huanyong Zheng, Zefeng Wang, Boyang Cao, Jinghui Bai, Mingxia Ma, Zhanchun Song, Fuzhi Pan, Ling Xia, et al.

    Cardiac conduction velocity (CV) is a critical electrophysiological characteristic of the myocardium, representing the speed at which electrical pulses propagate through cardiac tissue. It can be delineated into longitudinal, transverse, and normal components in the myocardium. The CV and its anisotropy ratio are crucial to both normal electrical conduction and myocardial contraction, as well as pathological conditions where it increases the risk of conduction block and reentry. This comprehensive review synthesizes longitudinal and transverse CV values from clinical and experimental studies of human infarct hearts, including findings from the isthmus and outer loop, alongside data derived from animal models. Additionally, we explore the anisotropic ratio of conductivities assessed through both animal and computational models. The review culminates with a synthesis of scientific evidence that guides the selection of CV and its corresponding conductivity in cardiac modeling, particularly emphasizing its application in patient-specific cardiac arrhythmia modeling.


  • Open Access

    Studying the Influence of Finite Element Mesh Size on the Accuracy of Ventricular Tachycardia Simulation

    by Boyang Cao, Nan Zhang, Zhenyin Fu, Ruiqing Dong, Tan Chen, Weiguo Zhang, Lv Tong, Zefeng Wang, Mingxia Ma, Zhanchun Song, et al.

    Background: Ventricular tachycardia (VT) is a life-threatening heart condition commonly seen in patients with myocardial infarction (MI). Although personalized computational modeling has been used to understand VT and its treatment noninvasively, this approach can be computationally intensive and time consuming. Therefore, finding a balance between mesh size and computational efficiency is important. This study aimed to find an optimal mesh resolution that minimizes the need for computational resources while maintaining numerical accuracy and to investigate the effect of mesh resolution variation on the simulation results. Methods: We constructed ventricular models from contrast-enhanced magnetic resonance imaging data from six patients with MI. We created seven different models for each patient, with average edge lengths ranging from 315 to 645 µm using commercial software, Mimics. Programmed electrical stimulation was used to assess VT inducibility from 19 sites in each heart model. Results: The simulation results in the slab model with adaptive tetrahedral mesh (same as in the patient-specific model) showed that the absolute and relative differences in conduction velocity (CV) were 6.1 cm/s and 7.8% between average mesh sizes of 142 and 600 µm, respectively. However, the simulation results in the six patient-specific models showed that average mesh sizes with 350 µm yielded over 85% accuracy for clinically relevant VT. Although average mesh sizes of 417 and 478 µm could also achieve approximately 80% accuracy for clinically relevant VT, the percentage of incorrectly predicted VTs increases. When conductivity was modified to match the CV in the model with the finest mesh size, the overall ratio of positively predicted VT increased. Conclusions: The proposed personalized heart model could achieve an optimal balance between simulation time and VT prediction accuracy when discretized with adaptive tetrahedral meshes with an average edge length about 350 µm.


  • Open Access

    TF-Unet:An automatic cardiac MRI image segmentation method

    by Zhenyin Fu, Jin Zhang, Ruyi Luo, Yutong Sun, Dongdong Deng, Ling Xia

    Personalized heart models are widely used to study the mechanisms of cardiac arrhythmias and have been used to guide clinical ablation of different types of arrhythmias in recent years. MRI images are now mostly used for model building. In cardiac modeling studies, the degree of segmentation of the heart image determines the success of subsequent 3D reconstructions. Therefore, a fully automated segmentation is needed. In this paper, we combine U-Net and Transformer as an alternative approach to perform powerful and fully automated segmentation of medical images. On the one hand, we use convolutional neural networks for feature extraction and spatial encoding of inputs to fully exploit the advantages of convolution in detail grasping; on the other hand, we use Transformer to add remote dependencies to high-level features and model features at different scales to fully exploit the advantages of Transformer. The results show that, the average dice coefficients for ACDC and Synapse datasets are 91.72 and 85.46%, respectively, and compared with Swin-Unet, the segmentation accuracy are improved by 1.72% for ACDC dataset and 6.33% for Synapse dataset.


  • Open Access

    Preliminary Study: Learning the Impact of Simulation Time on Reentry Location and Morphology Induced by Personalized Cardiac Modeling

    by Lv Tong, Caiming Zhao, Zhenyin Fu, Ruiqing Dong, Zhenghong Wu, Zefeng Wang, Nan Zhang, Xinlu Wang, Boyang Cao, Yutong Sun, et al.

    Personalized cardiac modeling is widely used for studying the mechanisms of cardiac arrythmias. Due to the high demanding of computational resource of modeling, the arrhythmias induced in the models are usually simulated for just a few seconds. In clinic, it is common that arrhythmias last for more than several minutes and the morphologies of reentries are not always stable, so it is not clear that whether the simulation of arrythmias for just a few seconds is long enough to match the arrhythmias detected in patients. This study aimed to observe how long simulation of the induced arrhythmias in the personalized cardiac models is sufficient to match the arrhythmias detected in patients. A total of 5 contrast enhanced MRI datasets of patient hearts with myocardial infarction were used in this study. Then, a classification method based on Gaussian mixture model was used to detect the infarct tissue. For each reentry, 3 s and 10 s were simulated. The characteristics of each reentry simulated for different duration were studied. Reentries were induced in all 5 ventricular models and sustained reentries were induced at 39 stimulation sites in the model. By analyzing the simulation results, we found that 41% of the sustained reentries in the 3 s simulation group terminated in the longer simulation groups (10 s). The second finding in our simulation was that only 23.1% of the sustained reentries in the 3 s simulation did not change location and morphology in the extended 10 s simulation. The third finding was that 35.9% reentries were stable in the 3 s simulation and should be extended for the simulation time. The fourth finding was that the simulation results in 10 s simulation matched better with the clinical measurements than the 3 s simulation. It was shown that 10 s simulation was sufficient to make simulation results stable. The findings of this study not only improve the simulation accuracy, but also reduce the unnecessary simulation time to achieve the optimal use of computer resources to improve the simulation efficiency and shorten the simulation time to meet the time node requirements of clinical operation on patients.


  • Fully Automatic Scar Segmentation for Late Gadolinium Enhancement MRI Images in Left Ventricle with Myocardial Infarction

    by Zheng-Hong Wu, Li-Ping Sun, Yun-Long Liu, Dian-Dian Dong, Lv Tong, Dong-Dong Deng, Yi He, Hui Wang, Yi-Bo Sun, Jian-Zeng Dong, et al.

    Summary Numerous methods have been published to segment the infarct tissue in the left ventricle, most of them either need manual work, post-processing, or suffer from poor reproducibility. We proposed an automatic segmentation method for segmenting the infarct tissue in left ventricle with myocardial infarction. Cardiac images of a total of 60 diseased hearts (55 human hearts and 5 porcine hearts) were used in this study. The epicardial and endocardial boundaries of the ventricles in every 2D slice of the cardiac magnetic resonance with late gadolinium enhancement images were manually segmented. The subsequent pipeline of infarct tissue segmentation is fully automatic. The segmentation results with the automatic algorithm proposed in this paper were compared to the consensus ground truth. The median of Dice overlap between our automatic method and the consensus ground truth is 0.79. We also compared the automatic method with the consensus ground truth using different image sources from different centers with different scan parameters and different scan machines. The results showed that the Dice overlap with the public dataset was 0.83, and the overall Dice overlap was 0.79. The results show that our method is robust with respect to different MRI image sources, which were scanned by different centers with different image collection parameters. The segmentation accuracy we obtained is comparable to or better than that of the conventional semi-automatic methods. Our segmentation method may be useful for processing large amount of dataset in clinic.